| 1 | L1₹5.9 LAccepted-AOC | ₹5.9 L | L1 | Accepted-AOC Being L1, Work has been awarded to M/s- COOL CONTROL CORPORATION |
| Sl No | Description | Qty | Unit | COOL CONTROL CORPORATION L1 |
|---|---|---|---|---|
| 1.01 | Servicing & cleaning of 1.5 TR window/ Split AC units by the cleaning agent / detergent i/c dismantling from window, cleaning / brushing and refixing in the same window etc complete as reqd. | 150 | Jobs | 1,27,500 ₹1,50,450 Lowest |
| 1.02 | S/charging of refrigerant gas for in the refrigerant circuit of existing SAC / WAC unit, vacumising and leak testing etc as reqd | 30 | Jobs | 96,000 ₹1,13,280 Lowest |
| 1.03 | Topup of refrigerant gas for in the refrigerant circuit of existing SAC unit, i/c leak testing etc as reqd | 30 | Jobs | 45,000 ₹53,100 Lowest |
| 1.04 | Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c brazing & making necessary addition/alteration , testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) | 2 | Jobs | 23,400 ₹27,612 Lowest |
| 1.05 | Replacement of faulty outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | 21,250 ₹25,075 Lowest |
| 1.06 | Replacement of faulty indoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | 18,750 ₹22,125 Lowest |
| 1.07 | Supply and replacement of fan blade of outdoor unit in the exsting split AC units including dismantling of the damaged fan blade etc complete as required | 4 | nos. | 4,600 ₹5,428 Lowest |
| 1.08 | supply and Replacement of contactor in the outdoor unit of split AC units for 230 Volt 50 Hz i/c connections testing etc complete as reqd. | 3 | nos. | 2,400 ₹2,832 Lowest |
| 1.09 | Rewinding of outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c dismantling, oiling, replacement of bush and reconnection testing etc as reqd. | 4 | nos. | 8,000 ₹9,440 Lowest |
| 1.10 | Repairing of PCB of indoor unit of 1.5 TR split AC units 230 Volt 50 Hz A.C. supply i/c dismantling of the burnt PCB including connection testing etc as reqd. | 3 | nos. | 4,500 ₹5,310 Lowest |
Tender Value
₹5.8 L
EMD Value
₹11,572
Closing Date
11 May 2026, 4:00 pmClosed
The Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
Call Basis Servicing/ repairing of air conditioners installed at various TE/ BTS Sites under BA Lucknow in Jurisdiction of ESD I,Lucknow
2026_BSNL_276154_1
08/TEDL/BSNL/2026-27, Dated 27/04/2026
Open Tender
Electrical Works
Item Rate
183 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER, O/o The PGMTD, BSNL, LUCKNOW
₹11,572
29 Jul 2026
29 Apr 2026
12 May 2026
29 Apr 2026
11 May 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Servicing & cleaning of 1.5 TR window/ Split AC units by the cleaning agent / detergent i/c dismantling from window, cleaning / brushing and refixing in the same window etc complete as reqd. | 150 | Jobs | - | - |
| 1.02 | S/charging of refrigerant gas for in the refrigerant circuit of existing SAC / WAC unit, vacumising and leak testing etc as reqd | 30 | Jobs | - | - |
| 1.03 | Topup of refrigerant gas for in the refrigerant circuit of existing SAC unit, i/c leak testing etc as reqd | 30 | Jobs | - | - |
| 1.04 | Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c brazing & making necessary addition/alteration , testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) | 2 | Jobs | - | - |
| 1.05 | Replacement of faulty outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | - | - |
| 1.06 | Replacement of faulty indoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | - | - |
| 1.07 | Supply and replacement of fan blade of outdoor unit in the exsting split AC units including dismantling of the damaged fan blade etc complete as required | 4 | nos. | - | - |
| 1.08 | supply and Replacement of contactor in the outdoor unit of split AC units for 230 Volt 50 Hz i/c connections testing etc complete as reqd. | 3 | nos. | - | - |
| 1.09 | Rewinding of outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c dismantling, oiling, replacement of bush and reconnection testing etc as reqd. | 4 | nos. | - | - |
| 1.1 | Repairing of PCB of indoor unit of 1.5 TR split AC units 230 Volt 50 Hz A.C. supply i/c dismantling of the burnt PCB including connection testing etc as reqd. | 3 | nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
08eNITCallbasisACESDI.pdf
Tender Documents • 1.88 MB
BOQ_322520.xls
BOQ • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].