| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.9 L+₹4.2 L (32.5%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.0 L+₹8.2 L (64.3%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.8 L+₹10.0 L (78.3%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹26.0 L+₹13.2 L (103.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
9 Dec 2021, 6:00 pmClosed
GE (P) AF GUrgaon
Garrison Engineer (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
GE(P)AF/GUR-66/2021-22 REPAIR/MAINT OF EXTERNAL E/M SERVICES, RO PLANT AND OTHER CONNECTED WORKS AT 27 ED AND 31 MCU AF STN PALAM UNDER GE (P) AF GURGAON
2021_MES_487651_1
GE (P) AF/Gur-66/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹68,000
Yes
27 Jan 2022
11 Nov 2021
11 Dec 2021
11 Nov 2021
9 Dec 2021
25 Nov 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Demoliton of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable and punned down to 18cm, complete all as specified and as directed by Engr-in-charge.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat, complete all as specified and as directed by Engr-in-charge.
Laying old serviceable bricks (retrieved under item 01 of Sch ‘A’, complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:2:4 type B1 using 20mm grade stone aggregate as in copping of electric pole, solar platform or making good of disturbed surface complete all as specified and as directed by Engineer-in-charge.
M&L complete for driling hole hard standing / road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any complete all as specified and directed by Engineer-in-charge. GI pipe shall be measured and paid sepretely.
Supply and lay or fixing or passing through pipe cable XLPE (FRLS) with aluminium conductor with heavy duty stranded,1100 volts size of 16 Sqmm 2 Core including taking out old U/S cable complete all as specified and as directed. Note :- XLPE insulated pvc sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for pvc insulated cables with following :- (a) Cable shall have fire retardate low smoke (FRLS) compound added to it in the inner sheathing and out sheathing as per IEC 754 (part-I) IEC-60332 part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardate compound (PR) as per EIC specification. (b) Inner sheathing shall be of extruded PVC. (c)Heat resisting PVC shall also be added to extruded inner and outer sheathing. (d) Cable shall also be supplied with sequences hal marking at every meter as the outer sheathing. (e) ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) anti rodent and antitermite compound added. (g) pvc compounds of various grades as IS-5831. (h) compaction conductors shall be shaped and arrangement for the same with be on the cable
All as per item No. 10 hereinbefore but size 16 Sqmm, 4 Core .
All as per item No. 10 hereinbefore but size 35 Sqmm, 3.5 Core .
All as per item No. 10 hereinbefore but size 50 Sqmm, 3.5 Core .
All as per item No. 10 hereinbefore but size 120 Sqmm, 3.5 Core .
All as per item No. 10 hereinbefore but size 240 Sqmm, 3.5 Core .
All as per item No. 10 hereinbefore but size 400 Sqmm, 3.5 Core .
M&L for Dismantling of starting system of battery bank including necessary wires and supply and fix new starting system of maint free lead acid battery 12 V ,150 AH 02 Nos Make Exide with copper terminal cable of 16 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal and 0.50 meter for inter connection including necessary brush terminals complete of battery bank including testing, complete all as specified and directed by Engineer-in-Charge. Make Exide/Amaron with 24 months replacement warranttee.
Supply and fixing environmental friendly LED street light of capacity 60W with IP-65 protection 230V complete with drivers and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Halonix CAT No HLSLD-15-60-WWL-RL or equivalent in Havells/Crompton/PHILIPS /Bajaj as approved.
Supply and fixing Environmental friendly LED street light of capacity 90W with IP-65 protection 230V complete with drivers and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Halonix CAT No HLSLD-06-90-WWL-RL or equivalent in Havells/Crompton/PHILIPS /Bajaj as approved.
Supply & Fix in replacement of Environmental friendly LED Flood light of capacity 42/40W with IP-65 protection 230V complete all as specified and as directed by Engineer-in-charge Make :Halonix (CAT No HLSLD-15-45-WWL-RL or equivalent in Havells/Crompton/PHILIPS /Bajaj as approved.
S&F for 150 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Halonix (CAT No HLSLD-06-150-WWL-RL or equivalent in Havells/Crompton/PHILIPS /Bajaj as approved.
S&F in replacement of post top light fitting as per matching to existing type of capacity 40/45W made in die-cast aluminium decorative clear optics IP-65 complete all as specified and as directed by Engineer-in-charge. Make :Halonix CAT No HLSLD-15-45-WWL-RL or equivalent in Havells/Crompton/PHILIPS /Bajaj as approved.
S&F in replacement of 9w LED warm white bollards, integral decorative with opal acrylic with IP-65 protection light fitting complete including necessary connection all as specified and as dirceted. Make : Havells/Crompton/PHILIPS /Bajaj
Supply & Fix copper conductor single core cable of size 2.5sqmm stranded PVC insulated for connection of street light poles complete all as specified and as directed by Engineer-in-charge.
Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310 x 210 x 120 mm made out of engineering plastic one piece moulding Siemens grey colour with hold fast including 4Nos aluminium strips 60 amp of required size fixed on unbreakable insulator and one no single pole MCB 1to3 amp 'C' curve including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCCB 4 pole, 63A, 16KA, fixed in bus bar trunking or in DBs, complete all as specified and as directed by Engr-in-charge. Make Havells IHLGNF0063 or equivalent in makes specified in list of makes.
S&F in replacement of MCCB 4 pole, 125A, 16KA, fixed in bus bar trunking or in DBs, complete all as specified and as directed by Engr-in-charge. Make Havells IHLGNF0125 or equivalent in makes specified in list of makes.
S&F in replacement of MCCB 4 pole, 160A, 25KA, fixed in bus bar trunking or in DBs, complete all as specified and as directed by Engr-in-charge. Make Havells IHLGHF0160 or equivalent in makes specified in list of makes.
S&F in replacement of MCCB 4 pole, 250A, 36KA, fixed in bus bar trunking or in DBs, complete all as specified and as directed by Engr-in-charge. Make Havells IHLFNF0250 or equivalent in makes specified in list of makes.
S&F in replacement of MCCB 4 pole, 400A, 36KA, fixed in bus bar trunking or in DBs, complete all as specified and as directed by Engr-in-charge. Make Havells IHLLSEBF0400 or equivalent in makes specified in list of makes.
Preparation of old painted exposed surface of steel tubular LT poles 9 mtr long with street light brackets etc complete, painting and numbering of poles with existing size and type as under:- (i)from bottom up to 1.2 mtr height one coat of black synthetic enamel high glow paint make berger (ii) 1.2mtr to 1.30mtr height one coat of red & blue luminous paint/tape. (iii)1.30 mtr height to top of the pole two coats of aluminium paint.
S&F street light panel/ feeder box made out of MS/ CRCA sheet 3.15mm thick with MS angle iron frame of size 40x40x6mm outdoor type with locking arrangement of size 0.6mx0.45mX0.35m with powder coating paint including PCC 1:3:6 type C-1 foundation of size 0.60 x 0.45 x 0.35 mtr, copper bus bars and internal wiring & taking down old panel box complete of suitable size with following switchgears accessories:- (a) MCCB 4 pole 415V 63Amps 16KA - 01 No. (b) LED indicator lamp 01 Set. (c) Timer switch- 01 No. (d) 40Amps TP power contactor - 01 No (e) MCB TPN 32Amps - 1No (f) MCB SP 6-32 Amps - 06 Nos (g) Single phase preventor - 1 No.
M&L for defect rectification electric cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments shall be brought to site within the hours of instruction from Engr-in-Charge.
Supply and jointing LT 1100 Volt grade cable straight through heat shrinkable type complete suitable for aluminium conductor cable of size 3.5 Core 120 Sqmm to 400 Sqmm complete all as specified and as directed. Make: Denson/Cabseal/M-Seal
All as per item No. 34 here in before but suitable for cable size upto 70 sq mm.
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
Supply and laying of 2.5 mm thick insulated synthetic mat of confirming to IS 15652 : 2006 and meeting the requirements of IS 5216 (Part 1.2 & 3) IS 8437, IFC-479 Pub-1, alongwith suitable adhesive/chemibound, PU resin, waterproofing compound and sealing material as per in service recommendation of IS : 15652 class – B suitable for working voltage up to 11 KV with trolley movement complete all as specified and as directed by Engineer-in-charge. Make : SAFEVOLT/INSULICA
S&F in replacement of mild steel chequered plates 5 mm thick or over in thickness avilable size duly painted with two coat of black bituminous paint over one coat of red oxide primer and cut to shape for cable duct complete all as specified and directed by Engineer-in-Charge.
S&F GI Tubing medium grade of size 80mm bore for LT cable protection complete all as specified and as directed by Engineer-in-charge.
S&F GI Tubing medium grade of size 50mm bore for LT cable protection complete all as specified and as directed by Engineer-in-charge.
Supply & Fix replacement of Power contactor MNX type MNX-110 with NO+NC. Make:- L&T/ Havells
Supply, laying, jointing and testing in replacement in trenches, galvanized iron water tubing medium grade including provision of all necessary ISI marked GI fittings / accessories including taking out old water lines complete all as specified and directed for the following sizes :-
50 mm bore.
40 mm bore.
25 mm bore.
20 mm bore.
15 mm bore.
Supply, laying, jointing & testing in replacement in trenches cast iron pipes with spigot and socketed ends centrifugally cast (spun cast) class LA suitable for run leads joints including taking out old water linescomplete all as specified and directed by Engineer-in-Charge for the following size:- Note:- Earth work, Joints and CI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item.
100 mm bore.
80 mm bore.
Supply and fixing cast iron specials/fittings such as bend, tee, socket, collar Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipe upto 150 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, jointing and testing in replacement of ISI Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe including taking out old gate valve complete all as specified and directed for following bore of pipes:-
50 mm bore.
40 mm bore.
25 mm bore.
20 mm bore.
15 mm bore.
Supply, installation, fixing, jointing and testing in replacement ISI Marked, of approved quality, cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, long body type, including taking out old sluice valve complete all as specified and directed for following bores :-
100mm bore.
80mm bore.
Supply and fixing in replacement ISI Marked, of approved quality, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed for 80 mm bore sizes including taking out old non return valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, of approved quality, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed for100 mm bore sizes including taking out old non return valve complete all as specified and directed.
M&L for run lead joints in replacement including caulking properly and old lead retrieved shall be incorporated in same joint for the following sizes of CI pipes/fittings etc. complete all as specified and directed.
100mm bore.
80mm bore.
M&L for rubber gasket joints in flanged end cast iron pipes and fittings complete with and including minimum 3mm thick rubber/fibre gasket and necessary nuts/bolts/washers complete all as specified and directed for following sizes:-
100mm bore.
80mm bore.
M&L for rectifying leakage of CI pipe line including excavation in mud (not exc 1.2m x1.2m x 1.2m) and making arrangement for dewatering by using electric/diesel pump/manual additional labour, taking out existing joint and making new run lead joint (except CI fittings unions and CI pipes) complete all as directed for following size of pipe lines:-
100mm bore.
80mm bore.
M&L for rectifying leakage of 50mm GI pipe line including excavation in mud (not exc 0.7m x 0.7m x 0.7m) and making arrangement for dewatering by using electric/diesel pump/manual additional labour, taking out existing joint and making joint including providing all GI fittings i.e. socket, tee, elbow , nipples upto 6'' length,GI unions,Reducer (Except GI pipes) complete all as directed.
Supply only Calcium based, high strength chlorination chemical for water disinfectant in granular form in factory sealed HDPE container (45/50 Kg each ) , chlorine concentration leve 70% and delivered at various water installation underAGE E/M (AF) Palam complete all as specified and as directed. ( Make :" ALTOCH-GP" of Declibac or equivalent make as approved by GE)
M&L in replacement of rotational moulded polyethylene water storage tanks 3 layer (cylindrical vertical with closed top) hoisted and fixed in position of capacity 2000 to 3000 ltrs including gasket packing ,nipple of upto 50 mm dia, check nuts etc complete all as requried for connecting the existing position and including painting complete all as specified and directed by Engr in charge.
M&L for two coat Synthetic paint over coat of redoxide to exposed CI/GI water pipe lines of header/suction /delivery of borewells/booster pumps any type any make and any size including sluice valves,fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writting /marking complete all as specified and directed .
M&L for Painting to electrical equipments steel sections, rolling shutters etc with two coat of synthetic enamel high glow paint Ist grade Over one coat of redoxide including preparation/cleaning of steel surfaces complete all as specified and as directed by Engr-in-charge.
M&L for construction of valve chambers with MS cover 6 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thick PCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in CM 1:4, and angle iron frame 40x40x6 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of red oxide primer after preparation of surface complete all as specified and as shown in drawing No CE(AF)/TD/30 dated 11.11.2013 including dismantling of existing valve pit.
M&L for construction of valve chambers with MS cover 6 mm thick of valve pit of size 900x900x900 MM( internal dimensions) including necessary excavation, earth work 150 mm thick PCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in CM 1:4, and angle iron frame 40x40x6 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of red oxide primer after preparation of surface complete all as specified and as shown in drawing No CE(AF)/TD/30 dated 11.11.2013 including dismantling of existing valve pit.
Lifting / taking out the defective submersible pump motor set of any capacity and description / make, at any depth from bore well by lifting tolls , chain pulley etc all as required carefully, by disconnecting / dismantling all electric connections, column pipes of any size 50/80 mm etc and transporting the defective pump motor set to AGE E/M Yard, lowering the new / serviceable submersible pump motor set to the existing location including replacing the rubber packing/ nut bolts of the column pipes , pipes, valves etc of suitable size where ever required complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing of submersible electric driven pump only with outer dia of pump not exceeding 150 mm having discharge capacity 5 lps at upto 100 Meter head (operating head range -113-74 mtr) complete all as specified and directed by Engr-in-charge. (Taking out and lowering of pump motor set will be measured and paid separately) Note : Taking out Old unsv Material Pump deposit to MES Store yard.
Supply, fixing, connecting electric connections and testing submersible motor only capacity upto 10 HP(as per existing sample) 3 phase 415 volts, 50 HZ with outer dia of pump set not exceeding 150 mm suitable to be coupled with pump as mentioned in item no. 26 hereinbefore complete all specified and directed.(Taking out and lowering of pump motor set will be measured and paid separately). Note : Taking out Old unsv Material Motor deposit to MES Store yard.
S&F 150 ltr capacity PVC tank ISI Marked triple layer,including fitting and fixture complete all as specified and directed by Engr-in-Charge.
S&F in replacement connection and testing of submersible cable copper conductor 3 core 1100 Volt grade 4 sq mm nominal cross sectional area including disconnecting the old u/s cable complete all as specified and directed by Engr-in-charge.
Supply only Jal-TARA Water Testing Kit, the kit can be 16 essential parameters. The Jal TARA Test kit Carry over to Physical :parameters,pH,Hardness,Temperature,Turbidity and TDS Chemical : Arsenic, Choride, Fluoride, Iron,Nitrate,Residual Chlorine,Disssolved Oxygen, Phosphorus and Ammonia Biological : Coliform Bacteiria, Benthic Diversity.
M&L for high pressure single electromagnetic diaphragm type adjustable chemical dozing pump capacity 6 to 10 LPH 230V 50Hz as per existing sample at 3 Kg/cm² suitable to doze the NaOCL with accessories including heavy duty Lead Tubing of suitable size , Connecting Nuts, Injection Check Valve, Clay Weight, and connecting Ferrules with mounting arrangement and complete with foot valve, Non return valve, suction piping and Delivery piping complete all as specified and directed by Engr-in-charge including disconnecting the old one of any type any capacity. Make:- E Dose/ Milton Roy / Sandur Fliud
Annual maintenance contract visit for 09 months of RO Plant Capacity 450 Ltr/hr, at 27 ED technical area including servicing, overhauling & repair if any required with replacement of all unserviceable parts complete all as specified and as directed by Engineer-in-charge. Note:- The RO Plant maintained in serviceable condition through out the contract period and any complaint regarding unserviceability of shall be rectified within 48 Hrs. After 48 Hrs panelty @ Rs 2000/ day shall be deducted from contractors dues till rectification of complaint.
(A) Comprehensive AMC for RO Plant & its Equipment Capacity 450 Ltr/hr :- (i) MGF -01 No (ii) Dosing Pump -01 (iii) RO Plant Complete 450 ltr/hr -01 (B) scope to be covered under AMC :- (i) Provision of training to oprate the above System (ii) Submission of the preventive Maintenance Chart for the Month (iii) Cleaning operation for RO Membrane with all consumable/Chemicals (Note : Every month should carried out Membrane servicing with chemicals) (iv) Every Month visit by the RO Technician and replacement of Cartidge, the supplier will arrange the same and TDS maintain the RO Should be 100 to 120 as per user requirement (v) Arrangment for probing of RO inter stage once in a month, resetting of 'O' ring inboard connector etc to be arranged, if Required (vi) Maintenance/trouble shooting of high pressure pump Necessary spares will be arranged by Suppliers,if Required (vii) Fault detection procon Pump/high prssure pump (h) Replacement of on off switches
(viii) PVC interconnection pipe line of complete RO system (excluding incoming GI pipe line) (ix) Interconnector of Pressure vessel & 'O' ring of connector (x) Mechanical seal of high Pressure pump (xi) Pressure switches (xii) Rota meter suitable for re-circulation line (xiii) ball valve size 1'' SS 316 & victaulic coupling 1 1/2'' (ix) pressure gauge SS 0-7 to 21 kg/sqcm (x) U pvc pipes size as per existing sample including aceessories (tee,elbow,socket etc).if any damages replace that items. (xi) The above items shoud be covered AMC Total overall serviceable RO Plant Through contract period.No Extra amount shall be paid govt in this account. II. Providing following material for the purpose of AMC for 11 months :- (a) Micron catridges -10 Nos (b) De- scaling chemical- 30 Kg (c) Defouling chemical- 30 Kg (d) Anti scalent-36 Kg (e) Soda Ash - 20 Kg (f) Cleaning chemical HCL - 20 Ltr (g) Chlorine-15 Kg
Annual maintenance contract for 09 months of RO Plant Capacity 250 Ltr/hr, at 31 MCU technical area including servicing, overhauling & repair if any required with replacement of all unserviceable parts complete all as specified and as directed by Engineer-in-charge. Note:- The RO Plant maintained in serviceable condition through out the contract period and any complaint regarding unserviceability of shall be rectified within 48 Hrs. After 48 Hrs panelty @ Rs 2000/ day shall be deducted from contractors dues till rectification of complaint.
(A) Comprehensive AMC for RO Plant & its Equipment Capacity 450 Ltr/hr :- (i) MGF -01 No (ii) Dosing Pump -01 (iii) RO Plant Complete 450 ltr/hr -01 (B) scope to be covered under AMC :- (i) Provision of training to oprate the above System (ii) Submission of the preventive Maintenance Chart for the Month (iii) Cleaning operation for RO Membrane with all consumable/Chemicals (Note : Every month should carried out Membrane servicing with chemicals) (iv) Every Month visit by the RO Technician and replacement of Cartidge, the supplier will arrange the same and TDS maintain the RO Should be 100 to 120 as per user requirement (v) Arrangment for probing of RO inter stage once in a month, resetting of 'O' ring inboard connector etc to be arranged, if Required (vi) Maintenance/trouble shooting of high pressure pump Necessary spares will be arranged by Suppliers,if Required (vii) Fault detection procon Pump/high prssure pump (h) Replacement of on off switches (viii) PVC interconnection pipe line of complete RO system (excluding incoming GI pipe line) (ix) Interconnector of Pressure vessel & 'O' ring of connector (x) Mechanical seal of high Pressure pump (xi) Pressure switches (xii) Rota meter suitable for re-circulation line (xiii) ball valve size 1'' SS 316 & victaulic coupling 1 1/2''
(ix) pressure gauge SS 0-7 to 21 kg/sqcm (x) U pvc pipes size as per existing sample including aceessories (tee,elbow,socket etc).if any damages replace that items. (xi) The above items shoud be covered AMC Total overall serviceable RO Plant Through contract period.No Extra amount shall be paid govt in this account. II. Providing following material for the purpose of AMC for 11 months :- (a) Micron catridges -10 Nos (b) De- scaling chemical- 30 Kg (c) Defouling chemical- 30 Kg (d) Anti scalent-36 Kg (e) Soda Ash - 20 Kg (f) Cleaning chemical HCL - 20 Ltr (g) Chlorine-15 Kg
(h) Replacement of On/ Off switches. (j)PVC interconnection pipe line of complete RO system (excluding incoming GI pipe line) (k) interconnector of Pressure vessal & 'O' ring connector (l) Mechanical seal of high pressure pump. (m) Pressure switches. II. Providing following material for the purpose of AMC for 11 months :- (a) Micron catridges -10 Nos (b) De- scaling chemical- 30 Kg (c) Defouling chemical- 30 Kg (d) Anti scalent-30 Kg (e) Soda Ash - 20 Kg (f) Cleaning chemical HCL - 20 Ltr (g) Chlorine - 15 Kg
Supply only replacement of membrane suitable for 450/250 LPH model -4040 (as per sample) complete all as specified and as directed.
Supply and fix replacement of cartage housing suitable for filter 20''x4'' suitable for RO capacity 450/250 LPH including gasket packing etc (as per sample) and including cartage housing locking & unlock tool complete all as specified and as directed.
Material and Labour replacement of MGF capacity 450/250 LPH suitable for as per sample and including multiport valve connecting accessories as per existing PVC pipe line complete all as specified and directed.
Material and Labour replacement of media for MGF suitable for RO plant inluding taking out old media and gasket complete all as specified and as directed.
Notes:- (a) The amount of Rs. 68, 368/- against Schedule of Credit on Page No. 120R & 121R shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) As contract is maintenance nature the site shall be handed over in pieces as per site availability from users. (c) Contractor/ contractor rep shall take complaint from MES comlaint cell on every day and these complaints shall be rectified with in 48 Hrs. As water supply/sewage system is of vital nature, If any complaint/ work is not completed with in 48 Hrs that can be get executed from any other agency and cost of the same shall be deducted from contractor's dues.
Sumit Enterprises
Ridhi engineers and builders
M/S Anand Enterprises
Surjit and Sons
Deep Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .