| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹47.3 L+₹2.1 L (4.64%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹47.6 L+₹2.4 L (5.21%)Rejected-AOC | L3 | Rejected-AOC Higher bid value |
| Sl No | Description | Qty | Unit | SAYED ALI AND SONS L1 | das enterprises L3 | Kalim sons L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and as directed. | 60 | CUM | 1,150 ₹69,000 | 66 ₹3,960 Lowest | 1,200 ₹72,000 |
| 2.00 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level.(Reinorcement cut as required to facilitate demolition) etc complete all as specified and as directed. | 2 | CUM | 1,300 ₹2,600 Lowest | 2,100 ₹4,200 | 1,350 ₹2,700 |
| 3.00 | M&L for cement concrete (1:3:6) type C-2(using 40 mm graded stone aggregate) 150mm thickness as in bed to drain pipes, including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed. | 960 | RM | 650 ₹6,24,000 | 560 ₹5,37,600 Lowest | 700 ₹6,72,000 |
| 4.00 | M&L for DWCPE (SN8) 180 (OD) mm diameter Pipes including fittings and laid in trenches as in sewer lines complete with testing on completion and making the line functional including demolition of existing pipe of any type and size etc complete all as specified and as directed.
. | 650 | RM | 750 ₹4,87,500 | 1,150 ₹7,47,500 | 700 ₹4,55,000 Lowest |
| 5.00 | M&L for DWCPE (SN8) 160 (OD) mm diameter Pipes including fittings and laid in trenches as in sewer lines complete with testing on completion and making the line functional including demolition of existing pipe of any type and size etc complete all as specified and as directed.
. | 370 | RM | 550 ₹2,03,500 | 1,100 ₹4,07,000 | 500 ₹1,85,000 Lowest |
| 6.00 | Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 150 mm dia laid in trenches or floors etc complete all as specified and as directed. | 100 | RM | 500 ₹50,000 Lowest | 1,150 ₹1,15,000 | 550 ₹55,000 |
| 7.00 | Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 110 mm dia laid in trenches or floors etc complete all as specified and as directed. | 140 | RM | 400 ₹56,000 Lowest | 520 ₹72,800 | 500 ₹70,000 |
| 8.00 | Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 110 mm dia fixed to walls etc complete all as specified and as directed. | 200 | RM | 400 ₹80,000 Lowest | 510 ₹1,02,000 | 500 ₹1,00,000 |
| 9.00 | Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 75 mm dia fixed to walls etc complete all as specified and as directed. | 100 | RM | 290 ₹29,000 Lowest | 355 ₹35,500 | 300 ₹30,000 |
| 10.00 | Supply and fixing as in replacement 100mm dia grating doom with waste hole of PTMT (minimum weight 25gms) complete all as specified and as directed by the Engr-in-Charge. | 50 | EACH | 200 ₹10,000 | 62 ₹3,100 Lowest | 200 ₹10,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR MAINT CLEANING OF SEWAGE LINE SEPTIC TANK SOAKAGE WELL IN SW ZONE AT RMS
2025_MES_716600_2
8909/C/E8
Open Tender
Civil Works
Item Rate
270 days
RANGAPAHAR
Class D, Category a(ii)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹90,000
11 Sept 2025
8 Aug 2025
29 Aug 2025
8 Aug 2025
27 Aug 2025
14 Aug 2025
8 Aug 2025 - 12 Aug 2025
Amount
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level.(Reinorcement cut as required to facilitate demolition) etc complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C-2(using 40 mm graded stone aggregate) 150mm thickness as in bed to drain pipes, including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed.
M&L for DWCPE (SN8) 180 (OD) mm diameter Pipes including fittings and laid in trenches as in sewer lines complete with testing on completion and making the line functional including demolition of existing pipe of any type and size etc complete all as specified and as directed. .
M&L for DWCPE (SN8) 160 (OD) mm diameter Pipes including fittings and laid in trenches as in sewer lines complete with testing on completion and making the line functional including demolition of existing pipe of any type and size etc complete all as specified and as directed. .
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 150 mm dia laid in trenches or floors etc complete all as specified and as directed.
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 110 mm dia laid in trenches or floors etc complete all as specified and as directed.
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 110 mm dia fixed to walls etc complete all as specified and as directed.
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 75 mm dia fixed to walls etc complete all as specified and as directed.
Supply and fixing as in replacement 100mm dia grating doom with waste hole of PTMT (minimum weight 25gms) complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair 110/150 mm bore stack clamps out of 25mm by 3mm flat iron and round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore etc complete all as specified and as directed.
S & F in repair PVC (SWR) bends any radius 110 mm dia etc complete all as specified and as directed.
S & F in repair PVC (SWR) bends any radius 75 mm dia etc complete all as specified and as directed.
S & F in repair 110mm dia PVC (SWR) branch piece, single (single Y equal or unequal) etc complete all as specified and directed.
S & F in repair 75 mm dia PVC (SWR) branch piece, single (single Y equal or unequal) etc complete all as specified and directed.
S & F in repair 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repair PVC Gully trap 125/110mm, setting and jointing with solvent cement etc complete all as specified and directed.
Material and labour for brick work (using old size burnt bricks) in cement mortar1:6 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius including demolition of old brick work etc complete all as specified and directed.
M & L for rendering in 10 mm thick in cement mortar (1:6) other than fair faces of brick work, finished even and smooth without using extra cement including taking down old plaster etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in copings including necessary formwork etc complete all as specified and directed.
Material and labour for deformed steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking endsand binding with mild steelwire (annealed) n.less than 0.9mm dia etc complete all as specified and directed.
M & L for precast RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in manhole cover set in CM (1:4) including necessary form work etc complete all as specified and directed.
M&L for plain cement cement concrete (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for cement concrete type C-2 (1:2:4) (using 20 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed.
M&L for extra for forming fair finished surfaces of drain or channels, innergirth 30 cms, using extra cement including forms, moulds mitred/ stoppedends etc complete all as specified and directed.
Cleaning of Blockage IWC,EWC, Wash basin, gully trap, floor trap etc either by hand pump or by rodding or by any other means untill clear flow is observed etc complete all as specified and as directed.
Carrying out opening of manholes,sewer line of any type and any depth removing the sludge/solid content from the manhole/sewer line by manual/ mechanical method and also cleaning the sewage line of any dia and at any depth either by water pressure or by any other flushing or roding and other suitable means at the discretion of the contractor at his own arrangements so as to remove the blockage and making the sewer lines and manhole fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in SW Zone complete all as specified and as directed. Note:-The complaint shall be cleared/rectified to the complete satisfaction of Engineer-in-Charge .
Desilting of septic tank of any size, type and any depth and removing the sludge/solid content from the septic tankt by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the septic tank fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab etc complete all as specified and directed.
Desilting of soakage pit of any size, type and any depth and removing the sludge/solid content from the soakage pit by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab etc complete all as specified and directed.
Cutting into exisiting manholes for connecting new drains, making good topipes and rendering ,cutting out existing benching and forming branch channel, halfround or 3/4 section in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) smooth finished and reforming benching as required, internal dia of pipe150mm etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and n.exceeding 1.5m in depth; for foundation , etc not exceeding 10sq.m on plan and not exceeding 1.5m in depth and gettingout insoft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm In soft/ loose soil etc complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point,in soils etc complete all as specified and directed.
S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed including 100mm CI 'P' trap etc complete all as specified and directed.
Supply and fixing as in replacement vitreous China wash down water closet pan (pedestal pattern) 110mm dia bore with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts, with coloured PVC seat cover etc complete all as specified and directed. Make: Parryware Cat No C0278 for water closet, Cat No C8071 EWC Standard for PVC seat cover or equivalent approved make as approved by GE.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm as in floor etc set and jointed in neat cement slurry and pointed in white/coloured cement mixed with pigment to match the shade of tiles laid over and including 15mm thick screed bed in CM (1:6) including demolition of laid bedded and pointed in any mortar Stone slabs and tiles of any description complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm as in floor etc set and jointed in neat cement slurry and pointed in white/coloured cement mixed with pigment to match the shade of tiles laid over and including 15mm thick screed bed in CM (1:6) including demolition of laid bedded and pointed in any mortar Stone slabs and tiles of any description complete all as specified and as directed.
Kalim sons (BID ID -3399699)
das enterprises (BID ID -3397028)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .