Loading…
Loading…
Tender Value
₹11.6 L
EMD Value
₹23,250
Closing Date
9 Jul 2026, 3:00 pmDue tomorrow
Executive Engineer
Electrical Division -02, Vikas Minar
Supply and Replacement of split type Air conditioner and electrical items at DDA Roshanara Club.
2026_DDA_915466_1
18/EE(E)/ELD-2/DDA/2026-27
Open Tender
Electrical Works
30 days
As per tender documents
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹23,250
2 Jul 2026
2 Jul 2026
10 Jul 2026
2 Jul 2026
9 Jul 2026
2 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Replacement, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). etc as complete as required.
A) 2.0 TR with 5 Star BEE Rating | 11 | Each | 57,396 | ₹6,31,356 |
| 2 | Supplying and fixing of electronic voltage stabilizer 5 KVA (Copper)suitable for air conditioner connection testing etc as complete as required. | 11 | Each | 7,888 | ₹86,768 |
| 3 | Supplying , Replacement, Testing and Commissioning of suitable size extra Refrigerant copper Pipe as per split AC requirement etc as complete as required. | 132 | mtr | 2,000 | ₹2,64,000 |
| 4 | Supplying and installation of wall/roof mounted stand made out of M S angle duly powder coated suitable to accommodate split type air conditioner (Outdoor unit) etc. as required. | 11 | Each | 1,200 | ₹13,200 |
| 5 | Supplying , Replacement, Testing and Commissioning of suitable size Drain Pipe For 2 TR Air Conditioner etc as complete as required. | 80 | mtr | 107 | ₹8,560 |
| 6 | Supply & laying i/c end termination of XLPE insulated armoured aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV grade i/c connection testing etc.as required.
A) 4C x16 Sqmm | 250 | mtr | 452 | ₹1,13,000 |
| 7 | Supply and drawing 3 core x 2.5 sqmm copper multicore round cable etc as complete as required . | 200 | mtr | 228 | ₹45,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.24 MB
BOQ_962069.xls
BOQ • 0.31 MB
NIT18.pdf
Tender Documents • 5.79 MB
Download all tender documents and submit your bid