Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.8 LAccepted-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹31.9 L+₹9,070 (0.29%)Rejected-Finance C 89 CECC VILL POST PATHOLI AGRA UP | AGRA | AGRA | UTTAR PRADESH | 283105 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹32.4 L+₹59,055 (1.86%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹32.8 L+₹97,855 (3.08%)Rejected-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹34.0 L+₹2.2 L (6.78%)Rejected-Finance 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
CERTAIN REPAIR TO E/M INSTALLATIONS UNDER GE(AF) TECH AREA AGRA
2021_MES_411917_1
8200/1284/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹96,000
Yes
27 Mar 2021
12 Jan 2021
5 Feb 2021
12 Jan 2021
3 Feb 2021
21 Jan 2021
12 Jan 2021 - 16 Jan 2021
60 days
Amount
Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed
Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed
S&F 15 mm bore galvanized steel water tubing, medium grade with and including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and as directed .
S&F 20 mm bore galvanized steel water tubing, medium grade with including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and as directed .
S&F in repair flushing cistern 10Ltr capacity body molded from design quality high impact poly propylene critical and functioned parts molded from engineering grade ABS Nylon and nylon glass complete including bracket and 15mm bore 450mm long PVC connection complete all as specified and as directed .
S&F in repair 15 mm dia bib tap cast copper alloy (fancy type), chromium plated ,'with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and as directed .
S&F in repair brass CP Stop cock/ Angle cock 15mm fancy type with long shank and cup (concealed type) complete all as specified and as directed .
S&F Fancy type (15 mm dia) Pillar taps ,cast copper alloy ,with capstan heads chromium plated screwed down high pressure, with or without letterd HOT or COLD with long screwed shanks and fly nuts ,screwed for iron pipe and fixed complete all as specified and as directed .
S&F in repair soap dish, fixed to plugs with chromium plated brass screws complete all as specified and as directed .
S&F in repair for PVC connection 15mm size with brass nuts of length 450mm complete all as specified and as directed .
S&F in repair chromium plated health faucet suitable for Europian western commode (EWC) including 15 mm size CP flexible tube of length 900 mm with nuts and washers complete all as specified and as directed
S&F in repair tripple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I of 500 ltrs capacity with & including 20mm dia PTMT float valve complete all as specified and directed.
S&F in repair tripple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I of 1000 ltrs capacity with & including 20mm dia PTMT float valve complete all as specified and directed.
S&F in repair chromium plated Toilet paper holder and fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repair for Wash basins, Vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed .
S&F CP brass wast coupling 32 mm bore for WHB complete all as specified and as directed .
S&F PVC wast pipe 32 mm bore , 900 mm long for WHB complete all as specified and as directed .
Supply and fix in repair white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 450 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed .
S&F in repair vitreous china wash down water closet pan (padestal pattern) with seat cover (including fixing bolts and flush pipe but excluding flusing cistern) etc complete all as specified and as directed .
S&F in repair mild steel CP curtain rod 25 mm dia including fancy type bracket and fixed to wall and making good the surface to match with existing complete all as specified and as directed .
Taking down cement / lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed .
M&L for rendering 15 mm thick on fare face of brick or concrete surface of walls in cement mortar 1:4 finished the surface even & smooth without using extra cement on internal wall surface complete all as specified and as directed .
M&L for rendering 15 mm thick on other than fair face of brick work of walls in cement mortar 1:6 finished the surface even & smooth without using extra cement complete all as specified and as directed .
M&L for rendering 10 mm thick in cement mortar 1:3 on brick or concrete surfaces on ceiling finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of whitewash complete all as specified and as directed .
M&L for preparation of old decorated surfaces of plastered or un-plastered surfaces of walls and applying one coat of distemper oil emulsion white or tinted including peparation of surface complete all as specified and as directed .
M&L for preparation of old decorated surfaces of plastered or un-plastered surfaces of walls and applying one coats of weather proof exterior emulsion including preparation of surface complete all as specified and as directed .
M&L for preparation of old decorated surfaces of plastered or un-plastered surfaces of ceiling and applying one coat of white wash including preparation of surface complete all as specified and directed.
M&L for welding in repair exc 2.5 cm but n.exc 5 cm in length , thikness of metal to be welded n.exc 6 mm complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/iron or aluminium frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads in each pane n.exc 0.5 sqm complete all as specified and as directed .
M&L for 3 mm thick sheet glass pin headed type and glazing with oil putty or fixed with beads in each pane n.exc 0.5 sqm complete all as specified and as directed .
S&F in repair brass chromium plated Tubular towel rail, 20 mm dia, D type, 600 mm long between flanges fixed with brass screws and wooden / plastic cleats complete all as specified and as directed .
Demolition of brick work masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excl ashlars facing,dressed stone work and pre-cast concrete articles complete all as specified and as directed .
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards including frame work ,of any thickness and in any position including cover fillets complete all as specified and as directed .
S&F GI powder coated frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 605 mm centre to centre all as specified and as directed.
S&F of 4 mm thick non asbestos fibre cement building board of approved make ,in ceiling fixed to aluminium snap grid frame work with hold screws as per manufacturers instructions complete all as specified and directed.
Dismantling of AC sheets and the like (corrugated /semi corrugated/plain) in roof covering including ridge all as directed.
S&F Pre-painting galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified.
S&F mild steel works as in wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 upto any ht of bldg complete all as specified and directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding/backing,removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed .
M&L for glazed ceramic coloured tiles 200x300mmx7mm thick on wall/vertical surfaces such as skirting, dados and riser to steps etc including laid over with and including 10mm thick 1:4 cement mortar for laying wall/vertical finish set and jointed in neat cement slurry and pointed in white or coloured cement to match all complete all as specified and as directed .
M&L for glazed ceramic coloured tiles 300x450mmx7mm thick on wall/vertical surfaces such as skirting, dados and riser to steps etc including laid over with and including 10mm thick 1:4 cement mortar for laying wall/vertical finish set and jointed in neat cement slurry and pointed in white or coloured cement to match all complete all as specified and as directed.
M&L for 16 to 18 mm thick Granite (of any type ) machine cut, in urinal partition,on kitchen platform,pillars and similar work and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed .
Demolition of cement Concrete in ground floors and paving exc 15 cm thickness (below or above ground level) complete all as specified and as directed .
M&L for 100 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in sub base of floors and the likes; complete all as specified and as directed.
M&L for 25 mm thick plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring in leveling course complete all as specified and as directed .
M&L for Non skid, joint free (edgecut) coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exc 0.06 sqm but not exeeding 0.11 sqm as in floors etc laid over with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed .
M&L for Non skid, joint free (edge cut) coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exc 0.11 sqm but not exeeding 0.18 sqm as in floors etc laid over with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed .
M&L for joint free non skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exeeding 0.18 sqm, as in skirtings, dado etc. laid over with and including 10mm thick rendering in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed .
M&L for Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tiles not exceeding 0.36 sqm as in floors etc. laid over with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed .
M&L for Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tile not exceeding 0.36 sqm as in skirting etc laid over with and including backing coat or bedding layer of 10 mm thick 1:4 cement mortar for laying wall/vertical finish, jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed .
M&L for machine cut kota stone slab flooring 20mm thick over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for machine cut kota stone slab 20 mm thick as in dado, riser, steps and the likes laid over and including rendering 15 mm thick in CM 1:4 for backing layer complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection and the likes; finish the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for Chequered cement concrete tiles 300x300x25mm thick with mixture of white cement and pigment to math the shad of tile, jointed and pointed in near cement slurry in floors, laid on with and including screed bed or bedding layer of 15mm thick in cement mortar 1:6 complete all as specified & directed
M&L for Sand filling under interlocking tiles or in foundations and consolidation complete all as specified and as directed .
M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N / Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment complete all as specified and as directed .
M&L for Outdoor Vitrified ceramic tiles 9 to10 mm thick (Square / rectangular) light shade polished area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 sqm as in floors etc laid over with and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed .
Taking down door/window chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified and as directed .
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & sketch shown in section 8 of SSR part II complete all as specified and as directed .
S & F solid PVC door frame of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawings. complete all as specified and as directed .
S&F 100 mm stainless steel butt hinges medium grade complete all as specified and as directed .
S&F Aluminium anodised barrel tower bolt 200 mm long of extruded section and fixed complete all as specified and as directed .
S&F 125 mm size extruded Aluminium alloy handles fabricated type complete all as specified and as directed .
Demolition of reinforced cement Concrete ( reinforcement cut as required facilate demolition) of any description and in any position complete all as specified and as directed .
Use & waste of form work to sides of pillars, posts and columns for rough finished surface of concrete complete all as specified and as directed .
M&L for RCC 1:2:4, type B1, using 20 mm graded stone aggregate as in coping, columns, pillars, piers, posts and struts & similar RCC works complete all as specified and as directed .
M&L for steel reinforcement of TMT bars (Fe-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally, hooking end and binding with mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and as directed .
M&L for steel reinforcement of TMT bars (Fe-500 Grade) 6 to 8mm dia as in stirrups cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for 40 mm thick precast cement concrete louvres and jallies in 1:2:4, type B-0 (Using 12.5mm graded stone aggregate) including suitable reinfocement, all moulding etc set in CM 1:4 complete all as specified and directed.
M&L for dismantling wrought iron or mild steel work of any description not otherwise provided for as in iron posts or struts and the likes; complete all as specified and as directed.
Dismantling of fencing wire mesh of any type and description complete all as specified and as directed .
Excavating in post holes (or similar holes) in soft/loose soil each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and as directed .
M&L for PCC 1:4:8 type D-2 ( using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed .
M&L for mild steel work as in posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc) including all necessary bolting or riveting and spot welding etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed .
S&F steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts of any size and description and fixing to iron post and embedding in PCC platforms of pumps and motor complete all as specified and as directed.
Supply only chain link fencing mild steel galvanised of any size and type (size of mesh and dia of wire as approved by GE) complete all as specified and as directed.
Fixing only chain link fencing of any type fixed to RCC / steel post with mild steel flat & nut bolt etc.complete all as specified and as directed. Note: (i) Supply only fencing, will be measured and paid separately. (ii) Supply and fix mild steel nut bolt, line wire and flat will be measured and paid separately.
S&F Mild steel round bars 10mm dia and over as in strengthning bars for chain link fencing conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Dismantling of structural steel work including doors, gates framed trusses etc. complete all as specified and as directed.
S&F mild steel framed work such as grills gratings / cattle trap etc. with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth, not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Taking down existing tarfelt or other roof treatment from roof and rubbish off the premises including removing debries at a places complete all as specified and as directed
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in levelling course/ padding over roof complete all as specified and as directed .
M&L for 15 mm thick screed in cement mortar 1:4 on concrete surfaces mixed with WPC, finished even and fair w/o using extra cement complete as in roof all as specified and as directed. Note : WPC shall be measured & paid seperately.
Supply only integral water proofing compound confirming to IS-2465-1075 complete all as specified and as directed .
M&L water proofing treatment to RCC Roof slab including parapet comprising with the following course of treatement complete all as specified and as directed from bottom to top :- (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of Roof including parapet surfaces. (b) Over the priming coat laying one layer APP based polymeric membranes of approved manufacturer, 3mm thick weight not less 3.50 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 160 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flushing in a coat of aluminium paint over roof surfaces. (i) Laying APP based polymeric membranes shall be done by torch on method as per manufacturer's instructions. (ii) A minimum overlap of 100mm shall be made and at the end 75mm shall be made at the sides of the polymeric membranes respectively and sealed all overlaps and joints as per Manufacturer's instructions. (c) Applying two coats of aluminium paint over top of APP membrane @0.10Kg/Sqm.
Disconnecting existing tanks, set aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and refixing in position of capacity exc 250 Ltrs but n.exc 500 Ltrs complete all as specified and as directed.
C P Singh and Co
M/s K S Builders
deva engineers
M/s Singh Electric Co
Shiv Krishan Associates
Asha Construction
garg construction company
GUPTA ENGINEERING WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .