GE HISAR
CA NO GE(H)-41/2024-25 REWIRING / MAINT TO INTERNAL ELECTRIFICATION AND ACCESSORIES INCLUDING FAN REPAIR OF DSTV NORTH POCKET MD ACCN UNDER GE HISAR AT MIL STN HISAR
2024_MES_672332_1
CA NO GE(H)-41/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Hisar
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹70,000
Yes
23 Nov 2024
5 Sept 2024
7 Oct 2024
5 Sept 2024
5 Oct 2024
21 Sept 2024
Amount
Attending of complaints pertaining to faulty/Non-functional/working state of all accessories/equipments pertain to internal Electrification /ceiling fan/exhaust fan/DBs through telephone or in person during the working hours on detailment by MES Service centre for JCOs/ORs Md Accn of Hisar Mil Stn by deploying electrician and helper for locating and rectifying the faults which includes fault from Elect Meter/TPN/SPN DB onwards to Sub Main /Point wiring including replacement of fixtures like power and light socket, fan,exhaust fan, bell, security light of bldgs etc complete and carrying out repairs to the extent of disconnection and dismantling of faulty wires, submain wires, battens, bulk head lights conduits, boxes, Main switches, MCB, DBs, fan regulators, ceiling fans,exhaust fans and other E/M faults pertaining to particulars equipments for the rectification of defect and refixing of existing dismantled serviceable articles complete all as directed. Scope of work shall include:- (i) Replacement of bulbs /tubes held by users which will be handed over the repairer if so required. (ii)Taking down ceiling fan/exhaust fan of any make and any sweep at site, cleaning dust and opening up for examination, cleaning all parts and providing fresh lubricant to bearing/bush (oil or grease reqquired) fixing the fan in position after assembling and adjustment for proper running including testing for smooth running complete all as specified and directed. (iii) Installation of PVC canopy of Ceiling fan, blades of ceiling/exhaust fan, capacitor of any size for ceiling/exhaust fans, MS down rod for ceiling fan, frame and louvers for exhaust fans, hanging hook with washer,nut,bolts and rubber packing complete. (iv)The rate of job refers to maintaining the station internal electrification during the work excluding holyday /Sunday as directed by Einginner incharge . (v) The rate inclusive of maintaing daily complaint (point ) wise register/complaint slip etc signed by both parties or as directed by Engineer in charge (VI) The cost making good and matching the existing disturbed surface caused during these complaints shall be deemed to be included in this item . (VII) All the T&P required for excution of works shall be arranged by the contractor . (VIII) Cost taking down and ; removing and refixing of MCB DB,MCBs,LED Lights,switches,sockets,PVC blocks, Cover plates,bulb holder,junction box,fan regulator,capacitor etc item to; be replaced / repaired shall be deemed to be included in this item. Note: (i)Penality will be charged @ 250 Rs per day on absent of either mechanic/helper or Both. (ii) Cost of cable PVC copper flexible of size 23/0.0076 three core from ceiling rose to fan will be paid under appropriate item of schedule.
Dis-assembling carefully ceiling fans (any make) of 1200/1400mm sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge and weight not less than 325 gms including providing insulation by varnishing, oiling and greasing, replacing bearing and gun metal shaft required and reassembling back including testing complete. Note :- (i) Cost of bearings provided shall be measured in this item and nothing will be paid extra on this account. (ii) Working space if required, will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises (iii) If winded fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost. (iv)Cost of Machining work in body of ceiling fan by taking out worn out bearing, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying ceiling fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard (vi) Cost of shaft will be paid under appropriate item of Schedule.
Dis-assembling of exhaust fan of size 250mm/ 300mm AC 230 Volts, 50 Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper windings wire of suitable size and weight not less than 450gms and replacement of bushes, bearings, shafts, check nuts, bolts and washers, greasing, varnishing and reassembling back including testing complete. Note :- (i) Cost of bushes/bearings, provided shall be measured and paid in this item and nothing extra shall be paid on this account. (ii) Working space if required,will be provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises. (iii) If winded exhaust fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost. (iv)Cost of Machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account. (v) Cost of carrying exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard. (vi) Cost of shaft will be paid under appropriate item of Schedule.
M/L for Cutting of hole in existing wall for opning for exhaust fan and making good to faces where required and pointing in cement mortar 1:3 to ends or edges complet all as specified and directed by Engineer in charge.
Supply only capacitor 2.5 mfd to 3.15 mfd dry type for Ceiling fan make of capacitor : Epcos/Unistar/Usha/jyoti/supreme/Tibcon/Havells complete all as specified and directed.
Supply only capacitor 4 mfd to 6 mfd dry type for exhaust fan make of capacitor : Epcos/Unistar/Usha/jyoti/supreme/Tibcon/Havells complete all as specified and directed.
Preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Fan no with black synthetic enamel paint complete all as specified & directed.
Preparation of old painted surfaces of the body and blades, of exhaust fans of size 250/300mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Exhaust no with black synthetic enamel paint complete all as specified & directed.
Supply only of rubber bush complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep.
Supply and fix in replacement Ceiling fan stator 48 inch sweep 12 mm copper winding including ,thick steel bolt with double nuts and locking pins and high quality rubber bushing to reduce vibration complete all as specified and directed.
Supply and fix in replacement rotor complete with copper winding suitable for 48 inch sweep ceiling fan all as specified and directed.
Supply & Fix ceiling fan mild steel body set (upper & lower) with two set of bearings for ceiling fans of sweep 1200mm to 1400mm and any make and fixing in position complete.
Supply only PVC canopy set (upper & lower) for ceiling fans with of size 1200mm to 1400 mm sweep and any make and fixing in position complete.
Supply only of aluminium blades with fan blade screws of ceiling fan for any sweep( 1200mm to 1400 mm) & make complete.
Supply only MS heavy duty down rod of 15mm dia and 450mm length with necessary cutting / drilling holes and painting for ceiling fans complete all as specified and directed.
Supply only aluminium blades with screws of exhaust fan 250/300mm sweep of any make complete.
Supply only frame including rubber bush and all accessories suitable for exhaust fan 250/300mm sweep of any make complete.
S&F in replacement Wall mounting Fan 400 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers complete all as specified and directed. Make: Crompton/Havells/Bajaj
Supply only shaft for ceiling fan of sweep size 1200 to 1400 mm and fixing in position for smooth functioning of ceiling fan complete all as specified and directed.
Supply only shaft for exhaust fan of sweep size 250/300mm and fixing in position for smooth functioning of exhaust fan complete all as specified and directed.
S&F in replacement PVC air fresh air Fan 200 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed.
Supply & Fixing in replacement ceiling Fan 1200mm sweep 210 cfm Decoreted type with down rod , canopy, rubber reel etc including provision of three single core 0.5 sqmm copper conductor flexible cable connected from ceiling rose to fan and suitable size MS bolts, nuts for fixing ceiling fan complete all as specified and directed.
Supply only in replacement PVC flexible 3 core cable with copper conductor of size 23/0.76 mm from ceiling rose to fan including connection complete.-
Supply and fix in replacement of louvers iron with shutters suitable for existing exhaust fan of any size and shape at site complete all as specified and directed by Engg-in-charge
S&F in replacement of rigid non metallic PVC conduit 20mm complete with clamps and nuts bore all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
All as per item No 26.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 28.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 28.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 28.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 28.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per serial item No. 28.00 (here-in-before) but for one bell/buzzer point controlled by one bell push
All as per serial item No. 28.00 (here-in-before) but for One Light point controlled by two, two way switches with cables 1.5sqm size.
All as per srl item No. 28.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of sunk type modular pressed steel box covered with modular cover plate and frame for housing switch, socket , fan regulators etc for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' )
All as per item No 36.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 36.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 36.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 36.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per item No. 36.00 (here-in-before) but for one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per serial item No. 36.00 (here-in-before) but for One Light point controlled by two, two way switches.
All as per srl item No. 36.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts.
Supply and fixing in repairs modular type socket 6Amp - 3/5 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 3/6 pin combined 2 modle 230 volts AC complete all as specified and directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
S&F modular ceiling rose surface plastic 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
Supply and fix modular lamp holder, insluated body, with modular straight back plate suitable for batten fittings & complete all as specified & directed
Supply only switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply only switch piano flush type, single pole, one way, 15 Amp, 230 Volts.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply only flush type socket outlet multipurpose 3/5 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply only flush type socket outlet multipurpose 3/5 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply only lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed
Supply only ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
Supply only Ceiling fan regulator electronic four step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed. Make : Genric/Schneider/L&T/Legrand/Havells
Supply only bell push flush type, 5 Amp 240 Volts. Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T
Supply only Bell ding dong type, AC, 230 Volts, single pole.
S&F in replacement sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S/IndoAsian/HPL. Note:Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account.
S&F in replacement sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S/IndoAsian/HPL. Note:Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account.
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked for fixing in DB complete all as specified & directed. . Note :-Make of MCB shall be same of that DB
S & F MCB SPN, 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length. (ii) Cost of taking down existing submain wiring including all accessories is included in this item and nothing will be paid extra on this account
All as per item No 67.00 (here-in-before) but cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
All as per item No 67.00 (here-in-before) but 4 Sqmm cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
All as per item No 67.00 (here-in-before) but 2.5 Sqmm cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
Supply only in replacement single core cable with copper conductor 1.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade laid in existing conduit omplete all as specified and directed..
Supply only in replacement single core cable with copper conductor 2.5 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade laid in existing conduit complete all as specified and directed..
Supply only in replacement single core cable with copper conductor 4 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade laid in existing conduit complete all as specified and directed.
Supply only in replacement single core cable with copper conductor 6 Sq mm PVC insulated, FRLS unsheathed multistranded 1100 volts grade laid in existing conduit omplete all as specified and directed.
Supply only round blank PVC ceiling outlet wall plate covers for 4 inch dia electrical box with necessary plastic clamp and screws complete all as specified and directed by Engg-in-charge.
S&F in replacement PVC rectangular block of mounting, switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover of size 100mm x 100mm and 50mm deep sunk in wall including making good disturbed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in replacement PVC rectangular block of mounting, switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover of size 175mm x 100mm and 50mm deep sunk in wall including making good disturbed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 2 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 3 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 4 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 6 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 8module deep sunk in wall including making good distrubed surfaces complete all as specified and directed. Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable blocks is included in this item and nothing will be paid extra on this account.
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts
Supply and fixing in repairs modular type socket 6Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fix modular lamp holder, insluated body, with modular straight back plate suitable for batten fittings & complete all as specified & directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply and fixing LED lights fitting 1x 40W, 220V,AC wall mounted LED batten with aluminium extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V,AC wall mounted LED batten with aluminium extruded polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder, Aluminium housing connecting up with three core flexible copper conductor cable of suitable size.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified.
Supply and fixing in repairs decorative wall light, stainless steel rust free fixture with white glass diffuser including 20 watt capacity minimum LED filament lamp complete all as specified and directed.
Supply and fixing in repairs round / square surface mounting 12watt minimum capacity LED panel in PDC housing and high translucent frosted plastic diffuser with 100lm/ w efficiency complete all as specified and directed.
S&F in replacement 3mm thick laminated sheet for housing switches for required size including drilling holes for fixing complete all as specified and directed..
Supply only 15/16 Amps plug top with light indicator 3 Pin made out of fire resistant material polycarbonate complete all as specified and directed by Engg-in-charge.Make: HPL/Havells/Legrand/Polycab/SSk/Honeywell/L&T/Hi-plast
Supply only metal clad plug Socket 20 Amp (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo
Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo
Supply only modular Ceiling fan regulator 1/2 Module BLDC type of suitable wattage, 230V suitable for 1200 ceiling fan etc complete all as specified and directed.
Supply and fixing in repairs piano type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs exhaust fan motor suitable for 225/250 mm sweep,single phase 240 volt AC, copper winded having minimum 1400 RPM complete all as specified and directed by Engg.
M&L for cleaning internally and externally by scraping all scales, dirt etc, from meter Box of Size 40''X35"X11.5" and applying painting to Meter boxes with two coats of synthetic enamel hammer tone paint over a coat of red oxide primer by spray painting.Note:(i) Cost of labour for Dismantling And Refixing of E/M electrical Gear and switches like Meter,MCBs,elctrical cable and connection etc during painting is including in this item and nothing will be extra on this account (ii) Cost of testing and checking all electrical Connection after work is included in this item.
Supply, fabricating, bending to give shape as per existing, welding and fixing in replacement of galvanised iron sheet work For meter Box Panel of size as per existing like 9.5"X10.5"/34''X7"/22"X10.5"/11"X10.5" or as per site requirement made out of galvanised iron sheet of thickness 2.15mm minimum and including provision of locking arrangement of Each compartment of Meter Box panel compete all as specified and as directed by Engineer-in-Charge. Note :- (i) Payment shall be measured and paid as per actual size of GI metal sheet material .
Supply, fixing, connecting & testing of XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty) with aluminum conductor, 1100 V grade cross sectional area 35 sqmm 3.5 core laying in trenches/floor/fixing on walls or passing through pipe complete all as specified and directed by Engr-in-Charge.Note:(i) Cost of clamps/screws/nut/bolts etc required for fixing the cable is included in this item and nothing will be paid extra on this account.
Supply and fix cable cover HDPE DWC pipe of size 40 mm internal Dia minimum for protection of XLPE cable 1100 volts 35 Sqmm size as per IS 14930 complete all as specified and directed by Engg-in-charge.ote:(i) Cost of clamps/screws/nut/bolts etc required for fixing the cable is included in this item and nothing will be paid extra on this account..
Supply and fix transparent cover for Meter reading box of size 4.75"x4.75" /as per existing of superior quality complete all as specified and directed by Engg -in-charge.
Supply and fix cable jointing kit straight through for 1100 V grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size 25 to 35 sqmm complete all as specified.
Material and labour for Main Meter Box panel for all 06 Nos meters, 240/415 Volt AC supply operated system locating by fault and replacement of unserviceable parts and components complete all as specified and directed as per the following:-(a) Replacement of complete worn out/old internal wiring single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade for phase,neutral and erath, and connect the same with proper copper lugs and terminals through protection pipe/ flexible pipe. (b) Replacement of worn out faulty internal MCBs/ indicating / measuring instruments and connect the same with proper copper lugs and terminals through new MCBs/indicating/measuring instrument. (c) Insulation of bus bar by proper colour code sleeves. (d) Testing of system on load. Note:- (i) Cost of Flexible pipe,Insulation sleeve, complete sub main wiring,lug and terminals is included in this item and nothing will be paid extra on this account. (ii) Cost Of MCBs/indicating/measuring instument if installed will be paid under appropriate item of BOQ.
Supply only PVC clamp holder suitable for ceiling fan/exhaust fan capacitor of superior quality all as specified and directed
NAVIN KUMAR (BID ID -3117895)
M/S SURJIT CONSTRUCTION COMPANY (BID ID -3129834)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .