Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 CrAccepted-AOC | ₹10.2 Cr Quoted ₹10.4 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹11.5 CrRejected-Finance VILL AZARA BHARALIPARA PO PS AZARA DIST KAMRUP M ASSAM PIN 781017 | KAMRUP METRO | ASSAM | 781017 | ₹11.5 Cr | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹12.4 CrRejected-Finance NOT SPECIFIED | ₹12.4 Cr | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹12.5 CrRejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹12.5 Cr | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹14.0 CrRejected-Finance | ₹14.0 Cr | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹10.5 Cr
EMD Value
₹8.5 L
Closing Date
19 May 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF OPS COMPLEX AND ASSOCIATED ATS INFRASTRUCTURE AT AF STN JORHAT
2023_MES_574706_2
88637/JOR/E8
Open Tender
Civil Works
760 days
GE AF JORHAT
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (AF) JORHAT
₹8.5 L
Yes
26 Jun 2023
20 Apr 2023
22 May 2023
20 Apr 2023
19 May 2023
5 May 2023
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
Construction of one block of Office and Administrative Accn for OPS Complexes in four storey (G+3) including Store room and ATC Building configuration with permanent specification including ramp ,Pile foundation, RCC framed construction, ATT, mosquito proofing seismic provisions, roof treatment etc all as directed and shown in drawings.
Construction of one block of Runway Controller Hut configuration with permanent specification including ramp , Pile foundation, RCC framed construction, ATT, mosquito proofing seismic provisions, roof treatment etc all as directed and shown in drawings.
Construction of one block of parking for Vehicle (Safety Bldg) for alternate ATC Bldg and Safety Ground Crew rest room in single storey configuration with permanent specification including ramp ,RCC foundation, RCC framed construction, ATT, seismic provisions, roof treatment etc all as directed and shown in drawings.
Construction of one block of Parking for four wheelers and two wheelers (for ATC Bldg) with permanent specification including ramp ,Pile foundation, RCC framed construction, seismic provisions, roof treatment etc all as directed and shown in drawings.
Construction of one block of Parking for CFT & MRS (Safety Bldgs) or ATC Bldg with permanent specification including ramp ,RCC foundation, RCC framed construction, seismic provisions, roof treatment etc all as directed and shown in drawings.
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (PCC ROAD/ HARDSTANDING/ RCC CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (ADDN/ ALTN TO BLDG AND OTHER B/R WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (AIR CONDITIONING AND REFRIGERATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (DEMOLITION/ DISMANTLING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIC SUPPLY M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed. Note :- GI wire upto 7.5 Mtr and testing od earthing shall be deemed included in the item.
S&F LED lamp 10 Watt surface mounted LED panel injection molded in thermally conductive engineered plastic all as specified and directed.
INTERNAL WATER SUPPLY S&F angle cock of 15 mm bore, cast copper alloy chromium plated with long shank and cap fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F Shower rose of 15mm bore, cast copper alloy chromium plated with long shank and cap fancy type, length 300mm complete all as specified and as directed.
PCC ROAD/ HARDSTANDING/ RCC CULVERT M&L for Providing and laying 150mm thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS 383, size of aggregate not exc 40 mm (grading and other parameters as per table 600-1 of MORTH, IRC SP 49 specification), design mix (minium cement content shall not be less than 200Kg/Cum) with 7 days compressive strength as 10N/Sqmm mixed in fully automatic computerized concrete batching plant, transported to site laid with sensor paver including spreading and compated by using 8 to 10 tonne vibratory roller including necessry formwork finishing etc all as specified and directed.
M&L for providing and laying 150 mm (compacted thickness) GSB-I of table 400-1 of Morth , IRC Specification, spreading in layers n. exc 15 cm thick,watering,ramming/rolling by tandem vibratory roller and finishing for achive field compection at least to 98% of MDD (Maximum Dry Density) of soil complete all as specified and directed by Engg-in-charge.
M&L for Providing and laying controlled quality cement concrete of minimum field flexural strength after 28 days 40Kg/Sqcm (Lower control limit - LCL) in pavement slab (thickness for slab 150 mm) with crushed stone aggregate including necessary form work, compacting, curing and brooming etc of slab along the joints and finishing surface of concrete pavement by belting and brooming without using cement content 350 kg/ cum (exact quantity to be as per Design Mix) complete all as specified and directed by Engg-in-charge
Supply and laying of polythene film, black in colour, 400 micron thick, laid in floor complete all as specified and directed. .
M&L for Forming 20mm thick Expansion joint for full depth of PQC / Quality Controlled Concrete with closed cell, medium density, cross linked polyethylene foam back up rod of 30mm dia, 25mm thick pre-moulded compressible filler board priming to 16mm with approved primer and filling with poly-urethane / polysulphide based sealant, applying masking tape on edge of joint to prevent accidental spillage of sealant and removing the masking tape after filling of sealant all as per the direction of the manufacturer, complete all as specified and as directed.
M&L for Forming dummy/contraction joint using diamond cutter with initial saw cut with 3mm blade soon after concrete sets for the depth of 100mm. Widening the first saw cut to 6 mm wide and 24mm deep from top priming top 15mm with approved primer, applying masking tape on edges of joint to pavement accidental spillage of sealant and filling with polyurethane/polysulphide based sealant to closed cell. Medium density, cress linked polyethylene foam back up rod of 8mm dia, for complete width of the joint, and removing the masking tape after filling of sealant and as specified and as per the directions of the manufacturer complete all as specified and directed.
M&L for Forming Construction joint 28mm deep x 10mm wide using diamond cutter with closed cell, medium density, cross linked polyethylene foam back up rod of 12mm dia, for complete width of the joint, priming to 15mm with specified primer and filling with polyurethane/polysulphide based sealant, applying masking tape on edges of joint to prevent accidental spillage and removing the masking tape after filling of sealant and as specified and as per the directions of the manufacturer complete all as specified and directed.
SEWAGE DISPOSAL M&L for RCC Soakage wells of size 2.25 M dia X 4.80 M deep, excavation in any type of soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber made of brick work in CM 1:4, RCC cover slab in M-25/ RR masonry/ filling with brick bats, complete all shown on drawing and as specified and directed.
BLANK
EXTERNAL ELECTRIC SUPPLY M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 45 x 45 x 5cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. Note:- GI strip upto 7.5m including testing is deemed included in the item.
M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. Note:- Copper strip upto 7.5m including testing consider in this item. .
M&L for Cable Junction Boxes out door type mounted on pole by MS clamp of suitable sizes, with metric knockout for cable entry of size 16/25 Sqmm , dimension of box are 205x255x112 mm complete with terminals all as specified and directed by Engr-in charge . Note : Contractor shall provide cable lugs and gland of suitable size for connecting cable in junction box.
M&L for street light bracket (suitable for street light fittings in poles) upto 1.5 RM , make out of GI pipe of light grade up to 40mm dia proper shaped, bend, threaded and drilling holes for wire entry and MS clamps (02 Nos) of suitable size in proper shape and sized all as specified and directed by Engr-in -charge.
M&L for PVC insulated three core 2.5 sqmm multistrand copper conductor for connection of Security light from junction box to Security light all complete as specified and directed.
Material & Labour for shifting and commissioning of existing 315 KVA transformer from existing plinth foundation to proposed site including construction of necessary platform of size 3.5x3.5x1.0 Mtr along with ramp and Chain link and fencing including of channel , angle, tee , section all as specified and directed by Engr in charge Note- (a) For shifting of transformer all the tools and plants and other accessories are to be arranged by the contractor at his own cost. (b) No damage should be done during shifting of transformer and if done shall be rectified by the contractor at his own cost. (c) Rates are including of shifting and construction of platform for mounting of transformer. (d) Rates of Chain link and fencing, channel , angle, tee shall be measured and paid separately in respective items.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology for passing the GI/HDPE pipe using ultra sounding technique and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and Fixing 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, to be Fixed in Existing Panels complete all as specified and directed.
Supply,installation,commissioning and testing of ( 1 LBS+2 VCB) 3 way RMU, extendible, motorized, outdoor type of rating 630 A aluminium busbar with a fault clearing capacity of 21 KA for 3 Sec, rated voltage 12 KV, operational voltage – 11 KV, frequency- 50 Hz, totally enclosed Ring Main Unit with IP 67 protection for SF6 tank and IP 55 protection for outdoor enclosure with self-powered microprocessor based numerical relay with over current and earth fault protection. Entire RMU should be tested for internal arc test of 21 KA for 1 Sec as per IEC 62271-200 standards. Self powered (3 O/C & 1E/F) relays with in built 11 KV CT'S 03 Nos) having CT ratio 50/1, accuracy class-1.0 for metering and 5P10 for protection purpose & 11 KV resin cast PT,s 03 Nos. The RMU unit should be designed, manufacture and tested according IEC 60694, IEC 62271-102, IEC 62271-100, IEC 62271-200, IEC 60265-1, IEC 60529. The ring main unit comprises of the following:- (a) Load Break switch should have the following:- 12 KV 630 A, Load break switch and earthing switch with making capacity " Live Cable" LED indicators through Capacitor voltage Driver mounted on the bushings Mechanical On/Off/Earth indication Cable testing facility without disconnecting the cable terminals Anti reflex operating handle. Cable box suitable for cable termination of 1 no.3Cx70 sqmm XLPE. Cable door should be arc proof and interlocked with respective earthing switches for safety operation. It should not be possible to open the cable and the cable door unless the switch is ON. Contd.....
Contd.. from serial item No. 36.00 (b) Circuit Breaker should have following each circuit breaker:- Manually operated 630 A VCB and earthing switch with making capacity Anti refex operating handel.Fault arc interruption should be in Vacuum only. Auxiliary contacts 02Nos and 2NC.3O/C +1E/F self powered relay with low and high set for over current and earth fault Relay should have facility to trip the breaker from remote commands without requiring shunt trip coil. Relay type REJ 603 of ABB or equivalent. Mechanical ON/OFF indication. Live cable indicating LEDs energized through capacitive voltage dividers. Cable box suitable for cable termination of 1 Nos 70 Sqmm 3 Core , XLPE Cable. (c) Metering:- (to be provided in separate chamber. 3 phase digital Amp meter 0-100 Amp including extra CT-03 Nos of suitable ratio for metering - 1 set 3 Phase digital volt meter for 0-12 Kv - 01 Nos Resin cast PT -01 set 3 Nos. Multi function meter for measurement of V,A,F Kva KW, pf-01 No. RYB indications -1 Set Manometer is essential to check the healtiness of the unit 01 No. Contd.....
Supply, installation, commissioning and testing Automatic intelligent power factor corrector (APFC) capacitor bank panel floor mounted ,weather proof made out of 3.15 mm thick CRCA sheet , out door type and structure duly fixed on structural channel, fixed on ground by PCC works ( 1:2:4 Type B-1 ) and net cementing the same, the cubicle panel should have enamelled danger notice plate, duly painted with coats of powder coated paint internally and externally on the surface all as specified and directed. The panel box should be cubicle shaped with special type of hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements incl necessary control circuit connections and necessary cable connections by lugs and glands incl provision to accommodating capacitor and the following electrical items:- Automatic power factor correction (APFC) Panel for 3 phase, 415 V & 50 Hz system of capacity 125 KVAR, 8 steps of ( 1x5 KVAR + 2 x 7.5 KVAR + 2x 12.5 KVAR + 2x25 KVAR + 1x30 KVAR) with MDXL capacitor and controller all as specified and directed by Engr-in-Charge. The APFC Panel comprising of following specifications : (a) MDXL type power capacitor with harmonic filter and 10% nonlinear load for 3 phase 440 V 50 HZ system of banking pattern 125 KVAR, 8 steps of ( 1x5 KVAR + 2 x 7.5 KVAR + 2x 12.5 KVAR + 2x25 KVAR + 1x30 KVAR) , Contd.....
S&F of cubical housing cabinet type LT panel board out door type, platform mounted factory made, totally enclosed dust and vermin proof open able from both front and rear side made out of 14 SWG (3.15mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors,GI earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) The panel should be suitable for 415 volts , 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:- BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. INCOMER (a) MCCB 500 amps, 415 volt, 50 Hz, 50 KA Breaking capacity with Thermal Magnetic release, 4 pole duly connected to bus bar As in coming -01 No. Contd.....
Contd.. from serial item No. 41.00 OUTGOING FEEDERS (a) MCCB 500 amps, 415 volt, 50 Hz, 50 KA Breaking capacity with Thermal Magnetic release, 4 pole duly connected to bus bar As in coming -01 No. (b) MCCB 250 Amp, 4 pole with breaking capacity of 35KA (Thermal setting 100%, Magnetic setting upto 70%) -1 No.(APFC ) INDICATING DEVICES (a) Digital Multifunction meter, Model C, class 1, with relay - 01 No. with Suitable CT and wiring. (b) Three indication lamp Neon type for three phase.
S&F of cubical housing cabinet type LT panel board out door type, platform mounted factory made, totally enclosed dust and vermin proof open able from both front and rear side made out of 14 SWG (3.15mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors,GI earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) The panel should be suitable for 415 volts , 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:- BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. INCOMER (a) 500 Amp MCCB of 4 pole, 415 V, 50 Hz, with breaking capacity of 50KA (Thermal setting 100%, Magnetic setting upto 70%) - 1 No. Contd.....
Contd.. from serial item No. 43.00 OUTGOING FEEDERS (a) 100 Amp MCCB, 4 pole , 415 V, 50 Hz with breaking capacity of 25KA (Thermal setting 100%, Magnetic setting upto 70%) - 1 No.(GF) (b) 125 Amp MCCB, 4 pole , 415 V, 50 Hz with breaking capacity of 36KA (Thermal setting 100%, Magnetic setting upto 70%) - 2 Nos.(FF & SF) (c) 200 Amp MCCB, 4 pole , 415 V, 50 Hz with breaking capacity of 36KA (Thermal setting 100%, Magnetic setting upto 70%) -2 Nos.(01 nos TF & 01 nos SB) (d) MCB TPN of capacity 20 amps with breaking capacity of 10KA - 01 No.( FOR S/LIGHT) (e) Time Switch (Astro Mini) 110 - 240 VAC 1 Phase - 2 W, 1 C/O, Base/DIN with accessories of 10Amps - 1 No. (f) power contactor - 1 No. (g) Bakelite cable connector - 1 No. INDICATING DEVICES (a) Digital Multifunction meter, Model C, class 1, with relay - 01 No. with Suitable CT and wiring. (b) Three indication lamp Neon type for three phase.
EXTERNAL WATER SUPPLY Material and labour for Construction of brick masonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as specified and directed.
Boring of holes under road, pavement,hard standing by excavation by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
ADDN/ ALTN TO BLDG AND OTHER B/R WORKS S & F Mineral fiber ceiling board 16mm thick 600x600 mm size incl grid 25 x 25 x 1.6mm thick GI powder coated angles 25 x 35 x 1.6mm size 'T' section fixed with 4mm dia suspenders from ceiling etc complete all as specified and directed.
S & F double layered 6 mm tinted glass with gas filled in the gap and fixed to aluminium frame complete all as specified and directed.
M&L Powder coated aluminium door using 96.6mm x 44.8mm x 1.6mm aluminium chowkhats 84.0 x 44.7mm x 1.6 section vertical styles 101.60 x 44.88 x 1.6mm rails including mortise lock vertical type mild steel 100mm size (Make godrej/Harrison) 02 Nos tower bolt 150mm, sliding bolt 30mm long 01 No, door handles and fittings on floor spring complete all as specified and directed by Engr-in-Charge bottom panel with 5 to 6 mm thick Aluminium composite panel top panel with 5.5 mm thick plain glass fixed with snap beading rubber of suitable size and each shutter n.exc 0.95 mtr in width complete all as specified and directed.
M&L stainless steel rectangular hollow section of any size and shape of ss Grade 304 in main member of stair case and steps of stair, post of shed, purlin, rafter and any similar structure suitable fixing arrangement/ fastner as per manufacturer instruction including ss welding, grinding and polishing complete all as directed by Engr- in- charge.
M & L stainless steel railing to stair case and similar location of SS grade 304 make of 40mm dia of wall thickness 01 mm in hand rails and 3 Nos 15 mm dia SS pipe of 01 mm wall thickness along the 40mm dia pipe at equal distance connected to baluster made of 30mm dia SS pipe of 1 mm wall thickness fixed to top of treads of steps with suitable fixing arrangement / fastners as per manufacturer instruction the balusters to be fixed at 600mm centre to centre at every alternate steps including SS welding, grinding and polishing complete all as directed by Engr -in -Charge.
AIR CONDITIONING AND REFRIGERATION S&F commissioning and testing air cooled split unit indoor/outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with 2.0 TR, BEE 5 star rated including suitable length of PVC water drain pipe complete all as specified and directed by Engr-in-charge.
S&F commissioning and testing air cooled split unit indoor/outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with 1.5 TR, BEE 5 star rated including suitable length of PVC water drain pipe complete all as specified and directed by Engr-in-charge.
S&F commissioning and testing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
S&F commissioning and testing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
Supply and installed Refrigerator double door electric driven (single phase) capacity 270 Ltr capacity, BEE 5 star rated complete all as specified and directed by Engr-in-charge.
M&L for making a new rain protection shed with angle iron of size 25x25x5mm thickness and inclusive galvanised, corrugated MS sheet with two corrugations side laps fixed with L- type or J-type hook, two coat of synthetic enamel painting over one coat of red oxide primer including preparation of surface complete, with necessary cutting /welding and nuts/bolts for fixing of ACs and shed on wall etc.all as specified and as directed.
M&L for feather - kits special coted wall mounting stand suitable for 1.5 to 2.0 TR split AC out door unit consisting of bracket 02 Nos , L angle - 02 Nos, MS 8x 50mm anchor fastener 6 Nos complete all as specified and directed by Engr-in-charge.
LIFT Supply, install testing & commissioning passengers lift for 08 passengers, machine room less speed 1.0 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve G + 03 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 2D infra red sensor in full height of door & built in announcing system. Details are as given below :- (a) Stops / opening - 4 stops and 4 openings ( All openings on the same side) (G+3), (b) Proposed Control - V3F control for hoist drive with PLC based logic controller, (c) Operation- Simplex full collective ( with / without attendant ), (d) Machine - Gearless traction M/C, (PMSM) directly placed on top of the hoist way, (e) Proposed Signal Details- (i) Combined luminous hall button with digital hall position indicator at all floors. ii) S.S car operating panel indicator with direction arrow, (f) Proposed Panel Enclosure- IP 54., (g) Car Enclosure - Stainless steel framed glass car panel on two sides ,designed back panel with decorated false ceiling, LED Light axial blower cabin fan Granite flooring, (h) Car Landing Entrance-Stainless Steel full vision glass Auto doors in car as well as in landing 900 mm opening., (j) Lift Well Size - 1900 mm (W)x 1900 mm(D), (K) Cage Size ( Inside Dimension )- as per IS 14665 (l) Door Operation- Automatic, (m) Auto Rescue Device (ARD) - Will be provided to bring the lift to the nearest landing in the event of a power failure.
DG SET Supply installation, testing and commissioning of silent diesel driven engine generating set with acoustic enclosure and outdoor AMF Panel of capacity 320 KVA /256 KW with liquid cooled engine 400 HP at 1500 RPM brushless frame heavy duty industrial type complete with all standard engine accessories including alternator coupled with engine and control panel with all other electrical components, fuel tank with level indicators (fuel tank with capacity for full load non stop 08 hours running of generating set), base frame coupling, RPM meter, hour meter, temperature gauge meter starting lead acid batteris of 12 Volts, two Nos, single initial changed, battery of capacity 180 Amp Hour including suitable size of copper cable with terminal leads, self starter 24 Volts, Alternator 24 Volts with ampere meter and all other mountings and accessories such as silence exhaust pipe wrapped with best quality asbestos rope including complete testing on 100% load for DG set including necessary PCC foundation of suitable size complete all as specified here-in-after and as directed. (I) ENGINE (a) General: Suitable four stroke compressed ignition, 400 BHP, 1500 rpm, radiator liquid cooled, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature. The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. Contd.....
Contd.. from serial item No. 60.00 (c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, electronically controlled fuel system with EFC control with digital electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement. (e) Cooling System: Should comprise of radiator with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free batteries to be mounted in trays (having rubber insulation) on the main frame with in-built charging unit. It should have the provision to charge the battery from external sources during static condition and while running of the generator. Contd.....
Contd.. from serial item No. 60.00 (II) AC Generator : The generator shall be horizontal and foot mounted, 320 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-21 enclosure class H insulation and temperature rise limited to class H as per following technical details (i) Type, Brush less AC Generators (ii) Output rating 320 KVA (iii) Output Voltage: 415 ± 1.5% under all loading conditions. (iv) Output frequency 50Hz ±1% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. vii) Enclosure : Minimum IP-21 ICO/ Drip proof and screen protected. (viii) Digital automatic voltage regulator. (ix) Class of insulation-'H' (x) Ambient operating temperature : up to + 30° C Note: Following shall be deemed to be included in cost quoted:- (i) Suitable RCC platform of size as required for outdoor installation with height as required at site to mount the generator as per manufacturer's recommendations. (ii) Disconnecting existing cables, from existing panels and connecting cables, cables glands, cable lugs to new panel complete with all necessary accessories. (iii) Install on the foundation, connecting fuel lines, cable etc. (iv) Test and commissioning complete (v) The cost of servicing including minor repair/ replacement such as topping up of coolant, engine/ lub oil, diesel as well as lub oil filters including periodical checking of complete DG set for for a period of one year or 500 running hours whichever is early. (vi) Pre-dispatch inspection at OEM Premises shall be carried out by rep of Accepting Officer. Contd.....
PROVISIONAL SUM Material & Labour for shifting of HT, LT, OFC/ CCTV cables to the location all as directed by Engineer-in-charge/User representative
PROVISIONAL SUM M&L for construction of 02 Nos of RCC Septic tank 50 users capacity design to carry sewage and sludge water, excavation in any type of soil , PCC (1:4:8) below foundation , RCC M-30 Design Mix in wall, Base slab, Buffle slab and roof slab including beam etc with vent shaft, manhole opening with cover connection etc., complete with effective depth of 1.5 mtr and overall depth of 3 mtr all as as specified and directed .
Note:- Schedule of credit (Sch 'A' Part- XIV) amount of Rs 2,02,973.00 shall be deducted from the total quoted amount of BOQ.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid