| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAdmitted-Finance | ₹5.9 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | COOL CONTROL CORPORATION L1 |
|---|---|---|---|---|
| 1.01 | Servicing & cleaning of 1.5 TR window/ Split AC units by the cleaning agent / detergent i/c dismantling from window, cleaning / brushing and refixing in the same window etc complete as reqd. | 150 | Jobs | 1,27,500 ₹1.5 L |
| 1.02 | S/charging of refrigerant gas for in the refrigerant circuit of existing SAC / WAC unit, vacumising and leak testing etc as reqd | 30 | Jobs | 96,000 ₹1.1 L |
| 1.03 | Topup of refrigerant gas for in the refrigerant circuit of existing SAC unit, i/c leak testing etc as reqd | 30 | Jobs | 45,000 ₹53,100 |
| 1.04 | Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c brazing & making necessary addition/alteration , testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) | 2 | Jobs | 23,400 ₹27,612 |
| 1.05 | Replacement of faulty outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | 21,250 ₹25,075 |
| 1.06 | Replacement of faulty indoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | 18,750 ₹22,125 |
| 1.07 | Supply and replacement of fan blade of outdoor unit in the exsting split AC units including dismantling of the damaged fan blade etc complete as required | 4 | nos. | 4,600 ₹5,428 |
| 1.08 | supply and Replacement of contactor in the outdoor unit of split AC units for 230 Volt 50 Hz i/c connections testing etc complete as reqd. | 3 | nos. | 2,400 ₹2,832 |
| 1.09 | Rewinding of outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c dismantling, oiling, replacement of bush and reconnection testing etc as reqd. | 4 | nos. | 8,000 ₹9,440 |
| 1.10 | Repairing of PCB of indoor unit of 1.5 TR split AC units 230 Volt 50 Hz A.C. supply i/c dismantling of the burnt PCB including connection testing etc as reqd. | 3 | nos. | 4,500 ₹5,310 |
Tender Value
₹5.8 L
EMD Value
₹11,572
Closing Date
11 May 2026, 4:00 pmClosed
The Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
Call Basis Servicing/ repairing of air conditioners installed at various TE/ BTS Sites under BA Lucknow in Jurisdiction of ESD I,Lucknow
2026_BSNL_276154_1
08/TEDL/BSNL/2026-27, Dated 27/04/2026
Open Tender
Electrical Works
183 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER, O/o The PGMTD, BSNL, LUCKNOW
₹11,572
16 May 2026
29 Apr 2026
12 May 2026
29 Apr 2026
11 May 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1.01 | Servicing & cleaning of 1.5 TR window/ Split AC units by the cleaning agent / detergent i/c dismantling from window, cleaning / brushing and refixing in the same window etc complete as reqd. | 150 | Jobs | - | - | item1 |
| 1.02 | S/charging of refrigerant gas for in the refrigerant circuit of existing SAC / WAC unit, vacumising and leak testing etc as reqd | 30 | Jobs | - | - | item2 |
| 1.03 | Topup of refrigerant gas for in the refrigerant circuit of existing SAC unit, i/c leak testing etc as reqd | 30 | Jobs | - | - | item3 |
| 1.04 | Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c brazing & making necessary addition/alteration , testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) | 2 | Jobs | - | - | item4 |
| 1.05 | Replacement of faulty outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | - | - | item5 |
| 1.06 | Replacement of faulty indoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd. | 5 | Nos | - | - | item6 |
| 1.07 | Supply and replacement of fan blade of outdoor unit in the exsting split AC units including dismantling of the damaged fan blade etc complete as required | 4 | nos. | - | - | item7 |
| 1.08 | supply and Replacement of contactor in the outdoor unit of split AC units for 230 Volt 50 Hz i/c connections testing etc complete as reqd. | 3 | nos. | - | - | item8 |
| 1.09 | Rewinding of outdoor motor of split AC unit 230 Volt 50 Hz A.C. supply i/c dismantling, oiling, replacement of bush and reconnection testing etc as reqd. | 4 | nos. | - | - | item9 |
| 1.1 | Repairing of PCB of indoor unit of 1.5 TR split AC units 230 Volt 50 Hz A.C. supply i/c dismantling of the burnt PCB including connection testing etc as reqd. | 3 | nos. | - | - | item10 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
08eNITCallbasisACESDI.pdf
Tender Documents • 1.88 MB
BOQ_322520.xls
BOQ • 1.29 MB
Download all tender documents and submit your bid