Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.6 L+₹2.0 L (6.23%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹38.4 L+₹5.9 L (18.1%)Rejected-Finance 7 4 DNYANESH SOCIETY WARJE MALWALDI PUNE 411 058 | PUNE | MAHARASHTRA | 411058 | L3 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹75,100
Closing Date
19 Dec 2020, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer Central Arjun Marg Pune 411001
8199 ADDITION ALTERATION TO EXISTING PERIPHERY WALL ADJACENT TO SOLAPUR ROAD HIGHWAY ADDITION ALTERATION TO PARADE GROUND AND ADDN ALTERATION TO WAR SURGERY MUSEUM AT AFMC UNDER GE CENTRAL PUNE
2020_MES_396529_1
8199 ADDITION ALTERATION TO EXISTING PERPHERY WALL
Open Tender
Civil Works
Item Rate
183 days
Garrison Engineer (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹75,100
Yes
22 Jan 2021
19 Nov 2020
21 Dec 2020
19 Nov 2020
19 Dec 2020
5 Dec 2020
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing rubbish off the premises complete all as directed.
All as per item No 1 here-in-before but reinforced cement concrete including cutting of reinforcement to facilitate demolition complete.
Demolition of brick or stone / boulder masonry, built in cement mortar including removing rubbish of the premises complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided and removing from site complete all as directed
Dismantling timber scantling under 40 sqcm in section in framed work in any position and of any description etc including removing from site complete all as directed
Dismantling boarding of any description fixed in any position with screws / nails etc including removing from site complete all as directed
Taking down chowkat or frame with shutter exc 1.5 but not exc 4 Sqm each (without taking off shutters from the frame) including removing from site complete all as directed
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof covering and removing from site complete all as directed
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with soil complete all as specified and directed.
Removing excavated soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D2 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B0 using 12.5mm stone graded aggregate as in cill, plinth courses, parapets and railings, coping, kneelers, apex stones, bed blocks, kerbs etc and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M&L for reinforced cement concrete Design mix M-25 using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete
All as per item No 16 here-in-before but as in columns, pillars, piers, posts and struts complete
All as per item No 16 here-in-before but in beams, cantilevers, lintels over 1.5m span etc complete all as specified complete
use and waste of formwork to flat rough finished sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work vertical or to batter complete
All as per item No 19 here-in-before but to sides of pillars, posts, struts, piers, columns, and stanchions complete
All as per item No 19 here-in-before to sides of beams, tie beams, RCC/PCC bands and similar work flat rough finished surface of concrete complete all as specified and directed
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) grade D-5and setting in CM 1:6 complete all as specified and directed.
M&L for precast cement concrete block masonry not exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-4 and setting in CM 1:4 complete all as specified and directed.
M&L for 2nd class hardwood, plain straight chowkats and frames, wrought, framed rebated on the soild, rounded or chamferrd, put together with glue pinned at joints, complete all as specified and directed.
M&L for 30mm thick glazed and skeleton shutters of 2nd class hard wood, with edges of sash bars and framing moulded, prepared to receive glass, gauze etc (without sash bars), sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) and fitted to chowkats all as specified and directed.
M&L for 5mm thick PVC sheet fillets of width 35mm for wall panelling inclusive of fixing to wall or to PVC frame all as specified and directed.
M&L for solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame all as specified and directed.
M&L for 100mm size butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed type B-11 complete all as specified and directed.
M&L for 150mm extruded brass handles, fabricated type polished complete all as specified and directed.
M&L for brass mortice lock 4 lever vertical type size 100mm complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column, hooping ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed.
S&F mild steel TMT bars 8mm dia cut to length bent to shape required including cranking bending as in stirrups, binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed.
S&F mild steel framed work as in grills / railing etc with ends of bars shouldered and or rivetted or forged into spikes, for bracing, railing etc and similar work conforming to Fe 290 gde E 165 complete all as specified and directed.
S&F mild steel framed work as in as grills, gratings etc. for ornamental and intricate design with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade E-165 complete all as specified and directed.
S&F mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doorrs, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410-W (Gde E-250 quality A) complete all as specified and directed.
M&L for purpose made butt hinges and holdfasts conforming to Fe-410-0 or Fe 310-0 suitable for fixing to RCC columns complete all as specified and directed.
S&F ball bearing for steel gate to be fixed with CI wheels and hinges for easy movement complete all as specified and directed.
S&F mild steel FI track including it's fixing lugs and stiffeners including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F purpose made hasp and staples, sliding bolts, clamps, hold fasts, wind ties and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
S&F cast iron wheels for steel gates including all fitting as required to fix in position complete all as specified and directed.
S&F stainless steel (SS) letter fixed on granite or steel sheet with ornamental and intricate design in English complete all as specified and as directed by Engineer-in-Charge (size of letter : height not less than 300mm). Note:- Cost of granite or steel sheet shall be measured and paid separately.
S&F stainless steel (SS) logo of AFMC fixed on granite or steel sheet with ornamental and intricate design complete all as specified and as directed by Engineer-in-charge (size of logo : height not less than 450mm, width proportionate as per existing design of AFMC logo). Note:- Cost of granite or steel sheet shall be measured and paid separately.
S & F 12mm thick seamless calcium silicate ceiling made out of 1800 x 1200mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having phillips head with under head cutter at 200mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finish on and including anodised aluminium snap grid frame work with hangers 6 mm dia GI (upto 1200 mm long) adjusting level fixed to roof slab by means of ceiling cleats made outof GI flat 40x3mm size 60mm long and expansion hold/fastner 12.5mm dia 40mm long complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of thickness 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for 100 mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) for sub base complete all as specified and directed.
M&L for 50mm thick levelling course in cement concrete 1:2:4 type B1 using 20mm graded aggregate complete all as specified and directed.
M&L for Vitrified ceramic tiles (dark shade) 10mm thick (square /rectangular) polished, area of each tiles exceeding 0.42 sqm and n.exc 1.00 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles over and including 15mm thick screed bed in cement mortar 1:6 complete all specified and directed.
M&L for Vitrified ceramic tiles (dark shade) 10mm thick (square /rectangular) polished, area of each tiles exceeding 0.42 sqm and not exc 1.00 Sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over and including 10mm thick backing coat in cement mortar 1:3 complete all specified and directed.
M&L for 16-18mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick rendering in CM (1:3) complete all as specified and as directed
M&L for machine pressed precast cement concrete glazed interlocking paver block 60mm thick in floor/ pavements laid over 30mm thick sand cushioning laid dry to the profile including vibrating with surface vibrator after laying of tiles complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on PCC block wall/ concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed.
All as per item No 51 here-in-before but 15mm thick in CM (1:4) on external surface of wall.
M&L for 5.5mm thick frosted glass with polishing and carving complete and fixed to shutter all as specified and as directed.
M&L for french polishing on surfaces of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed
M & L for preparation of newly plastered surface of seamless false ceiling and applying two coats of OBD of approved tint over one coat of primer over 3mm thick putty complete all as specified and directed
M & L for preparation of newly or previously untreated steel surfaces of any descripton and applying two coats of synthetic enamel paint over a coat of red oxide primer, of girth exceeding 10 cm in width or girth complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description of steel, iron etc., exceeding 10cm in width or girth and applying two coat of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / change over switch of any type/ description as existing at site including MCBs of any type /capacity and making good the disturbed surfaces to match with the existing finishes all as specified directed.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified directed.
M&L point wiring complete with and including single core FRLS PVC insulated un-sheathed flexible bright annealed multi stranded copper conductor cables 1.5 sqmm (22/0.30mm) 1100Volts grade drawn through and including heavy duty PVC rigid conduits of suitable size totally concealed in walls /floors etc. all conduit accessories/fittings/junction boxes/inspection covers etc. of heavy grade, ISI marked and modular type sunken boxes factory made complete with modular cover and frame including 1.5 sqmm 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/fans etc. at one end to common earth dolly at other end, complete all as specified. Note- Quoted rate shall deemed to be included for cutting chases in walls and making good disturbed surface to match with the existing surface complete.
(a) One light point controlled by one, one way switch.
(b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board .
(c) One three pin 5 Amps socket outlet point controlled by one No one way switch on independant board .
All as per Item No. 62 above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
S & F for Modular switch one way 6 A, 1 module complete all as specified and directed.
S & F for Modular switch one way 16 A, 1 module, with neon indicator complete all as specified and directed.
S & F for Modular socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S & F for Modular socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S & F 6 amp of 3 module Popup Sockets for fixing in floor to match with floor surface complete all as specified and directed.
S & F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified and directed.
S & F celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified and directed.
S & F surface mounted, powder coated, die cast aluminium and anodized aluminium reflector with clear diffuser, fully adjustable for focus on walls/pictures, for better illumination as per site requirement all as per cat part no - LFCL01R010XC of Make Jaquar or equivalent model from the specified make given in PS Note : 7 Nos light fittngs to be connected through 01 no light point and switch.
S & F in replacement of LED light fittings 2'x2', 28 watts environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source 230 volts with all accessories internally pre wired and necessary mounting arrangements, complete all as per Make HAVELLS Cat part No. PLUTONEO2X2PLR28WLED840S (HSN 9405) 28 W or equivalent model from the specified make given in PS.
Supply and fix new generation, post top, energy saving, environmental friendly, long life aesthetically designed with symmentrical light distribution spun aluminium landscape luminaire with high power LEDs as light source of cap 35 watts complete with all accessories as per product code No CORALPT35WLED757PSYMTOPC of make Havells or equivalent model from the specified make given in PS.
Supply and lay GI Tubes of size 50mm dia, 'light grade', galvanised, with all fitting laid in trenches complete all as specified and directed.
S & F for MCB DB, 2 way single door SPN 240 volt fixed on wall including making good to disturbed surfaces and connecting with existing cable complete all as specified.
S&F MCB DB 8 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted all as specified and directed.
S&F MCB DB TPN 4 way double door with 200 amps rated busbar 415 V, all as specified and directed.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified and as directed.
S & F for MCB single pole and neutral of rated capacity 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified and directed.
S & F for MCB four pole of rated capacity 63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified and directed.
S & F for MCB double pole of rated capacity 20 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified and as directed.
M & L for Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn through and including non-metalic PVC, ISI marked and its accessories in PVC Conduits on wall/ roof/floor including one run of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor cable as earth continuty conductor along with the wiring and connection from DB to DB/ main board complete all as specified and as directed. Note:- 3 runs of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit length.
All as per item No 82 here-in-before but 2 runs of single core 4.0 sqmm with 1 run of single core 4.0 sqmm as earth continuity conductor. Note:- 3 runs of 4.0 sqmm cable and 1 run of PVC conduit shall be measured as one unit leangth.
All as per item No 82 here-in-before but 4 runs of single core 4.0 sqmm with 1 run of single core 4.0 sqmm as earth continuity conductor in and including PVC casing caping with all accessories. Note:- 5 runs of 4.0 sqmm cable and 1 run of PVC casing caping shall be measured as one unit leangth.
DAKSH ENGINEERS AND BUILDERS
PRASHANT CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .