| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC 10 WATARLOO STREET KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹67,141 (11.6%)Rejected-Finance MOSAT HARIPUR RD P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.6 L+₹1.8 L (30.3%)Rejected-Finance 1 C NEPAL BANERJEE STREET P O P S KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 27E 26 BABURAM GHOSH RD KOLKATA 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | - | Rejected-Technical Shortfall documents not submitted | |
| 5 | Rejected-Technical 48 1B RAMTANU BOSE LANE GIRISH PARK KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | - | Rejected-Technical nonsubmission of requisite documents. |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
21 Oct 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Temporary Electrical Installation work in connection with Chhat Puja 2024 under Maidan Electrical Sub-Division PWD.
2024_WBPWD_761601_1
WBPWD/EE-KED/eNIQ-33Q/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
3 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
13 Nov 2024
3 Oct 2024
23 Oct 2024
3 Oct 2024
21 Oct 2024
17 Oct 2024
Amount
Supply and drawing of the following sizes pvc insulated and unsheathed multistranded copper wire on hire basis with carrying cost at the sites and dismantling as per direction of EIC including socketing,glanding and necessary finishing as required.(Hiring period up to 3 days).
7/0.036(7/20) single core copper wire
2.5 Sqmm single core copper wire
Supply and drawing of the following sizes pvc insulated and unsheathed multicore aluminium armoured cable on hire basis with carrying cost at the sites and dismantling as per direction of EIC including socketing,glanding and necessary finishing as required. (Hiring period up to 3 days).
4C X 16 Sqmm cable
4C X 25 Sqmm cable
Providing and installation on hire basis 500 V , 100Amp 4 Pole MCB isolator as incomer with 32Amp or 16 Amp per way, 6 Way TPNMCBDB with all arrangement in a outdoor type pillar box incl interconnection with proper socketing and dismantling including proper earthing arrangement as direcyted by EIC after the programme for 3 Days after complition of the job .(Hiring period up to 3 days).
Providing and installation on hire basis 500 V, 250 A on load changeover switch incl interconnection with proper socketing and dismantling including proper earthing arrangement as direcyted by EIC after the programme. (Hiring period up to 3 days).
Providing and installation on hire basis 500 V, 63Amp/32Amp 4 Pole MCB fixed on sheet metal box with proper socketing and dismantling including proper earthing arrangement as direcyted by EIC after the programme.(Hiring period up to 3 days).
Providing and Fixing on hire basis following LED Flood light fittings complete with all accessories and dismantling as directed by EIC after the programme. (Hiring period up to 3 days).
Minimum 150 Watt LED Flood fittings.
Minimum 200 Watt LED Flood fittings.
Providing on hire basis 440V, 3 Phase CPCB approved Diesel Generator set for Prime/ Standby operation with operation, maintenance, transportation & mobil but without Disel as per directyion of EIC for 02 days
3 nos 62.5 kVA
Providing on hire basis 10/9 mtrs steel tublar pole with Arm Bracket (Single/Double As required as per site condition) and dismantling including proper earthing arrangement as directed by E.I.C after complition of the job (Hiring period up to 3 days). .
Maintenance and operation of the above installation during night time (8 Hrs) by 3 Numbers Skilled and 3 Numbers Unskilled labour per day after complition of the job (Hiring period up to 3 days).
Gurading of the above electrical installation with required numbers of man power round the clock(24 Hrs) from the beginning of the installation and upto the dismanting time for proper upkeepment and preventing any unwanted incidents like theft, willful damage etc( no additional charge will be paid for any unwanted incidents) after complition of the job (Hiring period up to 3 days).
Providing & Earthing on hire basis with 50 mm dia GI Pipe 2.5 to 3 mtrs. Long and 6/8 SWG GI wire with galvanized nuts and bolts washer etc. below ground level on hire basis and dismantling the same. (Hiring period up to 3 days).
Transportation charge for the materials from Company's godown to Site and return back to godown after use.
18 % GST on the total amount from SL no 1 to 12.
Supply of disel for above DG sets - Supply and refuelling of the above DG Sets as required with all necessary charges
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly sockedted. 7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar. 12) P.A. System and Microphone shoud be earthed. 13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 14) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
GHANASHYAM ELECTRIC STORES (BID ID -5705765)
SHREE GANESH ENTERPRISE (BID ID -5699989)
technical_1685629.pdf
PDF • 0.55 MB
techsummary_1685629.pdf
PDF • 0.55 MB
finance_1685629.pdf
PDF • 0.55 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1685629.pdf
PDF • 0.55 MB
workorder.pdf
PDF • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .