Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC lowest | |
| 2 | L2₹31.9 L+₹1.5 L (5.06%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹32.4 L+₹2.1 L (6.80%)Rejected-Finance | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹38.3 L+₹8.0 L (26.3%)Rejected-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹41.1 L+₹10.7 L (35.3%)Rejected-Finance | L5 | Rejected-Finance RATE HIGH |
| Sl No | Description | Qty | Unit | Mahindra Electric Stores L3 | Leo Enterprises L2 | SUNIT TRADING CORPORATION L6 | Rama Electricals L1 | tulsani associates L5 | R R Associates L4 | RELIABLE ENTERPRISES L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair and maintenance of all types of Street / Security light fittings OF 45/60/70/90/120 watts capacity and flood light fittings of any capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place complete all as directed by Engr-in-charge.
Note:
(i) The cost of labour and allied expenses deemed to be included in unit quoted rates of this item.
(ii) Cost of spares like electronic driver, surge protection device (SPD), connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of BOQ.
(v) T&P and Vehicle mounted hydraulic ladder (If required) shall be arranged by the contractor and the cost of same shall be deemed to be included in unit quoted rate of this item.
(vi). The contractor shall maintain proper record of repaired / maintained by him in a binded register duly bringing out the details of spares replaced on each and every street light. The contractor shall put up the record register to Engineer-in-charge for inspection as and when he asked for.
(vii). Attending of one number light fitting and make it functional shall be measured as one job. | 250 | Each Job | 300 ₹75,000 | 200 ₹50,000 | 310 ₹77,500 | 100 ₹25,000 | 180 ₹45,000 | 50 ₹12,500 Lowest | 800 ₹2,00,000 |
| 2.00 | Supply and fix in replacement Electronic driver suitable for 90watts LED security light fittings complete all as directed by Engr-in-charge. | 30 | Each | 300 ₹9,000 Lowest | 300 ₹9,000 Lowest | 795 ₹23,850 | 500 ₹15,000 | 1,800 ₹54,000 | 600 ₹18,000 | 800 ₹24,000 |
| 3.00 | Supply and fix in replacement Electronic driver suitable for 45 / 48 / 50/60 / 70/ 90/ 120 watts LED road way/Flood light/post top complete all as directed by Engr-in-charge. | 29 | Each | 400 ₹11,600 | 200 ₹5,800 Lowest | 705 ₹20,445 | 600 ₹17,400 | 1,500 ₹43,500 | 600 ₹17,400 | 800 ₹23,200 |
| 4.00 | Supply and fix in replacement electronic driver 10 watt bolard fitting complete all as directed by Engr-in-charge. | 20 | Each | 400 ₹8,000 | 200 ₹4,000 Lowest | 692 ₹13,840 | 700 ₹14,000 | 1,200 ₹24,000 | 600 ₹12,000 | 500 ₹10,000 |
| 5.00 | Supply and fix in replacement PCB LED set for 10 watt suitable for bollard fitting complete all as directed by Engr-in-charge. | 20 | Each | 500 ₹10,000 | 300 ₹6,000 Lowest | 1,020 ₹20,400 | 800 ₹16,000 | 800 ₹16,000 | 600 ₹12,000 | 1,000 ₹20,000 |
| 6.00 | Supply and fix in replacement electronic driver suitable for 150 watts flood lights complete all as directed by Engr-in-charge. | 20 | Each | 400 ₹8,000 | 300 ₹6,000 Lowest | 1,225 ₹24,500 | 500 ₹10,000 | 1,500 ₹30,000 | 600 ₹12,000 | 1,000 ₹20,000 |
| 7.00 | Supply and fix in replacement electronic driver suitable for 100 watts flood lights complete all as directed by Engr-in-charge. | 22 | Each | 400 ₹8,800 | 300 ₹6,600 Lowest | 1,050 ₹23,100 | 800 ₹17,600 | 1,200 ₹26,400 | 600 ₹13,200 | 1,000 ₹22,000 |
| 8.00 | Supply and fix in replacement surge protection device(SPD) of capacity 10KV compatible with industrial & outdooor LED fixtures complete all as specified and directed by Engr-in -charge. | 20 | Each | 250 ₹5,000 | 200 ₹4,000 Lowest | 295 ₹5,900 | 300 ₹6,000 | 250 ₹5,000 | 700 ₹14,000 | 2,000 ₹40,000 |
| 9.00 | Supply and fix in replacement of MCB SP 230 volts B curve 5 to 32 amps complete all as specified and directed | 50 | Each | 150 ₹7,500 | 190 ₹9,500 | 122 ₹6,100 Lowest | 180 ₹9,000 | 190 ₹9,500 | 150 ₹7,500 | 200 ₹10,000 |
| 10.00 | Supply and fix in replacement of MCB SPN 230 volts B curve 32 amps complete all as specified and directed | 20 | Each | 600 ₹12,000 | 250 ₹5,000 | 210 ₹4,200 Lowest | 250 ₹5,000 | 560 ₹11,200 | 600 ₹12,000 | 650 ₹13,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
19 Aug 2025, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GEN BHAGAT MARG PUNE 40
8714 MAINT REPAIR REPLACEMENT OF STREET LIGHT FLOOD LIGHT HIGHMAST LIGHT GARDEN LIGHT AND OTHER ELECTRICAL ALLIED WORKS IN MITS ALC DCA VIKRAM BATRA INF BN MAP AREA STEVELY CARRIAPPA ENCLAVE EME WKSP SHO AND CONNECTED AREA OF AGE EMI OF GE SOUTH PUNE
2025_MES_718085_1
8714 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹98,000
Yes
30 Sept 2025
3 Jul 2025
21 Aug 2025
3 Jul 2025
19 Aug 2025
5 Aug 2025
Amount
Repair and maintenance of all types of Street / Security light fittings OF 45/60/70/90/120 watts capacity and flood light fittings of any capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place complete all as directed by Engr-in-charge. Note: (i) The cost of labour and allied expenses deemed to be included in unit quoted rates of this item. (ii) Cost of spares like electronic driver, surge protection device (SPD), connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of BOQ. (v) T&P and Vehicle mounted hydraulic ladder (If required) shall be arranged by the contractor and the cost of same shall be deemed to be included in unit quoted rate of this item. (vi). The contractor shall maintain proper record of repaired / maintained by him in a binded register duly bringing out the details of spares replaced on each and every street light. The contractor shall put up the record register to Engineer-in-charge for inspection as and when he asked for. (vii). Attending of one number light fitting and make it functional shall be measured as one job.
Supply and fix in replacement Electronic driver suitable for 90watts LED security light fittings complete all as directed by Engr-in-charge.
Supply and fix in replacement Electronic driver suitable for 45 / 48 / 50/60 / 70/ 90/ 120 watts LED road way/Flood light/post top complete all as directed by Engr-in-charge.
Supply and fix in replacement electronic driver 10 watt bolard fitting complete all as directed by Engr-in-charge.
Supply and fix in replacement PCB LED set for 10 watt suitable for bollard fitting complete all as directed by Engr-in-charge.
Supply and fix in replacement electronic driver suitable for 150 watts flood lights complete all as directed by Engr-in-charge.
Supply and fix in replacement electronic driver suitable for 100 watts flood lights complete all as directed by Engr-in-charge.
Supply and fix in replacement surge protection device(SPD) of capacity 10KV compatible with industrial & outdooor LED fixtures complete all as specified and directed by Engr-in -charge.
Supply and fix in replacement of MCB SP 230 volts B curve 5 to 32 amps complete all as specified and directed
Supply and fix in replacement of MCB SPN 230 volts B curve 32 amps complete all as specified and directed
Supply and fix in replacement of MCB TPN 230 volts C curve 63 amps complete all as specified and directed
Supply and fix in replacement of digital time switch, DIN type daily / weekly with 25 ON/OFF programmes , 16 amps 240 volts AC complete all as specified and directed
Supply and fix in replacement of Power contactor 16/18 amps 3 pole complete all as specified and directed
Supply and fix in replacement of Power contactor 40 amps 3 pole complete all as specified and directed
Supply and fix in replacement of PVC insulated Copper conductor FRLS grade three core cable 1.5 sqmm, ISI marked complete all as specified and directed
Supply and fix in replacement PVC insulated Copper conductor FRLS grade three core cable 2.5 sqmm, ISI marked complete all as specified and directed
Supply and fix in replacement MCCB 63 Amps 4 pole 415 volts complete all as specified and directed
Supply and fix in replacement relay of capacity 110V-240V AC Capacity complete all as specified and directed
Supply and fixing in repairs LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repairs LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repairs LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repair 150 watt 230 V AC outdoor type, High performance LED floodlight luminaire with pressure die-cast housing, toughened glass and secondary lens optics efficacy 120 lm/W and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repair 200 watt 230 V AC outdoor type, High performance LED floodlight luminaire with pressure die-cast housing, toughened glass and secondary lens optics efficacy 120 lm/W and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
Supply and fixing in repair LED Highway light 100 watt 230 V AC with pressure die-cast housing ,integrated PC optics and 150 lm/w efficienc. 4kV in-built and 10 kV external surge protection, equipped with IP66 protection,complete all as specified and directed by Engr-in-charge. Make : Bajaj/Havells/Crompton/Philips
S&F in repair Rigid non-metallic PVC conduit 25 mm outer diameter inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply, installing, connecting & testing in repairs of terminal box (Housing box) for Hepa filters (Plenaum 8'x8') in OTs with and including the following provisions, complete all as directed by Engr-in-Charge :- (i) Cleats for suspenders (Qty- 14 Nos) (ii) Differential pressure measurement ports (2 Nos) (iii) Opening for duct connections - 04 Nos (725x150mm) (iv) Aluminium housing Main Body (Duly epoxy powder coated) (v) Space for Mini pleat Hepa Filters size 915x610x75 mm (10 Nos) (vi) Box for special light (563x590 mm. Approx) (vii) Aluminium perforated grill (Powder Coated) (viii) CFM per filter = 750 (ix) Total CFM= 7500 (X) Body will be in two pieces i.e. 980mmx2625 & 1615mmx2625. When joined together will make 2600 mm x 2625 mm.
Supply and fixing in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant including necessary fixing arrangements as required at site with driver and lamp complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant including necessary fixing arrangements as required at site with driver and lamp complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair 20 watts LED post top Antique gate/pillar light made from cast aluminium, with diffuser of engineering graden polymer and cast aluminium pole base, IP 65/66 protection, with B22 holder suitable for LED bulb 20W with 20 watt lamp complete all as specified and directed by Engr-in-charge.
Supply and fix in repairs garden light fittings LED CW/WW type 10 watt, LED bollard with opal acrylic diffuser and IP66 protection aluminium pipe housing with soft 360 light, resistance to corrosion complete with necessary fixing arrangements suitable for operation on 230 volt 50 Hz AC supply including all standard fittings & fixture with and including PCC type C-1, 1:3:6 as in foundation complete all as directed by Engineer-in-Charge
S & F in replacement of factory made PVC Junction boxes of size 250x200x80mm for street light fittings including with weather proof IP-54 protection, hinged door, with Bakalite connector 100 Amps capacity, 4 way and 01 No. MCB SP of 6 Amp, necessary fixing arrangement with two nos of clamp, nuts, bolts, including 2 Nos. of suitable size of double compression cable glands for cable entry and exit complete all as specified and directed by Engr-In-Charge
S & F in replacement factory made PVC Junction boxes of size 140mm x 140 mm x 95 mm for out door light fittings, including with weather proof IP-54 protection, hinged door, with Bakalite connector 100 Amps capacity, 4 way and 01 No. MCB SP of 6 Amp, necessary fixing arrangement with 02 nos. of clamp, nuts, bolts, including 2 Nos. of suitable size of double compression cable glands for cable entry and exit complete all as specified and directed by Engr-In-Charge
S& F GI tubing light grade with all fitting like bend elbow socket etc 40 mm dia ISI marked with all fittings laid in trenches and fixed pole by flat iron clamps, nut, bolt, washers suitable size including refixing of existing cable complete all as specified and directed.
S& F GI tubing light grade 50 mm dia ISI marked with all fittings laid in trenches and fixed pole by flat iron clamps, nut, bolt, washers suitable size complete all as specified and directed.
M&L for removing existing damaged reflected strips from LT street pole and supply and fixing of new 2 inch width retro reflective tape fixed to Street light Poles with red colour complete all as directed by Engr-in- Charge
M&L for removing existing damaged reflected strips from pole supply and fixing of new 2 inch width retro reflective tape fixed to Street light Poles with yellow colour complete all as directed by Engr-in- Charge
M&L for removing existing damaged reflected strips from pole supply and fixing of new 2 inch width retro reflective tape fixed to street light poles with white colour complete all as directed by Engr-in- Charge
M & L for making hole on a street light pole top and bottom for entry of service wire of 2.5 /1.5 sqmm disconnecting the existing service connection from junction box and fitting and same has been reconnecting to junction box and fitting complete all as directed by Engr-in-charge. Note:- Service wire will be measured & paid for separately
Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that the clearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole / Fitting and disposal where directed not exceeding 50 mtr complete all as specified and as directed by Engr-in-Charge. Note- (i) The cost of T&P / ladder required for trimming and punning of tree or branches deemed to be included in unit quoted rate. (ii) Distance between two poles will be measured as one span.
Taking down unserviceable old bracket from street light pole and supply and fix new street light bracket made out of MS pipe heavy duty 40 mm dia and not exceeding 1.5 mtr in length for fixing of fittings with two nos. of MS clamp fabricated out of MS flat of suitable size including nut, bolt, washers etc to fix the bracket on pole complete all as directed by Engr-in-charge.
Dismantling unserviceable steel poles / struts and removing from site, any size including dismantling of PCC complete all as directed.
Supply, erecting and fixing of double arm deco LED street light pole, Antique design decorative poles of 3.50 m height with option of twin luminaries, pole duly powder coated, housing made from CRCA / GI Pole, the poles have diameter 60 mm to 90 mm at the top and 114 mm to 140 mm at the bottom and base shall be made of die cast MS with holes suitable for 16/20/24 mm foundation bolts etc. with and including numbered on each pole etc. complete all as specified and directed by Engr-in-charge. Note:- Excavation, earth work and PCC work for embedding pole shall be measured and paid separately.
Supply, erecting and fixing in replacement LED light 50 Watts, antique designed aesthetically appeling landscape cum street light, made from aluminium housing, clear polymer diffuser to provide uniform and pleasant light output with IP 65/66 protection complete all as specified and directed by Engr-in-charge.
Supply, errecting and fixing in replacement of steel tubular swaged welded pole of over all height 9.0m long, 410-SP-31 type, conforming to IS-2713 (Part I to III 1998) with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., with and including the following provisions complete all as specified and directed by Engr-in-charge:- (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid separately. (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer. (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv) Pole below ground shall be tarred by one coat of bituminous paint (v) Poles shall be numbered as ditrected.
Taking down of old unserviceable cable and Supply, laying, jointing, testing and commissioning of LT underground cable, XLPE insulated and sheathed heavy duty armoured with aluminium conductor 1100 volt grade with cable glands, lugs etc complete all as specified and directed for the following sizes of cable:- (a). 6 sqmm 4 core
(b). 10 sqmm 4 core
(c). 16 Sqmm 4 core
(d). 25 Sqmm 4 core
(e). 35 Sqmm X 4 Core
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft / loose soil complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in Hard / Dence soil complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in Soft / dis-itegrated rock complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and exc. 1.5 m depth but not exc. 3.0m as foundation for pole etc and getting out in soft / loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for laying double wall corrugated pipe of 50 mm inner diameter and 63 mm outer diameter size and before laying excavated area shall be leveled complete all as specified and directed
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Material & labour PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in stays and coping of poles including necessary form work incluidng dismandiling of existing PCC complete all as specified and directed.
Material and labour for painting of steel tubular pole 9 m height including cross arm, clamp, back plate etc in situ on with one under coat and one finishing coat with aluminium paint after cleaning preparation of surface including making alternate yellow and black strip 30 cm wide 5 nos. with two coat of synthetic enamel paint complete all as specified and as directed by the Engr-in-charge.
M&L for testing of fault locating in LT cable with the help of bringing Cable fault locating machine at site complete all as specified and directed by Engr-in-Charge. Note- Machine for locating of fault will be arranged by the contractor at his own cost and nothing extra on this account will be admissible.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 16 Sqmm 4 core including all accessories required and excavation & earthwork complete all as specified and directed by Engr-in-Charge
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 25 to 50 Sqmm 4 core including all accessories required and earthwork complete all as specified and directed by Engr-in-Charge
Supply & fix timeline distribution board, timeline 40 amps 3 pole, 230 volts with Astronomincal time switch Cat Part No TL040ASO of Indo Asian or equivalant to L&T /Havells / Schneider, to be fixed for wall and pole with mounting arrangement. The distribution board shall be mounted on MS angle iron frame made out of 40x40x5mm size and which will be grouted 30cm in ground with PCC 1:3:6 type C-1 as in foundation of suitable size and 70 cm (30cm +40 cm) above ground level including with necessary fittings and fixtures complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement integral LED aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on high mast light frame/ Over head Tank complete all as specified and directed.
M&L for testing of exisiting earthing resistance with suitable digital Earth tester and recording the readings obtained and making the earthing good by pouring the salt water etc. complete all as directed by Engr-in-Charge. Note :- Value of earth resistance should be less than 1 Ohms for equipments earthing and less than 5 ohms for LA & Power Supply earthings.
M&L for testing of exisiting earthing resistance with suitable digital Earth tester and recording the readings obtained etc. complete all as directed by Engr-in-Charge. Note : A register will be maintained for building / establishment / section wise (for Equipment earthing, LA, Power etc) duly obtaining the sign of the user.
M&L for construction of earth chambers by demolishing of existing unserviceable earth chambers and M&L for construction of new chambers of PCC 1:3:6 type C1 bed and chamber RCC 1:2:4 type B1, iron grill incuding GI cover of existing size with hinge etc. all as per electrical plate no.3 of SSR part-I, complete all as specified and directed by Engr-in-charge.
M&L in repairs 25x4mm galvanised iron strip as in earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as directed and specified by Engr-in-charge.
M&L for marking of pole numbers on street light poles with synthetic enamel paint or stickers made out of suitable material of approved shape and size complete all as per sample provided by Engr-in-charge.
Dismantling rusted/defective LT panel doors / canopy and supplying, fixing and fabricating of new LT panel doors of size all as per existing with 3.15 mm thickness MS sheet, hinges, locking arrangement etc complete including replacement of neoprene gasket and applying two coats synthetic enamel painting with a coat of red oxide primer complete all as directed by Engr-in-Charge.
M&L for complete removal of old paint from steel surfaces by scrapping of surfaces with wire brush and applying two coats of synthetic enamel paint of approved shade on exposed surfaces of LT panel boards including writing / marking feeders complete all as specified and as directed by Engr-in-charge.
M & L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and galvanized iron strip 25×4mm and GI pipe 40 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provision of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil / strata on completion etc complete all as specified and directed by Eng-in-Charge. Note : The cost of GI earth strip & GI protection pipe up to 7.50m length shall be deemed to be included in unit quoted rates of this item.
Taking down the letter sign board of any capacity from any hight and repairs/ replacing the defective parts like electronic drivers connection wires, strip ighting and refixing the same to its original position complete all as directed by Engr-In-Charge. Note :- Cost of spare parts of sign board which are required for smooth functioning of sign board shall be deemed to be included in unit quoted rate.
M & L for earthing with galvanised steel earth plate electrode 600x600x6.3mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil / strata etc complete all as specified and directed by Engr-in-Charge. Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.
Leo Enterprises (BID ID -3390666)
Mahindra Electric Stores (BID ID -3386557)
R R Associates (BID ID -3385907)
tulsani associates (BID ID -3399422)
SUNIT TRADING CORPORATION (BID ID -3391037)
RELIABLE ENTERPRISES (BID ID -3387913)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .