Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasoanble | |
| 2 | L2₹24.3 L+₹3.3 L (15.7%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹24.8 L+₹3.8 L (17.9%)Rejected-Finance | L3 | Rejected-Finance In order but L3 |
Tender Value
₹31.5 L
EMD Value
₹62,940
Closing Date
7 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
SPL REPAIR / REPLACEMENT OF OLD DAMAGE LT OH LINE, STREET LIGHT AND ALLIED ITEMS AT NODE AREA AND EKNATH ENCLAVE AT 581 SUB GP DABATHWA AND CERTAIN OTHER SANCTIONED WORKS UNDER GE (U) MERRUT CANTT
2025_MES_696957_1
8673/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE (U) Meerut Cantt
₹62,940
Yes
23 Apr 2025
7 Feb 2025
14 Mar 2025
7 Feb 2025
7 Mar 2025
21 Feb 2025
Amount
Supplying, installing, commissioing and testing of LT switchgear panel board of size 1100mmx1400mmx500mm (min) , IP-65 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , having busbar chamber for and including 300 Amps insulated Aluminium bus bars , 4 pole , cubical type, factory made out of 3.15mm thick CRCA sheet structure mounted on Platform (as per Sketch produced by contractor at time of execution), rigid mid steel angle iron frame of 50mmx50mmx5mm with 750mm long extended legs grouting in PCC platform And plateform bottom area bounded with single brick work & filled with sand from which cables enter into panel bottom, duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof with10 watt LED light with holder in panel upper side with ,complete including suitable size cable allay, lugs , cable glands and making connections , wiring with suitable size SC PVC insulated copper conductor cable size not less than 2.5 sqmm and proper copper conductor wiring for Neutral CT with every outgoing MCCB, l65mm size lock with keys comprising of the followings and specified hereafter:-
Outgoing:- (i) FP MCCB with built-in LSIG Electronic trip unit ETS 6, 4 pole, 100Amps, 415V, 25KA (Ics=100%Icu), 50 Hz with Microprocessor based with Neutral CT 300 Amps,- Schneider/ Legrand/ ABB-01 Nos. (ii) FP MCCB with built-in LSIG Electronic trip unit ETS 6, 4 pole, 63 Amps, with astronomical automatic timer of 12 kw, 415V, 16KA (Ics=100%Icu), 50 Hz with Microprocessor based with Neutral CT 63 Amps,Schneider/ Legrand/ ABB, -03Nos. Drawings of LT panel shall be got approved from GE before placing order for procuring.
Excavation in truches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing foundation pole/stay assembly and laying/taking out cables complete all as specified and directed.
All as per item No 2 above but in Hard/ dense soil including cutting of roads/ PCC Floors etc
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L for Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
M & L for Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other complete all as specified and directed.
Supply & Laying jointing, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area conductor through pipes, induct, on poles, in trenches etc including taking down ACSR CONDUCTOR/ OLD CABLE complete of following sizes
185 Sqmm, 3.5 core.
50 Sqmm, 3.5 core.
16 Sqmm, 4 core.
Supply & Laying jointing, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area conductor through pipes, induct, on poles, in trenches etc complete of following sizes
50 Sqmm, 3.5 core.
70 Sqmm 3.5 core
150 Sqmm 3.5 core
240 Sqmm 3.5 core
Supply & fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing alongwith MS clamp with nut & bolts of any size as required at site etc of following sizes including dismantling and taking down existing pipe.
80mm bore
40mm bore
Supply & fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes
80mm bore
50mm bore
Supplying fixing in repair connecting and testing of energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium with toughened glass cover housing, 70/72 watts LED to achieve electrical safety class 1, CRI>70 colour temperature 5000k to 6000k with LED working life time >50000 burning hours with integrated constant current electronic driver, nominal volatge 240V, AC,50 Hz, operating voltage range 120-280V, suitable for ambient environmental condition of station, TDH<10%,, Pf >0.95, lumens >80 lm/W, Ingress protection not less than IP65, driver and luminaire shall comply not less than LM-79 or IS 16106 of 2012 & IS 15885 Part- 2/ Sec 2012 ( procuce LM-079 & 80 testing sheet at the time of execution) and making connections with cable complete all as specified and directed.
S&F in repairs 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings to junction box complete all as specified and directed.
M & L for boaring in any type of soil under road upto 1.5 mtr below the top surface of road by conventional method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
S&F FRP pole mounting type junction box factory made of size 300x200x105mm with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps 'C' series, 10 kA, suitable for domestic loading -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete including taking down old box all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
M& L for earthling complete with galvanized steel earth plate, electrode 600 x 600x6 mm thick , buried directly under ground (earth pit not less than 2.25 m below ground level ) with top edge of the plate not less than 1.5 below ground level connected to galvanized strip 32x6mm(Up to 7.5 Meters) by means of nuts, bolts, check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No 3 on Sl. Page No-497 of MES schedule 2009 part I and connected to existing equipment/system, including all necessary excavation & earth work in hard/dense soil, common salt and charcoal dust mixed & packed 150 mm thick homogeneous layer at alternate quantity all around the GI earth plate, GI protection pipe 40mm light grade upto 7.5 meter from electrode complete all as specified & shown on drawings with watering pipe medium grade 20mm dia ,GI sheet funnel with wire mesh ,RCC precast cover 1:2:4 type B1 duly reinforced with TMT bar 8mm dia at the rate of 150mm centre to centre both ways with suitable lifting handle ,pit/chamber in PCC 1:3:6 type C1 ,Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed.
S&F 40 mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.50 M duly bended and fabricated to 120 Degree to shape consisting adapter (where required ) to suit the opening of street light fitting, mounting brackets made out of 350 mm long or higher mild steel FI 40x6 mm required shape ( two Nos per GI pipe brackets ) duly fitted with 4 nos Mild steel bolts 10mm dia ,50mm long with nut and washers to poles etc. and painting with two coats of synthetic enamelled paint over one coat of red oxide primer complete all as specified.
M&L for point wiring complete with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 2.50 sqmm nominal cross sectional area single core drawn in and including not less than 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, complete including 2.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories from DB box MCB complete all as specified and directed.
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed including taking down of existing unserviceable old MCB any capacity.
Supply & fixing Sheet Metal Enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections inluding taking down Old U/S AC box complete all as specified & directed.
S&F Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed/concealed complete to walls and ceilings or laid in floors and testing complete all as specified and directed.
S&F stop valve/angle valve 15 mm nominal bore cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F 450 mm long PVC steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water and fixed complete all as specified and directed.
S&F in position of CP brass wall mixer two way of 15 mm bore of pipe for mixing of hot and cold water screwed down or Iron pipes and fixed complete(Surface/Consealed all asper site requirement) as specified and directed.
Supply and fix electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified & directed.
Supply, Installation, Testing and commissioning of servo controlled voltage stabilizer (confirming to BIS 9815 (part-I0 1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50 Hz, naturally oil cooled, indoor type unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up top having including following specification:- complete all as specified and directed Engr-in- Charge (a) Capacity 50 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage - 340-460V, Input Frequency 50 Hz (d) Output voltage - Stabilized at any designed /desired voltage 415/+ or - 1% (e) Rated frequency -50Hz (f) wave form distortion- Nil (g) Response time -no to exceed 20 milli seconds (h) sensitivity -(+/-) 1%
(j) Rate of correction - not less than 6 volt / second between phase and neutral (k) Efficiency - more than 95 % (l) Type of load - Three phase , un balanced type (m) Metering- Digital display volt metere/ Ammeter with multi functional meter (n) Operating temperature - for indoor use up to max ambient temp + 55◦C (o) Class of insulation - Class F (p) Made of operation Automatic / manual (q) Winding temperature rise - max 55◦C (10◦C above operating temp) (r) Transformer Oil -Is 335 Marked (s) Core - CRGO M4 Grade /CRNO (cold roll Grain Oriented ) / Cold Rolled Non Oriented ) (t) Auto Transformer - 100 percent copper wound Electrolytic Grade (u) Losses - As per IS Norms (v) Power factor - Not less than 0.95 (w) Protection :- Over load, Short Circuit, High/ Low voltage cut off , By Pass arrangement in case of Emergency, Single phase sequence change / phase fail protection and earth fault protection with indicating alarm system (x) Standard fitting & Accessories e.g Markin plate, Liffting Ligs, CI Rollers, Earthing Teminals etc cable box
Supply, Installation, Testing and commissioning of servo controlled voltage stabilizer (confirming to BIS 9815 (part-I0 1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50 Hz, naturally oil cooled, indoor type unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up top having including following specification:- complete all as specified and directed Engr-in- Charge (a) Capacity 100 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage - 340-460V, Input Frequency 50 Hz (d) Output voltage - Stabilized at any designed /desired voltage 415/+ or - 1% (e) Rated frequency -50Hz (f) wave form distortion- Nil (g) Response time -no to exceed 20 milli seconds (h) sensitivity -(+/-) 1%
(j) Rate of correction - not less than 6 volt / second between phase and neutral (k) Efficiency - more than 95 % (l) Type of load - Three phase , un balanced type (m) Metering- Digital display volt metere/ Ammeter with multi functional meter (n) Operating temperature - for indoor use up to max ambient temp + 55◦C (o) Class of insulation - Class F (p) Made of operation Automatic / manual (q) Winding temperature rise - max 55◦C (10◦C above operating temp) (r) Transformer Oil -Is 335 Marked (s) Core - CRGO M4 Grade /CRNO (cold roll Grain Oriented ) / Cold Rolled Non Oriented ) (t) Auto Transformer - 100 percent copper wound Electrolytic Grade (u) Losses - As per IS Norms (v) Power factor - Not less than 0.95 (w) Protection :- Over load, Short Circuit, High/ Low voltage cut off , By Pass arrangement in case of Emergency, Single phase sequence change / phase fail protection and earth fault protection (x) Standard fitting & Accessories e.g Markin plate, Liffting Ligs, CI Rollers, Earthing Teminals etc cable box
All description same as per Sr item No 27 above but of capacity 200 KVA complete all as specified and directed.
Supply and lay pipe galvanized, “Light grade”, including fittings 100 mm (4”) dia for cable protection compleate all as directed by Engr-in-charge
M & L for Gun metal gate valve with iron wheel head screwed both ends for iron pipe including testing of following :-
50mm dia bore
25mm dia bore
Material and labour for boring in existing water line of size 150mm by threading of size 25mm complete with fixing MS Clamp, nipple reducer to increase the size 25 to 50mm GI pipe including nuts, bolts and washer complete set to work all as directed at site.
S & F GI tubing for following sizes, medium grade, ISI marked complete with all fitting, laid in trenches complete all as specified and directed:-
50mm dia bore
25mm dia bore
Material and labour for construction of valve pit chamber of size 1.0 X 1.0 X 1.0 M (internal dimensions ) including all excavation and earth work in any type of soil and disposal of soil to a distance of not exciting 50 mtr and depositing all as directed including 10mm plastering internally in CM 1:4, PCC 1:4:8 (100mm thick) at bottom and 50mm on top of valve pit, and MS sheet 3mm thick at with angle iron frame 35 X 35X 5mm and 40X 40X5mm at bottom for minting and MS sheet cover inlet. MS handle and locking arrangement including black synthic enamel paint over a coal of red oxide primer on steel surface complete.
M & L for cement concrete type B-1 1:2:4 (20mm grade stone aggregate) as in path and plinth protection (of any section) including chambers weatherings, throating etc and setting in mortar complete all as specified and directed.
Surface excavation n exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete
M &L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment coloured , reflective type of approved quality and vibrated with mechanical vibrator complete all as specified and directed
M&L for sand filling under floor in foundations including watering and cansolidation complete.
M&L for hard core of broken bricks of guage exc 63 mm, but not exc 100mm, deposited spread , and levelled in layers n.exc 15 cm thick, watered and rammmed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2, using 40 mm graded stone agg as in sub base etc complete all as specified and directed.
M&L PCC 1:4:8 type D-2 as in foundation and mass concrete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out, returning, filling in and rammming earth and removing surplus soil to a distance not exc.. 50 m in soft/loose soil complete all as specified and directed.
S&F mild steel work in tubular trusess incl special shape washer etc. conmfirming to IS 1161-1979 grade St-240 complete all as specified and directed.
M&L for pre painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding/ ridge to wall, fixed with self tapping screws complete all as specified and directed.
M&L for brick work with fly ash 'B' bricks, straight or curved on plan exceeding 6 meter mean radius built in CM 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick plaster in CM 1:4 on fair faces of brick work/ concrete surface finished even and smooth without using extra cement complete alll as specified and directed.
M&L for two coats of cement base paint over one coat of cement primer on wallls including preparation of surfaces completre all as spedified and directed.
M&L for preparation of new steel surface over 10 cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer completre all as spedified and directed.
abhinav enterprises (BID ID -3251987)
NITHYA INFRATECH (BID ID -3252066)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .