| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.2 Cr+₹4.1 L (3.56%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹1.2 Cr+₹4.1 L (3.56%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹1.2 Cr+₹6.2 L (5.34%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹1.2 Cr+₹6.2 L (5.34%) | L3 | Rejected-Finance Being other than lowest |
| 4 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | - | Rejected-Technical Rejected due to not enlisted with eligible category |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical Rejected due to DD submitted in favour of GE Karwar |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
28 Apr 2023, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
SPECIAL REPAIRS OF FIRE FIGHTING SYSTEM TO F3 TO F6 AT OLD NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2023_MES_581758_2
8316/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (NW) Navy Nagar, Colaba
Class B and category a(ii) and c(vi)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹1.9 L
Yes
22 Jun 2023
8 Apr 2023
29 Apr 2023
8 Apr 2023
28 Apr 2023
22 Apr 2023
8 Apr 2023 - 28 Apr 2023
Amount
Supply and replacement, installation, testing & commissioning of addressable micro processor based 2 wire fault tolerant loop, required loop net workable type 2 loop (each loop accessing maximum 99 detectors and 99 modules) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault signal with address. The panel shall have rectifier, loop cards, LCD display unit to indicate Fire/Fault signal with address. The panel shall have a built in power supply and battery charger alongwith maintenance free SMF lead acid batteries as per manufacturers design with battery charger complete as required and as per specifications duly approved by EN 54 complete including making connections all as specified and directed by Engr-in-Charge. Make :- Morley-IAS by Honeywell model Name/Number. DXc2/ 714-001-225 or Bosch model No. FPA-1000-V2 / Schneider cat No : FFSULH1002 Model No ESM, ULTIMA
Supply and fix in repair Addressable manual call point resettable type complete all as specified and directed
Supply and fix in repair Addressable sounder range 900 dbl with strobe complete all as specified and directed
Supply and fixing in repair red colour PVC insulated PVC sheathed un-armoured copper conductor cable of size 2Core x 1.5 Sqmm including fixing on walls with saddles not more than 60 cm intervals complete all as specified and directed.
Supply and fixing in repair detectors Complying with and type certified to EN - 45 Addressable type optical multi Sensor detector heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed.
Supply and fixing in repair addressable fault Isolator suitable for fire alarm system complete all as specified and directed.
Supply and fixing in repair addressable control module suitable for fire alarm system complete all as specified and directed.
M&L for earthing complete with galvanized earth plate 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level connecting with 4 mm dia GI wire by means of bolts nuts, check nuts and washers of galvanized iron all shown in electrical plate No 03 of SSR Part-I including necessary excavation earth work using PCC 1:2:4 for earthing pit and pit cover with handle of 8mm dia MS rod and connected to test point all as specified and directed. Note : (a) The item rate inclusive of fixing of earth continuity conductor from earth plate upto 7.5 mtr. (b) The item rate inclusive of provisioning necessary charcoal and salt upto the level of the earth plate in alternate layers.
M&L for earthing complete with galvanized earth plate 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level connecting with 25 x 4 mm GI strip by means of bolts nuts, check nuts and washers of galvanized iron all shown in electrical plate No 03 of SSR Part-I including necessary excavation earth work using PCC 1:2:4 for earthing pit and pit cover with handle of 8mm dia MS rod and connected to test point all as specified and directed. Note : (a) The item rate inclusive of fixing of earth continuity conductor from earth plate upto 7.5 mtr. (b) The item rate inclusive of provisioning necessary charcoal and salt upto the level of the earth plate in alternate layers.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on FRP insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x4 mm galvanised iron or steel strip complete all as specified and directed.
Supply, install testing and commissioning of Booster pumps copper wounded for 440 V, 3 Phase, 50 Hz AC Supply with IP-55 protection Confirming to IS- 12469 :1988, Size (mm) Suction x delivery : 80 x65 mm With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 35mtr head, 900 LPM discharge including PCC foundation not less than 20 CM height, pump fixed on angle iron base frame from the manufacturer size and model with vibration pads, PVC insulated and sheathed three core cable of suitable size from starter to pump and Fibre sheet 2 mm thickness for shed not less than 4 sqm with angle iron as required at site for protection of pump from rain and water complete all as specified and directed. Make :- Kirloskar Model No. KDI-1555+ CI MS SS IP55 FCL or equivalent in CG, M/s Wilo mather platt Note :- The item rate also includes PCC foundation, Fibre sheet, angle iron frames, Pump base frame, vibration pads, grouting of nut bolts and three core cable from starter to pump, Air release valve as required at site including testing.
Supply and Fix MCCBs 40 Amp 3 pole 415 volts, 16KA, 50 HZ including factory made SS enclosure fixed on wall and making connections complete all as specified and directed
Supply and fixing MCB double pole 16 Amps, 10 KA, 'C' series with factory made SS enclosure fixed on wall and making connections complete all as specified and directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 4 core fixed on wall with steel saddles as approved by Engineer-in-Charge.
Supply & fix in repair 100 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-1239 and applying two coats of red colour synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets/clamps as required at site complete all as specified and directed.
Supply & fix in repair 80 mm dia ERW MS pipe heavy grade including MS fittings confirming IS-1239 and applying two coats of red colour synthetic enamel paint over a coat of red oxide primer to pipe including welding, supporting brackets/clamps as required at site complete all as specified and directed.
M&L factory fabricated Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified & directed.
Supply & fix in repair rubber hose red in colour pipe 30 mtr,20mm dia plain 2 ply rayon confirming IS-12585 braided high pressure complete all as specified and directed.
Supply & fix in repair canvas fire hose red in colour 63mm bore 15 m long confirming to IS 636-1988 having male/female brass coupling both end complete all as specified and directed.
Supply & fix in repair Stainless steel Nozzle 15 mm bore suitable for 63mm dia canvas pipe complete all as specified and directed.
Supply & fix in repair hose Reel drum with mounting base plate company made suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed.
Supply & fix in repairs Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle complete all as specified and directed.
Supply & fix in repair gun metal Two way fire brigade inlet conection with adaptor of size 80 mm dia X 63 mm dia complete all as specified and directed.
Supply & fix in repair double headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed.
Supply & fix in repair single headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed.
Supply & fix in repair sluice valve 100mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply & fix in repair sluice valve 80mm size both ends flayed with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply and fixing in repairs Ball valves 50 mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms including necessary GI fittings as required at site i.e. elbow, reducer, nipple etc complete all as specified and directed.
Supply & fix in repair Non return valve 80mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
Supply & fix in repair Non return valve 100mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of pipe lines or any other locations as required at site.
S & F SMC panel tank of capacity 12000 ltrs of suitable size, ISI marked in each panel , made up of top and bottom of hot pressed moulded UV stabilized panels and FRP pultrusion section, manhole, sealant and nut and bolt of hot dip galvanised with external reinforcement of steel with anticorrosive paint and connection for inlet/ outlet and overflow of GI flanged type with air vent and water level indicator without glass of FRP including interconnection with GI pipes as per size directed and PCC platform minimum 60 cm height as per required design/ height and providing necessary c-channel base of size 100 x 50mm and glavanised ladder from roof to top of the tank suitable for placing of SMC panel tank complete all as specified and directed. Note :- SMC tank panels should have ISI marked and original make embossing in each panel. Any other left out items required for fixing is deemed to be included in the item rate.
S & F SMC panel tank of capacity 6000 ltrs of suitable size, ISI marked in each panel , made up of top and bottom of hot pressed moulded UV stabilized panels and FRP pultrusion section , manhole, sealant and nut and bolt of hot dip galvanised with external reinforcement of steel with anticorrosive paint and connection for inlet/ outlet and overflow of GI flanged type with air vent and water level indicator without glass of FRP including interconnection with GI pipes as per size directed and PCC platform minimum 60 cm height as per required design/ height and providing necessary c-channel base of size 100 x 50mm and glavanised ladder from roof to top of the tank suitable for placing of SMC panel tank complete all as specified and directed. Note :- SMC tank panels should have ISI marked and original make embossing in each panel. Any other left out items required for fixing is deemed to be included in the item rate.
S&F in repair PVC water storage Tank 5000 ltr capacity 2 layers , ISI marked, hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed.
Supply and fixing in repair steel galvanised pipes medium grade, ISI marked of size 50 mm dia including necessary fittings as required at site complete all as specified.
Supply and fix in repairs in existing line, CP brass gate valve 50 mm bore with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified and directed.
S&F in repair/replacement of Compound girders and stanchions, lattice girders, aerial masts,staging for water tanks , ladders, and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, nuts, bolts, washers etc. including necessary fabrication work with hinges, handle and applying two coats of synthetic enamel paint over one coat of metal primer complete all as specified.
Supply and installation of water flow switch suitable for fire fighting system, pipe size 100 mm dia , operating pressure, withstand pressure as per manufacturer recommendations, including cutting, clamping, welding , control wiring , connecting and testing with all all accessories/items required at site and testing complete all as specified and directed.
ASHOK ENTERPRISES
Idustrial products India
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .