| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Firm has not uploaded the valid approval letter for soil investigation |
| 4 | Rejected-Technical | Rejected-Technical Firm has not uploaded the soil approval letter |
Tender Value
Refer Docs
Closing Date
28 May 2024, 9:00 amClosed
GE 874 EWS
GE 874 EWS, Kupwara
Provn of Boundary wall with security light, Pole, Watch tower with Svl Camera and Control Room for Inf Bn Baghbella and Provn of store shed with allied Infra for storage at Tangdhar under GE 874 EWS
2024_MES_652615_1
3009/A/03/E3
Open Tender
Civil Works
Works
60 days
Baghbella and Tangdhar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
8 Jun 2024
7 May 2024
29 May 2024
7 May 2024
28 May 2024
10 May 2024
Amount
PROVN OF BOUNDARY WALL WITH SECURITY LIGHT, POLE, WATCH TOWER WITH SVL CAMERA AND CONTROL ROOM FOR INF BN BAGHBELLA. Determination of safe bearing capacity of soil by mean of boring 100 to 150mm dia 02 holes upto 7 mtr depth/ refusal and performing standard penetration test (SPT) at suitable interval or in case, gravelly/bounder/ rocky strata encountered before 1.5 mtr depth then open pit upto 2m to 3m depth and DCPT as per IS will be concluded upto 7 mtr or till refusal collection of disturbed/ undisturbed soil samples at various depth of bore holes for laboratory testing i.e grain size analysis attenberg limits, natural density, water contents specific gravity, triaxial shear, free swell index cohension and angle of friction, determination of harmful chemical etc evaluation of safe bearing capacity and strength as per IS 1892:2021.
PROVN OF STORE SHED WITH ALLIED INFRA FOR STORAGE OF DRY SUPPLY AT COMP PL AT TANGDHAR. Determination of safe bearing capacity of soil by mean of boring 100 to 150mm dia 02 holes upto 7 mtr depth/ refusal and performing standard penetration test (SPT) at suitable interval or in case, gravelly/bounder/ rocky strata encountered before 1.5 mtr depth then open pit upto 2m to 3m depth and DCPT as per IS will be concluded upto 7 mtr or till refusal collection of disturbed/ undisturbed soil samples at various depth of bore holes for laboratory testing i.e grain size analysis attenberg limits, natural density, water contents specific gravity, triaxial shear, free swell index cohension and angle of friction, determination of harmful chemical etc evaluation of safe bearing capacity and strength as per IS 1892:2021.
(a) Above test shall be include carrying out SPT and collection of disturbed and undisturbed sample as per relevant IS code. The SPT is required to be taken at 1 mtr interval or at every change of stratum. (b) Carrying out laboratory test with the disturbed/ Undisturbed/sampling and find out grain size analysis gradation properties, Natural Moisture Content, Specific gravity, field density, FMC/MDC/OMC permeability shear and UCT test in the Lab including DCPT and UCT test etc. (c) Evaluation allowable bearing capacity/ SBC of soil by analytical methods. (d) Preparation and submission of consolidated report with photographic record of each bore hole/ plate load test record in hard and soft of of each set in 03 folders for the seperate work etc completed. (e) Above items shall be inclusive of mobilisation/ transportation, labour, soil report (03 folders for each work) and all taxes as applicable.
Following aspects/ points may please be included in test report of bore holes:- (a) In soil test report recommendation of SBC should be given for all the bore holes for minimum three depth i.e 1.5,2.00m and 2.50m. (b) Recommendation of footing type & SBC shall be worked out for minimum foundation of 1.50 x 2.50m 2.00 x 2.50m and 2.00 x 3.00m. (c) All testing shall be carried out as per relevant and latest code provisions. (d) Photographic record of Geo-exploration and testing shall also be a part of Records. (e) Depth of ground water table in peak monsoon and peak summer i.e (highest & lowest) and seasonal variation of water table should be mentioned in report. (f) Recommendations for filling under flooring. (g) Recommendation with respect of liquefaction potential of soil in case of saturated or partially saturated loose/ uncompact sandy soil. (h) Swelling index and swelling pressure in respect of BC soil and its depth/layer.
Research and Engineer Enterprises
Bidder Name
Research and Engineer Enterprises
National Soil Testing and Research Laboratories
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .