Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹421.8 CrAccepted-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹421.8 Cr Quoted ₹550.0 Cr | L1 | Accepted-AOC Award Of Contract, Bidder is L1. |
| 2 | L2₹571.4 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹571.4 Cr | L2 | Rejected-AOC Bidder is L2. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 5 | Rejected-Technical D 1 1 GILLANDER HOUSE 8 N S ROAD KOLKATA 700 001 | KOLKATA | WEST BENGAL | 700001 | - | - | Rejected-Technical Technically Not Qualified |
Tender Value
₹402.1 Cr
EMD Value
₹2.0 Cr
Closing Date
28 Mar 2025, 2:00 pmClosed
S. E. (NMRDA)
S. E. (NMRDA) Station Road, NMRDA, Head Office, Sadar, Nagpur.
Construction of Dr. Babasaheb Ambedkar Super specialty Hospital and Post Graduate Institute for Medical Sciences at Kh. No. 101, 102 and 103, Mz. - Indora, Nagpur.
2025_NMRDA_1158337_1
e-Tender Notice No. 27/2024-25
Open Tender
Civil Works - Buildings
1095 days
Nagpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹50,000
₹2.0 Cr
NMRDA Nagpur
24 Jun 2025
7 Mar 2025
1 Apr 2025
7 Mar 2025
28 Mar 2025
7 Mar 2025
13 Mar 2025
Amount
A. EARTH WORK Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Hospital, MLCP & Service Block
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By MechanicalMeans
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 3.0m To 4.5 m.) By MechanicalMeans
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 4.5m To 6.0 m.) By MechanicalMeans
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 6.0m To 7.5 m.) By MechanicalMeans
Excavation for foundation in Hard-rock by controlled blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres. from the building area including dewatering and back filling with available earth soil /murum watering, ramming etc. complete. (Lift from 3.0 m To 4.5 m) By Mechanical Means
Excavation for foundation in Hard-rock by controlled blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres. from the building area including dewatering and back filling with available earth soil /murum watering, ramming etc. complete.(Lift from 4.5 m To 6.0 m) By Mechanical Means
Excavation for foundation in Hard-rock by controlled blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres. from the building area including dewatering and back filling with available earth soil /murum watering, ramming etc. complete. (Lift from 6.0 m To 7.5 m) By Mechanical Means
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface areacovering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete. Ground Floor
Disposal of all Types of Excavated Material Upto 5 Km Ground Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering andcompaction etc. complete. Ground Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Ground Floor
B. STRUCTURAL WORK
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Hospital, MLCP & Service Block
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Providing and laying Cast in situ/Ready Mix cement concrete M40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi , Retaining walls & OHT wall of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mix cement concrete M60 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Upto Plinth/ Ground level
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and laying Cast in situ/Ready Mixcement concrete M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
Providing and casting in situ / ready mix PCC M20 grade of trap metal for coping to head walls / parapet including centering, form work, compaction and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc )
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Upto Plinth/Ground level
Above Plinth/Ground level & including 1st slab
Above 1st slab & including 2nd slab
Above 2nd slab & including 3rd slab
Above 3rd slab & including 4th slab
Above 4th slab & including 5th slab
Above 5th slab & including 6th slab
Above 6th slab & including 7th slab
Above 7th slab & including 8th slab
Above 8th slab & including 9th slab
Above 9th slab & including (O.H.W.T. top level)
MASONRY WORK
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Upto Plinth
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
D. PLASTERING & PUTTY WORK
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor (Hospital & MLCP Terrace)
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
E. WATERPROOFING WORK
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Basement Floor, MLCP & Service Block
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 Basement Floor, MLCP & Service Block
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints ofNahani trap and any outlet by properly) etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
37a. Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
First Floor (Service Block Terrace)
Fourth Floor
Fifth Floor (Hospital & MLCP Terrace)
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing China Mosaic waterproofing over concrete / plastered surface of sloped roof, horizontal, vertical, curved surfaces, rounded vatas,sharp corners, junctions etc., using broken pieces of mono colored approved quality ceramic tile laid over and including 20mm thick cement mortar 1.3 screed mixed with approved waterproofing compound @ 2% by weight of cement, cost of all materials, labour, curing, breaking the tiles to the pieces of required size and shape, laying / fixing the tile pieces to the required line, slope, levels etc., providing extra screed as required for quick & easy flow of water, curing etc., at all heights including necessary scaffolding, cleaning the surface initially with saw dust and finally with acid all as per specifications etc. completed at all floors and heights as specified and directed by EIC.
First Floor (Service Block Terrace)
Fifth Floor (MLCP Terrace)
Terrace Floor (Hospital Terrace)
F. FLOORING WORK
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurrycleaning curing etc. complete.
Basement Floor
Ground Floor
First Floor
Terrace Floor
Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Basement Floor
Terrace Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing inC.M. 1:3 curing and cleaning etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
Basement Floor
Ground Floor
First Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Basement Floor
Ground Floor
First Floor
Providing & fixing 4mm thick Vinyl sheet for flooring confirming to IS 3462-1986 of approved make & colour/pattern for Flooring in correct level / slope at all levels/heights as per architectural drawings and manufacturer's specifications & instructions. Vinyl shall be fixed with approved adhesive properly, avoid bubbles in flooring including cleaning the surface, pressing the vinyl by appropriate roller properly, cutting and filling/ welding the joints by approved and matching colour welding rod properly etc. completed as per the instructions of the EIC. Joints shall be finished properly so that area shall look Continuously and joint less.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing & fixing 4mm thick Vinyl sheet for Skirting confirming to IS 3462-1986 of approved make & colour/pattern for Flooring in correct level / slope at all levels/heights as per architectural drawings and manufacturer's specifications & instructions. Vinyl shall be fixed with approved adhesive properly, avoid bubbles in flooring including cleaning the surface, pressing the vinyl by appropriate roller properly, cutting and filling/ welding the joints by approved and matching colour welding rod properly etc. completed as per the instructions of the EIC. Joints shall be finished properly so that area shall look Continuously and joint less.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc.complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground Floor
Providing and constructing granite kitchen / pantry platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying cement concrete flooring 50mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc. finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade
Basement Floor
Ground Floor
First Floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
G. JOINERY AND METAL WORK
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and Fixing of Mineral Fibre Suspended Ceiling System with Bioguard (Bevelled Tegular) EDGE TILES WITH 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 90%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 and 7), in module size of 600x600 x 16mm with Anti Microbial coating on the face of the tile, suitable for Green Building application, with Recycled content of 34%. The tile shall be laid on precoated G.I. channel on XL2 Clip having a web height of 32 mm 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner and 1200 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and pull out strength of 100Kilograms. . The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved at GRIHA and BS 476 etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7mm thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300mm, length ranging from 1500mm to 2660mm. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7mm as per in IS:513 (1994). Dimensions: The panel Length varies between 1500mm to 2660mm, panel Width shall be 300mm. The dimensional tolerances for length shall be ±1.0m up to 1000mm L; ±1.5mm between 1001 to 2000mm L; ±2.0mm between 2001 to 3000mm L. The dimensional tolerances for width shall be ±0.5m up to 300mm W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3mm(W) x 8mm(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30mm (H) and shall be bent appropriately bent as per the manufacturer’s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15mm for rigidity and vertical upturns of 40mm (for length ranging from 1251-2660mm).
Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400mm.
The difference between the two diagonal dimensions of the panel to be less than 1mm. The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98mm, and would require a plenum height of a minimum 450mm clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15mm, width of around 4” and gap between two planks around 3”. Crates to have layer separators of 1” x 2” dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200mm, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J-Bars (directional) shall intersect the U-profile at 90° at every module dictated by the panel length. The J-Bar is connected to the U-profile with a J-Bar hanger and secured to the matching square U-Profile slots using plug-in clips. Self-tapping screws to be used when square U-Profile slots do not match the hangers. The U-profiles and J-Bars be fastened to two adjacent walls using the wall anchor and bolts. U-Profiles and J-bars to be at a maximum distance of 450mm (max.) to a perimeter wall or outside edge of a floating module.
To join two pieces of continuous U-profiles and J-Bars, a U-Profile splice and J-Bar splice to be used respectively. Panel Installation: Full size metalworks R-H 200 panels (directional) to be hooked on to the J-Bars (in accordance with the shop drawings) along the short side (typical) to cover the span / width of the corridor. Field-cut Panels: Perimeter panels that require field cutting to fit on a wall trim option must have a minimum of 12mm edge resting on the horizontal surface of the wall moldings. Wall Moldings: 19x19 wall angle to be fastened to the perimeter using screws, at every 450mm to 600mm L. Warranty: The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings etc. complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
64a. Providing & fixing factory-made Single / Double leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Anchor fastener of HILTI make, SS Ball Bearing Butt Hinges, Recessed Oval flush pull handle & L-key lock (as per approved make) complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing, erecting & fixing 45 mm thick Double Leaf Solid Core Flush door shutter and frame having fire rating provision finished with Both side 1mm thk laminate of approved quality, colour, type, pattern on both sides, including providing & fixing 12 mm thk Teak wood lipping all around shutter as well as teak wood architrave at outer side of the door frame as shown in drawing providing water cut enamel paint of approved colour to door frame, architrave & shutter with all necessary consumables viz. adhesive, necessary hardware, necessary beads molding, lipping, fastenings, etc. completed at all floors and heights as specified and directed by EIC. (Rate including Fittings & Fixtures ) (Door shutter 120 min fire rated ) Fittings & Fixtures as per approved make a, SS Satin finish Hinges - 8 Nos. b, 20mm dia, 150mm long lever handle in SS finish (as per approved make) c, Hold open type door closer on 3/4th shutter (as per approved make) d, 250 mm Long Tower Bolt (12") from inside with SS finish e, Mortice dead lock package- full cylinder lock (45mm) on outer side & thumb turn on inner side (as per approved make) f, 300mm long concealed type tower bolt on 1/4th shutter (as per approved make)
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing, erecting & fixing one side openable clean room double/single door for OT room of GI powder coated frame size frame to frame 2400 x 1500 x 80/50 mm. technical specification, both side powder coated sheet of 0.8 mm thickness in side puff in filled materials density 40-42 kg/cubic meter. view glass provition as per choice, including door accessories: door closer, handle ,kike plate ,push plate and door etc. completed at all floors and heights as specified and directed by EIC. Second Floor
Providing, erecting & fixing 35 mm thick Double Leaf Solid Core Flush door shutter and frame finished with Both side 1mm thk laminate of approved quality, colour, type, pattern on both sides with Vision Panel, including providing & fixing 12 mm thk Teak wood lipping all around shutter, providing water cut enamel paint of approved colour to door frame & shutter with all necessary consumables viz. adhesive, necessary hardware, necessary beads molding, lipping, fastenings, etc. completed at all floors and heights as specified and directed by EIC. (Rate including Fittings & Fixtures ) Fittings & Fixtures as per approved make a, SS Satin finish Hinges - 8 Nos. b, Push-plate - 150mm wide push plate in SS finish (as per approved make) c, Kick-plate - 150mm wide kick plate in SS finish (as per approved make) d, 20mm dia, 300mm long pull handle 'D' Type in SS finish (as per approved make) e, Mortice dead lock package (45mm)- full cylinder lock on one shutter (as per approved make) f, 300mm long concealed type tower bolt on other shutter (as per approved make) g, Floor spring (as per approved make)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing, erecting & fixing 35 mm thick Single Leaf Solid Core Flush door shutter with Marine Ply finished with Both side 1mm thk laminate of approved quality, colour, type, pattern on both sides, including providing & fixing 12 mm thk Teak wood lipping all around shutter as per drawing providing water cut enamel paint of approved colour & shutter with all necessary consumables viz. adhesive, necessary hardware, necessary beads molding, lipping, fastenings, etc. completed at all floors and heights as specified and directed by EIC. (Rate including Fittings & Fixtures ) Fittings & Fixtures as per approved make a, SS Satin finish Hinges - 4 Nos. b, 20mm dia, 150mm long lever handle in SS finish (as per approved make) c, Mortice lock- emergency release with in & out indicator in SS finish (as per approved make).
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
67a. Providing, erecting & fixing 35 mm thick Single Leaf Solid Core Flush door shutter with Both side 1mm thk laminate of approved quality, colour, type, pattern on both sides, including providing & fixing 12 mm thk Teak wood lipping all around shutter as per drawing providing water cut enamel paint of approved colour & shutter with all necessary consumables viz. adhesive, necessary hardware, necessary beads molding, lipping, fastenings, etc. completed at all floors and heights as specified and directed by EIC. (Rate including Fittings & Fixtures ) Fittings & Fixtures as per approved make a, SS Satin finish Hinges - 4 Nos. b, 20mm dia, 150mm long lever handle in SS finish (as per approved make) c, Mortice dead lock package- full cylinder lock (45mm) on outer side & thumb turn on inner side (as per approved make) d, 300mm long concealed type tower bolt (as per approved make)
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Ground Floor
H. PAINTING WORK
Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC).
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and applying Acrylic Based External Texture Paint of Sherwin williams/ Asain or any other approved equivalent make, color & texture to external surface as per manufacturer's specifications and instructions. The surface shall be thoroughly cleaned off all mortar dropping, dirt dust, algae, fungus or moth grease and other foreign matter of brushing and washing ,pitting in plaster shall make good surface imperfections such as cracks , holes etc. should be repaired using white cement. Approval of the prepared surface to be obtained before commencement of painting work. P/a 2 mm thick synthetic plaster in approved texture and applied the approved color Paint with a brush on the texture in two coats over one coat of primer .Horizontal strokes shall be given , first and vertical strokes shall be immediately afterwards. This entire operation will constitute one coat. The surface shall be finished uniformly including scaffolding, labour, material and necessary painting apparatus, finishing and cleaning etc. completed as specified and as directed by EIC. at all heights and levels.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
I. MISCELLANEOUS WORK
Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Terrace Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Supply and installation of cubicles of width and depth as per Athena Lite- SS Series Cubicles- Std Sizes (W x D x H): 900 mm x 1550 mm x 2105 mm, (Height is including 100 mm gap from bottom, Door Width- 600 mm specifications/ site drawings). Cubicle height to be 2105 mm. Made from solid grade compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C, All doors will be of single colour and made of 12 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminium grade 6063 T5-50 micron epoxy powder coated for surface protection, Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section,Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.etc complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
78a. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Basement Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Ground Floor
Providing & laying POP of sufficient thickness over plastic sheets as a protective layer for flooring during the work including all maintenance, p/l plastic sheets, removing & disposing POP after the use, cleaning, etc. complete at all floors & as directed by the EIC.
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing car parking area column rubber guard / PVC - Acrovyn Corner Guards Size 100 x 100 x 8mm x 800 mm length and material approved by architects as direction of EIC.
Providing and fixing convex mirror Size 32" dia material approved by architects as direction of EIC.
Providing and fixing Rumbler Strips (Ramp area 1.5 m c/c) Size 100 mm wide x 25 mm height x 1000 mm Length) material approved by architects as direction of EIC.
Providing and fixing Speed breakers Size 350 x 500 x 50 mm material approved by architects as direction of EIC.
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.
Cutting down trees including trunks and branches with girths above 90cm to 180cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
Cutting down trees including trunks and branches with girths above 180cm to 270cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
Cutting down trees including trunks and branches with girths above 270cm to 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
Cutting down trees including trunks and branches with girths above 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any
Transplantation of trees (of various girth and heights as per survey drawings) including excavating the ground in the earth / murum / sand to the desired location, with required machinery. Tree to be lifted with roots & replaced in fresh soil. Making trench at suitable distance away from the stem based on age of the plant in a circular fashion to a sufficient depth to remove the ball of earth & applying fungicide on cut portion.
J. SITE DEVELOPMENT WORK
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed.
Supplying hard murum/ kankar at the road site, including conveying and stackingcomplete.
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side withvibratory roller including artificial watering etc. complete.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant MixMethod and Grading - I Material
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant MixMethod and Grading - II Material
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi / SWD wall of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
Providing and laying in-situ M35 Grade unreinforced plain cement concrete pavement with max 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 800mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram)
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from Other sources)
Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete.
Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.36a)
Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 30 cms. ( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.36b).
Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:- Murraya(Kamini);Bag Size 7'' x 8" (plants list) 1(a) serial no 15
Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms.(
Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.13)
Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.47)
Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.29)
Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23)
Maintainance of Newly Developed Shrubs Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31)
Providing on site required variety of Tree (free from weeds /diesease etc.) 30 cms. apart c/c.Name:- Bahava;Bag Size 13 x13'', ht 6- 8'(plants list sr no1,item no 5B)
Excavation pit size 0.60 x 0.60 x 0.60m for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.11)
Maintainance of Newly Planted tree varities having height 1mtr. - 2mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.34)
K. Façade & Canopy Work
General Notes: Supply & fixing in position at all floors integrated colour SDPC 60-80 microns (as approved by architect) matt finished aluminium work work for door, window, glazing. louver with extruded built-up standard sections of Jindal/ Gujarat Aluminium or other approved make conforming IS: 733 & IS: 1285 fixing with mechanical fasteners of required size, including filling up the gaps at junctions i.e. top, bottom & sides with required EPDM rubber / neoprene / weather sealant etc. Aluminium section shall be smooth, rust free, straight and jointed mechanically wherever required, including cleat angle, aluminium snap beading for glazing / panelling, stainless steel screws all complete. The Aluminium consisting of followings described as 'under: - All fixing shall be concealed. The finishes of the articles shall be as per architect's approval. EPDM / Neoprene purpose made beading shall be provided. Aluminium sections shall be T6 6063 alloy Fixing shall be with SS screws. All sections shall be extruded. All beading shall be snap on type. Glazing beading shall be from inside only. Minimum thickness of glass shall be 6mm when not specified. Anti-lifting device and rattlepad "Bottom rail shall be with self draining gutter section unless noted otherwise." Rollers as per approved make list Concealed locking arrangement. In louvered windows, extruded sections only shall be used.
All fitting and fixtures such as lever locks, handles, hinges, concealed tower bolts, door closer etc. shall be suited to sections and be of approved make. They shall be finished in matching coating or as approved. All casement windows shall have restrictor to restrict the opening of the window. Supply and fixing of aluminium work shall be carried out from 'approved agency. No separate payment shall be made for fittings such as locking arrangement, hinges, friction hinges, fittings and fixtures, gasket, fasteners, silicon restrictor, floor spring, anchors, handles, door closure, door stopper etc, Tenderer are required to consider the cost of all fittings, fixtures, locking arrangement, handles, peg stays, haslets, screws, hinges, fasteners etc while quoting the rate for unit weight of aluminum sections for window / door or even in Sqmt Prior to start of work supplier shall submit detailed full scale Shop drawings including plan, elevation and detail of fixing with structural calculation for approval of the EIC. Samples of each item on full scale or smaller scale as directed by the EIC shall be submitted for approval. Work shall proceed only on approval of shop drawing, samples of each extruded section, neoprene beading, gaskets, wool pile, fittings and fixtures by the EIC in writing. Elements have to be produced according to the measurement. WIND LOAD = 2 Kpa, as verified with IS-875, Part-III
Lower Floor Glazing - Wind Pressure 1.7 kpa
Curtain wall Glazing Design, Fabricate, deliver (to job site) and install structurally glazed system semiunitised glazing. The system to be pressure equalized, ventilated and drained. The mullion and transom should be made of Aluminium Alloy 6063 T6 with a face width of 52 - 65mm. Gap between the transom and mullion surface at the intersection would not be acceptable. The system should have a continuous base transom with suitable continuous EPDM base gasket. The system must be Non-insulated/ thermally insulated(if required as per tender) self-supporting aluminum façade system, with mullion/transom construction for multi-story façades with an internal and external face width of 52-65 mm. The system should accommodate 28mm DGU (6mm Heat strengthened glass + 16mm Airgap + 6mm FT glass) All exposed profiles should be SDPC to a minimum of 60 -80 mircons . All anchor fasteners to be made of SS 304 grade. All shims to be capable of transferring the load evenly and made of a suitable material (GI, Teflon etc) capable of lasting the life span of the system. All miscellaneous items to complete the system and make the system air tight and water tight such as peripheral sealants, backer rods, flashing, fasteners, brackets etc to be included in the rate. Glass: The glass panels to be glazed to an outer support frame with two part structural sealant make double adhesive tape along with application of weather sealant wherever applicable with all approved standard accessories and hardware. The outer frame will be fixed adapted profiles to the main frame. Silicone specifications are highlighted in the specifications manual. (Cost includes System with glass)
Ground Floor
First Floor
Second Floor
Third Floor
ACP at Spandrel Location 4mm ACP FR b1 (0.5mm coil + 3 mm Mineral Core + 0.5mm Alum coil). The rate includes the aluminium runners and cleats with non staining silicon All anchors shall be SS 304. The system which is non visible shall be cromotised (Stone finish as per archiect's intent)
Backpan Insulation 1.2 mm GI sheet + 48kg/m3 insulation glass wool with black veil
Fire Stop Smoke Seal by certified supplier Providing & fixing rock wool (Density: 100 kg / m3 min 100mm thk, according to suppliers recommendation) insulation of approved sample / make with intumescent sealant on top of it enclosed by a 2mm thk. G.I. sheet support with SS 316 screws. The system shall have a Z Clip of 100mm of 1.5mm thick at every c/c 300mm to hold the insulation in place . The top layer shall have a layer of Intumescent Sealant as approved by manufacturer .The whole system should be certified by the manufacturer The whole assembly will have a top GI cover of 2mm
Top Hung windows: Providing and fixing top hung openable window, ventilator shutters and partitions or stand alone etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . Openable Top hung windows including operating hardware and restrictor of make Securistyle/cotswold or as approved by Engineer-in-charge like two / four point locking arrangements with handle, self balancing friction stay, fastening kits rod ends , restrictors wedge at top etc all complete. Contractor to consider aluminium section required hardware including friction stays, locking arrangements etc Locking to be specified as per calculation. Size - 1200mm x 1550mm
Ground Floor- 81 Nos.
First Floor - 95 Nos.
Second Floor- 106 Nos.
Z Louvers Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Design Engineer fabricate and install the Z louvers as shown the drawings 221150 , Width - 103.2mm Height - 50.8mm. The louvers shall be extruded Aluminum profile of T6 6063 grade. The size of the tube which holds the louvers shall be 50mm x 100mm with Min 2mm Thickness. The plate on which holds the louvers shall be 3mm. The brackets required to hold the tube in place shall be of MS HDG 80 microns / or aluminum brackets . All prices like access to install the same shall be added in the price. Finish on louvers and all other aluminum section , plates shall be anodized 20-25microns Third Floor
Aluminim Horizontal Fins Design Engineer fabricate and install the horizontal fins as shown the drawings. The fins shall have a front extruded Aluminium fin as per arch shape of 6063 T6 grade and to be cladded with ACP.The size of the fins shall be as per concept drawings. The brackets required to hold the Fin in place shall be of MS HDG 80 microns / or aluminium brackets . The whole assembly shall be PVDF 30-40 micron . All prices like access to install the same shall be added in the price.
Aluminim Vertical Fins Design Engineer fabricate and install the vertical fins as shown the drawings. The fins shall have a front extruded Aluminium fin as per arch shape of 6063 T6 grade and to be cladded with ACP.The size of the fins shall be as per concept drawings. The brackets required to hold the Fin in place shall be of MS HDG 80 microns / or aluminium brackets . The whole assembly shall be PVDF 30-40 micron . All prices like access to install the same shall be added in the price.
Coping at top of 3rd Floor 4mm ACP FR b1 (0.5mm coil + 3 mm Mineral Core + 0.5mm Alum coil ). The rate includes the aluminium runners and cleats with non staining silicon All anchors shall be SS 304. The system which is non visible shall be cromotised (Stone finish as per archiect's intent)
Glass Railing at 3rd Floor Design engineer fabricate and install free standing railing. The glass railing shall be imbeded in aluminium channel which shall be continuous the anchors used shall be 12mm countersunk SS 316 anchors. The railing needs to from a certified supplier. Height 1200mm Glazing laminated Glass: 8mm FT + 1.52mm SGP/DG + 8mm FT
Staircase Glazing - Wind pressure 2 kpa Specification same as Sr. No. 110.01 (System with Vision Glass)
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Terrace Floor
Glass at Spandrel Location - 8mm FT Glass
Backpan Insulation - 1.2 mm GI sheet + 48kg/m3 insulation glass wool with black veil
Fire Stop Smoke Seal by certified supplier Providing & fixing rock wool (Density: 100 kg / m3 min 100mm thk, according to suppliers recommendation) insulation of approved sample / make with intumescent sealant on top of it enclosed by a 2mm thk. G.I. sheet support with SS 316 screws . The system shall have a Z Clip of 100mm of 1.5mm thick at every c/c 300mm to hold the insulation in place . The top layer shall have a layer of Intumescent Sealant as approved by manufacturer .The whole system should be certified by the manufacturer The whole assembly will have a top GI cover of 2mm
Top Hung windows: (only system cost) Size - 1500mm x 1000mm
First Floor- 8 Nos.
Second Floor- 8 Nos.
Third Floor- 8 Nos.
Fourth Floor- 8 Nos.
Fifth Floor- 8 Nos.
Sixth Floor- 8 Nos.
Seventh Floor- 8 Nos.
Eighth Floor- 8 Nos.
Aluminim Horizontal Fins Design Engineer fabricate and install the horizontal fins as shown the drawings. The fins shall have a front extruded Aluminium fin as per arch shape of 6063 T6 grade. The size of the fins shall be as per concept drawings. The brackets required to hold the Fin in place shall be of MS HDG 80 microns / or aluminium brackets . The whole assembly shall be PVDF 30-40 micron . All prices like access to install the same shall be added in the price.
Entrance Glazing - Conventional Curtain wall Glazing Design, Fabricate, package, deliver (to Job site) and install conventional curtain wall system , comprising of glass as shown in concept drawings (13.52 Laminated Glass- 6mm FT + 1.52 PVB + 6mm FT), The glass panels will be fixed mechanically with the help of pressure plate which will be fixed to the mullion with the help of SS 316 screws and then will be covered with a pressure cap with all approved standard accessories and hardwares. All aluminum extruded profiles shall be confirming to alloy T6 6063. All exposed aluminum profiles shall be anodized 20-25 microns approved shade. The curtain wall shall be sealed to the host structure and not adjoining materials with approved water proofing membrane and insulation to prevent sound transmission. The curtainwall glazed system design should be system proof with self draining properties. The System and glass is designed to withstand a wind pressure of 1.7 KPa at all levels, elevation & heights. The anchoring / bracing of the structural glazing to the RCC slab / beams / columns shall be done with non-corrosive hot dipped galvanized brackets of approved design (Galvanizing to be done confirming to IS:4759-1996 upto 610 gms. per sqm. (80-90 micron thickness) and including providing teflon shims of various thickness to adjust the beam level / line variations fixed with SS dash fasteners Hilti / Fischer make of min. 12mm dia. and depth of 50-80mm in the concrete and to withstand the dead load of the curtainwall glazing as well as stresses due to wind pressure etc.
Expansion joint gap for mullion shall be minimum 15 to 20mm. All screws used shall be only of stainless steel 316 grade. All bolts, nuts and washers used shall be only of stainless steel 316 Grade. Anchorage: Allow 3 dimensional movement in anchorage (bracket) design to absorb +/- 50mm host structure tolerances. The contractor must design the system as per the prevalent site conditions and building elevation profiles. No extra claims shall be entertained at any stage for aluminum profile wall thickness and size dimensions. Quote in compliance with Concept Drawings and specifications noted herein including erection & removal of scaffolding, cleaning the Facade & testing. Design, fabricate, package, deliver (to Job site) and install Fixed / operable windows comprising 6mm thk SGU glass as specified by the Architect). The contractor shall be follow the conceptual system for rates. The glass panels will be mechanically fixed to the aluminum main frame with aluminum beading from inside and frame shall fixed to steel / concrete with approved standard accessories. All aluminum extruded profiles shall be confirming to alloy 6063 T6. All exposed Aluminum profiles shall be anodized 20-25 Microns. The window shall be sealed to the host structure and not adjoining materials with approved water proofing membrane and Silicon with priming to avoid seepage and water ingress. (Cost includes System with glass) Double Height Glazing Ground Floor (Front Elevation)
Single Height Glazing Ground Floor (Elevation Left & Right)
Aluminium Cladding
First Floor
Extra for MS support
Double Leaf Swing Doors Extra Over above item :Double Leaf swing Doors With 12 mm thick toughened glass with floor spring/ pivot/ Handles of approved make .Cost to include cost of glass Door hande size 600mm on both doors. Door Size - 1800.mm x 2400mm - 8 Nos.
Canopies Glass Canopy Design, engineer, furnish, fabricate, package, deliver (to Job site) and install 8mm Clear HS+1.52SGP +8mm Clear HS fixed to MS work as shown in the architectural intent, The aluminium profles shall be SDPC 60-80 microns and the MS shall have finih of epoxy + 2 cats of PU paint. The price shall Include the price of peripheral flashings.
Entrance
Lobby - Left & Right
Connecting Building
Extra over for MS support
Upper Floors- Wind Pressure 2 kpa Casement windows Design, fabricate, package, deliver (to Job site) and install Fixed & 2 Side hung windows comprising 28 mm thk DGU glass as specified by the Architect). The contractor shall be follow the conceptual system for rates. The glass panels will be mechanically fixed to the aluminium main frame with alum beading from inside and frame shall fixed to concrete with approved standard accessories. Silicone specifications are highlighted in the specifications manual. All aluminium extruded profiles shall be confirming to alloy 6063 T6. All exposed Aluminium profiles shall be SDPC with 60-80 Microns and shade shall be as per architect's approval- AAMA 2605 15 years. The window shall be sealed to the host structure and not adjoining materials with approved Silicon with priming to avoid seepage and water ingress. Size - 3000mm x 1850mm (Cost includes System with glass)
Fourth Floor- 64 Nos.
Fifth Floor- 64 Nos.
Sixth Floor- 64 Nos.
Seventh Floor- 64 Nos.
Eighth Floor- 64 Nos.
Waiting Lounge Glazing Specification same as Sr. No.113 (Cost includes System with glass)
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Glass Railing Design engineer fabricate and install free standing railing. The glass railing shall be imbeded in aluminium channel which shall be continuous the anchors used shall be 12mm countersunk SS 316 anchors. The railing needs to from a certified supplier. Height 1200mm Glazing laminated Glass: 8mm FT + 1.52mm SGP/DG + 8mm FT
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eighth Floor
Ramp Glazing - Specification same as Sr. No.110.01 (Cost includes System with glass) System with Glass
Louvers at MLCP Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Aluminium louver screen with open joint system custom designed to withstand the design wind pressure confirming to IS-875 part III. The system shall be designed to accommodate aluminium tube of of size 50x100x3 mm thk. c/c 50mm as per drawings in open joint system using S.S. rods /pipe, anchor fasteners of approved make and as per structural requirement. The quote rate shall include all design, engineering & shop drawing approval from architect & consultant, mock-ups, smaple submission, handling of all mateirals (loading, unloading, shifting, etc). The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per Industrial standards.
The Total value of Schedule4
Description of Work / Item(s)
Amount
Providing and fixing of white european type wall-hung, Size 360mm x 360mm x 575mm with flush valve having flow rate upto 6.0 Litr / Minute of Jaquar / Cera / Hindware / Perryware or equivalent make including PVC soil pipe, vent pipe upto out side face of wall, 100mm dia PVC plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing of C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Providing and fixing of Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete.
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
Providing and fixing of Oval Type Under Counter Wash Hand Basin of 420x590x195mm size with pillar cock, C.P. Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection upto the out side face of the wall, having Telephonic Black/Colour Granite of 180mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. (For Kitchen)
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." (For Kitchen)
Providing and fixing of wall mixer with overhead shower, shower arm, hand shower with wall bracket having flow rate upto 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etc. complete as directed by Engineer In Charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing of C.P. Angular stop clock with wall flange of approved make continental ncluding necessary sockets/union nut etc. complete.
Providing and fixing of approved Instant type Electric water heater with heating element with thermostat, 2 Nos. 15 mm dia CP angle valve, pressure relief valve, non-return valve with CP copper connecting pipes with wall flanges etc., complete for pantries and shower areas with all inlets, outlets, valves and all other accessories etc.,complete. Capacity : 6 lts.
Providing and fixing of white glazed urinal with Pressmatic auto closing valve having flow rate upto 4.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make with P.V.C. waste pipe with fitting arrangement etc. complete as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Providing and fixing of 2 Nos. support arms and backrest to mounted on the track (vertically and laterally) for handicap toilet complete as required.
Providing and fixing of raised toilet seat with cover for handicap toilet
EXTERNAL WATER SUPPLY Supply, Installation, testing & commissioning in position the following heavy class UPVC SCH 80 pipes for under ground piping including all necessary fittings such as elbow, coupler & tee etc. Cost shall be inclusive of excavation, dewatering, backfilling, ramming surrounding the pipe around with minimum 150 mm thick compacted silver sand and providing thrust block at distance 2 M C/C. All work complete as per specification and satisfaction of the Project Manager.(Municipal water main to UG tank) 80 mm dia
Providing and fixing Wafer Type Butterfly Valves with Body of Cast Iron, Disc of Cast Iron/Stainless Steel and body lining of EPDM/Nitrile Rubber including jointing with Galvanised Iron pipes including hydraulic testing (Operating pressure not less than 20 Kg/Sq.cm) etc. complete as directed by the engineer-in-charge. 80 mm dia
Construction of Water Meter Chamber with 230mm thick C.C. solid block in CM 1:4 mixed with water proofing material over a bed of 150mm thick PCC (M20), walls plastered smooth, both inside and outside with CM 1:3, including curing. Excavation in all types of soil, necessary wooden/steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 meters. including ,lift, benching and channeling in PCC (M20) providing and fixing light duty Ductile Iron frame and hinged cover (of 600 x 900 mm, weight 65 kgs.) as per specifications and drawings.
Providing and fixing 80mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Effecting connection from Existing Water Supply line including necessary excavation & making good the same including cutting, boring and tapping the Existing line by providing and installing ferrule / Tee connections with necessary fittings as required and making good the same. The rate for this item also includes complete services from the contractor for liasoning works such as filing necessary applications, submission of forms for approval to the municipal authorities, depositing the fees / other amounts as required for getting the premises / installations, inspected and approved and all other formalities required till the water connection is obtained. All the expenses incurred in this regard shall be borne by the Contractor except for the official payments to be made for any security deposit etc. which will be reimbursed on production of original voucher.
Supply, Installation, testing & commissioning in position G.I. vent with brass mosquito proof coupling and air filter including return bend, complete as required. The entire fitting shall be hot dip galvanised.(for UG & OH tank) 50 mm dia
Supply, Installation, testing & commissioning of Heavy duty rungs in R.C.C. wall of water tanks etc. Including cutting, chasing the R.C.C. work and making good the same complete as required Polypropylene PVC rungs
Supply & installation of Ductile Iron Manhole Covers with frame of 600 mm dia (Light Duty) and 42 kg weight for OHT including all necessary supports, grouting of the frame in RCC, making arrangements for recessed locking of the Manhole cover etc. complete as directed by engineer-in-charge. (For UG & OH Tank cover)
Supply, Installation, testing & commissioning of 20mm dia. Automatic (RB) air release valve including providing and fixing cut off & drain valve, making necessary inlet/outlet connection and fixing with M.S.Brackets complete.
Providing, fixing, testing and commissioning of GI coated puddle plate sleeves with flanges of required length of below size all complete for walls of Underground and overhead water tank for pump suction, outlet and drain purpose etc. all complete.
250mm Dia (Fire pump suction)
65mm dia (Domestic & Flushing pump outlet)
50 mm dia (For OH tank, UG tank drain)
80mm dia (For OH tank outlet of Domestic & Flushing tank)
65mm dia (For OH tank outlet of Domestic & Flushing tank)
80mm dia (For OH & UG tank vent pipe)
100mm dia (For fire booster pump)
Effecting connection from Existing Water Supply line including necessary excavation & making good the same including cutting, boring and tapping the Existing line by providing and installing ferrule / Tee connections with necessary fittings as required and making good the same. The rate for this item also includes complete services from the contractor for liasoning works such as filing necessary applications, submission of forms for approval to the municipal authorities, depositing the fees / other amounts as required for getting the premises / installations, inspected and approved and all other formalities required till the water connection is obtained. All the expenses incurred in this regard shall be borne by the Contractor except for the official payments to be made for any security deposit etc. which will be reimbursed on production of original voucher.
110 mm dia. (4")
160 mm dia. (6")
Providing and constructing Brick Masonry inspection Chamber 90cmx45cm including 1:4:8 C.C foundation, 1:2:4 C.C. channels/halfround glazed stoneware pipe channel, saltglazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, with C.I. lead cover of 75 Kilogram with frame fixed in cement concrete.
Designing and constructing brick masonry inspection chamber with Heavy duty cover with varying depth & of the following sizes in brick work with of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embedded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, PVC foot rests at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required.(Contractor shall submit the structural design and drawings for the approval of Project Manager prior to execution). 600 mm dia top X 1200mm dia bottom
Providing and fixing 15cmx10cm salt glazed stone ware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brickmasonry chamber with cast iron lid and cast iron grating for the gully trap.
Supply, Installation, testing & commissioning of FRP manhole cover with frame tested as per BS EN 124:1994 and AASHTO H-20 and H-25.(Load bearing cap. upto 20 TN) Heavy duty of size 300 x 300 mm internal size with load bearing capacity up to 25 tones for Gully trap
Supply, Installation, testing & commissioning of rectangular stormwater channel of 230 mm thick wall in cement block or bricks in 1:5 cement sand morter, 1:3 cement sand plaster smooth inside & rough outside 100 mm (4") thick 1:2:4 PCC coping to fix the angle nosing at top, 100 mm (4)" thick 1:3:6 PCC at bottom, excavation, backfilling, bailing or pumping out etc. complete.( For entire plot SWD)
600 mm wide channel in slope 1:300 (In Ground Floor)
300 mm wide channel in slope 1:300 (In Basement, UG tank & STP pumproom)
Supply, Installation, testing & commissioning of factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm, reinforced with 8 mm dia four Each longitudinal & 9 Each cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 600X1000X50 mm wide channel in slope 1:300 (In Ground Floor)
Supply, Installation, testing & commissioning of cast irons grating with frame weight 75 kg. 300 mm wide channel in slope 1:300 (In Basement,UG tank & STP pumproom)
Supply, Installation, testing & commissioning of MS angle nosing fabricated out of 40 X 25 X 6 mm thick MS unequal angle with 20 mm dia. rod (round) x 75 mm long J shaped as per drawing welded at 600 mm C/C for anchoring for item No.2.1 above to fix grating.)
For Entire plot External SWD Channel drain
For Basement, UG tank & STP pumproom Channel
Providing, Constructing of catch basin chamber of the following sizes in brick work with bricks of class 35 in cement mortar 1 : 5 (1 cement : 5 find sand) necessary foundation concrete(1 : 4 : 8). Inside & outside plastering 12 mm thick with cement mortar 1 : 3 with a floating a coat of neat cement. Including the RCC top slab for fixing the grating including necessary excavation, dewatering, refilling, watering, ramming, removing, the surplus excavated material and making good the same complete as required.
Internal size 450 x 450 mm
Internal size 600 x 600 mm
Providing and Fixing Heavy Duty Catch Basin cover with frame tested as per IS 1726:1991
Internal size 450 x 450 mm
Internal size 600 x 600 mm
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
200 mm Dia
300 mm Dia
450 mm Dia
INTERNAL WATER SUPPLY & DRAINAGE Providing and fixing on walls/ ceiling/ floor CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.(Conseled cold & Hot Water Piping)
15 mm dia
20 mm dia
32 mm dia
Supply, Installation, testing & commissioning of approved make uPVC pipes of Schedule 80 with solvent cement joints including cutting the pipes to correct length providing and fixing with special PVC clamps, clamping on walls/floors, making good the same, testing, including providing an fixing with all types of UPVC fittings all complete. (Rate must be inclusive of fittings) (In Plumbing Duct)
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
Supply, Installation, testing & commissioning of approved make uPVC pipes of Schedule 80 (Terrace Looping) with UPVC fittings. Joints to be made to be fixed on walls of terrace parapet wall using proper hanger supports, grip bolts and clamps etc. as per specification & direction of Engineer-in-charge.
50 mm dia (UG tank to OH tank - OHTF pipe)
80 mm dia (Terrace Header)
Providing and fixing of insulation to concealed pipes by wrapping with videoflex insulation of 6mm with tapeing all complete 15 mm dia (Concealed hot water piping)
Supply, Installation, testing & commissioning of full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 15 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
15 mm dia (Down takes in Plumbing Duct)
20 mm dia (Down takes in Plumbing Duct)
25 mm dia (Down takes in Plumbing Duct)
32 mm dia (Down takes in Plumbing Duct)
40 mm dia (In down takes)
Supply, Installation & Testing of gun metal Gate valve with C.I. wheel of approved quality (screwed end) :
50 mm dia (In Down takes, OHTF Pipe & Tank drain)
65 mm dia (Down takes in Plumbing Duct)
80 mm dia (Down takes in Plumbing Duct)
PRESSURE REGULATION VALVE SET Supply, Installation, testing & commissioning of Compress PRV in supply pipeline with dia two control valves one union bypass with globe valve one side reduced. Nozzle with cocks and mounting pressure gauge.
50 mm dia
65 mm dia
AIR RELEASE VALVES (In Terrace Loop) Supply, Installation, testing & commissioning of 20mm dia. Automatic (RB) air release valve including providing and fixing cut off & drain valve, making necessary inlet/outlet connection and fixing with M.S.Brackets complete.
80 mm dia
110 mm dia (Soil & rain water pipe)
63 mm dia (Vent pipe)
80 mm dia (Waste pipe)
110 mm dia (Soil , Waste & rain water pipe)
160 mm dia (Soil , Waste & rain water pipe)
Supply, Installation, testing & commissioning of ASTRAL SILENCIO PP mineral filled low noise level Soil & Waste system as per EN 12056, with density 1.9 g/cm3 made from Polypropylene-M (mineral reinforced) and available from 40 – 200 mm with push fit rubber ring sockets for instalation.Pipe Should have a B1 fire classification according to EN 4102 and is hot water resistant up 95ºC short term loading (90ºC long term loading) and need to cut to required lengths and making proper connections of required depths. Pipes to be laid st basement ceiling level upto required depth including providing proper hanging arrangement and supports with all required accessories all complete and as directed by site incharge. (Pipe diversion at Basement ceiling level till Ground floor and servies floor)
63 mm dia ((vent pipe)
80 mm dia ( Waste pipe)
110 mm dia ((Soil, Waste & Rain water pipe)
160 mm dia (Soil, Waste & Rain water pipe)
200 mm dia (Soil, Waste & Rain water pipe)
Supply, Installation, testing & commissioning of Clean out ring and disc with three SS screw connecting to P.V.C. pipe all complete to the satisfaction and direction of the Engineer-in-charge.
110 mm dia
160 mm dia
200 mm dia
Supply, Installation, testing & commissioning of UPVC Aquarius Brand heavy class pipe for drain including providing and fixing necessary fittings such as elbows, tees union fittings etc. including cutting holes and pockets chasing in the wall or floors as required and making good the same to original conditions after concealing the pipes where required, lagging the concealed pipes with hessian cloth dipped in hot black bitumen, testing, all complete as per specifications of the following diameter. (for Sink, Wash basin drain and AC Drain)
32 mm dia (Wash basin drain)
40 mm dia (Sink Drain)
50 mm dia (Urinal & AC Drain)
Supply, Installation, testing & commissioning of UPVC Floor traps with jali etc. as directed by engineer-in-charge.
Providing and fixing of PVC P trap with jali etc. for ceiling suspended drainage as directed by engineer-in-charge.
PVC S & S P or S trap of 75 mm Dia
PVC S & S P or S trap of 100 mm Dia
Supply, Installation, testing & commissioning of P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
Supply, Installation, testing & commissioning of PVC dome shaped grating including making proper recessment, grouting with cement mortar 1:1 as per specification. (Rain water outlet at terrace) 160 mm dia
Supply, Installation, testing & commissioning of PVC jali for podium/Parking floor drain pipe including making proper recessment, grouting with cement mortar 1:1 as per specification. 100 mm dia
Hospital Building Nos. of Pumps : 2Nos. (1 working + 1 standby) Water Flow Rate : 345 LPM each pump (2Hrs of pumping) Head : 55 to 60 M Purpose : Domestic Water System Make : HBD / Grundfos/ Kirloskar
Parking Building Nos. of Pumps : 2Nos. (1 working + 1 standby) Water Flow Rate : 50 LPM each pump (30 Min of pumping) Head : 30 to 35 M Purpose : Domestic Water System Make : HBD / Grundfos/ Kirloskar
Hospital Building Nos. of Pumps : 2Nos. (1working + 1 standby) Water Flow Rate : 145 LPM each pump (2Hrs of pumping) Head : 55 to 60 M Purpose : Flushing Water System Make : HBD / Grundfos/ Kirloskar
Parking Building Nos. of Pumps : 2Nos. (1working + 1 standby) Water Flow Rate : 85 LPM each pump (1Hrs of pumping) Head : 30 to 35 M Purpose : Flushing Water System Make : HBD / Grundfos/ Kirloskar
40 KLD EFFLUENT TREATMENT PLANT FOR HOSPITAL ELECTRO-MECHANICAL EQUIPMENT "Design, Supply, Assembling motors , pumps , filters etc as required equipments including wiring , cabiling , contorl & operations panels as below , The scope is also inclusive of required Civil work duly certified by reputed Architect & RCC consultant, Vendor needs to consider cost for the same The cost also inclusive of 5 Year operation & Maintenace cost in shifts or as required any additional required items to complete the job as per OEM should be part of this scope "
SS Perforated, Corrugated Manually operated Coarse Bar Screen having 8-10mm Clear Spacing as per site requirement - 1no Raw Sewage Pump of capacity 2 m3/hr@10 mt head- (Horizontal self priming pump/Submersible as per site condition, MOC : Casing & Impeller in CI and Shaft is CS) (Make : Kirloskar/Wilo) SP0M - 2nos Agitator for Anoxic Tank (Shaft MOC : SS 304) (Make : Universal/ Veriyog) , 1No Coarse bubble disc diffuser / 150mm dia. / EPDM membrane / 1" external threaded & Fine Bubble Air Diffuser with 300 mm diameter / SILICONE based membrane/ made suitable for 3/4" external threaded (Make : SBS/Rehau) , 1 Lot Twin lobe, rotary Air blower (1W+1S) capable of delivering below mentioned flow of free air at required pressure driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply for Equalization Tank and MBBR Tank (40 m3/hr) (Make:Pehr/Usha) - 2nos MBBR media - CD-BF22, PP with UV stabilized. Dia 22mm, ht 16 mm, surface area 400 m2/m3 (Make : Cooldeck/MM Aqua) , 1 lot Sludge Recycle Pump- 2 m3/hr @ 10 mt head- Surface/ Submersible as per site condition (MOC: C+CI+CS) (Make : Kirloskar/Wilo)SP0M , 2nos Centrifuge Feed Pump- 2 m3/hr @ 10 mt head- Surface/ Submersible as per site condition (MOC: C+CI+CS) (Make : Kirloskar/Wilo) SP0M , 2nos Filter Feed Pump- 2 m3/hr@30 mt head - Surface/Submersible as per site condition (MOC: CI+CI+CS) (Make : Kirloskar/Wilo) KDS 335+ , 2nos Sand Filter including MSEP Vessel of 400 Dia x 1500 mm HOS (5 mm shell thk & 6 mm dish thk) with MS frontal piping , Media (Multigrade Sand), 40 NB Butterfly valves and other necessary arrangements , 1 set
Activated Carbon Filter including MSEP Vessel of 400 Dia x 1500 mm HOS (5 mm shell thk & 6 mm dish thk) with MS frontal piping , Media (Multi graded Sand & Activated carbon of IV 900), 40 NB Butterfly valves and other necessary arrangements , 1 set Sludge Dewatering Manual Top Discharge Basket Centrifuge (Outer Body MOC : MS Epoxy coated , Basket MOC : SS 304) with all fittings & other accessories Capacity : 5 litre/day (Make : J M Industries/Universal) , 1 set Chlorine dosing System (including Dosing pump (0-4 lph) , Make : E-Dose) and 50 ltr Dosing tank (MOC : HDPE, Make : Sintex) , 1 set Alum dosing System (including Dosing pump (0-4 lph) , Make : E-Dose) and 50 ltr Dosing tank (MOC : HDPE, Make : Sintex) . 1set Poly dosing System (including Dosing pump (0-4 lph) , Make : E-Dose) and 50 ltr Dosing tank (MOC : HDPE, Make : Sintex) , 1set Acid/Alkali dosing System (including Dosing pump (0-4 lph) , Make : E-Dose) and 50 ltr Dosing tank (MOC : HDPE, Make : Sintex) , 1set Ultraviolet disinfection unit (2 m3/hr) MOC : SS 316L on all wetted parts.(Make : Alfa) , 1set Design, fabrication, assembling, wiring of Non - Compartmentalized motor control centre , 1set Interconnecting Pipes, Valves & other fittings. Air piping MOC : GI C Class (Make : Jindal/Tata), Sewage line MOC : Upvc Sch 40 (Make: Astral/Prince/Supreme) , 1set Flexible/Armoured Cables , Connector, Cable Trays to make Electrical Installation Complete (Cable Make : polycab) , 1 set Civil / RCC work - Lot
420 KLD SEWAGE TREATMENT PLANT "Design, Supply, Assembling motors , pumps , filters etc as required equipments including wiring , cabiling , contorl & operations panels etc as below , The scope is also inclusive of required Civil work duly certified by reputed Architect & RCC consultant, Vendor needs to consider cost for the same The cost also inclusive of 5 Year operation & Maintenace cost in shifts or as required any additional required items to complete the job as per OEM should be part of this scope "
SS Perforated, Corrugated Manually operated Coarse Bar Screen having 8-10mm Clear Spacing as per site requirement , 1No Raw Sewage Pump of capacity 21 m3/hr@10 mt head- (Horizontal self priming pump/Submersible as per site condition, MOC : Casing & Impeller in CI and Shaft is CS) (Make : Kirloskar/Wilo) , 2no Agitator for Anoxic Tank (Shaft MOC : SS 304) (Make : Universal/ Veriyog) , 1no Coarse bubble disc diffuser / 150mm dia. / EPDM membrane / 1" external threaded & Fine Bubble Air Diffuser with 300 mm diameter / SILICONE based membrane/ made suitable for 3/4" external threaded (Make : SBS/Rehau) , 1 Lot Twin lobe, rotary Air blower (1W+1S) capable of delivering below mentioned flow of free air at required pressure driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply for Equalization Tank and MBBR Tank (420 m3/hr) (Make:Pehr/Usha) , 2nos MBBR media - CD-BF22, PP with UV stabilized. Dia 22mm, ht 16 mm, surface area 400 m2/m3 (Make : Cooldeck/MM Aqua) , 1 lot Sludge Recycle Pump- 15 m3/hr @ 10 mt head- Surface/ Submersible as per site condition (MOC: C+CI+CS) (Make : Kirloskar/Wilo) , 2nos Centrifuge Feed Pump- 10 m3/hr @ 10 mt head- Surface/ Submersible as per site condition (MOC: C+CI+CS) (Make : Kirloskar/Wilo) , 2nos Filter Feed Pump- 21 m3/hr@30 mt head - Surface/Submersible as per site condition (MOC: CI+CI+CS) (Make : Kirloskar/Wilo) , 2nos Sand Filter including MSEP Vessel of 1400 Dia x 2000 mm HOS (6 mm shell thk & 8 mm dish thk) with MS frontal piping , Media (Multigrade Sand), 80 NB Butterfly valves and other necessary arrangements, 1 set Activated Carbon Filter including MSEP Vessel of 1400 Dia x 2000 mm HOS (6 mm shell thk & 8 mm dish thk) with MS frontal piping, Media (Multi graded Sand & Activated carbon of IV 900), 80 NB Butterfly valves and other necessary arrangements, 1 set
Alum dosing System (including Dosing pump (0-10 lph) , Make : E-Dose) and 200 ltr Dosing tank (MOC : HDPE, Make : Sintex) 1 set Chlorine dosing System (including Dosing pump (0-10 lph) , Make : E-Dose) and 200 ltr Dosing tank (MOC : HDPE, Make : Sintex) 1 set Ultraviolet disinfection unit (21 m3/hr) MOC : SS 316L on all wetted parts.(Make : Alfa) 1 set Design, fabrication, assembling, wiring of Non - Compartmentalized motor control centre 1 set Interconnecting Pipes, Valves & other fittings. Air piping MOC : GI C Class (Make : Jindal/Tata), Sewage line MOC : Upvc Sch 40 (Make: Astral/Prince/Supreme) 1 set Flexible/Armoured Cables , Connector, Cable Trays to make Electrical Installation Complete (Cable Make : polycab) 1 set CIVIL WORK OF STP - 1 lot
M. AIR CONDITIONING SYSTEM (CENTRAL AC PLANT)
CHILLER Supply, installation, testing & commissioning of Air Cooled chillier with VFD, Harmonic Filters with R-134A refrigerant, having screw Compressors for each circuit, independent refrigerant circuit driven by suitable KW Sq.cage induction motor complete with condenser made with Aluminium fins and copper tubes, Condenser Fans with EC motor, shell and tube DX chiller with factory insulation, refrigerant piping, factory charged refrigerant , microprocessor based control panel and accessories etc. all mounted on M.S. frame with vibration isolator etc.Microprocessor based controller shall have Modbus/BacNet connectivity for third party BMS connection. Chiller should be with factory fitted Acoustic Enclosure to reduce the sound Pressure level to 78dBa at 1 Meter. Chiller should be having AHRI / EUROVENT Certification Minimum COP at AHRI Condition : 3.10 IPLV - 4.80 Operating Condition : Evaporator inlet temp.: 12°C Evaporator outlet temp.: 7 °C Evaporator fouling factor : 0.000018 MKS Ambient Condition : 44 °C Nagpur Condition Required Cooling Capacity at Design Condition : 400TR actual SITC of chiller to master and other to be slave with chiller Plant manager for sequencing, pump operation, equal chiller ,run time, compressor run time etc, optimization of chiller load etc. complete. Chillers to have seismic zone-3 Vibration Isolator & victaulic Coupling . Chillers with Low noise & compressor to have acoustical enclosures. Including Factory Test as per AHRI conditions for 1 chiller LOW SIDE
Primary Variable pumps-Design Envelope Split coupled vertical Inline pumps with Flow display Capabilities Supply, Installation,Testing and Commissioning of Design Envelope, Vertical split Coupled Single Stage, Single Suction type Inline Centrifugal Pumps suitable for variable Flow Chilled Water recirculation system, complete with C.I. Casing, Suction and Discharge connections shall be of same size and shall be supplied with matching flanges. pump casing should be factory preinsulated with Mech.seal.Impellers shall be made of Bronze/SS and shall be fully closed type. Pumps shall be dynamically balanced and two plane balancing is required for the pumps if impeller diameter is less than 6 times the width of the impeller. Pump Shaft shall be made of Stainless Steel, Coupling shall be rigid spacer type made of high tensile aluminium alloy, shall be designed for easy removal on site.The pump design shall meet the requirements of easy removal of mechanical seal components for servicing, replacement without disturbing the pump or motor. TEFC Sq.Cage non overloading type Motor with efficiency level of IE5. Mechanical Seal shall be Stainless Steel multi-spring with secondary seal, carbon rotating face and silicon carbide stationary seat. Gland plate shall be made of 316 Stainless Steel. Factory fitted flush line to the mechanical seal with maintenance free sediment separator. It should not require to disturb the motor and pump to replace the Mech Seal. Pumps will be supplied with head mounted integrated Variable Frequency Drives, VFDs (Graphical Display & IP66 rated) with Sensorless and Design Envelope Technology i.e. it should not require any DPTs to control the variable flow. Pumps should be with 5-10% redundancy in flow and head. Pumps should be PN16 rating. Operation Temp should be (-10 Deg C to 45 Deg C) Flow: 239 m3/hr (2-Working + 1-Standby) Head: 15 M Motor Rating: 15 kW With Suction Guide. With FTV.
Secondary Variable pumps-Design Envelope Split coupled vertical Inline pumps with Flow display Capabilities Supply, Installation,Testing and Commissioning of Design Envelope, Vertical split Coupled Single Stage, Single Suction type Inline Centrifugal Pumps suitable for variable flow Chilled Water / Condenser Water recirculation system, complete with C.I. Casing, Suction and Discharge connections shall be of same size and shall be supplied with matching flanges. Impellers shall be made of bronze and shall be fully closed type. Pumps shall be dynamically balanced and two plane balancing is required for the pumps if impeller diameter is less than 6 times the width of the impeller. Pump Shaft shall be made of Stainless Steel, Coupling shall be rigid spacer type made of high tensile aluminium alloy, shall be designed for easy removal on site.The pump design shall meet the requirements of easy removal of mechanical seal components for servicing, replacement without disturbing the pump or motor. TEFC Sq.Cage non overloading type Motor with efficiency level of IE3 Mechanical Seal shall be Stainless Steel multi-spring with secondary seal, carbon rotating face and silicon carbide stationary seat. Gland plate shall be made of 316 Stainless Steel. Factory fitted flush line to the mechanical seal with maintenance free sediment separator. It should not require to disturb the motor and pump to replace the Mech Seal. Pumps will be supplied with head mounted integrated Variable Frequency Drives, VFDs (Graphical Display & IP66 rated) with Sensorless and Design Envelope Technology i.e. it should not require any separate Logic Controller or DPTs to control the variable flow. Pumps should be with 5-10% redundancy in flow and head. Pumps should be PN16 rating and with BMS - Modbus/RS485/BacNet Flow: 363 m3/hr (2Working + 1-Standby) Head: 25 M Motor Rating: 38 kW With Suction Guide. With FTV.
Primary/Secondary Pumps logic controller IPS Controller Supply, Installation,Testing and Commissioning of Primary/Secondary Variable Pump Controller for Pump sequencing, staging with sensorless capability and Modbus connectivity with IP 65 enclosure. Controller suitable for 5 primary chilled water pumps and should not house any VFDs in it. VFDs should be offered as integrated to primary pumps itself and should not be housed in Panel. Primary controller should control by pass valve to ensure chiller minimum flow. Microprocessor based controller with pump software,fabrication of panel and control cabling etc.
For 3 Nos of Pumps mentioned above - Primary
For 3 Nos of Pumps mentioned above - Secondary
FLEXIBLE CONNECTIONS Supply,Installation, Testing & Commissioning of Double sphere flexible connector complete with frame / flanges, rust resistant springs, rust resistant bolts / nuts etc. to prevent transmission of vibration and sound etc. Supply,Installation, Testing & Commissioning of Double sphere flexible connector complete with frame / flanges, rust resistant springs, rust resistant bolts / nuts etc. to prevent transmission of vibration and sound etc.
On Chillers - 400 TR (2W+1SB)
On Pumps - Primary 400 TR (2W+1SB)
On Pumps - Secondary 400 TR (2W+1SB)
INDOOR UNITS Supply, installation, testing & commissioning of Floor mounted AHU (Double Skin) as per specification Fan section with DIDW type centrifugal impeller with the motor shall be permanent magnet external rotor motor with integrated electronics and suitable for continuous operation, Chilled water coils of copper tube and aluminum fins construction section with six rows deep having 12-13 FPI with coil face velocity of 500 FPM, Filter section with synthetic fiber filters in corrugated shape rated for filter face velocity 500 FPM Prefilter, & MERV 13 Rating filters.IE-3 motor (inside AHU casing), , spring mounted vibration Isolators, Limit Switch, Emergency Light, UV Emitter section with UVC Lamps, Guard for Inspection Door. AHU motor should be minimum IE4 grade along with the necessary controller hosed in a panel. The internal wiring between the limit switches,UV lamp & interlock to be part of AHU vendor scope. Fan Vendor should also provide the BacNet card for each AHU for BMS integration.Valve station with 4nos. of Butterfly valve, PIBC valve with microprocessor based controller & IBMS compatible, Y-strainer, Pressure Guage & temp. Gauge, Purge Valve.with necessary cabling upto 15m from VFD to motor as per OEM. Including Corded remotes, DP sensors for Filter & blower status, control wiring complete as required The air-handling units shall be as per specifications with extruded aluminum framework having panels with outer pre-plasticised 0.6mm G.I / Galvalume sheets & inner plain 0.6mm GI / Galvalume sheet having injected 23- 25 mm PUF of 38 -kg/Cum density in between. The drain pan shall be of 18 G SS with 13mm thick nitrile rubber insulation. The frame for AHU shall be extruded aluminum. The entire AHU shall be mounted on GI base of min 70mm. Drain pan: 1.2 mm thick SS304 with 25mm Nitrile rubber sandwiched. Provide 40 mm SS threaded drain nipple.
Dampers: Al. anodized low leakage aerofoil. Filter section: With Prefilter , Non-Combustible Filter, access doors filters in extruded al. box type frames with gasket arrangements around filter frames. This should include one set of commissioning filters Coil Section: Cu coils with hydrophilic coated al. fins,6 Row coil , CHW COIL Fan section: Centrifugal fans with access doors on both sides, inspection windows, limit switch to shut off fan on door opening, Emergency Light,UV Emitter section with UVC Lamp, VFD Starter Panel & cabling from control to fans shall be scope of HVAC VENDOR. Drive: IE-4 motor Vibration Isolators: For fans and mounting arrangements - Rust resistant spring Flexible connectors: Non flammable, weather and fungus proof
30000 CFM , 35mm of wg ESP St. Pressure
28000 CFM , 35mm of wg ESP St. Pressure
17000 CFM , 35mm of wg ESP St. Pressure
15000 CFM , 35mm of wg ESP St. Pressure
12000 CFM , 35mm of wg ESP St. Pressure
Supply ,Installation ,Testing and commissioning of Double skin Recirculating type Air Handling unit (Panel Thickness of 40mm+/-2mm) with thermal break profile complete with casing of hot dip G.I Casing of thickness of 0.8 mm pre -coated and pre -plasticized G.I for outer skin and 0.8 mm plain & G.I for Inner Skin encasing with 40mm polyurethane foam insulation having a density of 40 Kg. / CuM factory injected between them by injection moulding machine with thermal break profile for Air Handling Unit.unit shall be Ceiling / Floor Mounted type with 1 / 2 fans direct drive backward curved plug fan suitable for static pressure as required, with 2 stage filtration banks of With Electronic air cleaning Filters according to specifications as mention below & HEPA at Terminal, drive set , 8 row deep chilled water coil, 8 Row Deep Refrigerant DX-coil suitable to connect VRF/VRV ODU, Electric Heater Bank(For AHUs as mention below) for RH control, UVGI lamp with stand by in quantity for CHW coil (AHRI certified) & Refrigerant DX-coil (AHRI certified) as below specification, SS 304 insulated drain pan. The unit includes suitable class IE4 TEFC motor with IP55 protection, suitable for 415 +/- 10 % volt , 50 ±5% cycle , combined power supply variation of ±10%, 3 Phase AC supply , vibration isolators,Rubber pads (min 1 inch thick), canvas connection ,bulk head light, door limit switches as per specification/datasheet. AHU should supply with necessary VFD (Qty of VFD should be as per no. of Fan) . AHUs shall be fitted with Aluminum VCD's (Volume Control Damper) for supply /fresh air / purge air opening of AHU body with canvass connection. All supporting GI hangers, MS angles, channels nut , bolts, washers etc. necessary for unit installation shall be inclusive in the cost. All AHUs shall be suitable for Static Pressure as mentioned below. Vendor to consider the suitable size of FRLS power cable from panel to unit in scope of supply.
Supply, installation, testing and commissioning of the UVGI unit to be fitted upstream portion of Chilled Water coil & refrigerant DX- cooling coil of Air cooled condenser outdoor unit (for Cooling Coil Treatment & to Improve Indoor Air Quality ) with Reflector, lamp status display, audio-visual lamp failure alarm , lamp lifetime counter, lamp replacement reminder & SS stand.UVGI System shall be designed with scientifically developed UV sizing software in reference with CFD analysis & generate a report to prove the UV delivery of designed intensity.UVGI system for disinfection shall utilize high output UV lamp. The reflector shall "Dish Antenna” Shape to utilize 100% of UV & it MOC will be Anodized Aluminum. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more then 90%. System shall have a Dry Contacts or A 4-20 mA output shall also be provided for BMS compatibility. Control Power panel with necessary wiring & cabling to UVGI system unto 15 Mtr.length shall be inclusive in the cost. UVGI system shall be provided for following AHUS for Air capacities as mentioned below respectively.
SITC of Electronic air cleaner system that improves the indoor air quality through reducing PM 2.5 and PM10 based on Electrostatic precipitation technology which consists Two levels of filtration -firstly a washable aluminum prefilter which filters unto 10 microns, followed by a washable Electrostatic precipitation section (consisting of tungsten wires for ionizing and aluminum collector plates) where the filtration is unto 0.3 microns. Other forms of air filtration systems such as charged media filters, dielectric media filters, or ionizers (which do not have second stage collector plates) shall not be acceptable. The average capacity of the EAC shall be at least 1,000 CFM for the single cell unit and 2,000 CFM for the double cells unit. It should be a monoblock structured unit specifically designed for integration in Return Air path of the AHU, to centrally capture the pollutants. It should be equivalent to MERV13 or Higher efficiency with low pressure drop of not more than 75Pa @ 492fpm (as per ASHRAE 52.2). It should be UL Listed with in built provision to connect to BMS. Ozone level of units provided must be within the acceptable limit of 0.05ppm. The units shall have local LEDs at Nosindividual unit to indicate when the units are up for wash/malfunctioning. Efficiency in reducing micro - organisms to be above 90% and needs to be supported by a test report from a reputed lab. Tenderers must submit a Clause-by-Clause Compliance Summary and provide full documentation/technical literature/data sheets/reports to confirm compliance for Nosclause. Also the tenderer should have executed atleast one project with minumum 30 AHUs wherein these filters are installed and proven
The variable frequency drive shall be PWM type (Pulse width modulation) microprocessor based .The drive shall have a keypad control, a LCD display module, and manual ON/OFF switch and bypass switch. The VFDs shall have integrated, factory built metallic enclosures of IP 52 rating, without any de-rating. VFDs shall conform to the recognized international standards like IEC and manufactured according to ISO 9001, BS 5750 part 1 & 2 and shall be UL listed. The VFDs shall have internal harmonic filters on both limbs of the DC bus to reduce current harmonics and protection for Electronic motor overload, Protection to motor and VFD against input transients, phase loss, short circuit, under voltage, over voltage, phase imbalance, motor over temp., phase to phase short circuit or earth fault at motor terminals.VFD shall be ready for BMS .(VFD shall have lowest speed locking arrangement to maintain desired minimum ACPH inside the area). Interlocking terminals & control wiring for fire damper, motorized dampers etc. as per control scheme from panel to damper etc. Including suitable FRLS Power cable, Control Cabling & double run earthing , cable tray from starter panel to equipment's up to 15 mtrs length. All should be as mentioned in tender specifications.
8000 CFM /13.0 TR, 50mm of wg ESP St. Pressure
3800 CFM/15.0 TR , 50mm of wg ESP St. Pressure
3000 CFM/12.0 TR , 50mm of wg ESP St. Pressure
2400CFM /9.5 TR , 50mm of wg ESP St. Pressure
2300 CFM/9.0 TR , 50mm of wg ESP St. Pressure
2000 CFM/ 8.0 TR , 50mm of wg ESP St. Pressure
1500 CFM/10.0TR , 50mm of wg ESP St. Pressure-CSU
1000 CFM/6.7 TR , 50mm of wg ESP St. Pressure-CSU
Supply ,Installation ,Testing and commissioning of Double skin Recirculating type Air Handling unit (Panel Thickness of 40mm+/-2mm) with thermal break profile complete with casing of hot dip G.I Casing of thickness of 0.8 mm pre -coated and pre -plasticized G.I for outer skin and 0.8 mm plain & G.I for Inner Skin encasing with 40mm polyurethane foam insulation having a density of 40 Kg. / CuM factory injected between them by injection moulding machine with thermal break profile for Air Handling Unit.unit shall be Ceiling / Floor Mounted type with 1 / 2 fans direct drive backward curved plug fan suitable for static pressure as required, with 2 stage filtration banks of With Electronic air cleaning Filters according to specifications as mention below , drive set , 8 row deep chilled water coil suitable to connect VRF/VRV ODU, Electric Heater Bank(For AHUs as mention below) for RH control, UVGI lamp SS 304 insulated drain pan. The unit includes suitable class IE4 TEFC motor with IP55 protection, suitable for 415 +/- 10 % volt , 50 ±5% cycle , combined power supply variation of ±10%, 3 Phase AC supply , vibration isolators,Rubber pads (min 1 inch thick), canvas connection ,bulk head light, door limit switches as per specification/datasheet. AHU should supply with necessary VFD (Qty of VFD should be as per no. of Fan) . AHUs shall be fitted with Aluminum VCD's (Volume Control Damper) for supply /fresh air / purge air opening of AHU body with canvass connection. All supporting GI hangers, MS angles, channels nut , bolts, washers etc. necessary for unit installation shall be inclusive in the cost. All AHUs shall be suitable for Static Pressure as mentioned below. Vendor to consider the suitable size of FRLS power cable from panel to unit in scope of supply.
SITC of HEPA filter, Electronic air cleaner system that improves the indoor air quality through reducing PM 2.5 and PM10 based on Electrostatic precipitation technology which consists Two levels of filtration -firstly a washable aluminum prefilter which filters unto 10 microns, followed by a washable Electrostatic precipitation section (consisting of tungsten wires for ionizing and aluminum collector plates) where the filtration is unto 0.3 microns. Other forms of air filtration systems such as charged media filters, dielectric media filters, or ionizers (which do not have second stage collector plates) shall not be acceptable. The average capacity of the EAC shall be at least 1,000 CFM for the single cell unit and 2,000 CFM for the double cells unit. It should be a monoblock structured unit specifically designed for integration in Return Air path of the AHU, to centrally capture the pollutants. It should be equivalent to MERV13 or Higher efficiency with low pressure drop of not more than 75Pa @ 492fpm (as per ASHRAE 52.2). It should be UL Listed with in built provision to connect to BMS. Ozone level of units provided must be within the acceptable limit of 0.05ppm. The units shall have local LEDs at Nosindividual unit to indicate when the units are up for wash/malfunctioning. Efficiency in reducing micro - organisms to be above 90% and needs to be supported by a test report from a reputed lab. Tenderers must submit a Clause-by-Clause Compliance Summary and provide full documentation/technical literature/data sheets/reports to confirm compliance for Nosclause. Also the tenderer should have executed atleast one project with minumum 30 AHUs wherein these filters are installed and proven
The variable frequency drive shall be PWM type (Pulse width modulation) microprocessor based .The drive shall have a keypad control, a LCD display module, and manual ON/OFF switch and bypass switch. The VFDs shall have integrated, factory built metallic enclosures of IP 52 rating, without any de-rating. VFDs shall conform to the recognized international standards like IEC and manufactured according to ISO 9001, BS 5750 part 1 & 2 and shall be UL listed. The VFDs shall have internal harmonic filters on both limbs of the DC bus to reduce current harmonics and protection for Electronic motor overload, Protection to motor and VFD against input transients, phase loss, short circuit, under voltage, over voltage, phase imbalance, motor over temp., phase to phase short circuit or earth fault at motor terminals.VFD shall be ready for BMS .(VFD shall have lowest speed locking arrangement to maintain desired minimum ACPH inside the area). Interlocking terminals & control wiring for fire damper, motorized dampers etc. as per control scheme from panel to damper etc. Including suitable FRLS Power cable, Control Cabling & double run earthing , cable tray from starter panel to equipment's up to 15 mtrs length. All should be as mentioned in tender specifications.
Valve station with 4nos. of Butterfly valve, PIBC valve with microprocessor based controller & IBMS compatible, Y-strainer, Pressure Guage & temp. Gauge, Purge Valve.with necessary cabling upto 15m from VFD to motor as per OEM. Including Corded remotes, DP sensors for Filter & blower status, control wiring complete as required
11500 CFM , 50mm of wg ESP St. Pressure
10000 CFM , 50mm of wg ESP St. Pressure
9000 CFM , 50mm of wg ESP St. Pressure
7500 CFM , 50mm of wg ESP St. Pressure
6500 CFM , 50mm of wg ESP St. Pressure
6000 CFM , 50mm of wg ESP St. Pressure
5500 CFM , 50mm of wg ESP St. Pressure
5000 CFM , 50mm of wg ESP St. Pressure
3500 CFM , 50mm of wg ESP St. Pressure
Supply ,Installation ,Testing and commissioning of Double Skin Double Decker Air Handling Unit (Panel Thickness of 40mm+/-2mm) with thermal break profile complete with casing of hot dip G.I Casing of thickness of 0.8 mm pre -coated and pre -plasticized G.I for outer skin and 0.8 mm plain & G.I for Inner Skin encasing with 40mm polyurethane foam insulation (CFC & HCFC free) having a density of 40 Kg. / CuM factory injected between them by injection moulding machine with thermal break profile HRW- Air Handling Unit. Double decker AHU shall be with supply air fan & exhaust air fan and to be of Floor Mounted type (as specified) with 1/2 fans belt driven or direct drive backward curved Belt drive DIDW fan with VFD panel (VFD to be supplied by AHU manufacturer as per below mentioned detail /details are mentioned in separate line item), Two stage filtration banks of with 3 stage filtration banks of MERV 7 & MERV 14 ( Shall be mounted after fan section) filtration efficiency in Supply deck, 8 row deep chilled water coil (AHRI CERTIFIED), SS 304 insulated drain pan, Heat Recovery Wheel ( Enthalpy wheel).The Exhaust Deck shall be provided with Backward Curved Belt drive DIDW fan for exhaust application,Heat Recovery Wheel Section. HEPA at Terminal, VFD Drive to be provided for both Supply and Exhaust Blowers .The unit includes suitable (IE4) TEFC motor with IP55 protection , suitable for 415 +/- 10 % volt , 50 ±5% cycle , combined power supply variation of ±10%, 3 Phase AC supply , vibration isolators,door limit switches, canvas connection ,bulk head light, as per specification/datasheet. All fans should be AMCA rated . All empty sections in the AHUs shall be 600 mm deep. AHUs shall be fitted with Aluminum VCD's (Volume Control Damper) for supply/return/fresh air / purge air opening of AHU body with canvass connection.All supporting GI hangers, ,MS angles, channels nut , bolts, washers etc. necessary for unit installation,VFD panel as mentioned below shall be inclusive in the cost.Vendor to consider the suitable size of FRLS power cable from panel to unit in scope of supply. All AHUs shall be suitable for External Static Pressure as mentioned below :
The variable frequency drive shall be PWM type (Pulse width modulation) microprocessor based .The drive shall have a keypad control, a LCD display module, and manual ON/OFF switch and bypass switch. The VFDs shall have integrated, factory built metallic enclosures of IP 56 rating, without any de-rating. VFDs shall conform to the recognized international standards like IEC and manufactured according to ISO 9001, BS 5750 part 1 & 2 and shall be UL listed. The VFDs shall have internal harmonic filters on both limbs of the DC bus to reduce current harmonics and protection for Electronic motor overload, Protection to motor and VFD against input transients, phase loss, short circuit, under voltage, over voltage, phase imbalance, motor over temp., phase to phase short circuit or earth fault at motor terminals.VFD shall be ready for BMS .(VFD shall have lowest speed locking arrangement to maintain desired minimum ACPH inside the area)
Valve station with 4nos. of Butterfly valve, PIBC valve with microprocessor based controller & IBMS compatible, Y-strainer, Pressure Guage & temp. Gauge, Purge Valve.with necessary cabling upto 15m from VFD to motor as per OEM. Including Corded remotes, DP sensors for Filter & blower status, control wiring complete as required
3000 CFM /22.2 TR , 50mm of wg ESP St. Pressure
2600 CFM /19.8 TR , 50mm of wg ESP St. Pressure
2300 CFM/17.8 TR , 50mm of wg ESP St. Pressure
2000 CFM/15.0TR , 50mm of wg ESP St. Pressure
12000CFM , 30mm of wg ESP St. Pressure
10000CFM , 30mm of wg ESP St. Pressure
9500CFM , 30mm of wg ESP St. Pressure
8500CFM , 30mm of wg ESP St. Pressure
8000CFM , 30mm of wg ESP St. Pressure
7000CFM , 30mm of wg ESP St. Pressure
6500CFM , 30mm of wg ESP St. Pressure
6000CFM , 30mm of wg ESP St. Pressure
5500CFM , 30mm of wg ESP St. Pressure
5000CFM , 30mm of wg ESP St. Pressure
4500CFM , 30mm of wg ESP St. Pressure
4000CFM , 30mm of wg ESP St. Pressure
3000CFM , 30mm of wg ESP St. Pressure
2500CFM , 15mm of wg ESP St. Pressure
200CFM , 15mm of wg ESP St. Pressure
3500CFM , 30mm of wg ESP St. Pressure
7500CFM , 30mm of wg ESP St. Pressure
CHILLED WATER 4 WAY CASSETTE UNIT Supply, Installation, Testing and Commissioning of Ceiling Suspended Chilled Water 4 way Cassettes, EUROVENT Certified, complete with multi row chilled water coil, minimum 3 speed high efficiency fan motor, aluminium fins with corrosion resistant coating blue or golden, circular all direction throw type decorative grill, quiet high efficiency centrifugal fan, easily cleanable synthetic filter with minimum 20 micron mesh, inbuilt high lift condensate water pump fitted with an EPF drain pan, GI casing body designed to avoid vibration and condensation, provision for fresh air intake. Units shall be accessorised with a set of ball and ball valve with strainer along with flexible connection, hanging rods and accessories,Pressure Independent Control cum Balancing valve rating with minimum IP54 on/off type 230 volts .DN20 PIBCV ,DN20 - Upto 1.9 TR, DN20 HIGH FLOW- From 1.91- 3.3 TR, DN25 internally wired to the Cassette for feedback and control, cordless remote with digital display, hanging rods and accessories. The unit shall be suitable for operation with 230V/ 50 Hz/ 1 phase power supply with necessary cabling , controls and monitoring over BMS using Modbus/ Bacnet protocol, additional items and controllers complete as required.
0.8TR/ 325CFM
1.0TR/ 400 CFM
1.6TR/ 600 CFM
2.0TR/ 750 CFM
3.0TR/ 1200 CFM
4.0TR/ 1500 CFM
1.0TR/ 400 CFM (COMPACT)
0.8TR/ 325CFM (COMPACT)
HIGH STATIC FAN COIL UNIT ( FCU ) Supply, installation, testing and commissioning of ceiling concealed type High Static Duct type Fan Coil Units, Eurovent Certified, single skin, draw through type with minimum 3 speed fan motor, minimum 3 row chilled water coil, with Al fins with corrosion resistant coating blue or gold, metallic centrifugal blower, washable filter minimum 20 micron, insulated enclosed double skin drain tray, hanging rods and accessories, copper piping connections, etc. of the following capacities. Starter panel with necessary controls, incoming cable from starter panel to unit, Pressure Independent Control cum Balancing Valve, ball valve and ball valve with Y strainer and flexible connector, with minimum 24V Modulating Actuators (with anti blocking function) IP54 with 0-10VDC control, DN20 - Upto 1.9 TR, DN20 HIGH FLOW- From 1.91- 3.3 TR, DN25 - From 3.3 TR to 5 TR, Digital Thermostat with Modbus connectivity, Fire retardant canvass connections with GI powder coated finish angle flanges on both sides, etc. External Drain Pump with Additional auxiliary tray should accommodate all valves as per the specifications and approved drawings. The external static pressure shall be as per specifications below. The unit shall have provision for complete control, wiring and monitoring over BMS using Modbus/ BacNet protocol. Including corded remotes and FCU kits all accessories complete as required.
1600 CFM/4.0TR 100Pa ESP
2000 CFM/ 5.0TR 100Pa ESP
1200CFM/ 3.0TR 100Pa ESP
1000 CFM/ 2.5TR 100Pa ESP
800 CFM/ 2.0TR 100Pa ESP
HIWALL MOUNTED UNITS Supply, Installation, Testing, Commissioning of High Wall Mounted type Chilled Water based Fan Coil Units with energy efficient 3 speed motor, ABS plastic decorative casing, Low noise fan-motor combination, Synthetic washable filter, Semi Circular Chilled Water Cooling Coil & aluminium fins with corrosion resistant coating blue or golden, minimum 13 FPI, Copper tubes minimum 7mm dia, multi step design Coil section with minimum 2 Rows, an in-built factory fitted Pressure Independent Control cum Balancing Valve, ball valve and ball valve with Y strainer and flexible connector, with minimum 24V Modulating Actuators (with anti blocking function) IP54 with 0-10VDC control,DN20 - Upto 1.9 TR, DN20 HIGH FLOW- From 1.91- 3.3 TR, All piping are to be insulated with closed cell elastomeric rubber insulation. Unit shall be equipped with self diagnostic function, temperature display and supplied with Digital Display type cordless remote with 3 speed fan switch & Temp Edit facility & Digital Temp Display, supplied with relevant power supply cable from nearest point to to FCU as required along with external drain pump. Inbuilt BMS provision in the units as complete.
Supply, Installation, Testing & Commissioning of TREATED FRESH AIR UNITS cum Heat recovery unit Double skin Heat recovery air handling units made of Aluminum structure of 46+2mm thick Puf panel (Thermal Break) extruded aluminum profiles with 0.8 mm thick pre-coated GI Outer Sheet, 0.8mm thick Precoated GI. return air section with filter section with G4 filter, Aluminium Heat Exchanger with epoxy coating,return air should pass through wet scrubber to scrub the chemicals in the air. 18G SS304 Sump with required thickness internal UPVC piping, monoblock end suction pump to circulate water. Wet section of the scrubber unit to be internally 0.8 mm thick SS 304. Screws to be considred SS 304 consturction. Cross flow heat exchager to recover the heat minimum of 50% efficiency to be considered. blower section with SISW Backward Curved Multiple High Efficiency- Low Noise Plug type EC fans (N+1) with Epoxy/PPFRP anticorosive coating, Fan section access door, damper at the outlet of unit. Fresh air section to have inlet Aluminum louvers, fresh air section with MERV-13 filter. SISW Backward Curved Multiple High Efficiency- Low Noise Plug type EC fans (N+1) arrangment. damper at the outlet of unit Suitable controllers for EC Fans with internal wiring shall also be provided with the AHUs as per system's requirement.with required based structure supports & Necessary cabling as per OEM.
Frame structure: Extruded profile Al. anodized with thermal break Panels: Double skin panels 25 mm thick +- 2 puff. Inner skin: 20G GI plain Outer skin: 24G GI pre-coated Skid: GI epoxy coated Drain pan: 1.2 mm thick SS304 with 25mm Nitrile rubber sandwiched. Provide 40 mm SS threaded drain nipple. "Dampers: Al. anodized low leakage aerofoil. Shaft to accept motorized actuators." Coil Section: Cu coils with hydrophilic coated al. fins, 8 Row coil, Chilled Water coil, UV lamp Fan section: DIDW forrward curve fans & access doors on both sides, inspection windows, limit switch to shut off fan on door opening & Fan with PP FRP / Epoxy coating .with power cabling upto 15m from VFD to motor as per OEM. Prefilter & MERV- 4 & MERV 13 Filters Drive: IE-4 motor with VFD Vibration Isolators: For fans and mounting arrangements - Rust resistant spring Flexible connectors: Non flammable, weather and fungus proof Thermostat- with Control & communication cable from machine to thermostat TFA to operate on IBMS protocol for BacNet IP Factory fitted Insulated with Nitrile rubber 38 mm thick with 7mil cloth Valve station with 4nos. of Butterfly valve, PIBC valve with microprocessor based controller & IBMS compatible, Y-strainer, Pressure Guage & temp. Gauge, Purge Valve.
FMU-19500 CFM/127.0 TR /ESP 65 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-17500 CFM/114.0 TR /ESP 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-13000 CFM/84.5 TR/ ESP 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-10000 CFM/65.0 TR ESP 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-8500 CFM/ESP/55.5 TR 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-8000 CFM/ESP/52.0 TR 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
FMU-7000 CFM/45.5 TR/ESP 45 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
CSU-2800/18.5 TR CFM/ESP 30 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
CSU-1700 CFM/11.0 TR/ESP 30 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
CSU-1600 CFM/10.5 TR/ESP 30 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
CSU-1000 CFM/6.5 TR/ESP 30 mm - Vendor to take out actual ESP / TSP as per final duct length with MERV-13 Filter/43 mm thick +- 2 puff.
PPR-C & HDPE pipes Supply, Installation, Testing and Commissioning of PPR-C (Polypropylene Random copolymer) pipes of specified pressure ratings confirming to IS:15801 or equivalent standards for larger sizes, UV stabilized & anti-microbial fusion welded, having thermal stability for chilled water supply. Price includes all PPR-C fittings with PN25 rating like elbows, tees, reducers, sockets, metal flanges, couplings, adapters, end cap, brass threaded fittings, including PUF pipe support saddles and any other accessories as required to complete the installation. Pipes to be laid suspended from ceiling, in vertical shafts, on terrace, complete as specified in drawings, specifications and manufacturers recommendations.This includes factory and/or field testing complete as per direction of Engineer-in-charge.
PN - 10 Pipe, 315 mm OD (Mono layer)
PN - 10 Pipe, 250 mm OD (Mono layer)
PN - 10 Pipe, 200 mm OD (Mono layer)
PN - 10 Pipe, 160 mm OD (Triple layer)
PN - 10 Pipe, 110 mm OD (Triple layer)
PN - 10 Pipe, 90 mm OD (Triple layer)
PN - 10 Pipe, 75 mm OD (Triple layer)
PN - 10 Pipe, 63 mm OD (Triple layer)
PN - 10 Pipe, 50 mm OD (Triple layer)
PN - 16 Pipe, 40 mm OD (Triple layer)
PN - 16 Pipe, 32 mm OD (Triple layer)
PN - 16 Pipe, 25 mm OD (Triple layer)
Supplying, Installation, testing and commissioning of Polyethylene Pipes (HDPE) in standard lengths, confirming to IS 4984 / 14151 / 12786 / 13488 with all specials by compression fitting/electrofusion and butt fusion joint procedures as per relevant IS code complete with all materials for jointing procedure and necessary clamps & Supports , special fittings, couplers complete accessories as required Note:- H.D.P.E. Pipes shall be as per latest IS Specifications PE-100, 16 kg/sq.cm
Supply & Installation of Chilled water piping Insulation of 32 mm thick closed cell elastomeric nitrile rubber material of K=0.035w/mk and Moisture Diffusion Resistance Factor 'µ’ value should be minimum 7000 with 7mil cloth. The insulation shall have fire performance such that it passes Class 'O' as per BS 476 Part 6 and Class 1 as per BS 476 Part 7. The insulation shall be available in self-seal (pre-slit and pre-glued) pre-formed tube type for pipe diameter upto 4 inches. The Adhesive to be used as recommended by Manufacturer. The Application will be executed strictly as Specified by manufacturer. The Insulated Pipe shall be Wrapped with 5mili GC fiber cloth with resin followed by UV paint. (Vendor to verify thickness of Insulation suitable for Chilled water service) Insulation should include, Bends, TEE's, Elbows, Valves, NRV, Air vent, Air separator, Strainer and other accessories).All the Chilled water valves and Accessories to be provided insulation.
PN - 10 Pipe, 110 mm OD (Triple layer)
PN - 10 Pipe, 90 mm OD (Triple layer)
PN - 10 Pipe, 75 mm OD (Triple layer)
PN - 10 Pipe, 63 mm OD (Triple layer)
PN - 10 Pipe, 50 mm OD (Triple layer)
PN - 16 Pipe, 40 mm OD (Triple layer)
PN - 16 Pipe, 32 mm OD (Triple layer)
PN - 16 Pipe, 25 mm OD (Triple layer)
Supply & Installation of Chilled water piping Insulation of 50mm thick closed cell elastomeric nitrile rubber material of K=0.035w/mk and Moisture Diffusion Resistance Factor 'µ’ value should be minimum 7000 with 7mil cloth. The insulation shall have fire performance such that it passes Class 'O' as per BS 476 Part 6 and Class 1 as per BS 476 Part 7. The insulation shall be available in self-seal (pre-slit and pre-glued) pre-formed tube type for pipe diameter upto 4 inches. The Application will be executed strictly as Specified by manufacturer. The Insulated Pipe shall be Wrapped with 5mili GC fiber cloth with resin followed by UV paint. Insulation should include, Bends, TEE's, Elbows, Valves, NRV, Air vent, Air separator, Strainer and other accessories).All the Chilled water valves and Accessories to be provided insulation as complete.
DRAIN PIPING Supply,Installation, Testing & Commissioning of condensing Drain Piping with U trap, Drain Pans etc. Providing Rigid PVC Piping 6kg/cm2 with accessories , fittings,Traps, Reducer etc. & Civil supports, Clamps etc. as required. Drain piping to be insulated with 9mm 60 kg/m3 density Thick Nitrile rubber pipe sections with 7 mil cloth & cost of same is inclusive in this line item
Supply,Installation, Testing & Commissioning of G I 'C' class drain piping with elbows, bends, tees, cleanouts etc.with 9mm thick Nitrile rubber insulation with 7mil cloth. 40 mm
CHILLED WATER VALVES Supplying,fixing,testing & Commissioning of Butterfly Valve (Manual) with CI body SS disc, nitril rubber seal & O ring PN-16 rating for Chilled Water/Hot Water circulation as specified.
500 mm (Gear Operated)
300 mm (Gear Operated)
Supply, installation, commissioning & testing of Insulated Motorised Butterfly Valves with CI body SS Disc, PN 16 rating with CLASS 'O' NITRILE RUBBER.with 7 mil Cloth for mechanical protection with insulation thickness of 45 mm density of 40-60 Kg/ m3 with flanges, gaskets, bolts etc. Integrated with BMS/IoT including necessary controls and cabling as complete etc. 250 mm
Supply, Installation, testing & Commissioning of 150# C.S. Balancing Valve of PN 16 rating with Extended spindle to take care the Insulation Thickness as per Following Sizes, .All Valves will be Insulated using Nitrile Rubber insulation Material with fiber cloth and Thickness will be appx. 32mm for 7 Deg C & 50 deg C Service with all joining tape and accessories. Supply should include the required tubing and isolation valves so that the differential pressure may be measured across the Valve.
Supply, Installation, testing and commissioning of Bypass motorized valve with CI body SS Disc, PN 16 rating with necessary Temp. Sensor, Control, power cabling & necessary power cabling works.With CLASS 'O' NITRILE RUBBER.with 7 mil Cloth for mechanical protection ( Insulation thickness Up to 50mm 32 mm , 50 to 150 mm 38 mm, 150 to 250 - 45 mm ) density of 40-60 Kg/ m3, Integrated with BMS/IoT including necessary controls and cabling as complete etc. 250 mm
Supply, Installation, testing and commissioning of Insulated ball Valve with CI body SS Disc, PN 16 rating valves.With CLASS 'O' NITRILE RUBBER.with 7 mil Cloth for mechanical protection with insulation thickness of 32mm and density of 40-60 Kg/ m3
Supply, Installation, testing and commissioning of Non Return Valve with CI body SS Disc, PN 16 rating With CLASS 'O' NITRILE RUBBER.with 7 mil; Cloth for mechanical protection ( Insulation thickness Up to 50mm 32 mm , 50 to 150 mm 38 mm, 150 to 250 - 45 mm ) density of 40-60 Kg/ m3. check valves with flanges, nuts, bolts, gaskets etc. Check valves must be made of ductile Iron for flanged end and brass/ bronze for screwed end gun metal Seat, disc SS304 or equivalent with fusion bonded epoxy coating.
Supply, Installation, testing and commissioning of Insulated Pot Strainer with PN 16 rating , Ductile Cl Body flanged ends with stainless steel strainer for chilled/hot water circulation with 50mm thick nitrile rubber insulation. 500 mm
Supplying,fixing,testing & Commissioning of Y strainer of Ductile CI body flanged ends with Stainless Steel Strainer for Chilled/Hot Water circulation including Insulation as specified. Note : Insulation thickness should be same as the connected piping
Supply, Installation, testing and commissioning of Purge Valve 25 mm
Supply, Installation, testing and commissioning of BTU Meter of 500mm Dia. Along with its necessary controls & Cabling & BMS Compatible as per OEM
Supply, installation, testing and commissioning of a combined Air and Dirt Separator of M.S construction as per specifications on the return water line located at the pump suction or a suitable location as suggested. The separator should be complete with high capacity air vent, service valve, butterfly valve, water inlet, flanges, drain valve complete accessories as required to be insulated with nitrile rubber of 50mm thickness Connection size 500 mm- PN16 rating
Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Pressurization unit Supply, Installation, testing and commissioning of expansion tank with pressurization unit. The pressurization unit shall consist of two nos. (1 working+1 stand-by) high pressure pumps of suitable pressure rating mounted on M.S. frame, complete with interconnecting piping, isolation valves, NRV, Y-strainer, Pressure gauge, pressure transmitter, auto-logic panel(IP 65) with dry-run protection and other accessories complete. To be integrated with BMS System with MCB and necessary interconnection wiring. The unit shall be housed in powder-painted canopy suitable for external installation. Head 25 meter, Flow 2CMH
Supply,Installation,Testing and commissioning of Chilled Water Dosing System. Chemical feed system with Tank ,Canopy and Test kit complete as required Chemguard - 12000 - 3C Chemguard - 2100 - 2C
DUCTING & INSULATION Supply, fabrication, erection & commissioning of sheet metal ducting complete with factory fabricated ducts as per SMACNA/IS standards and GSM as per CPWD specifications. Measurement of GI SHEET METAL RECTANGULAR DUCT will be done outer to outer less insulation "Measurement of PRE INSULATED RECTANGULAR DUCT will be done inner to inner actual air flow. Quantity is based on inner to inner as per drawing. Vendor to incl. the rate of thickness also while quoting. Ducting should be ordered as per actual surface area with thickness by contractor." For Exposed areas ducts to be insulated internally with internal cross section open area (excluding insulation) as per requisite CFM. The ducts to be internally insulated using thermal insulation. Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal Rectangular/Round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. All Exposed Ventilation Ducts , Dampers & Supports shall be with Anti Corrosive painting and price should be extra.
GI- 24 gauge(Thickness 0.63mm sheet)
GI- 22 gauge(Thickness 0.8mm sheet)
Supply & Installation of Factory Pre-cut SMART Pre-Insulated CARE+ PIR Panels complete CFC & HCFC Free 20mm thick with 80 micron Embossed Aluminium foil on the outer side and 45 micron Embossed Aluminium foil on the inner side (Anti microbial, Anti fungal, Anti corrosion and UV Protection coating) and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7 with 2 hours fire rating, with Density of 45kg/m3 and should have Thermal Conductivity 0.021 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard and panel should be GreenPro & GRIHA certifed. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be with polymer slide in type joints with Patented Gasketed Bayonet between the ducts for zero leakages and polymer connecting flange (manufacturer make) to be provided for connection of branches, collars, droppers, etc. All polymer accessories to be of the same manufacturer. Measurement would be done on outer to outer. Supporting of Threaded Rod (6mm) & C Channel/ Wire supporting of reputed make recommended by Manufacturer to be provided.
20 mm Thickness (Internal Ducting)
30mm Thickness (Internal Ducting)
"Supply & Installation of Factory Pre-cut SMART Pre-Insulated CARE+ PIR Panels complete CFC & HCFC Free 20mm thick with 80 micron Embossed Aluminium foil on both Side(Anti microbial, Anti fungal, Anti corrosion and UV Protection coating) on the other side and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7 with 2 hours fire rating, with Density of 45kg/m3 and should have Thermal Conductivity 0.023 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard and panel should be GreenPro, GRIHA & EPD certifed. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be with polymer slide in type joints with Patented Gasketed Bayonet between the ducts for zero lekages and polymer connecting flange (manfacturer make) to be provided for connecection of branches, collars, droppers, etc. All polymer accessories to be of the same manufacturer. Measurement would be done on outer to outer. Supporting of Threaded Rod (6mm) & C Channel/ Wire supporting of reputed make recommended by Manufacturer to be provided." 20 mm Thickness (Internal Ducting)
Supply, Installation, testing and commissioning of GI Back Draft Damper complete with all necessary supports and anchors.
Supply, Installation, testing and commissioning of Flexible insulated Fibre glass ducting with supporting hangers, special clipping system complete etc 100 mm Dia.
Supply, Installation, testing and commissioning of automatic flow control device made of PVC / 16 G. GI with air flow set point and mechnciasum to control air flow with M.S Tie and all required support , compeletc, etc.
Supply, Installation, testing and commissioning of Powder coated GSS Louvres made of 16 G with bird screen, adjustable damper for fresh air and exhaust air etc.
Fresh Air (With Dampers)
Exhaust Air (Without Dampers)
Supply, Installation, testing and commissioning of Acoustic insulation for Duct with 10mm 24 Kg / cum density . Class 'O' Opened Cell nitrile rubber insulation Sheet with Adhesives & taping as complete as required.
Providing and fixing of adhesive thermal insulation for Underdeck duct with 25 mm thick nitrile rubber insulation with Class "O" & the insulation with 7 mills cloth for Mechnical protection (for Exposed Ducting)
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and retum air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required as per specification
Fire Dampers
Actuator
Supplying Installation , testing and commissioning of GI Volume control complete with neoprene rubber gasket , nut ,bolts, screw linkages , flanges etc. As per specification.
Supplying Installation , testing and commissioning of Alumium "0" leackage damper complete with neoprene rubber gasket , nut ,bolts, screw linkages , flanges etc. As per specification.
Supply,Installation, Testing & Commissioning of Flow Switch for Chiller with all necessary control cabling, BMS Compatible Etc.
Supply, Installation, Testing, & Commissioning of 12 - Hourly Sequential Timers along with the Necessary Wiring / Cabling for Timed Operation of the Stand-By AC Units.
Supply, Installation, Testing & Commissioning of Hydrogen Sensor, Controller for programming, scheduling the fans for auto ON based on the signal from Hydrogen sensor. Coverage area of Hydrogen sensor & qty of sensors should be as per Battery room requirements. Fan should also operate at predetermined time etc. alongwith the required accessories & Control cabling as specified. With IBMS connetivity to indicate H2 level on screen with Modbus / Back net IP protocol .
ALUMINIUM GRILLES / DIFFUSERS Supply, Installation, Testing & Commissioning of supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removeable core
Supply, Installation, Testing & Commissioning of Return air diffuser of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removeable core
Supply, Installation, Testing & Commissioning of Jet Nozzle with in built dampers 600mm Dia.
Supply,Installation, Testing & Commissioning of CO2 sensor with necessary cabling
Supplying & fixing of Powder coated extruder aluminium supply air grills with aluminium Volume control dampers as per specification.
Supplying & fixing of Powder coated extruder aluminium Return air grills with louvers but without Volume control dampers complete as required.
Supplying,fixing,testing,commissioning of aluminium louvers.
Supply, installation testing and validation of Aluminum made 18 gauge thickness factory fabricated front openable with counter sunked screws (for cleaning purpose) return air risers with inbuilt Aerofoil Zero Leakage Aluminum made volume control Damper and fitted with Aluminum made Zero degree inclination return air grills at front bottom. Return air risers sizes and location (preferably at 4 extreme corners of OT section) shall be suitable for following air CFM for proper laminar flow air distribution throught the OT section area. All necessary supporting SS-304 made structure, SS-304 made hangers, SS-304 made nut ,bolts, washers,SS-304 made channels, SS-304 made fasteners etc. shall be part of scope of supply. The contractor shall submit the GA drawing with technical specification before ordering for the OT risers.
For Return Airflow of 800 CFM
For Return Airflow of 900 CFM
Supply and Installation of Flow control Device for Fresh air with Control and complete accessories (Individual Rooms /Cabins)
Supply, installation, Testing & Commissioning of system that wirelessly integrates the data from individual wireless IAQ sensors to an IBMS platform. The data integrated into a MODBUS or BACNET systems. The adapter also stores a copy of the data collected from the individual sensors and visible via a software dashboard.
Supply, Installation, testing & commissioning of 1000 CFM- 2500 CFM fresh air measuring station with control & communication type device to operate on CO2 levels. as per specification & with actuator,Co2 sensor & aluminium damper to control Fresh Air as per IBMS, BACnet® controller with an integrated airflow sensor, Air flow sensor (0-2 inch) true differential pressure, Actuator, Comnnectors etc.with necessary control & power cabling
1000 CFM EXHU. 20 mm ESP
500 CFM EXHU. 20 mm ESP
2400 CFM EXHU. 20 mm ESP
2100 CFM EXHU. 20 mm ESP
1650 CFM EXHU. 20 mm ESP
Supply,Installation, Testing & Commissioning of Tube Axial Fans: For ventilation and also to operate during a fire event as per specs. Complete from OEM - back draft dampers, 1-D sound attenuators on inlet & outlet, non-flammable flexible connections,with Canvass Connection, Vibration Spring Isolator, base plate, single piece rouged construction , TEFC motor, epoxy coated , with Starter Panel with breaker and NO / NC contact for IBMS on Backnet IP protocol with control cabling. etc complete .(LOW NOISE ) Each fan to have its supports as spring isolators, required M.S works as per site conditions to install the fan. Fans to have additional sound insulation casing using 60 mm thick insulation and G.I sheet of 18 G on top of the fan.Fire rating 2 hours 300 Deg C.
20000 CFM /10mm ESP for Liftwell Pressurization
10500 CFM /25MM ESP 1400 RPM (Fans with 1 D sound attenuators on both side ) for Staircase Pressurization
10000 CFM/5MM ESP
9000 CFM/5MM ESP
8500 CFM/5MM ESP
8000 CFM/5MM ESP
7500 CFM/5MM ESP
6500 CFM/5MM ESP
6000 CFM/5MM ESP
5000 CFM/5MM ESP
2500 CFM/5MM ESP
Supply,Installation, Testing & Commissioning of PLC based electrical panel IP-65 rating with starters for all Axial Fans located in Basement Fan Incoming cables by others up to main Panel in electrical vendor scope, Including NO/NC Starter Panel, cables for all fans by HVAC vendors to be laid in only HEAVY DUTY cable trays. A. CO BASED , B. FIRE MODE, C. TIMER BASED. For Axial Fans located in Basement ventilation.
Supply and Installation of 300mm Dia. Propeller Fan and power cabling and NO / NC contact for IBMS on BacNet IP protocol with control cabling.
Supply,installation, testing & comissioning of double skin construction scubber unit for kitchen Exhaust.The unit shall comprise of Air intake section,SISW Centrifugal blower suitable capacityTEFCsquirrel cage,1440 RPM induction motor,drive package including multi scheme pulley belts, double bank spray header complete with water circulation pump tank along with GI 'B' class piping,strainer,fittings,eliminator,STARTER panel,Cabling,vibration isolators.etc. Motor with IP 55 Protection shall be considered. Air Quantity - 20000 CFM Static - 80 MM TSP (static and motor to suit site requirements)
Supply, centrifugal fan DIDW type fan section with forward curve & Canvass connection, motor, filter, starter, isolator cabling, dampers mounting arrangements. Spring isolators,10 micron prefilters etc. Air Quantity - 17000 CFM Static - 50 MM TSP (static and motor to suit site requirements)
Supply,Installation, Testing & Commissioning of FS cable from PLC panel to Fan. Cable Length with all termination & Glands
4 Core 10 Sqmm
4 Core 6 Sqmm
4 Core 4 Sqmm
3Core 1.5 Sqmm
Supply, Installation, Testing & Commisioning of outdoor condensing units, interconnecting refrigerant piping, (approx. Cu. cabling & refrigerant piping 15 M with 19mm Armacell insulation) controls, drain, copper earthing, single phase preventor, copper power & control cabling, Starter, safeties, condenser stand, all mounting arrangements etc.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
N. ELECTRICAL WORKS
SAFETY ACCESSORIES Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV
Supplying and fixing of First aid box as per I.S with necessary medicines & anticeptics cream medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal use, scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying and fixing of Shock treatment chart in Marathi , Hindi & English language in glass frame & fixed on the wall
Supplying and fixing of Caution Boards - 11 KV danger board made from vitreous enameled steel & to be fixed on wall/ shutter etc
Supplying and fixing of pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 22kV supply.
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
EARTHING & LIGHETNING ARRESTOR Supplying, installation and testing of earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying, installation and testing of earthing with Copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification No. EA-EP
Supplying, installation and testing of earthing with Galvanised cast iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification No. EA-EP
Supplying, installation and testing of earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Providing and laying and connecting the following sizes of Earth strips from the abovementioned Earth Stations to equipments complete using proper size hardwares
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification No (EA-EP) (25x6 strip)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP). (50x6 strip)
Supplying and erecting G.I. strip of required size used for kg earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP). (25x6 strip)
Supplying and erecting G. I. Earth Wire of high purity of different kg sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
LIGHTNING ARRESTOR- Vendor to design LPS & Structural earthing system as per IS/IEC -62305-3, considering Rooftop Solar Panels with Risk analysis
Supply, Installation, Testing & Commissioning of Aluminium Air Rod 16mm Dia X 3000mm Long with connectors to connect with 8mm alu conductor at parapet wall to meet the requirement of IS/IEC 62305.Item shall include mounting accessories like clamps etc on the wall to fix air terminal firmly
Supply, Installation, Testing & Commissioning of 8mm diameter Aluminium conductor (for loop on Perimeter) and on parapet wall (shall be Tested as per the standard IS/IEC 62305 and IEC 62561-2.
Supply, Installation, Testing & Commissioning of Conductor Holder for Round Conductors (Ø8-10mm) .
Supply, Installation, Testing & Commissioning of expansion piece with 2 no's connector for every 20m of the roof/terrace mesh as per IS IEC 62305.
Supply, Installation, Testing & Commissioning of Stainless steel 304 GRADE Cross connector for 8 mm Aluminium Round Conductor to connect with mesh on roof slope and meet the requirements for IS/IEC 62305
Supply, Installation, Testing & Commissioning of SS 304 GRADE Straight / Parallel Connectors for 8mm Conductor for interconnection of each coil at every 100mtrs to meet the requirement of IS IEC 62305.
Down Conductor Under Column IS/IEC -62305 -3
Supply, Installation, Testing & Commissioning of 8mm diameter Aluminium conductor (for loop on Perimeter) and on parapet wall (shall be Tested as per the standard IS/IEC 62305 and IEC 62561-2).
Supply, Installation, Testing & Commissioning of Conductor Holder for Round Conductors (Ø8-10mm).
Supply of SS304 GRADE Test link with suitable connector for 8 mm round Al conductor to 10mm copper bonded round conductor meet the requirement of IS/IEC - 62305.
Type B Earthing System ( GRID TYPE ) IS/IEC -62305 -3
Supply, Installation, Testing & Commissioning of 10 mm dia 250 Mic Copper bonding Conductor for connecting test link to earth pits. This shall be laid minimum 500mm below the ground level in soil and one metre away from the building retaining wall,
Supply, Installation, Testing & Commissioning of Stainless steel 304 GRADE Cross connector for 10 mm Conductor to connect with ring and meet the requirements for IS/IEC 62305.
Supply, Installation, Testing & Commissioning of SS 304 grade Connection clamp for 17-20mm Dia earth electrode and 10mm dia copper bonded conductor
Supply, Installation, Testing & Commissioning of G 20 Surge Protection Device, Type 1
Aviation Obstruction Light with special IP67 LED red colour for, Typical LED lifetime is more than 100,000 hours. Anti-knock and anticorrosion. It can be used in very rugged environment. Resistant to heavy rain or storms. Free maintenance and aluminium alloy Material. Integrated automatic flash synchronisation beam optical design, Independent design with integrated photocell, power supply flasher and monitoring
Supply, Installation, Testing & Commissioning of LA cable of 1 c x 70 Sq.mm PVC insulated (19 stands of 1.8mm dia) copper conductor cable - Black or Green insulated
LT WORK LT PANELS & DISTRIBUTION BOARDS Supplying, installation, testing & commissioning of following Indoor type, compartmentalized and sectionalized cubicle panel of suitable size, fabricated from cold rolled CRCA sheet steel of 2 mm thick , having vibration free structure chemically treated surface with seven tank process before painting, epoxy powder coated after two coats of anti-rust primer, making earth connections by providing copper earth strip of size 25 x 5 mm thick all along horizontal run of the panel suitable for operation on 3 phase 415 V 50 HZ AC supply i/c providing and fixing the following switchgear to be mounted thereon complete with gaskets, interconnections and earthing with suitable size PVC insulated FRLS copper wire .The panel shall be dust free, vermin proof and totally enclosed with Degree of protection of IP 54 as per IS 2147, with suitable cable/busbar alleys and shall be mounted on MS channels of size not less than 100 x 75 mm iron frame on floor etc as per specifications complete as required .Gland plates should minimum 3 mm thick and top and bottom.
The boards shall be treated with all anticorrosive process before painting as per standards with 2 coats of red oxide primer & final approved shade of powder coating. 2 nos. earthing terminals shall be provided for 3 phase distribution boards. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall be provided in case of large boards. Boards shall be fabricated in easily transportable sections & length, height, depth etc to match with site conditions. An approval shall be taken for each panel before final manufacture. Galvanised hardware with zinc passivation shall be used in fabrication of boards. Follow the detailed specifications at the time of fabrication.
Note: Panels Should have separate BMS / ELV/Fire trip compartment as per SLD Panels Should have Shunt Trip/ Fire trip as per SLD All CTs should have 5VA Burden, CL : 1 accuracy PCC Panel 1 & 2 to be manufactured as per Type Tested (TTA) & manufactured by OEM as per Form 3B and IEC 61439 Standard. Rest other panels to be manufactured as per Non-TTA & Form 3b Outgoings metering will be as per SLD & All Meters will be BMS compatible with accuracy Cl 1.0. All MCCB/ACB will have On/Off/Trip Indicating lamps with required control MCB All MCCB will have rotary handle All MCCB should have Ics=Icu 100% All MCCB should have spreader links. All MCB will be rated for 10KA breaking capacity & C'curve characteristics MCB in capacitor panel & Computer DB should be with D'curve characteristics All out door panels shall be IP65 with double door , canopy & small panels with 450-600 mm high stand
TRAFO O/P PANEL (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1 set Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 3 Nos and 4000/5 CTs - 3nos - 02 Set SPD -50KA type 1 & 2 BUSBAR : 3200A,TPN tinned Copper Basbar , suitable for 65 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves OUTGOINGS - 3200Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1 set 10000Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1 set Cable tremination box / chamber to be made considering quantities of all incoming & outgoings cables
MAIN LT PANEL will be Type Tested & manufactured by OEM as per Form 3B and IEC 61439 Standard. INCOMER 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…4set BUS-COUPLER 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1set Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 4nos - 04 Set And MCBs 2Nos and 2000/5 CTs - 2nos -02 Set SPD -65KA type 1 & 2 - 2 NOS BUSBAR : 3200A,FP tinned Copper Basbar , suitable for 65 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves OUTGOINGS - 3200Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), with KWH Meter ,BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1set 1000Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), with KWH Meter , BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…5set 800 Amp TPN MCCB,36 KA, (Ics= 100% Icu) with with Microprocessor based LSIG release- 02 Nos 400 Amp FP MCCB,36 KA, (Ics= 100% Icu) with with Microprocessor based LSIG release- 04 Nos 250 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Thermal Magnetic Release- 2 Nos 200 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Thermal Magnetic Release- 01 Nos Cable tremination box / chamber to be made considering quantities of all incoming & outgoings cables
MAIN LT PANEL -02 MAIN LT PANEL will be Type Tested & manufactured by OEM as per Form 3B and IEC 61439 Standard. INCOMER 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…4set BUS-COUPLER 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1set Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 4nos - 04 Set And MCBs 2Nos and 2000/5 CTs - 2nos -02 Set SPD -65KA type 1 & 2 - 2 NOS BUSBAR : 3200A,FP tinned Copper Basbar , suitable for 65 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves OUTGOINGS - 3200Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), with KWH Meter ,BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1set 1000Amp 4P ACB 50 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), with KWH Meter ,BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…5set 800 Amp TPN MCCB,36 KA, (Ics= 100% Icu) with with Microprocessor based LSIG release- 02 Nos 400 Amp FP MCCB,36 KA, (Ics= 100% Icu) with with Microprocessor based LSIG release- 08 Nos 250 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Thermal Magnetic Release- 05 Nos 200 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Thermal Magnetic Release- 02 Nos 160 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Thermal Magnetic Release- 03 Nos Cable tremination box / chamber to be made considering quantities of all incoming & outgoings cables as per SLD .
HYBRID APFC Panel-400KVAr + 50KVAR ASVG (Non TTA as per Form 3B and IEC-61439 Standard. ) Incomer - 800 Amp FP MCCB,36 KA, (Ics= 100% Icu) with with Microprocessor based LSIG release- 01 Nos OUTGOING : Stages for APFC 50 KVAr Heavy duty Capacitor Bank APP type with 125A TP MCCB & Capacitor duty Contactor & Al detuned Reactor - 02 set 25 KVAr Heavy duty Capacitor Bank APP type with 63 A TP MCCB & Capacitor duty Contactor - 04set 10 KVAr Heavy duty Capacitor Bank APP type with 63 A TP MCCB & Capacitor duty Contactor - 04set Busbar :1600A,TPN tinned Copper Basbar suitable for 50 KA for 1 sec 1 Sets of Metering Compartment with 16 Stage Intellegent APFC Realay , RYB Indicating Lamps of LED Clustered type and Control MCBs shall be provided. "Modular / Bolted Constructions, Foldable Design, Both Side Expandable Type. Bus Bar Design available in Aluminium Reference Standards IEEE 519-1992 harmonic standard. Harmonic Filtering : upto 15th Order Compensation : close loop Operational Voltage – 415 V, +10% - 15% VAC Rated Frequency – 50 Hz +/-5% Degree of Protection - IP 42 Rated short time withstand current – 25kA at 415V Internal Segregation: Form Seperation 3B Doors, Covers & Frames with very well gasketed with Neoprene / PU-Foam type gaskets Cubical is well ventilated with use of exhaust fan with louvers. Remote Monitoring: Ethernet based / Modbus RTU etc. Operator interface: Touch screen Display / Dedicated controller with operator activity log. Provision of Installation of Gas Flooding System. Hybrid PFC should have an Active Power Filter coupled with heavy duty APP type detuned capacitor banks. it should take care of “Power Factor ( Lead / Lag ) Harmonics, Load Balancing & Neutral issues automatically. it can be can be programmed for Reactive Compensation , Harmonic Mitigation , Neutral Compensation ( 4P/4W) Load Unbalance etc "
EMERGENCY PANEL (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER- ATS "1000A FP ATS , Solenoid type - 1 set ATS should be as per IEC60947-6-1, for AC33B utilisation category, 4 pole, 2/3 position, as per current rating mentioned in SLD, open transition, SOLENOID OPERATED ONLY, with common outgoing contacts/ terminals INTERNALLY SHORTED, manual operation should be possible in case of any Electrically operation issue. ATS must have switchover timing of less than 200msec and ELECTRICAL Life must be declared. ATS must be with dedicated controller having built in a) timer setting for both sources b) single phase sensing on MAINS side c) phase sequence sensing d) Remote DG START/ STOP Contact. Logic with separate timer/ contactor etc is not acceptable." SUB - INCOMER 1000Amp FP ACB 50 kA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/BACnet card and control MCB- etc as reqd)- 01 Sets Metering Inbuilt BMS Compatible Multi Function Meter with display parameter of Rms Voltage,.Current, Active Power, Reactive Power, Apparent Power,Power Factor, Phase Angle, Frequency, Active Energy, Reactive Energy, Apparent Energy, Demand As Well As Power Quality Parameters Like Thd Voltage %, Thd Current %, Total Demand Distortion (TDD %), K-Factor (Harmonic Factor) with control MCBs- 3 Nos and 1000/5 CTs - 3nos, and LED Cluster Indicating lamps Busbar : 1000A,TPN tinned Copper Basbar , suitable for 50 KA for 1 sec, electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves OUTGOINGS - 630 Amp TPN MCCB, 35 KA, (Ics= 100% Icu) with Microprocessor based LSIG release -02 Nos 200 Amp TPN MCCB, 25 KA (Ics= 100% Icu) with Thermal Magnetic releases & shunt Trip - 03 Nos On/Off/Trip indication , KWH Meter with required CTs & control MCB etc as per SLD
PLUMBING PANEL (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - 200 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :LM-2 Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre, KW, KWH, KVA, Frequency, PF, phase angle and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 3 Nos and 100/5 CTs - 3nos -01 Set SPD- 25KA type1&2 Busbar : 200 A,TPN tinned Copper Basbar , suitable for 25 KA , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves OUTGOING - 63/40 Amp FP MCB - 10 Nos
LIFT PANEL 01 (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - 400 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltag , Ampre, KW, KWH, KVA, Frequency, PF, phase angle and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs - 3 Nos and 250/5 CTs - 3nos - 01 Set BUSBAR : 400 A,FP tinned Copper Basbar , suitable for 25 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type2 OUTGOING - 80/63/40 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 12Nos 25 Amp DP MCB - 12 No
MLCP PANEL (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER 200 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltag , Ampre, KW, KWH, KVA, Frequency, PF, phase angle and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs - 3 Nos and 250/5 CTs - 3nos - 01 Set BUSBAR : 250 A,TPN tinned Copper Basbar , suitable for 25 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 63/40 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 03Nos (2 Nos Lifts & 01 Nos spares) 63/40 Amp FP MCB - 15 Nos 25 Amp DP MCB - 03 Nos (2 Nos Lifts & 01 Nos spares)
HVAC PANEL-01 (Non TTA as per Form 3B and IEC-61439 Standard. ) OUTDOOR TYPE - IP65 WITH DOUBLE DOOR & CANOPY + 300MM HIGH STAND INCOMER - 3200Amp FP ACB 50 kA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/BACnet card and control MCB- etc as reqd)- 01 Sets "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and 2500/5 CTs - 1nos -01 Set" BUSBAR : 3200 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 50KA type 2 OUTGOING - 1250Amp FP ACB 50 KA (Ics= 100% Icu= Icw) , with KWH Meter - 04 Nos 200 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 02Nos 100/80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 02Nos
HVAC PANEL-02 (Non TTA as per Form 3B and IEC-61439 Standard. ) OUTDOOR TYPE - IP65 WITH DOUBLE DOOR & CANOPY + 300MM HIGH STAND INCOMER - 3200Amp FP ACB 50 kA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/BACnet card and control MCB- etc as reqd)- 01 Sets "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and1600/5 CTs - 1nos -01 Set" BUSBAR : 3200 A,TPN tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 50KA type1&2 OUTGOING - 1250Amp FP ACB 50 KA (Ics= 100% Icu= Icw), with KWH Meter - 03 Nos 630 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 02 No 100/80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 04Nos
HVAC PANEL -3 TYPICAL (Non TTA as per Form 3B and IEC-61439 Standard. ) at 3Rd Service floor , to be connected from BBT INCOMER - 250A FP, Solenoid Type , ATS with Controller , Vitzotek Make - 1 no 250 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, per incomer and control MCB & required accessories. BUSBAR : 250 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 100/80 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release ,Shunt Trip - 01Nos 63/40A FP MCB - 23 32/25A DP MCB - 06
FLOOR PANEL -TYPE 1 (Non TTA as per Form 3B and IEC-61439 Standard. ) at basement INCOMER - "250A FP, Solenoid Type , ATS with Controller , Vitzotek Make - 1 no TS should be as per IEC60947-6-1, for AC33B utilisation category, 4 pole, 2/3 position, as per current rating mentioned in SLD, open transition, SOLENOID OPERATED ONLY, with common outgoing contacts/ terminals INTERNALLY SHORTED, manual operation should be possible in case of any Electrically operation issue. ATS must have switchover timing of less than 200msec and ELECTRICAL Life must be declared. ATS must be with dedicated controller having built in a) timer setting for both sources b) single phase sensing on MAINS side c) phase sequence sensing d) Remote DG START/ STOP Contact. Logic with separate timer/ contactor etc is not acceptable." 250 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCB & required accessories. BUSBAR : 250 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 100/80 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release, Shunt Trip - 03Nos 63/40A FP MCB - 12 32/25A DP MCB - 06 with 4 nos KWH Meters for 63/40A MCB
FLOOR PANEL - TYPE-2 (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - "160A FP, Solenoid Type , ATS with Controller , Vitzotek Make - 1 no TS should be as per IEC60947-6-1, for AC33B utilisation category, 4 pole, 2/3 position, as per current rating mentioned in SLD, open transition, SOLENOID OPERATED ONLY, with common outgoing contacts/ terminals INTERNALLY SHORTED, manual operation should be possible in case of any Electrically operation issue. ATS must have switchover timing of less than 200msec and ELECTRICAL Life must be declared. ATS must be with dedicated controller having built in a) timer setting for both sources b) single phase sensing on MAINS side c) phase sequence sensing d) Remote DG START/ STOP Contact. Logic with separate timer/ contactor etc is not acceptable." 160 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCB & required accessories. BUSBAR : 160 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 100/80 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release, Shunt Trip - 02Nos 63/40A FP MCB - 12 32/25A DP MCB - 03 with 4 nos KWH Meters for 63/40A MCB
FLOOR PANEL - TYPE-3 (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - "125A FP, Solenoid Type , ATS with Controller , Vitzotek Make - 1 no TS should be as per IEC60947-6-1, for AC33B utilisation category, 4 pole, 2/3 position, as per current rating mentioned in SLD, open transition, SOLENOID OPERATED ONLY, with common outgoing contacts/ terminals INTERNALLY SHORTED, manual operation should be possible in case of any Electrically operation issue. ATS must have switchover timing of less than 200msec and ELECTRICAL Life must be declared. ATS must be with dedicated controller having built in a) timer setting for both sources b) single phase sensing on MAINS side c) phase sequence sensing d) Remote DG START/ STOP Contact. Logic with separate timer/ contactor etc is not acceptable." 125 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCB & required accessories. BUSBAR : 125 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release, Shunt Trip - 01Nos 63/40A FP MCB - 12 32/25A DP MCB - 03 with 4 nos KWH Meters for 63/40A MCB
FLOOR PANEL - TYPE-3 (Non TTA as per Form 3B and IEC-61439 Standard. ) INCOMER - "100A FP, Solenoid Type , ATS with Controller , Vitzotek Make - 1 no TS should be as per IEC60947-6-1, for AC33B utilisation category, 4 pole, 2/3 position, as per current rating mentioned in SLD, open transition, SOLENOID OPERATED ONLY, with common outgoing contacts/ terminals INTERNALLY SHORTED, manual operation should be possible in case of any Electrically operation issue. ATS must have switchover timing of less than 200msec and ELECTRICAL Life must be declared. ATS must be with dedicated controller having built in a) timer setting for both sources b) single phase sensing on MAINS side c) phase sequence sensing d) Remote DG START/ STOP Contact. Logic with separate timer/ contactor etc is not acceptable." 100 Amp FP MCCB,25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 01 No Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCB & required accessories. BUSBAR : 100 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release, Shunt Trip - 01Nos 63/40A FP MCB - 10 32/25A DP MCB - 03 with 4 nos KWH Meters for 63/40A MCB
3x80KVA UPS OUTPUT PANEL INCOMER - 160 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 03 Nos "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and250/5 CTs - 1nos -01 Set per incomer " BUSBAR : 400 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 25KA type 2 OUTGOING - 100/80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 2Nos 63/40A FP MCB - 20 32/25A DP MCB - 06
3x160KVA UPS OUTPUT PANEL INCOMER - 320 Amp FP MCCB,36 KA, (Ics= 100% Icu) with Microprocessor based LSIG release - 03 Nos "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and250/5 CTs - 1nos -01 Set per incomer " BUSBAR : 700 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves SPD - 36KA type 2 OUTGOING - 100/80/63 Amp FP MCCB, 25 KA, (Ics= 100% Icu) with Thermal Magnetic Release MCCB - 4Nos 63/40A FP MCB - 22 32/25A DP MCB - 12
MRI PANEL-1 ( TYPICAL CT SCAN & CATHLAB) Incomer 400A TPn MCCB 25 KA with Shunt trip-1SET BUSBAR : 400 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and250/5 CTs - 1nos -01 Set per incomer " Outgoings 160A TP+100% NL MCCB, 25KA - 01set 63/40A FP MCB- 04set
MRI PANEL -2 ( TYPICAL CT SCAN & CATHLAB) ( UPS O/P) Incomer 250A TP+100% NL MCCB, 25KA with Shunt trip-2SET BUSBAR : 250 A,FP tinned Copper Basbar , suitable for 50 KA for 1 sec , electrolytic grade 99.95% purity Tinned Copper (Throughout the length) busbars with colour coded heat shrink sleeves "Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 3nos - 03 Set And MCBs 1Nos and250/5 CTs - 1nos -01 Set per incomer " Outgoings "165A FP Power CONTATOR with following ; 1) To ON/OFF from Panel 2) To ON /OFF from Console Room 3) To Emergency OFF from CT Room ." 63A FP MCCB, 16KA - 01set 32/25A DP MCB- 03SET
SITC of following RCBO/RCCB/MCB/MCCB with enclosures as per panel specifications
63/40A FP MCB with weather proof IP65 Box
25/40A FP MCB with weather proof IP65 Box
25A FP RCCB, 300mA with weather proof IP65 Box
40A FP RCCB, 300mA with weather proof IP65 Box
63A FP RCCB, 300mA with weather proof IP65 Box
63/40 Amp DP 10 kA,'C' curve MCB with powder coated metal enclosure
32/25 Amp DP 10 kA,'C' curve MCB with powder coated metal enclosure
63-100A FP MCCB ,25KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
125A FP MCCB ,25KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
200A FP MCCB ,35KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
250A FP MCCB ,35KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
400A FP MCCB ,35KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
630A FP MCCB ,35KA , with end termination box , copper tinned Speraders & extended bus bars , indicating lamps .VI-KWH Meter & required accsesories
FINAL DISTRIBUTION BOARDS Supplying and fixing of following types of factory fabricated prewired SPN and TPN double door sheet steel MCB distribution boards, moisture, dust and vermin proof having IP 43 degree of protection, 240/415 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, ( Per phase Isolation for TPN DBs )finished with powder coating including , earthing etc. as required : as per No. SW-SWR/MCBDB & No. SW-SWR/MCB
LIGHTING DB (LDB) "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB" Incommer 1 No.40A, FP MCB and 3 nos.40A/100mA DP RCCB each per phase with separate neutral & earth links per phase Outgoings 24 Nos.6A/10/16A SP MCB's
LIGHTING DB (LDB) "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB with following switchgears." Incommer 1 No.40A, FP MCB and 3 nos.40A/100mA DP RCCBs each per phase with separate neutral & earth links per phase. Outgoings 18 Nos.6A/10/16A SP MCB's
LIGHTING DB (LDB) / RAW POWER DB(RPDB) "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 6 ways / phase (18 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB with following switchgears." Incommer 1 No.40A, FP MCB and 3 nos.40A/100mA DP RCCBs each per phase with separate neutral & earth links per phase. Outgoings 12 Nos.6A/10/16A SP MCB's
RAW POWER DB(RPDB) "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB" Incommer 1 No.63A, FP MCB and 3 nos.63A/100mA DP RCCBs each per phase with separate neutral & earth links per phase Outgoings 24 Nos.10/16/20A SP MCB's
HVAC RAW POWER DB /RAW POWER DB(RPDB) "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB with following switchgears." Incommer 1 No.40A, FP MCB and 3 nos.40A/100mA DP RCCB each per phase with separate neutral & earth links per phase Outgoings 18 Nos.6A/10/16A SP MCB's
UPS DB "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB with following switchgears." Incommer 1 No.40A, FP MCB and 3 nos.40A DP MCBs each per phase with separate neutral & earth links per phase. Outgoings 18 Nos.6A/10/16A SP MCB's
UPS DB "Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 6 ways / phase (18 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB with following switchgears." Incommer 1 No.40A, FP MCB and 3 nos.40A DP MCBs each per phase with separate neutral & earth links per phase. Outgoings 9 Nos.6A/10/16A SP MCB's
STAIRCASE DB / ELDB Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted for following swithgears Incommer 25A , 30mA DP RCBO - 1 set Outgoings 8 Nos.6A/10A SP MCB's
LIFT DB ( TPN) "Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for following " Incommer 1 set 40/63A FP MCB Outgoings 1nos 63A FP RCCB , 300mA 2nos 25A., 100mA RCCB+MCB,
LIFT DB ( SPN) Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with following Incommer 1nos 32A DP MCB Outgoings 2nos 20A., 100mA RCBO Note: All MCCB Should have min Breaking capacity of min 25KA unless specified All MCCB will have rotary handle All MCCB should have 100% Ics=Icu All MCCB incuding 250Amps & onwrads will have microprocessor based releases All MCB will be rated for 10KA breaking capacity & C'curve characteristics for power & B'curve for lighting power
CABLES & SUB MAINS Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, complete erected with terminations compression glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL / CB-LT/CU
ALUMINUM CABLES 3.5 Core 25 sq. mm. A2XFY
3.5 Core 35 sq. mm. A2XFY
3.5 Core 50 sq. mm. A2XFY
3.5 Core 70 sq. mm. A2XFY
3.5 Core 95 sq. mm. A2XFY
3.5 Core 120 sq. mm. A2XFY
3.5 Core 150 sq. mm. A2XFY
3.5 Core 185 sq. mm. A2XFY
3.5 Core 240 sq. mm. A2XFY
3.5 Core 300 sq. mm. A2XFY
4 Core 25 sq. mm. A2XFY
4 Core 35 sq. mm. A2XFY
4 Core 50 sq. mm. A2XFY
4 Core 70 sq. mm. A2XFY
4 Core 95 sq. mm. A2XFY
4 Core 120 sq. mm. A2XFY
4 Core 150 sq. mm. A2XFY
4 Core 185 sq. mm. A2XFY
COPPER CABLES 1 Core 25 sq. mm. CU YY Cable
1 Core 35 sq. mm. CU YY Cable
1 Core 50 sq. mm. CU YY Cable
1 Core 70 sq. mm. CU YY Cable
1 Core 95 sq. mm. CU YY Cable
1 Core 120 sq. mm. CU YY Cable
1 Core 150 sq. mm. CU YY Cable
2 Core 4 sq. mm. 2XFY
2 Core 6 sq. mm. 2XFY
2 Core 10 sq. mm. 2XFY
3 Core 2.5 sq. mm. 2XFY
3 Core 4 sq. mm. 2XFY
3 Core 6 sq. mm. 2XFY
3 Core 10 sq. mm. 2XFY
3 Core 16 sq. mm. 2XFY
4 Core 4 sq. mm. 2XFY
4 Core 6 sq. mm. 2XFY
4 Core 10 sq. mm. 2XFY
4 Core 16 sq. mm. 2XFY
4 Core 25 sq. mm. 2XFY
4 Core 35 sq. mm. 2XFY
12 Core 1.5 sq. mm. CONTROL ARMOURED CABLES
16 Core 1.5 sq. mm. 2XFY CONTROL ARMOURED CABLES
4 Core 1.5 sq. mm. 2XFY CONTROL ARMOURED CABLES
BBT Supply, installation , testing & commissioning of 1000A, 1000V, 50Hz, 50kA for 1 Sec 3P+N-100%+PE Sandwich type Aluminium Busbar Trunking system as per IEC61439-6.Outer casing of system consists of four C-ribbed section bars, bordered and riveted with excellent mechanical, electrical and heat loss efficiency. The Sheetmetal is made of hot galvanized steel 1.5mm thick having degree of protection IP55. The busbar conductor have a rectangular corss-section with rounded corner, Aluminium alloy with Tin Plating. The Insulation between the bars is ensured by a double sheath made of polyester film Class F. The junction contact is ensured for each phase, insulated with red class F thermosetting plastic material. Enclosure is painted with RAL7035 resins with a high resistance to chemical agents. (130 x 130mm ) including External Al 2runs Earth bar,
Straight Length -Plug in Feeder
90degree Bends
Flange End
End Cover
Copper Braided flexible Jumper upto 300mm
Vertical Spring Hanger
Shaft Cantilever angle support with C Channel for Vertical spring or Rigid hangers
Vertical / Horizontal Supports
Horizontal / Vertical Offset
Supply, installation , testing & commissioning of Tap off Box - IP55, Plug in type suitable for MCCB with Plug in feeder , Spreader links , phase barrier etc all accessories as follows
250A, 4P MCCB, with Microprocessor based LSIG release , 25KA
200A, 4P MCCB, with Microprocessor based LSIG release , 25KA
160A, 4P MCCB, with Microprocessor based LSIG release, 25KA
125A, 4P MCCB, with Microprocessor based LSIG release , 25KA
100A, 4P MCCB, with Microprocessor based LSIG release , 25KA
LIGHITNG FIXTURES & FITTINGS Supplying and erecting of following of prewired light fittings/ light tracks, complete with all accessories such as side holders, ballast, wherever required, complete factory wired with copper conductor as required with lamp. Housing should be CRCA sheet 7 tank Processed & Powder coated. The fitting shall be fixed with chain ,screws etc. & recessed mounted in false ceiling
36W -40W LED SQUARE LIGHT ( 600 x 600mm ) "Supplying and erecting LED Panel Light(600mm X 600mm) having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
CLEAN ROOM LIGHT ( 600 x 600mm ) "40W LED square light fixture with bottom opening compatible for OT , lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
MRI ROOM LIGHT ( 600 x 600mm ) ( NON magnetic , MRI Compatible ) "40W LED square light fixture compatible for MRI , lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
18W LED DOWN LIGHTER "Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
7W LED DOWN LIGHTER "Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
11W LED DOWN LIGHTER "Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty."
20W LED TUBE LIGHT Supplying & erecting decorative pre-wired box type fitting/batten Each suitable for 4' LED tube light including LED 20W tube light Each with heat sink, integrated HF electronic driver complete
40W LED 1P67 TUBE LIGHT Supplying & erecting decorative pre-wired IP67 out door box type fitting/batten Each suitable for 4' LED tube light including LED 20W tube light Each with heat sink, integrated HF electronic driver complete
40W LED TUBE LIGHT Supplying & erecting decorative pre-wired out door box type fitting/batten Each suitable for 4' LED tube light including LED 40W tube light Each with heat sink, integrated HF electronic driver complete
10W LED BULKHEAD IN LIFT WELL "Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty."
LED DECORATIVE BOLLARDS Supplying and erecting 10W-15W LED Bollards , 300mm height IP67 having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with base plate & drivers within fixtures
DRIVE WAY LIGHT Supplying and erecting LED inground , drive way lights , IP67 having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with base plate & drivers within fixtures
STREET LIGHT "Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2."
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing cement concrete foundation including excavation for the poles (45 cm x 45 cm x 1.2 m) deep in 1:3:6 cement concrete (20 to 25 mm stone metal) and 45 cm x 45 cm x 45 cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 6 m pole)
Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Providing & erecting 8 m high (clear height) galvanised octagonal pole with single arms with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing & erecting 8 m high (clear height) galvanised octagonal pole with Double arms with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing & casting of M- 20 grade reinforced cement Each concrete (RCC) foundation suitable for 9m to 10m high octagonal /conical G.I. pole considering the safe soil bearing capacity at site as 10 T/sq m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template as per design in an approved manner. With Earth rod at depth of 2mtr & Gi 8SWG wire for Pole earthing .
Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
20W POST TOP LIGHT 20W decorative post top lights , housed in Al dicast , intigrited with drivers & all required accseories with decortaive mounting stand complete in all respect
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 900 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supply & Fixing of safety rope of required size with connector etc & complete in all resopect for above ceiling fans
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation
Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
Supply, installation , testing & commisoing ( including design & positioing ) of Lighing sensors , monitor human movement in their detection zone and automatically switch on lights in case human movement is detected with all necessary accessories , Junction boxes/ back boxes etc Presense & Motion Detector , dual sensor (PIR+Ultrasonic) capable ON /OFF lights as per human presence , with required accessories for mounting- Ref Model - Legrand - 48806
MS fabrication with powder coating of 450-700mm high mounting rod with base plate etc suitable for mounting Sensors for no false ciling areas
Prefered Makes : Legrand / Lutron / Hagger Notes: a)All fixtures shall be complete with lamps and control gear, 0.9Pf drivers etc b)Necessary down rods, hanging chains etc shall be part of the fixtures. c)Samples of all the fixtures shall be submitted to the architect before supply & approval is taken. d)Please check the quantity from drawings / architect / consultant before ordering. e)Color rendering index of the lamps to be confirmed from architect / consultant before ordering.
POINT WIRING, POWER OULETS & CIRCUITS Supply, installation , connection , testing & commisioing of following outlest points as per specification Primary Point
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW - Upto 6 meters
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW - upto 15 meters
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ HW - upto 25 meters
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW Upto 6 meters
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW - - upto 12 meters
Secondary point wiring for additional light/ bell point, concealed/Surface type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW - Upto 6 meters
Secondary point wiring for additional light/ bell point, concealed/Surface type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW - Upto 15 meters
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW
Supply & Installation of Power outlets with modular plate type switch / sockets , face plates , blank plates, Back boxes etc complete with all required accessories, the contacts should be sliver plated
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type Two way switch 6A / 10A (2 Module), duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete
25A Socket near AC/geyser indoor unit & 25A switch with indicator nearest SB. For indoor Acs/ Geyser.
32A, 2P+E, IEC309 Socket with Plug top & DP MCB, PVC moulded & housed in metal board , IP 43
63A, 2P+E , IEC309 Socket with Plug top & FP MCB , PVC moulded & housed in metal board, , IP 43
32A, 4P+E , IEC309 Socket with Plug top & FP MCB , PVC moulded & housed in metal board, , IP 43
32A, FP MCB with weather proof encloser, IP 65
6/16 A Switch socket outlet with IP65 enclosure
Supplying & erecting circuits mains as follows "Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW"
Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying & erecting mains with 4x4 sq.mm.and earth wire 2.5 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no.
Supplying & erecting mains with 4x6 sq.mm.and earth wire 4 sq.mm FRLS PVC copper wire in rigid PVC conduit min.20mm dia, as per specification No: WG-MA/PC, para no.
CABLE TRAYS & RACEWAY CONDUITS & TRUNKING
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX .
Supplying and erecting PVC slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX.
Supplying & erecting GI flexible Conduit 25 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete
Supplying & erecting GI flexible Conduit 40 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete
Supplying & erecting GI flexible Conduit 50 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete
Supply and laying raceways/conduits on floor/wall. The raceways/conduits shall be fixed to the floor/Wall with clamps for finished levels as per site conditions or through partitions with all accessories, bends, pull wire etc. but excluding the mounted junction boxes, bends, pull wire etc. but excluding the floor mounted junction boxes which shall be paid separately. The metal/PVC conduits/raceways shall be earth at suitable intervals the distance between data conduits and power conduits shall be maintained at least 6" apart.
100mm x 38mm, 1.6mm thk GI raceway
100mm x 50mm, 1.6mm thk GI Powder coated trunking for DB dressing
200mm x 100mm, 1.6mm thk GI trunking
300mm x 100mm, 1.6mm thk GI trunking
Supply and laying raceways/conduits on Ceiling . The raceways/conduits shall be fixed/Suspended to the Cieling with Threder Rods & Clamps as per site conditions with all accessories, bends, pull wire etc. but excluding the mounted junction boxes, bends, pull wire etc. but excluding the floor mounted junction boxes which shall be paid separately. The metal/PVC conduits/raceways shall be earth at suitable intervals the distance between data conduits and power conduits shall be maintained at least 6" apart.
200mm x 100mm, 1.6mm thk GI trunking
300mm x 100mm, 1.6mm thk GI trunking
Supply and installing of 2mm thick GI floor/Ceiling junction boxes for the raceway/conduits mentioned above of following sizes with cover with four nos. SS screws with proper cutouts on the sides for conduit entry and screwed top cover with rubber gasket and suitable knockouts ,as required complete in all respects.
75mmx75mmx45mm deep 2mm thk'
100mmx100mmx45mm deep 2mm thk'
150mmx150mmx45mm deep 2mm thk'
250mmx250mmx45mm deep 2mm thk'
350mmx350mmx45mm deep 2mm thk'
LADDER TYPE CABLE TRAYS
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 700 mm width & 100 mm height comprising all required standard accessories.
PERFORRATED CABLE TRAYS
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 50 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (2 mm thick) GI sheet of 300 mm width & 50 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG (2 mm thick) GI sheet of 450 mm width & 50 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware.
Supplying, design & fabrication of Iron work consisting of Various sections of MS and including Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
O. IT NETWORKING TELEPHONE ,TV WIRING
Supplying and installing enhanced cat-6 LSZH cable with 4-connector channel Performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO & with face plate
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supply & erection of junction box for 100 pair Telephone Tag Block Crone type with lock & key arrangement duly powder coated concealed in wall with 100 pair korne module, etc complete.
Supply & erection of junction box for 50 pair Telephone Tag Block Crone type with lock & key arrangement duly powder coated concealed in wall with 50 pair korne module, etc complete.
Supply & erection of junction box for 20 pair Telephone Tag Block Crone type with lock & key arrangement duly powder coated concealed in wall with 20 pair korne module, etc complete.
Supplying & erecting 50 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 6 as per specification No. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting 6 way splitter with surge superator
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 32 U floor mount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 μm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
Supplying and plugging 3 m fibre patch cord LC-LC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
Supplying and installing 6 port single mode fibre adapter with plate complete
Supplying and fixing multimode pigtails with SC/SC type splicing for (OM4) complete.
Supply, Installation, Testing & Commissioning of 19-inch 12 Port LIU (Fully Loaded), rack mount patch panel, 1U, loaded with 3 LC MM Duplex Adaptors & 6 LC-style Pigtails with Splice Tray, inclusive of all mechanical accessories, as per technical specification etc. as required.
P. ELEVATOR
Supply Installation Testing & Commissioning of Electric Traction Passenger Lift (Doctor, Guest & VIP Elevator) with Rated capacity :- 20 Passenger / 1360 Kg, Floors :- B+G+8 floor (10 Stops/10 Landings), Travel Distance :- 39 mtrs, Location of Lift Machine:-MRL, Rated speed :- 1.5 mps Car/Landing door clear opening of 1200 mm wide x 2000 mm high, Clear Car size of 1600 mm wide x 2400 mm deep x 2250mm high, Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, Pit depth 1600 mm & Overhead 4800 mm. Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. Full Collective control system, additional 2MP Camera along with necessary accessories
Supply Installation Testing & Commissioning of Electric Traction Passenger Lift / Strecher Elevator with Rated capacity :- 20 Passenger / 1360 Kg, Floors :- B+G+8 floor (10 Stops/10 Landings), Travel Distance :- 39 mtrs, Location of Lift Machine:-MRL, Rated speed :- 1.5 mps Car/Landing door clear opening of 1200 mm wide x 2000 mm high, Clear Car size of 1600 mm wide x 2400 mm deep x 2250mm high, Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, Pit depth 1600 mm & Overhead 4800 mm. Quadruplex Lift control system for four nos.microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. Full Collective control system, additional 2MP Camera along with necessary accessories
Supply Installation Testing & Commissioning of Electric Traction Service Elevator with Rated capacity :- 20 Passenger / 1360 Kg, Floors :- B+G+8 floor (10 Stops/10 Landings), Travel Distance :- 39 mtrs, Location of Lift Machine:-MRL, Rated speed :- 1.5 mps Car/Landing door clear opening of 1200 mm wide x 2000 mm high, Clear Car size of 1600 mm wide x 2400 mm deep x 2250mm high, Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, Pit depth 1600 mm & Overhead 4800 mm. Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. Full Collective control system, additional 2MP Camera along with necessary accessories
Supply Installation Testing & Commissioning of Electric Traction Freight Elevator with Rated capacity :- 20 Passenger / 1360 Kg, Floors :- G+1 floor (2 Stops/2 Landings), Travel Distance :- 6 mtrs, Location of Lift Machine:-MRL, Rated speed :- 1.0 mps Car/Landing door clear opening of 1200 mm wide x 2000 mm high, Clear Car size of 1600 mm wide x 2400 mm deep x 2250mm high, Lift shaft available having clear size of 2350 mm wide x 3000 mm deep, Pit depth 1600 mm & Overhead 4800 mm. Full Collective control system, additional 2MP Camera along with necessary accessories
Supply Installation Testing & Commissioning of Electric Traction Passenger Lift (MLCP) with Rated capacity :- 15 Passenger / 1020 Kg, Floors :- G+3 floor (4 Stops/ 4 Landings), Travel Distance :- 9 mtrs, Location of Lift Machine:-MRL, Rated speed :- 1.0 mps Car/Landing door clear opening of 900 mm wide x 2000 mm high, Clear Car size of 1100 mm wide x 2100 mm deep x 2250mm high, Lift shaft available having clear size of 1950 mm wide x 2500 mm deep, Pit depth 1600 mm & Overhead 4800 mm. Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. Full Collective control system, additional 2MP Camera along with necessary accessories
Q. SUBSTAION WORK
MSEDCL Supply side Breaker for Cable Termination ( RMU-1) 11KV HT 4 WAY RMU Supplying, erecting, testing & commissioning SF6 Insulated 11kV, 630A, 21kA/3sec, 4 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 2 nos. feeder with 2 VCB compliant to IEC 62271 -100, 200 and 102.
11KV METERING KIOSK "Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation."
HT VCB PANLES "Supplying, installing, testing and commissioning 11 kV 630A, vacuum circuit breaker with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS /VCB - 5 SET , 1 INCOMER & 4 OUTGOINGS , expandable type with required accesories "
HT CABLE Supplying , erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying , erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 150 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 240 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
HT CABLE TERMINATION & JOINTNS ( Heat shrinkable type) Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
TRANSFORMER 1600KVA ONAN , INDOOR TYPE TRANSFORMER Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 1600 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper), with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load as per IS:1180(part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. Ratio: 11/0.433 KV , 50 Hz, 3 phase, DYN-11 H.V. Side: Cable end box L.V. Side: BBT
Supply, installation , testing & commissioning of 3200A, 1000V, 50Hz, MIN 65kA for 1 Sec 3P+N-100%+PE Sandwich type Aluminium Busbar Trunking system as per IEC61439-6.Outer casing of system consists of four C-ribbed section bars, bordered and riveted with excellent mechanical, electrical and heat loss efficiency. The sheetmetal is made of hot galvenized steel 1.5mm thick having degree of protection IP55. The busbar conductor have a rectangular corss-section with rounded corner, Aluminium alloy with Tin Plating. The Insulation between the bars is ensured by a douoble sheath made of polyester film Class F. The junction contact is ensured for each phase, insulated with red class F thermosetting plastic material. Enclosure is painted with RAL7035 resins with a high resistance to chemical agents. . (130 x 380mm )
Straight Length -Plug in Feeder
90degree Bends
Flange End
End Cover
Copper Braided flexible Jumper upto 300mm (with Lugs)
Vertical Spring Hanger
Shaft Cantilever angle support with C Channel for Vertical spring or Rigid hangers
Vertical / Horizontal Supports
Horizontal / Vertical Offset
Supply, installation , testing & commissioning of IP68 3200A, 1000V, 50Hz, MIN 65kA for 1 Sec 3P+N-100%+PE Sandwich type Aluminium Busbar Trunking system as per IEC61439-6.Outer casing of system consists of four C-ribbed section bars, bordered and riveted with excellent mechanical, electrical and heat loss efficiency. The sheetmetal is made of hot galvenized steel 1.5mm thick having degree of protection IP68. The busbar conductor have a rectangular corss-section with rounded corner, Aluminium alloy with Tin Plating. The Insulation between the bars is ensured by a douoble sheath made of polyester film Class F. The junction contact is ensured for each phase, insulated with red class F thermosetting plastic material. Enclosure is painted with RAL7035 resins with a high resistance to chemical agents. . (130 x 380mm )
Straight Length -Plug in Feeder
90degree Bends
Flange End
End Cover
Copper Braided flexible Jumper upto 300mm (with Lugs)
Vertical Spring Hanger
Shaft Cantilever angle support with C Channel for Vertical spring or Rigid hangers
Vertical / Horizontal Supports
Horizontal / Vertical Offset
TRANSFORMER ISOLATOR AS FOLLOWS 3200Amp 4P ACB 65 KA (Ics= 100% Icu= Icw) with standing Capacity of EDO type and with Microprocessor based releases (with Over current / Earth fault/ Short circuit / shunt trip coil with under voltage releases ), BMS compatible hardware and software like RS 485/potential free contacts /Modbus/Bacnet card and control MCB- etc as reqd)…1set Metering :- Inbuilt BMS Compatible Multi Function Meter with display parameter of Voltage, Ampre,KW,KWH,KVA,Frequency,PF, phase angle, Harmonics and LED Cluster Indicating lamps, ELR WITH CBCT per incomer and control MCBs- 4Nos and 3200/5 CTs - 4nos - 04 Set And MCBs 2Nos and 2000/5 CTs - 2nos -02 Set SPD -65KA type 1 & 2 - 2 NOS With Extended Bus bar for connceting fxied capacitor 50KVAr Fixed capacitor with SFU - 2 set
R. DG SET
3X1050KVA DG SET SYNCHRONISTION PANEL- (Non TTA as per Form 3B and IEC-61439 Standard. ) "Supply , installation , testing & commisioing of power & energy managemnet system comprises of OUT DOOR DG Synnchronisation , AMF logic / auto starting , load sharing & shedding system with necessary hardwares etc to complete the instalation as per specification & IS standards . with required size and quantity of ACB with C0MMON OUTGOING BUSBAR and other STD accessories as per system Requirement and in line with specifications shared in separate sheet. Panel should be mounted on MS STAND FOR BOTTOM ENTRY OF ALL CABLES WITH BASEFRAME OF 75 x 75mm. The scope shall also includs to provide technical training to client's technical team & also to operate entire system on actual loading condition for 3 months time after completion of projects "
1050KVA DG SET "Supplying, erecting, testing and commissioning of diesel generating set with alternator of 1050 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 170 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m / CPCB-IV Compliance , provided with first filling of oil, diesel not less than 990 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG"
Exhaust Piping including with following - Supply and providing exhaust piping complete with exhaust pipe, fiber glass insulation with aluminium cladding, pipe accessories like flanges, bends, elbows, rain protection hoods, etc. The exhaust piping shall be fixed from floor with MS angle supports, using necessary clamps, anchor bolts, vibration isolation pads, etc., as shown in the drawing. Pipe size shall be suitable for 625KVA Diesel generator sets.
Exhaust pipe with Aluminium cladding - 8" this includes Mineral wool / glass wool lagging for exhaust pipe system including aluminium cladding suitable for the above item.
Exhaust pipe with Aluminium cladding - 12" this includes Mineral wool / glass wool lagging for exhaust pipe system including aluminium cladding suitable for the above item.
Exhaust pipe with Aluminium cladding-14" this includes Mineral wool / glass wool lagging for exhaust pipe system including aluminium cladding suitable for the above item.
Exhaust pipe with Aluminium cladding-18" this includes Mineral wool / glass wool lagging for exhaust pipe system including aluminium cladding suitable for the above item.
Supply & installation of 50 mm thk. Insulation with rockwool density-64 kg/m3 and 24 guage aluminium cladding for above exhaust pipe.
Civil/RCC work for Exhaust support, duly certified by RCC consultant , cost to be included for certifications
Supply and erection of 'Exhaust pipe supporting system with ISMC, ISAs 'complete including red oxide and black enamel painting and RCC foundation
Foundation and necessary arrangement for chimeny for above work
S. FIRE SAFETY SYSTEM ADDERSSABLE FIRE ALARM SYSTEM
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. ( All FAS panels shoudl be networkable to intigrate with BMS system )
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP ( All FAS panels shoudl be networkable to intigrate with BMS system )
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF- AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of digital linear heat detection cable addressable through monitor module with temperature ratings such as 60°- 70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC.
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supply, installation and testing & commissioning of Addressable Fire Fighter's Telephone Control Panel with master telephone handset.
Supply, installation and testing & commissioning of IP67 Flasher Light
Supplying and erecting GSM Based Auto Dialer Unit
PUBLIC ADDRESS SYSTEM.
CONTROLLER "Supply, installation, testing & commissioning of Master EN-54 certified 10 ZONE IP based digital voice alarm network controller with built in SIP Intercom, redundant IP connection, redundant power supply unit built with following features: Voice alarm controller should be able to connect directly over Ethernet & LCD display for displaying troubles, events. It should have functions like audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. Network controller shall also have following functions. - Able to handle 16 simultaneous audio channels in the controller and upto 96 loudspeakers lines - Built in DSP with 10 band parametric EQ for each output - In-built digital message storage with minimum 16GB capacity - in Built 16 relay contact input and 4 relay contact output -Automatic fault diagnostic & reporting at central location from call station till amplifiers, loudspeaker circuits. -Matrix controller shall have analog audio input lines for music Sources, Fire Alarm Signals - External systems, like PIDS or Scada, can get full control of the PA by opening a TCP socket to the mainframe. More than one client is allowed. "
Amplifier "Supply, installation, testing & commissioning of below watts of Class-D digital amplfiiers. Unit shall have following features & shall comply to technical specifications. 1. Protected against overload, short circuits and over-heating 2. Built-in fan with temperature-controlled rotation speed control, with airflow from front to back of device." 2*500 Watts or equivalent of wattage to be considered OR EQUIVALENT wattage
Power supply Manager "Supply, installation, testing & commissioning of emergency power supply manager allows the permanent emergency power supply in accordance with EN 54-4 certified , in the event of a power failure. The 19” unit (2U) is equipped with 6 fused outputs that can be used with up to 30 A load. The smart battery condition monitoring ensures an uninterrupted 24 V DC power supply and the recharging of the battery immediately after the restoration of the mains supply. Due to the “hot swap” technology the exchange of the batteries can be done without service interruption."
LOUDSPEAKERS
Supply & Installation of 95MM DIA 6W ABS body with Metal grille Ceiling Speaker with required mouting brackets as per site requirements featured with max SPL @1M/6W 89dB . Frequency response of 125Hz-16KHz with a dispersion angle of 170 deg. The speaker should have tappings at 6W/3W/1.5W with required back box as per site requirement and architect approval, as per the technical specifications etc. as required.
Supply & Installation of 6W Wall Speaker with required mouting brackets as per site requirements max SPL @1M/1W 87dB . Frequency response of 200Hz-15KHz . The speaker should have tappings at 6W/3W/1.5W, as per the technical specifications etc. as required.
Supply, Installation, Testing and Commissioning of 40W Wall Mount speaker with required mouting brackets as per site requirements max SPL @1M/40W 115dB . Frequency response of 200Hz-20KHz . The speaker should have tappings at 40W/20W/10w,as per the Tender specification and as directed by engineer in charge
Cables & Conduits Supply, laying testing & commissioning of 2-Core, 1.5Sq. mm Copper Conductor, PVC insulated, braided & Armored, , FRLS Cable.
RODENT CONTROL SYSTEM (Café , HUB ROOM , SERVER ROOM, UPS & BATTERY ROOM) Supply Installation, Testing and commissioning of Rodent Controller Panel The Master Console shall be able to connected to 24 Satellites in loops , the controller should have automatic variable wave speed , wave density , frequency band etc , the system should be BMS intigrited with modbus protocol & should be modulated from BMS system , It should have human safety as per IRPA guidelines. Vendor is also required to provide output verifications of waves during handing over stage / commissioning stage. (Make - Maser)
Supply Installation, Testing and commissioning of Transducer Satellite Stations. (500 Sq.ft.) (Make - Maser)
Supply installation of Floor/ ceiling Mounted Powder Coated Junction Box complete with Glands and fitting accessories
Supply, Installation & Commissioning of 14/40 SWG Specially Coated Single Pair armoured cable , with Saddle & Spacers, and all related mounting accessories.
ANALOGUE WATER LEAK DETECTION SYSTEM FOR SERVER ROOM/UPS ROOM Design , Supply , Installation , Testing & Commsisioning Of Microprocessor based LCD Display control Panel - 4 Zone with required module , should have Volt free contact for BMS intigration for Fault / Status / Alaram
The water leak sense cables in following lengths
5 Mtrs. Length
10 Mtrs. Length
15 Mtrs. Length
25 Mtrs. Length
Hold down clips with adhesive to fix sensing cable length to be used at corner or every 1 mtr.- 100/pck with adhesive
Hooter for WLD , make : Ravel / Agni
2 C x 1.5 Sq.mm Copper Armoured Cable,PVC insulated,PVC Sheathed layed with Single compression Cable Glands,ABS Junction Boxes( wherever required ), terminals,Ferruling complete. TOTAL FLOODING SYSTEM - FK-5112 SERVER ROOM "DESIGN , CALCULATIONS , SUPPLY , INSTALLATION , TESTING & COMMSISIONING FFK-5112 Considered protection is for Class A & C fire, Design Concentration based on NFPA 2001 latest edition & Cylinder should be PESO approved any missing item or required ietm to be considered in given below quote, complete in all respect"
80 Ltrs. Cylinder with Valve & Warning Sign Boards, OEM Factory filled with FK-5112 CLEAN AGENT Suppression Liquid , pressurised to 25/42 bar ., Gas rates to be quoted seperately , Cylinder to be PESO approved , The cylinder should have Potential free contact for Auto/Manual Status & Low Pressure Switch for BMS intigrations MAKE : SIEMENS/3M/CEASEFIRE/CRYPTZO
FK-5112 Fire Protection Fluid, OEM Factory Fill in Kgs stored in above cylinder @ 25 / 42 bar. MAKE : SIEMENS/3M/CEASEFIRE/CRYPTZOD
Master Cylinder Accessories Comprising Below Items: * Pr. Guage + Low Pr. Supervisory Switch * Electromagnetic Actuator * Pneumatic Actuator * Flexible Discharge Hose * Flexible Actuation Hose * Manual Pneumatic Actuator * Union 7/16 JIC 1/8
Nozzles
Seamless MS painted Piping, fittings & supports, etc. inclusive of all necessary fixing accessories, joints, bends, couplers as requires. ( Area range - 200-300Sqft)
Supply installation Testing & commissioning of Single zone Gas Release Panel facility to connect Manual Abort/Release switches. The Panel shall provide Potential free contacts for First knock, second knock, Trouble / Fault Status. The Panel shall be Complete with Red Colour Housing, Power supply unit, Battery charger & batteries.
Photoelectric detector Smoke Detector
Gas Relese Module
Dual Tone Electronic Sounder with Flasher
Manual Release / Abort stations along with back box & necessary glass on top
2 core x 1.5 Sqmm FRLS PVC,multistrand Copper Cu Ar cable confirming to IS 694 standards and specifications with required supports , accessories , sadeling etc as per Stanadrd practice for installation of cables.
15KG ceiling suspended Clean agent cylinders with mounting barckets , presure guage etc complete in all respect
5KG ceiling suspended Clean agent cylinders with mounting barckets , presure guage etc complete in all respect
ADDRESSABLE INTELLIGENT EMERGENCY LIGHTING SYSTEM Makes : Huchiki/Eton Supplying & Fixing emergency lighting control panel with two lighting lines with minimum of 127 devices on each line. The system shall work on extra low voltage and shall be addressable complete as required.
Supplying and Fixing ELS Panel transformer 230V with an output of 35V ac and capable of providing low voltage supply to the lighting lines complete as required.
Supplying and Fixing of Key pad with an LCD to control and read the Main ELS Control Panel complete as required.
Supplying and Fixing of Addressable Open Area LED Down Lighting compling with BS5266 with integral battery capacity of 2 hrs. and bicoloured LED status indicator complete as required, complet with mounting base .
Exit Sign Left/Right/Up/Down with frame, mounting base & with integral battery capacity of 2 hrs
Supply & Installation of 2 Core x 1.5 Sq.mm Flex FRLS cable with Gi conduites for looping the devices & providing power Supply to sounder cum strobes
T ACCESS CONTROL SYSTEMS
Supply, installation, testing & commissioning of of HID make only Readers (I Class R-10)
Supply, installation, testing & commissioning of Biometeric Thumb print readers complete
Supply, installation, testing & commissioning of HID make Door controllers of the following configuration. The controllers shall have open protocol and shall be integrated with Open Source Software. HID Aero X1100
Supply, installation, testing & commissioning of Licensed Enterprise Software for ACS and Time Management/Attendance complete as required, 500-1000 usres
Supply and installation of surface mounted monitored Magnetic door locks capacity of holding pressure of 650 lbs. with door feedback
Supply and installation of surface mounted monitored Magnetic door locks capacity of holding pressure of 1200 lbs. with door feedback
Supply and installation of with Hooter complete set for Fire Exit Doors. (note: the Panic Bar shall be provided by the Door Supplier)
Supply, installation, testing & commissioning of of Magnetic contacts for fire exit doors
Supply, installation, testing & commissioning of of Touch free IR Exit Switch
Supply, installation, testing & commissioning of Extra Exit Switch at Reception for Visitor Entry
Supply, installation, testing & commissioning of of Emergency Release Switch Switch (Green MCP)
Supply, installation, testing & commissioning of following armoured cable on cable trays/ wall
8core 1.0 sq.mm Shielded, PVC Sheathed Copper armoured Cable
4 core 1.0 sq.mm Copper PVC Sheathed Cable
2 core 1.0 sq.mm Copper PVC Sheathed Cable
U FIRE FIGHTING SYSTEM
HYDRANT PUMPS & ACCESSORIES Supplying, installation, testing and commissioning of main fire pump(MFP /EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following :
(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP 2280 LPM @ 85 M head
"Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :" (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP 180 LPM @ 85 M Head
Terrace booster pumps Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP 2280 LPM @ 85 M head
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting G.I. pipe ‘C’ class ERW with necessary fittings complete as per specification no. FF-PP
80 mm dia (For Booster & Jockey Pump)
150 mm dia (For main pump)
200 mm dia (For main pump)
250 mm dia (For suction manifold)
Supplying and erecting dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
80 mm dia ( Jockey Pump)
100 mm dia (For Booster pump)
150 mm dia (For main pump)
200 mm dia (For tank Suction & Interconnection of delivery header)
Supplying and erecting cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
50mm dia(for pump)
80 mm dia (For Jockey Pump)
100 mm dia (For Booster pump & test line)
150 mm dia (For main pump)
200 mm dia (For main pump & Sprinkler pump delivery) (Fire pipe interconnection)
Supplying and erecting gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
20mm dia (for pump)
25mm dia (for pump)
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
100 mm dia (For Booster Pump)
250 mm dia (For main pump)
Supply, Installing, testing and commissioning of CI body wheel operated Gate valves with required flanges, nuts, bolts and gaskets etc. all complete. 250 mm dia (For suction manifold)
CONTROL PANELS Supplying, installation, testing & commissioning of following Indoor type, compartmentalized and sectionalized cubicle panel of suitable size, fabricated from cold rolled CRCA sheet steel of 2 mm thick , having vibration free structure chemically treated surface with seven tank process before painting, epoxy powder coated after two coats of anti-rust primer, making earth connections by providing copper earth strip of size 25 x 5 mm thick all along horizontal run of the panel suitable for operation on 3 phase 415 V 50 HZ AC supply i/c providing and fixing the following switchgear to be mounted thereon complete with gaskets, interconnections and earthing with suitable size PVC insulated FRLS copper wire .The panel shall be dust free, vermin proof and totally enclosed with Degree of protection of IP 54 as per IS 2147, with suitable cable/busbar alleys and shall be mounted on MS channels of size not less than 100 x 75 mm iron frame on floor etc as per specifications complete as required .Gland plates hould minimum 3 mm thick and top and bottom. Fire panel colour to be paint with P O Red colour. The boards shall be treated with all anticorrosive process before painting as per standards with 2 coats of red oxide primer & final approved shade of powder coating. 2 nos. earthing terminals shall be provided for 3 phase distribution boards. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall be provided in case of large boards. Boards shall be fabricated in easily transportable sections & length, height, depth etc to match with site conditions. An approval shall be taken for each panel before final manufacture. Galvanised hardwares with zinc passivation shall be used in fabrication of boards. Follow the detailed specifications at the time of fabrication.
Note: Panel Should have separate BMS / ELV/Fire trip compartment All CTs should have 5VA Burden, CL : 1 accuracy All Meters will be BMS Comaptible, Acc Cl 1.0 All MCCB will have rotary handle All MCCB should have Ics=Icu 100% All MCB will be rated for 10KA breaking capacity & C'curve characteristics MCB in capacitor panel should be with D'curve characteristics
SPARE FEEDERS 1 nos. 320Amp, 3 Pole MCCB with Microprocessor based LSI release (with RS485 interface, MODBUS-RTU protocol) for overload and short circuit protections having Earth fault relay with rated CTs, Shunt coil, 415V, 50 Hz, A.C supply and having Ics=Icu= 36 KA. The MCCB shall be complete as per technical specifications and single line diagram. 2 nos. 63 amps, 3 Pole MCCB with thermal magnetic based release for overload and short circuit protections , 415V, 50 Hz, A.C supply and having Ics=Icu= 26 KA. The MCCB shall be complete as per technical specifications and single line diagram. Fire Panel will have BMS / IOT intigartion arrangements for On/Off/Trip, Auto/ Manual mode status as per Fire norms & all ELV terminals to be kept ready for BMS / IOT intigration in separate compartment Notes : All outgoing feeders shall have suitable range of followings:- a. 415 / 110 V suitable rating control transformer shall be provided for aux. control supply if necessary. b. Wiring with space heater, thermostat and control MCB’s shall be provided in all vertical sections of Main LT panel. c. All incoming as well as outgoing feeders shall have pad locking facility. d. Suitable danger board shall be provided. e. All bus bar section / backside panels shall have pad locking facility and hinged type door. f. CTs to be considered for All the Load Managers g. SPDS to be considered as per SLD.
FIRE FIGHTING PUMPS REMOTE CONTROL PANEL Panel Fabricated Out Of 14/16 SWG CRCA Sheet Compartmental Construction Suitable For Wall Mounting With Provision For Bottom Cable Entry. box duly powder coated after carrying 7 tank process. 9 Nos Starter Fire Pump Remote Systems LED Indicator Pilot LED Light On Start Push Button Stop Push Button NO Elements NC Elements 2.5mm Conectors
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm
Push Button
Supply, Installing, Testing and Commissioning of Remote Push Button Station for Booster Pumps
Supply, Installing, Testing and Commissioning of Remote Push Button Station for Main Pumps
Pressor Sensor Supply, Installing, Testing and Commissioning of Pressure senor for Pumps with BMS compatible so that it can be integrated with IOT System.
Tampered Switch Supply, Installing, Testing and Commissioning of Tampered Switch for integration of Butterfly valve with BMS syatem so that if any valve get closed by anyone will get notify in BMS System.
FIRE HYDRANT SYSTEM Supplying and erecting G.I. pipe ‘C’ class ERW with necessary fittings complete as per specification no. FF-PP For wet riser system - GI "C" heavy class pipe
25 mm dia (To connect First aid hose reel to fire riser)
80 mm dia (Landing valve & External hydrants)
100 mm dia (Breaching inlet to UG fire tank)
150 mm dia (Fire duct riser)
200 mm dia (In Fire ring above ground)
Supplying and erecting cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV 150 mm dia (In Fire duct riser and In Fire ring at ground)
Supply, Installing, jointing, testing in trenches in ground with wrapping & coating of the following sizes of GI "C" class pipe (heavy class) conforming to IS 1239 & all the necessary fittings like flanges, bends, tees, elbows, reducers, unions supporting with G.I clamps hangers etc including all the necessary excavation in ground, cuttings holes and chases in brick or rcc wall/slabs and making good the same to the approval of architect/ consultant & as instructed by site incharge all complete. (Underground fire ring Piping).
100 mm dia (Breaching inlet to UG fire tank & External hydrant)
150 mm dia (Fire hydrant pipe)
200 mm dia (Fire hydrant & Sprinkler pipe)
Providing & fixing ball valve (brass) of approved quality, high & low pressure with plastic floats complete. 25 mm dia (For firstaid hosereel & for ARV of Hydrant & Sprinkle riser)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (External Hydrant)
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (Internal Hydrant)
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and fixing M.S. Hose cabinet stand mounted type fabricated out of M.S. sheet of 16 swg. with glass fronted (4mm thick glass with rubber beeding) door and size of the cabinet shall be 750 x 650 x 250mm cabinet shall be powder coated with P.O. Red and marked on the front as " FIRE HOSE" (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer).
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Providing and fixing 2mm thick PVC lockable cabinet of size not less than 0.60mtr x 0.75mtr (height)x 0.25 mtr having central opening and 4mm thick glass doors (Twonos.)suitably marked on the outside with the letters "FIREHOSE" including necessary locking arrangement and shall be painted with two coats red colour. The cabinet shall be suitable to accommodate 2nos. 15 mtr long Hose pipe &2 No branch pipe nozzle. It shall be mounted on raised Brick plat form complete as required. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer). (In Lobby )
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC(For Hydrant & Sprinkler ring main)
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC (Breaching inlet to fill UG fire tank)
Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
AUTOMATIC SPRINKLER SYSTEM Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent type sprinkler of 15 NB, 68 deg.
Upright type sprinkler of 15 NB, 68 deg
Side Throw type sprinkler of 15 NB, 68 deg.
Adjustable ceiling roset plate
UL/FM Approved Providing and fixing of Sprinkler Flexible Breaded drop pipes made of Corruggated SS Tubing to with stand 16 Bar pressure with welded reducer on one end to directly accomadate sprinkler & female checknut on the other end to connect to the branch pipe with supports complete
Providing and fixing in position sprinkler guards to protect open sprinkler on all floors from mechanical damage.
Supplying and erecting G.I. pipe ‘C’ class ERW with necessary fittings complete as per specification no. FF-PP
200 mm dia (Sprinkler ring)
150 mm dia (Sprinkler branch + riser)
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying and erecting cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
150 mm dia
Supplying and erecting G.I. pipe ‘C’ class ERW with necessary fittings complete as per specification no. FF-PP 80 mm (Drain pipe)
Supply & installation of Drain valve 50mm dia with sight glass including all necessary hardware & accessories, etc. complete as required
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
150mm dia
100mm dia
80mm dia
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
FIRE EXTINGUISHER Supplying & erecting of Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878 Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying & erecting of IS marked 6 Kg Clean Agent (IS:15683) portable fire extinguisher, Design - Hose & Nozzle, Fire rating- 2A :55b, Fire rating (as per EN)- 8A:55B, Heigh (Approx) - 530mm, Diameter (approx.) - 150 mm, Average discharge time - 22 Sec, Average range of throw- 4m, Average % Discharge - 96%, Operating temperature - (-30 dec to +60 dec), Service Pressure - 10 bar, Max service pressure - 12 Bar, Test Pressure - 35 Bar, Expelling Agent - Nitrogen (UHP Grade), Empty weight - 2.9 kg, Full weight - 8.9kg, including discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill, wall suspension bracket (Location: -Panel, LMR, ELE & LV ROOM, )
Supplying & erecting of ISI marked ABC type Dry chemical powder type fire extinguisher of capacity 9 Kgs with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.(Lobby)
Supplying & erecting of ISI marked Dry chemical powder typr fire extinguisher of capacity 6 Kgs with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.( At car parking area at ground level)
Providing and fixing Galvanised mild steel Fire bucket with clean sand & stand (3 buckets for each stand) in accordance with IS 2546. Fire bucket shall have two coats of anti corrosive paint, two coats of red colour conforming to shade No. 536 or 538 of IS 5. The paint shall conform to IS 2932 on its outside & two coats of white paint on the inside. The word "FIRE" shall be clearly stencilled on it in accordance with IS 2546. Vendor to include in his quote all costs relating to mounting of the bucket at locations stated by the Fire NOC & the architect. Vendor to include in his quote all costs all accessories, consumables, fittings & rigging equipment's necessary for the satisfactory installation of the same. (IN PUMP ROOM, GROUND FLOOR - ELV ROOM)
AUTO FIRE EXTINGUISHERS
Supplying, fixing, testing and commissioning Ceiling Suspended Clean Agent Auto Fire extinguisher with pressure gauge , 5 KG - FOR HUB Room.
Supplying, fixing, testing and commissioning Celling Suspended Clean Agent Auto Fire extinguisher with pressure gauge , 15 KG - FOR SERVER Room.
Supplying & erecting of ADAcompliantmodularMultilingualandtactileEmergencyevacuationmapofeachfloorindicatingthecurrentpositionoftheviewersaying"YOUAREHERE"of15mmheightlettersinredwithwhitebacKilogramround,indicatingtheemergencyexits,locationsoffireextinguishersetc.Signsshallhaveasolidheaderwiththetext“EVACUATIONPLAN”incontrastinguppercaselettersnolessthan3/4"inheight.Thesizeoftheboardshallbe2ftx2ftandshallbeinstalledataheightof1200mmfromFFLandshallbeoriented to the position of the viewer as per the direction of the site engineer
Cabinet Fire Supression System for Elect panels
Supply, Installation, Testing and Commissioning of Panel proection system,Fire Extinguisher -MMO FIRESPOT 4 kg with Pressure Switch (FK5112) with Heat sensitive tube - 25 mtrs with necessary accessories like pressure gauge, Dummy End Cap, Threaded Nipple End and mounting Bracket.
Supply, Installation, Testing and Commissioning of Panel proection system,Fire Extinguisher -MMO FIRESPOT 2 kg with Pressure Switch (FK5112) with Heat sensitive tube - 15 mtrs with necessary accessories like pressure gauge, Dummy End Cap, Threaded Nipple End and mounting Bracket.
Harsh Constructions Pvt Ltd (BID ID -6577779)
Harsh Constructions Pvt Ltd (BID ID -6577779)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid