Engine Division, Koraput
HINDUSTAN AERONAUTICS LIMITED Engine Division, Koraput, Sunabeda- 763002
CONSTRUCTION OF EXTENSION BUILDING OF HASC GYMNASIUM INSIDE HAL TOWNSHIP
6887
ETN NO W-51/23-24
Works
Mig Complex- Engine Divn-Koraput-Civil
₹1,120
₹8,920
18 Apr 2024
3 Apr 2024
3 Apr 2024
18 Apr 2024
CIVIL WORKS (ANNEXURE-A)
ANNEXURE-A1
CONSTRUCTION OF STANDBY WATER RESERVOIR AT R ZONE
Labour charge for Earthwork excavation either straight or curved on plan in all kind of soil for any kind of foundation including for trenches, pits, tunnels and over areas etc; for the following depth below average ground level including shoring, planking and strutting for protecting the sides of foundation, pumping, bailing out of water so as to keep foundations in dry conditions at any stage of work and drain the water away from the site of work for levelling and ramming the bottom of excavation,Clearing away all grass, vegetation, sapling,shrubs, bushes etc from the site prior to starting of excavation work; all complete as per specfifications and direction of Engineer-In-Charge.
Earth work excavation in Hard/dense soil in trenches for any kind of foundation including for trenches ,shaft,manholes etc for the following depths below average ground level including shoring,planking , strutting for protecting the sides of foundation, pumping , baling of water so as to keep foundations in dry conditions at any stage of work and drain the water away from the site of work levelling , well ramming the bottom of excavation and all complete as per specification an d direction of Engineer - in - charge.
Supplying, carrying to site all approved quality clean river sand, filling under floors, foundations or any other places including, leveling, watering and consolidating etc; all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying required thickness of PCC (1:4:8) of nominal mix using 40 mm and down hard granite graded hard stone aggregate for levelling course in foundation at any depth including for trenches, pits and tunnels in under floors, mass concrete and other similar works at all levels and heights elevations including mechanical mixing transporting and placing at all lifts, vibrating, compacting , levelling , curing , dewatering , whereever necessary etc all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying required thickness of PCC (1:2:4) of nominal mix using 40 mm and down hard granite graded hard stone aggregate for levelling course in foundation at any depth including for trenches, pits and tunnels in under floors, mass concrete and other similar works at all levels and heights elevations including mechanical mixing transporting and placing at all lifts, vibrating, compacting , levelling , curing , dewatering , whereever necessary etc. all complete as per specification and direction of Engineer - in - charge.
Supplying Carrying to site all approved materials,providing and laying Reinforced Cement Concrete (Design Mix) M30 Grade using 20 mm graded aggregates for water retaining structures,water tanks etc.for the following RCC structures excluding the cost of providing,shuttering, centering and scaffolding and the cost of steel reinforcement ,which will be measured and paid separately but including mechanical mixing, transporting and placing at all lifts/ leads, vibrating, compacting, levelling, dewatering, curing, finishing etc.The work also includes adding/ mixing of integral water proofing liquid admixture for concrete ,at the time of making concrete as per the manufacturer instruction.The dosage of integral waterproofing liquid compound shall be as per the quantity recommended by the manufacturers and the material shall conforms to IS 2645-2003 and IS 9103-1989.The make of the liquid waterproofing compound shall be from reputed manufacturers i.e: Fosroc, Sika, BASF Pidilite (Dr.Fixit), or equivalent etc complete as per specifications and direction of Engineer-in-Charge.
Supplying Carrying to site all approved materials,providing and laying Reinforced Cement Concrete (Design Mix) M20 Grade using 20 mm graded aggregates for walls, retaining walls,basement walls and the like ,any thickness etc. water retaining structures,water tanks etc.for the following RCC structures excluding the cost of providing,shuttering, centering and scaffolding and the cost of steel reinforcement ,which will be measured and paid separately but including mechanical mixing, transporting and placing at all lifts/ leads, vibrating, compacting, levelling, dewatering, curing, finishing etc. complete as per specifications and direction of Engineer-in-Charge.
Supplying carrying to site all approved materials providing & fixing in position Mild Steel reinforcement bars (TMT bars) conforming to IS 432, cut to length, bent to shape required including cranking, bending spirally for hooping and binding with mild steel wire (annealed) not less than 0.9 m dia for securing with clips. The rate to includes cost of binding wire, cement cover blocks, all cuts and wastes which will not be measured. Only laid weight will be measured including authoirized lapse etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and fixing in position safe , rigid and smooth Centering and Shuttering to all faces of all RCC works using necessary shuttering / centering materials like ply boards, steel shuttering plates, ballahs, planks etc.with finished surface as may be required with all necessary supports, struts, braces, wedges and other suitable arrangements to support the form work with all necessary fastening materials such as nuts, bolts, nails, steel wire, clamps, providing scaffoldings, ladders, making the form work leak proof, removal of form work after required period to obtain a finished surface ,clearing the site etc. all complete as per specifications and directions of Engineer-in -Charge.
Labour charge for returning, filling of excavated earth in the trench side gaps of foundation, sides of laid pipe line or any other places including spreading, levelling,watering and well ramming in layers not exceeding 25cm etc: all complete as per standard specifications as directed by the Engineer-in-Charge.
Supplying, carrying to site all approved materials and providing cement plastering in CM (1:4) , The work also includes adding / mixing of integral water proofing liquid admixture for cement mortar at the time of making mortar as per the manufacturer instruction.The dosage of integral waterproofing liquid compound shall be as per the quantity recommended by the manufacturers and the material shall conforms to IS 2645-2003 and IS 9103-1989.The make of the liquid waterproofing compound shall be from reputed manufacturers i.e:Fosroc, Sika, BASF Pidilite (Dr.Fixit),or equivalent etc.The works shall be taken up in all heights with erection of necessary safe and rigid scaffolding including rendering, floating, finishing the surface even and neat, curing etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying, carrying to site all approved materials and providing Screed bed or bedding layer of mortar 20 mm avg. thick over the exterior surface of roof/dome for laying floor finishes in cement mortar (1:4) The work also includes adding/ mixing of integral water proofing liquid admixture for cement mortar ,at the time of making mortar as per the manufacturer instruction.The dosage of integral waterproofing liquid compound shall be as per the quantity recommended by the manufacturers and the material shall conforms to IS 2645-2003 and IS 9103-1989.The make of the liquid waterproofing compound shall be from reputed manufacturers i.e:Fosroc, Sika, BASF Pidilite(Dr.Fixit), or equivalent etc,The works shall be taken up in all heights with erection of necessary safe and rigid scaffolding including rendering, floating, finishing the surface even and neat, curing etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying, carrying to site all approved materials and providing 10 mm thick cement plastering in CM (1:4) in all heights with erection of necessary safe and rigid scaffolding including rendering, floating, finishing the surface even and neat, curing etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying, carrying to site all approved materials and providing two coats of premium Acrylic smooth exterior paint with Silicone additives of required shade:New work (Two or more coat applied @ 1.43 Ltr/10Sqm over and including priming coat of exterior primer applid @ 2.20 Kg/10Sqm) (weather coat) with preparation of surface. The work also includes provision of necessary scaffolding etc. all complete as per direction of Engineer in charge.
Supplying, carrying to site all approved materials, providing and painting with Two coats of High gloss Synthetic Enamel Paint (Class – 1 / Grade – 1) confirming to latest edition of IS 2932 of approved make/ shade over a coat of Red oxide / Zinc chrome primer on Steel surfaces at all heights neatly without brush mark. The work shall include preparation of the surfaces by using sand/ emery papers, cleaning, removal of the scales, peeled surfaces, filling the pits/ depressions, nail – holes, knots etc. by putty and applying paint by using brush/ spray to get uniform finish without any patches including erection of safe/ rigid scaffoldings, cleaning the area after painting etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying carrying to site all approved material, Providing and applying,finishing with Epoxy paint (two or more coats) at all locations to the steel surface , prepared and applied as per manufacturer's specifications including application of one coat of appropriate priming coat, preparation of surface, etc. complete.as per specification and direction of EIC
Supplying carrying to site all approved materials and application of Two coats of Food grade Epoxy resin based protective coatings conforming to IS 9833-1981,solvent free, epoxy resin coatings for potable water retaining structures/water tanks, prior to application of the paints all the blow holes and imperfections should be filled with the required epoxy mortar. or as per product specification.The consumption of materials shall be as per the products specification for smooth surface finish etc.Make: Fosroc-Nitocote EP 405,Sika guard 67 or relevent products from BASF,Dr.fixit or equivalent brands from reputed manufacturers.The work also includes Surface preparation.
Supplying & carrying to site all approved materials providing and fixing framed work such as grill, gratings, using standard section of MS angles, channels, flats, plates etc. with ends of bars soldered and / or rivetted, or forged into spikes and guard bars, barred iron doors, ladders, framed balusters, walkways, railings, frame work of water tanks and similar work conforming to Fe 290. Gde-E-165 etc.all complete as per standard specifications as directed by the Engineer-in-charge
Supplying & carrying to site all approved materials providing and fixing 50mm dia medium duty GI pipe ISI marked for fixing on floors/slabs etc. with necessary welding/fittings as per site requirement.etc.all complete as per standard specifications as directed by the Engineer-in-charge.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Supplying, carrying to site all approved materials providing and fixing Double Flanged (Screwed/Wlded) 350mm dia Centrifugally cast (spun) ductile Iron pressure pipes of classification K-9 class, conforming to IS 8329. The work includes lowering, laying and jointing of DI pipe with rubber gasket in proper position, grade and alignment including conveyence of material to site of work, unloading , hydraullic testing etc. Make:- M/s Electro Steel casting Ltd; M/s Rashmi Metallics Ltd; M/s TATA Metallics LTD; M/s Electrotherm (India) Ltd; M/s Jindal Saw Ltd; Sri Kalahasti Pipes Ltd/LANCO. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing Double Flanged (Screwed/Wlded) 300mm dia Centrifugally cast (spun) ductile Iron pressure pipes of classification K-9 class, conforming to IS 8329. The work includes lowering, laying and jointing of DI pipe with rubber gasket in proper position, grade and alignment including conveyence of material to site of work, unloading , hydraullic testing etc. Make:- M/s Electro Steel casting Ltd; M/s Rashmi Metallics Ltd; M/s TATA Metallics LTD; M/s Electrotherm (India) Ltd; M/s Jindal Saw Ltd; Sri Kalahasti Pipes Ltd/LANCO. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : Centrifugally cast (spun) ductile Iron pressure pipes with socket and spigot for classification K-9 class with inside cement mortar lining and out side zinc coating with finishing layer of bituminous coating, conforming to IS 8329 with suitable push on rubber gasket joint of EPDM quality. The work includes lowering, laying and jointing of DI pipe with rubber gasket in proper position, grade and alignment including conveyence of material to site of work, unloading , hydraullic testing etc. Make:- M/s Electro Steel casting Ltd; M/s Rashmi Metallics Ltd; M/s TATA Metallics LTD; M/s Electrotherm (India) Ltd; M/s Jindal Saw Ltd; Sri Kalahasti Pipes Ltd/LANCO. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing in position MS ERW pipes 350 mm dia conforming to IS 3589/2001 of size 350mm dia and thickness of 8mm ,all the joints,weldings are to be tested properly with required water pressure,including transportation of material to site laying in proper position, grade and alignment, hydraullic testing provision of necessary scaffoldings and welding at site with necessary fittings likes tees, bends, flanges etc.... All complete as per specification & direction of EIC.
Labour charges for cutting of existing MS/CI pipes using necessary tools and tackles,gas cutter etc.The contractor has to arrange all the necessary assosories/Consumables at no extra cost etc. All complete as per specification & direction of EIC.
Labour charges for Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting oflead and making into blocks, including stacking of pipes at site lead up to 50 metre:using necessary tools and tackles,gas cutter etc.The contractor has to arrange all the necessary accesories/Consumables at no extra cost etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing in position 350 mm dia DI Mechanical joint and fixing with nuts and bolts / gaskets etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing 350mm size MS flange of thickness 20mm with nut and bolts and gaskets for jointing etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing in position 350mm size MS long pipe bend (plane bevelled end) of ISS ERW 90 Degree, "C" class. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing in position CI rising spindle sluice Valve Flanged end as per IS: 14846, pressure rating PN16 of 350 mm dia Body,Cover-CIIS:210,Gr.FG260 Door-CI IS :210,Gr.FG260 Body Ring-Bronze IS:318 Gr.LTB2 Door Face-Natural Rubber Hinge Pin-SS ASTM A276 Type 410 Fasteners-CS IS:1367,CL-4.6/4.0 Gasket-Natural Rubber Flange Drilling-IS:1538,Table 4&6, pressure rating PN16 of 350 mm dia fixed with necessary nuts and bolts / gaskets as per requirement at site etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials providing and fixing in position CI rising spindle sluice Valve Flanged end as per IS: 14846 ,pressure rating PN16 of 300 mm dia Body,Cover-CI IS:210,Gr.FG260 Door-CI IS :210,Gr.FG260 Body Ring-Bronze IS:318 Gr.LTB2 Door Face-Natural Rubber Hinge Pin-SS ASTM A276 Type 410 Fasteners-CS IS:1367,CL-4.6/4.0 Gasket-Natural Rubber Flange Drilling-IS:1538,Table 4&6,pressure rating PN16 of 300 mm dia fixed with necessary nuts and bolts / gaskets as per requirement at site etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all approved materials Providing and fixing C.I. double acting air valve 100 mm dia of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :fixed with necessary nuts and bolts / gaskets as per requirement at site etc. All complete as per specification & direction of EIC.
Supplying, providing and installation of water meter of size 350mm, bulk type, Design : Woltman removable mechanism class B as per ISO 4064 ,Mounting "flanged ends, Cold Water Flow meter MOC body-cast iron,temp-max 45 degrees C',dry dial magnetic driven flanged ends,provide resistance against condensation hermetically sealed copper casing as per IP68. etc. All complete as per specification & direction of EIC.
Supplying, providing and installation of Level Indicator with Float and Board type Level Gauge For Tank Height up to 10.00 Meter ,Gauge board:Aluminium powdered coated,Float:diameter 300mm S.S 316, Wire:S.S. 316,Flange: 1" asa 150#M.S.powder coated ,Pulley:PP, Pulley encloser : M.S.powder coated, Telescopic pipe:500mm M.S.powder coated, Pointer: traingular M.S,powder coated, Density:>=0.8g/cm3,max.Temp:100'C,Max.Pressure:Atm etc. All complete as per specification & direction of EIC.
Supplying, carrying to site all materials, providing lead caulked joints with molten lead in C.I. Pipes/specials of all classes by using caulking pig lead confirming to IS 782-1978. The jointing is to be done by properly / correctly positioning of the socket / spigot end in the adjoining socket of the C.I. line by tightly caulked in sufficient turns of tored gasket or spun/hemp yarn so as to leave half of the depth of socket for lead. The joint runner shall fit snugly against the face of the socket and the outside of the pipe shall be dammed with clay to form a pouringlip to provide for filling joint.
The lead shall be heated to the proper temperature, all scum to be removed and continuously poured lead into the joint in one pouring. The pipe joint should be dry before pouring the lead so that blow holes may not occur in the joint. The lead joint then be solidly caulked with suitable tolls, hammers of not less than 3 kg weight around the barrel of the pipe so as to make the cooled lead to shrink 3mm behind the socket face etc,all complete as per specification and direction of Engineer-in-charge. The pipe joints are to be tested to withstand hydraulic test pressure as specified for leak proofness for at least minimum period of 2 hours.all complete as per the specifications and direction of Engineer in Charge.
Supplying, carrying to site all approved materials providing and fixing in position Ductile Iron K - 12 specials suitable for push on jointing up to 600 mm dia etc. All complete as per specification & direction of EIC
Supplying, carrying to site all approved materials providing and fixing in position Ductile Iron specials suitable for mechanical jointing as per I.S. 9523 - up to 600 mm dia etc. All complete as per specification & direction of EIC
Supplying, carrying to site all approved materials providing and fixing in position Rubber gasket conforming to IS 5382 of SBR quality in joint portion of 300mm dia CI pipes etc. All complete as per specification & direction of EIC
Supplying, carrying to site all approved materials providing and fixing in position Rubber gasket conforming to IS 5382 of SBR quality in joint portion of 350mm dia CI pipes etc. All complete as per specification & direction of EIC
Supplying, carrying to site all approved materials providing and fixing in position CI Puddle colar of 350mm dia conforming to IS 1538 and fixing with nuts and bolts etc. All complete as per specification & direction of EIC
SUB TOTAL ANNEXURE-A1
ANNEXURE-A2
PERIPHERIAL DEVELOPMENT FOR APPROACH TO RESERVOIR ROAD
Earthwork excavation in hard & dense soil in over areas not exceeding 1.50 meter depth below average ground level and getting out the same.The bed of excavation shall be formed to the required level, slope or grade and shall be made firm by watering and remming etc. all complete as per specifications and directions of Engineer-in-charge.
Removing excavated materials i.e hard/ dense soil to the earmarked low lying areas within a lead not exceeding 50m and depositing where directed etc. all complete as per specification & direction of Engineer-In-charge.
Supplying, carrying to site all approved quality clean river sand, filling under floors, foundations or any other places including, leveling, watering and consolidating etc; all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying required thickness of PCC (1:4:8) of nominal mix using 40 mm and down hard granite graded hard stone aggregate for levelling course in foundation at any depth including for trenches, pits and tunnels in under floors, mass concrete and other similar works at all levels and heights elevations including mechanical mixing transporting and placing at all lifts, vibrating, compacting , levelling , curing , dewatering , whereever necessary etc all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying RCC M20 Grade using 20 mm aggregates (Design Mix) excluding the cost of providing, centering and scaffolding and the cost of steel reinforcement which will be measured and paid separately but including mechanical mixing, trasporting and placing at all lifts/ leads, vibrating, compacting, levelling, dewatering, curing, finishing fair etc.complete as per specifications and direction of Engineer-in-Charge.
Supplying carrying to site all approved materials providing & fixing in position Mild Steel reinforcement bars (TMT bars) 10mm dia and over conforming to IS 432, cut to length, bent to shape required including cranking, bending spirally for hooping and binding with mild steel wire (annealed) not less than 0.9 m dia for securing with clips. The rate to includes cost of binding wire, cement cover blocks, all cuts and wastes which will not be measured. Only laid weight will be measured including authoirized lapse etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and fixing in position safe , rigid and smooth Centering and Shuttering to all faces of all RCC works using necessary shuttering / centering materials like ply boards, steel shuttering plates, ballahs, planks etc.with finished surface as may be required with all necessary supports, struts, braces, wedges and other suitable arrangements to support the form work with all necessary fastening materials such as nuts, bolts, nails, steel wire, clamps, providing scaffoldings, ladders, making the form work leak proof, removal of form work after required period to obtain a finished surface ,clearing the site etc. all complete as per specifications and directions of Engineer-in -Charge.
Supplying and carrying to site all approved materials, providing and constructing Random rubble masonry work, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:4) of required thickness for walls or any other places in all heights using approved quality stone with straight or curved, with erection of safe / rigid scaffolding and curing etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials and providing 15 mm thick cement plastering in CM (1:4) on stone masonry surfaces .The work also includes finishing the surface smooth, fair and even including erection of necessary scaffolding and curing etc. all complete as per specifications and directions of Engineer-in-charge.
SUB TOTAL ANNEXURE-A2
ANNEXURE-A3
CONSTRUCTION OF SECURITY WATCH TOWER NEAR TO THE WATER RESERVOIR
Earth work excavation in Hard/dense soil in trenches for any kind of foundation including for trenches ,shaft,manholes etc for the following depths below average ground level including shoring,planking , strutting for protecting the sides of foundation, pumping , baling of water so as to keep foundations in dry conditions at any stage of work and drain the water away from the site of work levelling , well ramming the bottom of excavation and all complete as per specification and direction of Engineer - in - charge.
Labour charge for returning, filling of excavated earth in the trench side gaps of foundation,sides of laid pipe line or any other places including spreading, levelling,watering and well ramming in layers not exceeding 25cm etc: all complete as per standard specifications as directed by the Engineer-in-Charge.
Supplying, carrying to site all approved quality clean river sand, filling under floors, foundations or any other places including, leveling, watering and consolidating etc; all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying required thickness of PCC (1:4:8) of nominal mix using 40 mm and down hard granite graded hard stone aggregate for levelling course in foundation at any depth including for trenches, pits and tunnels in under floors, mass concrete and other similar works at all levels and heights elevations including mechanical mixing transporting and placing at all lifts, vibrating, compacting , levelling , curing , dewatering , whereever necessary etc all complete as per specification and direction of Engineer - in - charge.
Supplying, carrying to site all approved materials, providing and laying of RCC M20 Grade Design Mix using 20 mm aggregates excluding the cost of providing, centering and scaffolding and the cost of steel reinforcement,which will be measured and paid separately but including mechanical mixing, trasporting and placing at all lifts/ leads, vibrating, compacting, levelling, dewatering, curing, finishing etc.complete as per specifications and direction of Engineer-in-Charge.
Supplying, carrying to site all approved materials, providing and fixing in position safe , rigid and smooth Centering and Shuttering to all faces of all RCC works using necessary shuttering / centering materials like ply boards, steel shuttering plates, ballahs, planks etc.with finished surface as may be required with all necessary supports, struts, braces, wedges and other suitable arrangements to support the form work with all necessary fastening materials such as nuts, bolts, nails, steel wire, clamps, providing scaffoldings, ladders, making the form work leak proof, removal of form work after required period to obtain a finished surface ,clearing the site etc. all complete as per specifications and directions of Engineer-in -Charge.
Supplying , carrying to site all approved materials , providing and fixing in position mild steel plain, black sheet of 0.80 mm thick in door shutters; covering to door chowkats (frames) , cut to size, edges beaded if directed , hole punched including round headed screws, clount nails or rivets and fixed to wood or steel member etc with plain 40 mm lap joints or welded / riveted seams including bending, turning up, mitred angles, stopped ends, outlets etc complete as per specifications and directions of Engineer - in - Charge .
Supply and laying of 50mm dia GI Pipes of medium grade with all fittings laid in floors or fix to walls .The necessary fabrication works like welding,bolting and fixing of the pipes with anchor fastners etc shall be done as per site requirement.
Supply and laying of 32mm dia GI Pipes of medium grade with all fittings laid in floors or fix to walls .The necessary fabrication works like welding,bolting and fixing of the pipes with anchor fastners etc shall be done as per site requirement.
Supplying carrying to site all approved materials providing & fixing in position Mild Steel reinforcement bars (TMT bars) conforming to IS 432, cut to length, bent to shape required including cranking, bending spirally for hooping and binding with mild steel wire (annealed) not less than 0.9 m dia for securing with clips. The rate to includes cost of binding wire, cement cover blocks, all cuts and wastes which will not be measured. Only laid weight will be measured including authoirized lapse etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying and carrying to site all approved materials, providing and constructing Brick masonry work of required thickness for walls or any other places in all heights using bricks (Class designation 50) of approved quality Fly Ash bricks in CM (1:4) with straight or curved, with erection of safe/ rigid scaffolding and curing etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and laying 40 mm thick cement concrete flooring (1:2:4) using 20 mm and down hard granite graded stone aggregates, laid to the required gradient, level, maintaining proper slope and well compacted, Including finishing the top surface neatly, evenly and smoothly and curing etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, and providing 15 mm thick Plastering in cement mortar (1:4) to the exterior surfaces of brick wall / concrete at all heights with erection of necessary scaffolding, including rendering ,floating, finishing the surface even and smooth, curing.etc. all complete as per specification and direction of Engineer-in-Charge.
Supplying, carrying to site all approved materials, and providing 10 mm thick Plastering in cement mortar (1:3) under the sides of slab and all other RCC surfaces including hacking preparation of surface etc at all heights with erection of necessary scaffolding, including rendering ,floating, finishing the surface even and smooth, curing.etc. all complete as per specification and direction of Engineer-in-Charge.
Supplying, carrying to site all approved materials and painting with Two coats of cement painting of approved make and colour ovar a coat of priming coat white colour water proof cement paint at all heights on the wall surface of any description. Cement paint shall confirm to I.S No. 5410 – 1969 and shall be prepared by adding equal volume of paint powder with water and the mix should be stirred to obtain a thick paste which shall be diluted further to a brushable consistency. The work shall also include preparation of surface by scraping with sand paper, removing completely peeled scales, dirts, dusts etc.,filling nail holes / cracks if any with lime putty /snowfilla and removal of oil and grease spots, mud and making the surface absoutely free from any spots, scales, funges etc. and painting uniformly with out any patches and brush marks including erection of safe scaffolding, cleaning / washing areas after painting etc and also include curing each coat of painted surface with water for minimum 2-3 days. etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved material and applying Three coats of white washing on wall at all height using approved quality shell lime mixed with blue and glue in suitable proportions (approx. 4 to 6 gms of blue and 30 gms of glue per Kg of lime). The work shall also include preparation of surface by scarping with wire brush/sand paper /removing dirt’s, dusts etc., filling nail holes/cracks if any with lime putty and snow fill or any other suitable materials and making the surface absolutely free from any spot, scales, fungus etc. Including erection of safe scaffolding if required, cleaning/washing areas after white washing etc. all complete as per specification and direction of the Engineer-in-Charge
Supplying, carrying to site all approved materials, providing and painting with Two coats of High gloss Synthetic Enamel Paint (Class – 1 / Grade – 1) confirming to latest edition of IS 2932 of approved make/ shade over a coat of Red oxide / Zinc chrome primer on Steel surfaces at all heights neatly without brush mark. The work shall include preparation of the surfaces by using sand/ emery papers, cleaning, removal of the scales, peeled surfaces, filling the pits/ depressions, nail – holes, knots etc. by putty and applying paint by using brush/ spray to get uniform finish without any patches including erection of safe/ rigid scaffoldings, cleaning the area after painting etc. all complete as per specifications and directions of Engineer-in-charge.
Labour charges for demolition of brick / stone boulder masonry built in cement mortar including disposal of debries to a lead 100 mtr etc. all complete as per specification and direction of Engineer-in-charge.
SUB TOTAL ANNEXURE-A3
SUB TOTAL CIVIL WORKS : ANNEXURE-A = ANNEXURE-(A1+A2+A3)
ANNEXURE-B
ELECTRICAL WORKS
Supply and laying of XLPE insulated, sheathed armoured U/G Cable with aluminium conductor 1100 volt grade make : Crystal / Havells /Universal/ Polycab / ISI approved. Laying of the above cable to be done in under ground at a depth of 750mm (approx) as per IE rules including supply of bricks and sand and in road crossing by punch hole of the road without damage of road as per requirement
Supply , Installation & commissioning of out door type Power distribution board made out of 2 mm thick CRCA sheet steel, dust vermin proof, free standing single front, single door and locking arrangement, busbar of 250 Amps current rating, DMC insulator as busbar support, painted with grey colour full body powder coating confirming to IP 65 . a) Incomming feeder : 250 Amps 415 volt 3 phase 50 Hz MCCB -with ammeter , volt meter, earth leakage, over load protection-1 set. b) Out going feeder : 125 Amps 415 volt, 3 phase , 50 Hz MCCB -6 nos. c) End termination of incoming & out going cable with glands nuts & bolts etc. d) Lifting of the cable to the terminal e) Earthing connection of the LT panel board. f) Make for incoming & out going MCCB - L & T, Hagger, Siemens, ABB, Scineider Installation and Commissioning of the panel to be done with making suitable concrete platform and necessary cable termination
Supply of Conduit Pipes
Wiring of circuit/ submain wiring along with earth wire with the following sizes of FR in PVC insulated copper conductor, single core cable in surface / recessed as required The rates for wiring includes for a) supplying & fixing/drawing of cables including connections b) Supplying & fixing all accessories such as screws, clips, plugs, clamps etc a specified for securing cables, conduits etc. to walls, steel joists etc. c) Supplying & fixing of bushed conduit or porcelien tubing for wiring to pass through walls, floors etc. d) Supplying & fixing of joint & junction boxes. e) Testing as specified
Supply and fixing of LED light fitting 1 x 22 watt , 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Point Wiring :
Supply and fixing of celing fan complete with blades, down rod, electronic regulator and acessories, 230 V , 1200 mm sweep. Min. Ari delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fixing exhaust fan, steel body AC single phase, 230 V of size 300 mm sweep with blades, frame and Louvers
Supply and fixing of sheet metal enclouser for DB's when MCBs to be used Triple pole and neutral 6 way double door DB
Supply and fixing of 415V 10KA 'C' curve miniature circuit breaker ( MCB) for following poles and current carrying capacity in the DB complete with connection testing and commissioning
Earthing complete with galvanised stel pipe electrode, 40 mm bore, medium grade, 2.5 mtrs length, buried directly and preferably vertically in ground with top edge not less than 1.25 mtrs below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire to the earthing test point including testing completion. The scope includes excavation and earth work, Required charcoal & salt , PCC pit & CI cover. funnel with watering pipe, wire mesh & copper lugs etc. as specified and connecting lead from test point to main switch or switch board or equipment to be earthed.
Street Light Poles and its Accessories
Supply and fixing of LED Flood Light luminaire complete with lamps and other accessories lens model capacity 120 watt, voltage 120 volt to 280 volt equipped with IP66 protection, with impact & corrosion resistant . Make of fitting - CG / Phillis / Bajaj / Havells/ Venture / Cema / Halonix / pyrotech'
Supply & installation of high mast Structure with LED luminary as per following specification. A. High Mast Structure i) Height: 16 Meters , ii) Metal protection treatment: Hot dip galvanized iii) No of sections: 2 , iv) Top Dia: 150mm (Min.), Bottom Dia: 460mm (Min.) v) Thickness: Top: 3mm, Bottom: 4mm vi) Wind load capacity: 50m/sec or better B) Luminary Carriage: i) No of fittings: 6 (each light fitting shall carry 02 nos of luminary) , ii) Light fittings shall be arranged symmetrically over 360 degrees C) Wire Rope: i) Grade: 304/316 grade SS , ii) Construction: 7/19 , iii) Dia: 6mm D) Cable : Multicore PVC insulated copper cable of suitable current carrying capacity.HSN CODE: 8544 E) Power Tools: Raising & towering system Power tool motor for raising & lowering the fittings (motorized and manual both) with double drum winch, wire rope and torque limiter etc. F) Luminary: HSN CODE: 9405 i) Type: LED flood light , ii) Capacity: 2 x 200W , iii) Ingress protection: IP66 or better , iv) Housing material: High pressure die cast aluminum/ extruded aluminium , v) CRI Index: 70 or more , vi) Colour temperature: 5700K to 6500K
G) Control: Outdoor type, stand mounted feeder pillar box, fabricated from CRCA steel sheet of thickness 2 mm for load bearing part and 1.5mm for non-load bearing part with following facilities to be provided: I-ISN ÇODE: 8536 i) 63 Amp of MCBs (TP and SP) along with 24 Hr programmable timer contactor with suitable provision for the automatic switching of luminaries at preset time ii) Starter control for power tool motor within the panel with Push buttons for forward & reverse operation of power tool. H) Aviation Light: Twin dome aviation obstruction lights with 2 nos. LED lamps or equivalent neon lamp for each pole. HSN CODE: 9405 l) Earthing & lighting arrester: HSN CODE: 8536 i) Provision of 2 nos. of GI pipe earthing as per IS 3043 including connection at both the ends through 25x3mm Gl flat. ii) Lightening arrester shall be fitted at the top of the mast and shall be connected to the earth pit. J) STANDARDS: The manufacturing and design of High mast lights shall comply with following standards: i) I.S. 875 (PART Ill) -1987: -Code and Practice for wind loads. ii) BS5649, PART-7: Structural Design iii) BSE-N 10025/10027, BS 4360: -Mast Sections iv) IS 2062: -Base plate, Top plate and Accessories v) BS 5135 or IS 9595: - Welding vi) BS 729 / IS 2629: -Galvanizing
ELECTRICAL WORKS : Sub Total Annexure-B
Sub Total Annexure (A+B)
ADD : GST @ 18% (( IGST18%) or (CGST @ 9% +SGST@ 9%)), Whichever is applicable
ADD : CESS @ 1%
GRAND TOTAL
SPECIAL CONDITIONS :
1. The agency has to do necessary soil testing and surveying of the area prior to starting of the work.
2. The strcutural drawing of water reservoir tank supplied by HAL are to be vetted by IIT's / IISC/ NIT's etc form Reputed Institutions prior to executions at site.
3. The expenditure to meet above conditionss at Sl-1 & 2 are to be borne by the agency, deemd to be included in his quote / bid
INSTRUCTION TO TENDERER
GOODS AND SERVICE TAX (GST)
Bidder should indicate GSTIN No. (Copy of GST registration to be enclosed) and PAN No. (copy of PAN to be enclosed).
Tender will be considered/ accepted, if & only if the vendor has a valid GST Registration No.
Central Tax/ State Tax/ Integrated Tax/ Union Territory tax to be quoted as per GST Law.
Bidders to ensure correct applicability of Central Tax/ State Tax/ Integrated Tax/ Union Territory tax based on the Inter / Intra state movement Supply of goods and provision services or both.
Bidder shall mention the SAC Code/HSN Code for goods and services in accordance with GST law in their Bid and subsequently in their tax invoice. HAL, Koraput Division shall not be responsible for any error in SAC Code/HSN Code for goods and/or services specified by supplier/contractor.
The Tax Invoice for supply of Goods & Services should be raised as per the provision of GST Act & Rules and must compulsorily mention the following.
a. HAL, Korpaut Division GST registration number as 21AAACH3641R1ZJ
b. Name & address of supplier / Vendor/ Contractors
c. GSTIN of Supplier / vendors / Contractors
d. Consecutive Serial Number & date of issue
e. Description of goods or services
f. Total value of supply
g. Taxable value of supply
h. Tax Rate – Central Tax & State Tax or Integrated Tax, Cess
i. Amount of Tax charged
j. Place of supply
k. Address of delivery if different from place of supply
l. Signature of authorized signatory
Reimbursement of GST to the vendor is contingent upon complying with the following condition by the service provider.
i. Uploading the (invoices raised on HAL, KoraputDivision ) onward GST Return (GSTR-1) in GSTN Network portal within the statutory time period.
ii. Discharging the GST tax liability to the Government.
iii. Submission of Tax Invoice to HAL, Korpaut Division.
iv. Submission of proof of payment of GST to HAL, Korpaut Division.
v. Receipt of goods / services by HAL Koraput Division.
vi. Availment of Input Tax Credit by HAL, Korpaut Division .
In case GST credit is delayed/ denied to HAL, Korpaut Division, due to non/delayed receipt of goods and/or services and/or tax invoice or expiry of timeline prescribed in GST Law for availing such ITC, or any other reason not attributable to HAL, Korpaut Division, GST amount shall be recoverable from Vendor along with interest & penalty levied/ leviable on HAL, Korpaut Division, as the case may be.
In case vendor delays declaring such invoice in his return and GST credit availed by HAL, Korpaut Division is denied or reversed subsequently as per GST law, GST amount paid by HAL, Korpaut Division towards such ITC reversal as per GST law shall be recoverable from vendor/contractor along with interest & penalty levied/ leviable on HAL, Korpaut Division.
In case of discrepancy in the data uploaded by supplier in the GSTN portal or in case of any incomplete work/service, then HAL, Korpaut Division will not be able to avail the tax credit and will notify the supplier of the same. Supplier has to rectify the data discrepancy in the GSTN portal or issue credit note (details to be uploaded in GSTN portal).
For any such delay in availing of tax credit for reasons attributable to vendor (as mentioned above), interest as per the GST Act & Rules, along with penalty, if any will be deducted for the delayed period i.e. from the month of receipt till the month tax credit is availed, from the running bills.
Penalty amount so determined along with GST if applicable thereon shall be recovered from the contractor.
Any reduction in rate of Tax on any supply of goods or services or the benefit of input tax credit shall be passed on to the recipient by way of commensurate reduction in prices. Bidders have to submit declaration in their bid that they have complied with ‘Anti-profiteering clause’ under GST law.
The bidder’s quoted rates/ price should be after considering the Input Credit under GST law at their end, since GST on output (GST amount charged in Invoice) will be paid by HAL.
In case any changes in taxes and duties as per Gov. Notification (including GST), the same shall be applicable from time to time.
Quarters will be allotted to the awarded agency subject to availability & recommendation from the E-I-C/ O-I-C for which rents as applicable will be recovered from the running bills of the agency.
APPENDIX-H
HINDUSTAN AERONAUTICS LIMITED
KORAPUT DIVISION
CENTRAL CONTRACT CELL
COMMERCIAL BID
BILL OF QUANTITIES FOR THE WORK OF "CONSTRUCTION OF EXTENSION BUILDING OF HASC GYMNASIUM INSIDE HAL TOWNSHIP"
LINE NO : KPTCC/W/302-2
NAME OF THE AGENCY :
Labour charges for Earthwork excavation in hard & dense soil for trenches, pits and tunnels etc. not exceeding 1.50 mtr wide and upto 1.50 meter depth below average ground level & getting out including shoring , shuttering for protecting the sides of foundation , pumping , baling of water so as to keep foundations in dry conditions at any stage of work and drain the water away from the site of work without any extra paymet for levelling, ramming the bottom of excavation etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing, filling, leveling, watering and consolidating with approved good quality river sand etc from approved quarry in layers of required thick in foundation of any depth including for trenches, pits and tunnels sides of foundation, under floor etc. including loading, transporting, uploading, all leads and lifts, labour etc.all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and laying required thickness of PCC (1:4:8) using 40 mm coarse graded hard stone aggregate for levelling course in foundation at any depth including for trenches, pits and tunnels in under floors, mass concrete and other similar works at all levels and heights, elevations including mechanical mixing, transporting and placing at all lifts, vibrating, compacting, levelling, curing, dewatering wherever necessary, the cost of all materials, labour, leads and lifts, tools and plant, machineries etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and laying RCC (1:1.5:3), Nominal mix using 20 mm graded aggregate for the following RCC structures excluding the cost of providing centering and scaffolding and the cost of steel reinforcement which will be measured and paid separately but including mechanical mixing, transporting and placing at all lifts / leads, vibrating, compacting, levelling, dewatering, curing, finishing fair etc. all complete as per specification and direction of Engineer-in-charge.
Supplying,carrying to site all approved materials providing and fixing in position MS bars (TMT bars) conforming to IS-432 / High yield strength deformed bars conforming to IS-1786 of Fe 415 Grade of all dia for reinforcement in all RCC in situ including flooring and precast works at all levels and for foundations, trenches, pits, tunnels, lift pits etc., below finished floor level including cost of supplying, straightening, cutting, bending to shape fabricating and tying with 18 gauge GI binding wire, providing and fixing cement cover blocks, dewatering wherever necessary etc. The rate to include cost of binding wire, cement cover blocks, all cuts and wastes which will not be measured. Only laid weight will be measured including authorised laps etc. all complete as per specification and direction of Engineer-in-charge..
Supplying, carrying to site all approved materials, providing and fixing in position safe , rigid and smooth Centering and Shuttering to all faces of all RCC works using necessary shuttering / centering materials like ply boards, steel shuttering plates, ballahs, planks etc. as may be required with all necessary supports, struts, braces, wedges and other suitable arrangements to support the form work with all necessary fastening materials such as nuts, bolts, nails, steel wire, clamps, providing scaffoldings, ladders, making the form work leak proof, removal of form work after required period to obtain a fair finished surface ,clearing the site etc. all complete as per specifications and directions of Engineer-in -Charge.
Supplying and carrying to site all approved materials, providing and constructing Brick masonry work of required thickness for walls or any other places in all heights using sub class "B" bricks (Class designation 50) of approved quality Fly Ash bricks in CM (1:4) with straight or curved, with erection of safe/ rigid scaffolding and curing etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, and providing 15 mm thick Plastering in cement mortar (1:4) to the exterior / interior surfaces of brick wall / concrete at all heights with erection of necessary scaffolding, including rendering ,floating, finishing the surface even and smooth, curing etc. all complete as per specification and direction of Engineer-in-Charge.
Supplying, carrying to site all approved materials, and providing 20 mm thick screed Plastering in cement mortar (1:4) with punning for laying floor finishes including rendering , floating, finishing the surface even and smooth, curing etc. all complete as per specification and direction of Engineer-in-Charge.
Supplying, carrying to site all approved materials, providing & fixing powder coated anodized aluminium frames & glazing clips as per approved design & drawing for doors, windows,partitions etc. with one or more rebates including jointing cleat, guide rollers.(The minimum thickness of powder coating 50 micron) etc. all complete as per specification & direction of Engineer-in-charge.
Supplying, carrying to site all approved materials and providing and fixing in position sheet glass, ordinary quality of 4.8mm thick, area not exceeding 0.50 sqm in each pane in the aluminium shutter, doors, windows etc. all complete as per specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials providing and fixing in position MS framed work such as grills, gratings with ends of bars, shouldered or riverted, framed gate and bars etc (Confirming to latest edition of IS 2062) using standard section of MS angles, channels, flats, plates etc. The work includes fabrication of various units by necessary cutting, welding, bending, pointing, bolting etc. all complete as per the specification and direction of Engineer-in-charge.
Supplying, carrying to site all approved materials, providing and painting with Two coats of High gloss Synthetic Enamel Paint (Class – 1 / Grade – 1) confirming to latest edition of IS 2932 of approved make/ shade over a coat of Red oxide / Zinc chrome primer on Steel surfaces at all heights neatly without brush mark. The work shall include preparation of the surfaces by using sand/ emery papers, cleaning, removal of the scales, peeled surfaces, filling the pits/ depressions, nail – holes, knots etc. by putty and applying paint by using brush/ spray to get uniform finish without any patches including erection of safe/ rigid scaffoldings, cleaning the area after painting etc. all complete as per specifications and directions of Engineer-in-charge.
Supplying carrying to site all approved materials and providing Two coats Acrylic smooth exterior paint (weather coat ) of required shade ( Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on plastered surface at all heights. The work shall include preparation of the surfaces by using sand / emery papers , cleaning removal of the scales , peeled surfaces filling the pits / depressions , nail - holes knots etc, by putty and applying paint to get uniform finish without any patches and brush mark including erection of safe / rigid scaffoldings cleaning the area after painting etc. all complete as per specifications and directions of Engineer - in - Charge.
Labour charges for returning / back filling of excavated earth or any other materials in the trench side gaps of foundation, over newly laid sewer line or any other places including spreading, leveling, watering & well ramming in layers not exceeding 25 cm etc. all complete as per specification and direction of Engineer-in-charge.
Supplying carrying to site all approved materials and providing Two or more coats of distempering with 1st quality acrylic distemper( ready mixed) having VOC content less than 50gm /liters of approved manufacturer of required shaded colour including application of one coat of primer complete as per manufacturers specification on plastered surface at all heights. The work shall include preparation of the surfaces by using sand / emery papers , cleaning removal of the scales , peeled surfaces filling the pits / depressions , nail - holes knots etc, by putty and applying paint to get uniform finish without any patches and brush mark including erection of safe / rigid scaffoldings cleaning the area after painting etc. all complete as per specifications and directions of Engineer - in - Charge.
Total
ADD : GST @ 18% (( IGST18%) or (CGST @ 9% +SGST@ 9%)), Whichever is applicable
Add CESS @ 1%
GRAND TOTAL
INSTRUCTION TO TENDERER
GOODS AND SERVICE TAX (GST)
Bidder should indicate GSTIN No. (Copy of GST registration to be enclosed) and PAN No. (copy of PAN to be enclosed).
Tender will be considered/ accepted, if & only if the vendor has a valid GST Registration No.
Central Tax/ State Tax/ Integrated Tax/ Union Territory tax to be quoted as per GST Law.
Bidders to ensure correct applicability of Central Tax/ State Tax/ Integrated Tax/ Union Territory tax based on the Inter / Intra state movement Supply of goods and provision services or both.
Bidder shall mention the SAC Code/HSN Code for goods and services in accordance with GST law in their Bid and subsequently in their tax invoice. HAL, Koraput Division shall not be responsible for any error in SAC Code/HSN Code for goods and/or services specified by supplier/contractor.
The Tax Invoice for supply of Goods & Services should be raised as per the provision of GST Act & Rules and must compulsorily mention the following.
a. HAL, Korpaut Division GST registration number as 21AAACH3641R1ZJ
b. Name & address of supplier / Vendor/ Contractors
c. GSTIN of Supplier / vendors / Contractors
d. Consecutive Serial Number & date of issue
e. Description of goods or services
f. Total value of supply
g. Taxable value of supply
h. Tax Rate – Central Tax & State Tax or Integrated Tax, Cess
i. Amount of Tax charged
j. Place of supply
k. Address of delivery if different from place of supply
l. Signature of authorized signatory
Reimbursement of GST to the vendor is contingent upon complying with the following condition by the service provider.
i. Uploading the (invoices raised on HAL, KoraputDivision ) onward GST Return (GSTR-1) in GSTN Network portal within the statutory time period.
ii. Discharging the GST tax liability to the Government.
iii. Submission of Tax Invoice to HAL, Korpaut Division.
iv. Submission of proof of payment of GST to HAL, Korpaut Division.
v. Receipt of goods / services by HAL Koraput Division.
vi. Availment of Input Tax Credit by HAL, Korpaut Division .
In case GST credit is delayed/ denied to HAL, Korpaut Division, due to non/delayed receipt of goods and/or services and/or tax invoice or expiry of timeline prescribed in GST Law for availing such ITC, or any other reason not attributable to HAL, Korpaut Division, GST amount shall be recoverable from Vendor along with interest & penalty levied/ leviable on HAL, Korpaut Division, as the case may be.
In case vendor delays declaring such invoice in his return and GST credit availed by HAL, Korpaut Division is denied or reversed subsequently as per GST law, GST amount paid by HAL, Korpaut Division towards such ITC reversal as per GST law shall be recoverable from vendor/contractor along with interest & penalty levied/ leviable on HAL, Korpaut Division.
In case of discrepancy in the data uploaded by supplier in the GSTN portal or in case of any incomplete work/service, then HAL, Korpaut Division will not be able to avail the tax credit and will notify the supplier of the same. Supplier has to rectify the data discrepancy in the GSTN portal or issue credit note (details to be uploaded in GSTN portal).
For any such delay in availing of tax credit for reasons attributable to vendor (as mentioned above), interest as per the GST Act & Rules, along with penalty, if any will be deducted for the delayed period i.e. from the month of receipt till the month tax credit is availed, from the running bills.
Penalty amount so determined along with GST if applicable thereon shall be recovered from the contractor.
Any reduction in rate of Tax on any supply of goods or services or the benefit of input tax credit shall be passed on to the recipient by way of commensurate reduction in prices. Bidders have to submit declaration in their bid that they have complied with ‘Anti-profiteering clause’ under GST law.
The bidder’s quoted rates/ price should be after considering the Input Credit under GST law at their end, since GST on output (GST amount charged in Invoice) will be paid by HAL.
In case any changes in taxes and duties as per Gov. Notification (including GST), the same shall be applicable from time to time.
Quarters will be allotted to the awarded agency subject to availability & recommendation from the E-I-C/ O-I-C for which rents as applicable will be recovered from the running bills of the agency.
LIST OF WORK IN PROGRESS FOR THE WORK
Line No.
NAME OF THE CONTRACTOR
HINDUSTAN AERONAUTICS LIMITED KORAPUT DIVISION CENTRAL CONTRACT CELL
Name of the Work
Line No
Name of the Contractor
Check list and acceptance for submission of documents with tender
Constitution and Legal Status of Bidder
Submission of cost of Tender documents by way of DD/BC drawn in favour of HAL, Engine Division, Koraput, payable at SBI, Sunabeda (Scanned image of the same in jpg format only to be uploaded)
Submission of EMD Amount by way of DD/BC drawn in favour of HAL, Engine Division, Koraput, payable at SBI, Sunabeda (Scanned image of the same in jpg format only to be uploaded)
Submission of Banker’s Solvency certificate for an amount as mentioned in tender issued by any nationalized bank issued within a period of 12 months from the final date of submission of tender
Submission of Work order copies for having executed similar works in Govt./ Railways/PSUs/Reputed firms
Submission of Performance / Completion certificates from Govt./Railways/PSUs/Reputed Private Firms (supported with TDS certificate if from Reputed Private firms) in the last 7 years.
For Two works value
For Three works value
Submission of Contractor’s Registration Certificate with Govt./Quasi Govt./PSUs /Reputed Company
Submission of Income Tax Return for last 3 financial years.
Submission of Average Annual financial turnover during the last 5 years
Balance sheet for the last 5 years
Plant and Machinery details of work
Proposed work completion Schedule in the form of Bar Chart
Work in Hand in the required format
Bank Balance Statement for the last three months
Overdraft facilities available with the agencies
Submission of Copy of PF Registration
Submission of Copy of Labour License
Submission of Copy of PAN Card
Acceptance of “General Condition of Contract and Instruction to tenderers” and “Notice Inviting Tender” along
NEFT/RTGS Format Duly filled in (Original to be submitted in the office)
GST REGISTRATION NO:
Submission of Copy of ESI Registration
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NIT51.pdf
TENDER_DOCUMENT • 2.56 MB
2.GCC-WORKS-NEW-ED-APRIL.pdf
TENDER_DOCUMENT • 0.43 MB
3.AM.pdf
TENDER_DOCUMENT • 5.21 MB
CBO241.xls
TENDER_DOCUMENT • 0.12 MB
CBO302.xls
TENDER_DOCUMENT • 0.06 MB
15.UNDERTAKING.pdf
TENDER_DOCUMENT
15.UNDERTAKING_2.pdf
TENDER_DOCUMENT • 0.01 MB
UPBOQ241-2.pdf
TENDER_DOCUMENT • 0.54 MB
UPBOQ302-1.pdf
TENDER_DOCUMENT • 0.43 MB
EPSFORM.pdf
TENDER_DOCUMENT • 0.02 MB
EPS.pdf
TENDER_DOCUMENT • 0.02 MB
EPS_2.pdf
TENDER_DOCUMENT
WIP.xls
TENDER_DOCUMENT • 0.02 MB
CL.xls
TENDER_DOCUMENT • 0.04 MB
UNDERTAKING.pdf
TENDER_DOCUMENT • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .