Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 CrAdmitted-Finance 2 ARYA NAGAR NARMADA ROAD JABALPUR 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | ₹5.6 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical RITHANI DELHI ROAD RITHANI MEERUT UTTAR PRADESH 250103 | MEERUT | UTTAR PRADESH | 250103 | - | - | Rejected-Technical PQC NOT QUALIFIED |
| 3 | Rejected-Technical 6 3 8 879 B 3RD FLOOR PULLA REDDY SWEETS BUILDING GREENLAND ROAD BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | - | - | Rejected-Technical PQC NOT QUALIFIED |
| Sl No | Description | Qty | Unit | Bharat Heavy Electricals Limited L1 |
|---|---|---|---|---|
| 1.00 | 40 MVA, 132/6.9 KV, 3 Phase CW Transformer Designing, manufacturing, testing, supplying, transporting and unloading of 40 MVA, 132/6.9 KV, 3 Phase CW Transformer complete with all accessories, erection gaskets, HV, LV & Neutral Bushing, Oil Pipe lines, Radiator Bank Conservator, Breather, OLTC, RTCC, OTI, WTI, Air Release Devices, PRVs, Drain Valves, Sampling Valves, Buchholz Relay, Isolating Valves etc. including cooling fans and Oil Pumps of Radiator and supporting structures with marshaling kiosk and cooler control cabinets, all required control & power cables from transformer Bushing CT’s, Buchholz, PRV, OTI, WTI, Conservator oil level indicates, Fan/ pumps etc. to CCC/ Marshalling Box etc. above supply scope also includes terminal clamps for HV and LV Bushing as per general technical requirement Part-II. Insulators and flexible connector etc. for neutral bushing and its earthing is also included. | 1 | Nos. | 4,22,09,000 ₹5,11,41,200 Lowest |
| 2.00 | Supply of Transformer Oil: EHV grade confirming to IS: 335 1993 transformer oil
Note:- 01 lot will consists of transformer oil for first filling of CW transformer plus 10% extra in barrels of 209 Ltr. | 1 | Lot | 22,21,000 ₹26,20,780 Lowest |
| 3.00 | Manufacturing & Supply of Non magnetic metallic enclosure complete with all fixing hardware for completely enclosing all the three LV Bushings and for connecting with LV Bus duct on one side transformer main tank on the other side. | 1 | Nos. | 1,60,000 ₹1,97,532 Lowest |
| 4.00 | Supply of Maintenance spares:- One set consists of following Parts:- (a) One set of complete erection gasket (b) OTI- 01 nos, (c) WTI - 01 nos, (d) Magnetic oil level indicator for conservator - 01 nos (e) Spare cooling fans - 06 nos (f) PRV - 01 nos (g) Buchholz relay for main transformer conservator line-01 no (h) Buchholz relay for OLTC conservator-01 nos | 1 | set | 1,98,000 ₹2,43,670 Lowest |
| 5.00 | Shifting of supplied transformer from unloading point/place to the plinth, Erection, testing and commissioning of supplied transformer complete with fittings and accessories including
OLTC local and remote Tap changer, central cubical cooler control cabinets, marshalling box and associated control power cabling etc. as per scope of work mentioned in the tender specification | 1 | Job | 19,00,000 ₹22,42,000 Lowest |
Tender Value
₹3.3 Cr
EMD Value
₹3.5 L
Closing Date
8 Mar 2021, 4:00 pmClosed
SE
office of SE,MMC-I,ATPS,ANPARA
Designing, Manufacturing, Testing, Supplying, Transporting and Unloading of 40 MVA, 132/ 6.9 KV, 3 Phase CW Transformer for 3x210 MW ATPS Anpara
2021_RVUNL_546987_1
413/PD-I/ATPS/2020-21
Open Tender
Electrical Work/ Equipment
Fixed-rate
180 days
Anpara
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹5,900
DY CAO,CFA AND BO,ATPS
₹3.5 L
Anpara
31 May 2021
19 Jan 2021
10 Mar 2021
19 Jan 2021
8 Mar 2021
19 Jan 2021
19 Jan 2021 - 6 Mar 2021
8 Feb 2021
Amount
40 MVA, 132/6.9 KV, 3 Phase CW Transformer Designing, manufacturing, testing, supplying, transporting and unloading of 40 MVA, 132/6.9 KV, 3 Phase CW Transformer complete with all accessories, erection gaskets, HV, LV & Neutral Bushing, Oil Pipe lines, Radiator Bank Conservator, Breather, OLTC, RTCC, OTI, WTI, Air Release Devices, PRVs, Drain Valves, Sampling Valves, Buchholz Relay, Isolating Valves etc. including cooling fans and Oil Pumps of Radiator and supporting structures with marshaling kiosk and cooler control cabinets, all required control & power cables from transformer Bushing CT’s, Buchholz, PRV, OTI, WTI, Conservator oil level indicates, Fan/ pumps etc. to CCC/ Marshalling Box etc. above supply scope also includes terminal clamps for HV and LV Bushing as per general technical requirement Part-II. Insulators and flexible connector etc. for neutral bushing and its earthing is also included.
Supply of Transformer Oil: EHV grade confirming to IS: 335 1993 transformer oil Note:- 01 lot will consists of transformer oil for first filling of CW transformer plus 10% extra in barrels of 209 Ltr.
Manufacturing & Supply of Non magnetic metallic enclosure complete with all fixing hardware for completely enclosing all the three LV Bushings and for connecting with LV Bus duct on one side transformer main tank on the other side.
Supply of Maintenance spares:- One set consists of following Parts:- (a) One set of complete erection gasket (b) OTI- 01 nos, (c) WTI - 01 nos, (d) Magnetic oil level indicator for conservator - 01 nos (e) Spare cooling fans - 06 nos (f) PRV - 01 nos (g) Buchholz relay for main transformer conservator line-01 no (h) Buchholz relay for OLTC conservator-01 nos
Shifting of supplied transformer from unloading point/place to the plinth, Erection, testing and commissioning of supplied transformer complete with fittings and accessories including OLTC local and remote Tap changer, central cubical cooler control cabinets, marshalling box and associated control power cabling etc. as per scope of work mentioned in the tender specification
Bidder Name
Bharat Heavy Electricals Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
Tendernotice_2.pdf
PDF • 1.98 MB
CWSpecificationTender.pdf
Tender Documents • 1.96 MB
BOQ_830014.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .