Loading…
Loading…
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
9 Jul 2026, 6:00 pm4d left
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
REPAIR AND REPLACEMENT OF FLAME PROOF LIGHT FITTING/FIXTURES, U/S LIGHT WITH ENERGY EFFICIENT LED LIGHT FITTINGS AT ZONE -II AREA UNDER THE JURISDICTION OF GE (A) JAISALMER
2026_MES_773729_1
84443/C/E8
Open Tender
Electrical and Maintenance Works
270 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹60,000
Yes
20 Jun 2026
20 Jun 2026
11 Jul 2026
20 Jun 2026
9 Jul 2026
4 Jul 2026
20 Jun 2026 - 25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/concealed conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc removing materials for taking credit and making good disturbed surface of walls,floors etc complete all as specified and directed by Engineer-in-Charge. | 120 | PER POINT | 99 | ₹11,880 |
| 2 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description alongwith MCCBs as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-Charge. | 70 | EACH | 100 | ₹7,000 |
| 3 | M&L for point wiring complete with and including single core PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables FRLSH 2.5 sqmm (22/0.30mm) 1100 volts grade drawn through and including ERW steel conduit 20 mm or higher dia as required at site, fixed on surface of walls/columns/beams/tie beam etc; by means of saddles and clips etc; including all conduits accessories / fittings / junction boxes/inspection covers etc.; of heavy grade, ISI marked and sunk terminal boxes factory made 16 SWG pressed steel housing, totally concelaed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk /cup washers, for mounting of switches, sockets fan regulators etc; including 2.5 sqmm (14/0.30mm) 1100V grade PVC insulated, unsheathed flexible multistranded copper conductor cable as continuous earthwire connected to metallic bodies of Iuminaires/fans etc; at one end and to common earth dolly at other end, complete all as specified and directed by Engineer-in-Charge and shown on drawings for :- | - | - | - | - |
| 4 | All as per serial item No. 3.00 here-in-befre above but One light point controlled by one, one way switch | 40 | POINT | 100 | ₹4,000 |
| 5 | All as per serial item No. 3.00 here-in-befre above but two light points controlled by one, one way switch | 40 | POINT | 100 | ₹4,000 |
| 6 | All as per serial item No. 3.00 here-in-befre above but three light points controlled by one, one way switch | 20 | POINT | 100 | ₹2,000 |
| 7 | All as per serial item No. 3.00 here-in-befre above but four light points controlled by one, one way switch | 20 | POINT | 100 | ₹2,000 |
| 8 | S&F submain wiring with cable insulated single core multistranded copper conductor cable 1100 volts 2 x 4 sqmm drawn through 20 mm dia Steel ERW Conduit on Surface alongwith 4.0 sqmm copper conductor cable for earth continuity including taking down old unserviceable sub-main wiring complete all as specified and directed by Engineer-in-Charge. Note : 2 runs of 4.0 sqmm cable one run of 4.0 sqmm cable and one run of Steel ERW Conduit will be measured as one RM. | 300 | RM | 100 | ₹30,000 |
| 9 | S&F submain wiring with cable insulated single core multistranded copper conductor cable 1100 volts 2x 6 sqmm drawn through 20 mm dia Steel ERW Conduit on Surface alongwith 6.0 sqmm copper conductor cable for earth continuity including taking down old unserviceable sub-main wiring complete all as specified and directed by Engineer-in-Charge. Note : 2 runs of 6.0 sqmm cable, one run of 6.0 sqmm cable and one run of Steel ERW Conduit will be measured as one RM. | 400 | RM | 100 | ₹40,000 |
| 10 | S & F submain wiring with cable insulated single core multistranded copper conductor cable 1100 volts 4 x 6 sqmm drawn through 25 mm dia Steel ERW Conduit on Surface alongwith 6.0 sqmm copper conductor cable for earth continuity including taking down old unserviceable sub-main wiring complete all as specified and directed by Engineer-in-Charge. Note : 4 runs of 6.0 sqmm cable, one run of 6.0 sqmm cable and one run of Steel ERW Conduit will be measured as one RM. | 120 | RM | 100 | ₹12,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_866355.xls
BOQ • 0.25 MB
TENDER_84443.pdf
Tender Documents • 3.34 MB
Download all tender documents and submit your bid