Executive Engineer, HPPWD. Electrical Division Una
Executive Engineer, HPPWD. Electrical Division Una
.
2022_PWD_64716_1
No. TA/2022-23/- 4628-48 dated 02.09.2022
Open Tender
Electrical Works
Item Rate
365 days
Una
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
₹30,800
27 Oct 2026
9 Sept 2022
17 Sept 2022
9 Sept 2022
17 Sept 2022
9 Sept 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modularswitch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) or its equivalent as approved by Engineer-in-Charge
Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make :-Anchor (Roma classic ),L&T (Entice), Legrand(Myrius) or its equivalent as approved by Engieer-in-Charge
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make :-Anchor (Roma classic ),L&T(Entice),Legrand (Myrius) or its equivalent as approved Engineer-in-Charge
Group B
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.Make:-Plaza,KEI, Finolex or its equivalent as approved by Er-In-Charge
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Plaza,KEI,Finolex or its equivalent as approved by Engineer-in-Charge
3 x 1.5 sq. mm
3 x 4 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredMake :-Anchor (Roma classic ),L&T(Entice), Legrand(Myrius) or its equivalent as approved by Engineer-in-Charge
5/6 amp Modular switch
5 pin 5/6 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as requiredMake :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) or its equivalent as approved by Er-In-Charge
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) or its equivalent as approved by Engineer-in-Charge
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required..Make :-Anchor (Roma classic ),L&T(Entice),Legrand (Myrius) or its equivalent as approved by Er-In-Charge
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand (Myrius) or its equivalent as approved by Engineer-in-Charge
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Diplast/BEC/Polyfit.or its equivalent as approved by Er-In-Charge
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as requiredMake :-Anchor (Roma classic ),L&T(Entice),Legrand (Myrius) or its equivalent as approved by Engineer-in-Charge
Providing and installation exhaust fan of 300 mm light duty (Domestic type) in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make : Usha,Bajaj, Crompton or its equivalent as approved by Engineer-in-Charge
Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required,
Providing, Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing fan box ,phenolic laminated sheet cover on the fan box and earthing etc. as required: Make:- Usha(TECHNIX PLUS)Bajaj, Crompton or its equivalent as approved by Er-In Charge
Ceiling Fan 1200 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) or its equivalent as approved by Er-In-Charge
Supplying and fixing LED Lamp 9 watts 6500 K E-27 ,900 Lumens 240 volts AC.supply 50 HZ in the existing batten holder,pendent holder,wall bracket & bulk head fitting etc, as required:Make TISVA ( Cat no AL916611X) ),wipro,Philips or equivalent Make :-Tisva ,Panasonic Philips or its equivalent as approved by Er-In-Charge( Five year warranty)
Supplying and fixing followig type surface round type LED dowlight ,6000k , and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy y>100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz,with three year warranty complete with all accessories, connections, testing and commissioning etc.Make Panasonic,Wipro Philips or its equivalent as approved by Engineer-in-Charge( Five year warranty)
Supplying and fixing of LED bulk head fitting with all accessories including making connections, testing etc. as required Make Panasonic,Wipro Philips or its equivalent as approved by Engineer,in-Charge( Five year warranty)
Supplying and fixing of fancy wall bracket of chrome finish colour with opal glass diffuser made of mild steel, with single holder containing thread type LED lamp holder(s) of all sizes and shapes, complete with all accessories but excluding led lamp including making connections, testing etc. as required.: Make Philips,Jaquar Tisva or its equivalent as approved by Engineer-in-Charge( Five year warranty)
Providing and fixing of following type surface mounted Luminaire LED batten ,having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. Power Factor >.9,Harmonic Distortion>15% and efficiency >100Lumens per watt ,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc as:Make Philips,Panasonic jaquar or its equivalent as approved by Engineer-in-Charge( Five year warranty)
Supplying and fixing batten/ angle holder including connection etc. as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) or its equivalent as approved by Engineer-in-Charge
Supplying and fixing true power make advanced earthing system having copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 13 inch dia as required complete in all respect. make :-True power ,Earth plus,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as requiredMake L&T, Legrand ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139 (EVA,Power & Control System,Supertech make or its equivalent as per best satisfaction of Engineer-in -charge
300 mm Deep
Providing and fixing 125 Amp rating and 25 kA breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as requiredMake L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
S/F indicator set RY&B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar,interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
MCBDB 12 WAY
MCBDB 16 WAY
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Single pole
Triple pole and Neutral
Supplying and fixing pole blanking plate in the existing MCB DB complete etc. as required.:-Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Supplying and fixing of following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.-Make L&T, Schneider,ABB or its equivalent as per best satisfaction of Engineer-in -charge.
Providing and installation of stationary storage type Electric water heater (Geyser)of following capacity various sizes by means of expansion-bolts with nuts and washers, includingembedding of expansion-bolts in the wall, making good the damages, electricalc onnections, testing etc. complete as required:-Make:-Usha,Bajaj,Recold or its equivalent as per best satisfaction of Engineer-in -charge.
6 litre
25 litre
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-Make:Finolex ,KEI,Plaza or its equivalent as per best satisfaction of Engineer-in -charge.
Armoured cable 25 sqmm
Krishan Pal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.25 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .