| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹33.7 L | L1 | Accepted-AOC Accepted due to L1 |
| 2 | L2₹40.0 L+₹6.3 L (18.6%)Rejected-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | ₹40.0 L+₹6.3 L (18.6%) | L2 | Rejected-AOC higher rate |
| 3 | L3₹40.4 L+₹6.7 L (19.8%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹40.4 L+₹6.7 L (19.8%) | L3 | Rejected-AOC higher rate |
| 4 | L4₹43.7 L+₹10.0 L (29.7%)Rejected-AOC | ₹43.7 L+₹10.0 L (29.7%) | L4 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND52/202223 REPAIR MAINT OF SUBMAIN WIRING, DISTRIBUTION BOARD, LT PANEL, COOLING APPLIANCES, INTERNAL EM FITTINGS FIXTURES AND MISC WORKS AT CERTAIN BUILDINGS OF SP MARG, ABHM, TPT UNIT ASC AND DAD COMPLEX PANCHWATI AND PERIODICAL SERVI
2022_MES_546774_1
GE/ND-52/2022-23
Open Tender
Civil Works
Item Rate
210 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹99,000
Yes
25 Oct 2022
22 Aug 2022
21 Sept 2022
22 Aug 2022
19 Sept 2022
5 Sept 2022
Amount
Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints is DAD Complex Panchwati. Contractor shall provide minimum one tradesmen (electrician) for site to attend the complaint in all working days between 0830Hrs to 1700Hrs including holiday and Sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 100/- for not attending the complaint upto 24 hours and after 24 hours Rs. 200/- per 24 hours shall be recovered from the contractor due. 5. All the complaint slip, register, necessary tools & other connected document will be provided by the contractor without any extra cost. 6.The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid separately as S&F here-in-after.
S&F in replacement of switch piano flush type 6 Amp, SP, one way 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of switch piano flush type 6 Amp SP two way 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of bell push switch piano flush type 6 Amps, SP, 230 Volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of switch piano flush type 16 Amp, SP, one way 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of piano flush type socket out let 5 pin 6 Amp, 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of piano flush type socket out let 6 pin 16 Amp, 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of piano type electronic fan regulator suitable for 1200/1400 mm ceiling fan all as specified. Make:-Philips/schneider/anchor
S&F in replacement of call bell suitable for 230 volts AC all as specified. Make:-Philips/schneider/anchor
S&F in replacement of ceiling rose 3 terminal / PVC / Polycarbonate, insulated body all as specified.
S&F in replacement of decorative laminated sheer 3 mm thick of size 9"x13" including necessary cutting of sheet for fixing switch/socket complete as specified and directed
S&F in replacement of decorative laminated sheet 3 mm thick of size 9"x11" including necessary cutting of sheet for fixing switch/socket(As per enclosed diagram) complete as specified and directed
S&F in replacement of decorative laminated sheet 3 mm thick of size 8"x5" including necessary cutting of sheet for fixing switch/socket (As per enclosed diagram)complete as specified and directed
S&F in replacement of decorative laminated sheet 3 mm thick of size 5"x5" including necessary cutting of sheet for fixing switch/socket(As per enclosed diagram) complete as specified and directed
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1.5 Sqmm all as specified. Make:RR/POLYCAB/HAVELLS
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 2.5 Sqmm all as specified. Make:RR/POLYCAB/HAVELLS
Supply only in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed by Engr-in-Charge. (Make : Legrand/Havells/indoasian)
Supply only in replacement for MCB SPN 32 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed by Engr-in-Charge. (Make : Legrand/Havells/indoasian)
Supply only in replacement MCB TPN/ Isolator 4P ,63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. (Make : Legrand/Havells/indoasian)
S&F in replacement of MCCB TP 125 Amp, 415 Volts,36kA thermal type complete all as specified. MAKE:-Legrand/Indoasian/Havells
S&F in replacement of MCCB TP 160 Amp, 415 Volts ,36kA adjustable type complete all as specified. MAKE:-Legrand/Indoasian/Havells
S&F in replacement of MCCB TP 250 Amp,415 Volts, 36kA thermal type complete all as specified. MAKE:-Legrand/Indoasian/Havells
S&F in replacement of metal clad plug top 20 Amp, 230 volts AC all as specified. MAKE:-Legrand/Indoasian/Schneider
S&F in replacement of metal clad socket outlet 20 Amps, 230 volts AC all as specified. MAKE:-Legrand/Indoasian/Schneider
S&F in replacement of LED Integrated Batten T5 10 watt - 2FT White, indoor decorative polycarbonate extruded T5 LED batten --integrated type environmental friendly complete all as specified and directed. Make : Cat Part No LHEXACP7IN1W010 of Havells or equivalent Model in Crompton/Philips.
S&F in replacement of LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminium extruded T5 LED batten -integrated type environmental friendly complete all as specified and directed. Make :Cat Part No LHEXARP7IN1W020 of Havells or equivalent Model in Crompton/Philips/Bajaj.
Supply only in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base complete all as specified and directed. Make: CAT LHFHCHE1TL1W020 of Havells or equivalent make in Crompton/Phillips.
S&F in replacement of LED Building security light fitting 25W energy saving and environmental friendly LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection as directed. Make: CAT Part No SL45WLED757PASYTOPC of Havells or equivalent model in Crompton/Phillips).
S&F in replacement of B-22 holder suitable Led bulb 9 watts all as specified.
S&F in replacement of fan capacitor 2.5 Mfd all as specified. Make: EPCO Cat part No 32415G5255J213 or equivalent in approved makes
S&F in replacement of fan capacitor 3.15 Mfd all as specified. Make: Cat part no B32415G5315J213 of Epco or equivalent in approved makes
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing Complete all as specified and directed by Engineer-in-charge. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush where ever required Complete all as specified and directed by Engineer-in-charge. Note : The lathe machine work if necessary to making upper/lower sheet of fan will be measured under this item only.
All as per ser item No 33 above but 1400 mm sweep
All as per ser item No 33 but exhaust fan 230/300 mm sweep
All as per ser item No 33 but exhaust fan 450/600 mm sweep
S&F in replacement of ceiling fan Ball bearing of suitable size & model (as per sample). Make:- NBC/ SKF
S&F in replacement of 'U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of any size/ make
S&F in replacement of Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete.
S&F in replacement of Canopy of Ceiling fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete.
S&F in replacement of blade (set of three) of Ceiling fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete.(As per sample)
S&F in replacement of blade (set of three) of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete.(As per sample)
S&F in replacement of metal frame of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete.(As per sample)
S&F in replacement of motor (copper winding) of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete.(As per sample)
M&L for spray painting two coat (white colour) with synthetic enamel paint to Ceiling fans/Exhaust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
M&L for spray painting two coat (white colour) with synthetic enamel paint to Geysers 25/50 Litres capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
S&F in replacement of heating element of 1.5 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed (As per sample).
S&F in replacement of heating element of 2.0 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed Make Venus or As per sample.
S&F in replacement of storage tank made out of stainless steel sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank.
S&F in replacement of insulating material (Glass wool) for 25 litre capacity Geysers all as directed by Engineer -in - charge.
S&F in replacement of base plate assembly 20 SWG heavy duty suitable for 25 litre capacity stainless steel tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample).
S&F in replacement of chromium plated connection pipe 600mm long with two brass adopters washers and connecting up complete all as specified and directed.
S&F in replacement of PVC connection pipe 450mm long with two brass adopters washers and connecting up complete ISI mark all as specified and directed by Engr-in Charge
S&F in replacement of safety nut for high pressure release (As per sample).
S&F in replacement of non return valves 15mm dia and connecting up complete (ISI marked).as per sample
S&F in replacement of top cover for geysers of 25 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) all as directed.
S&F in replacement of bottom cover for geysers of 25 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces all as specified and directed.
S&F in replacement of outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horizontal type all as specified and directed.
S&F in replacement of thermostat (ISI Marked) for 25 Litres capacity Geyser. Make : Daspass/Theeta/TTE
S&F in replacement of indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample)
S&F in replacement of mild steel hole fastener 10mm dia, 100mm long including nut and washer.
S&F in replacement of 15 mm gun metal valve..
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket and making good the disturbed surface of wall/ floor complete all as specified.
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switches, sockets & fan regulators for the following:- Note :- In existing conduit wiring (new conduit will be added where there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/Junction boxes).
(a) One light/fan point controlled by one No, one way switch.
(b ) 6 Amp socket outlet point controlled by one No, one way switch on same board
(c ) 6 Amp socket outlet point controlled by one No, one way switch on independent board
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switches and sockets on independent board. Note :- In existing conduit wiring (new conduit will be added where there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/Junction boxes). Note for item No 64 & 65:- (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required. (iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
S&F in replacement of PVC Casing Caping of size 1" complete all as specified & directed.
S&F in replacement of PVC conduit 20mm dia, rigid, complete all as specified & directed.
S&F in replacement of flexible PVC pipe of 20mm dia complete all as specified & directed.
S&F in replacement of LED Glass Bulb 10 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings complete all as specified and directed by Engineer -in-Charge. Make: havells/Philips/Crompton.
S&F in replacement of single core, FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 4 Sqmm complete all as specified and as directed. Make:Polycab/Havells/RR.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified. Make:-RR/Havells/Polycab
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10 sqmm complete drawn in existing conduit along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified. Make:-RR/Havells/Polycab
S&F in replacement of metal clad enclosure with plug and socket 20 Amp with one MCB SP, 20 Amps 230 volts AC all as specified. Make:-Havells/indoasian/Legrand
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 4 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified. Make:-Havells/indoasian/Legrand
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 8 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified. Make:-Havells/indoasian/Legrand
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified. Make:-Havells/indoasian/Legrand
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified. Make:-Havells/indoasian/Legrand
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified. Make:-Havells/indoasian/Legrand
Supply only in replacement Rugby Bulk head 9 watt in die cast aluminium housing & frosted glass complete all as specified and directed by Engineer-In-Charge Make: Cat LHKL01160099 of Havells or equivalent model in Crompton/Bajaj/Phillips
S&F in replacement of Exhaust fan Louvers 300 mm Size of iron upto forth floor including taking out old louvers complete all as specified. Note:-Staircase arrangement for fixing louvers will be made by contractor.
Preventive maintenance of ceiling fan/exhaust fan/cabin fan/wall mounted fan of any make & any size including checking of fan clamp, nuts, bolts & washer and carry out the oiling/greasing all as specified and directed by Engr-in-charge. (Note: Spare parts shall be measured & paid separately).
Preventive maintenance of 25 Ltrs geysers of any make including checking of its fastener/ nuts, bolts & washer and carry out checking/testing of cut out, thermostat, element, assembly all as specified and directed by Engr-in-charge. (Note: Spare parts shall be measured & paid separately).
Preventive maintenance checking of elect DBs (SPN/TPN/Load line DBs ) switch board such as checking the looses connection in MCBs , cutting the burnt cables and reconnecting to MCBs/DBs spare required shall be maintained and paid under relevant items
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing as directed by Engr-in-Charge.
S&F in replacement of two core flexible cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1 Sqmm complete all as specified and as directed. Make:RR/POLYCAB/HAVELLS
S&F in replacement of aesthetically designed ceiling/surface mounting circular shaped decorative green perform sleek LED downlighter of 09 W fixture with opal diffuser to give glare free light including suitable LED lamp complete all as specified and as directed.
Taking down copper/aluminium point wiring (fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,Light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with PVC FRLS insulated unsheathed multi-stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in existing conduits /PVC casing capping /PVC concealed conduit and its accessories, including replacement of factory made steel boxes suitable for modular switch/sockets including modular plates of suitable size as per site requirement for the following Note: Cutting & chasing, if required, shall be measured/paid under relevant items
One light/ceiling fan/exhaust fan point controlled by one no., one way switch 5/6 amps.
One light point controlled by one no's, two way switch, 5/6 amp
One bell / buzzer point controlled by one bell push
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp on independent board.
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp on same board.
All as per item No 91.00 here-in-before but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 amp socket outlet point on independent board complete all as specified and as directed.
All as per item No 91 here-in-before but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core cable on independent circuit complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good the disturbed surface, cutting not exc. 10 cm girth on brick walls complete all as specified and as directed.
S&F Modular switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame complete all as specified and as directed.
S&F Modular switch 6 amps 250 V AC two way with ISI mark including 6 amps switch frame complete all as specified and as directed.
S&F modular switch 16 A SP one way 240 volts complete all as specified and as directed.
S&F modular socket 6 A Multi socket for 2/ 3 pin, 240 volts complete all as specified and as directed.
S&F modular socket outlet 16 A-2/3 pin combined 240 volts complete all as specified and as directed.
S&F bell push, flush type 5 A 240 volts complete all as specified and as directed.
S&F modular bell push 6A with Neon 1 module 240 volts complete all as specified and as directed.
S&F electronic fan regulator modular type 100Watt step type Double Modular as per existing complete all as specified and as directed.
S&F switch piano flush button single pole one way 6 amps complete all as specified and as directed.
S&F switch piano flush type 15 amps single pole one way complete all as specified and as directed.
S&F socket outlet 5/6 amps 2 in 1, 3 pin flush type complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 amp, flush type complete all as specified and as directed.
S&F STEP type electronic fan regulator flush type 230 volts complete all as specified and as directed.
S&F in repair electric bell Ding-Dong AC 230 Volt complete all as specified and as directed.
S&F ceiling rose, 3 phase/ PVC/ polycarbonate isolated body complete all as specified and as directed.
Taking down DB of SPN 4/8/12 way type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 12 way with 200 amps rated bus bar complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 8 way with 200 amps rated bus bar complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 4 way with 200 amps rated bus bar complete all as specified and as directed.
Taking down MCB 6-32/40-63 Amps SP/SPN and 40-63 Amps TPN type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F MCB TPN 40 to 63 Amps, 415 V, 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F of MCB SPN 40 to 63 Amp 240 volt 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F of MCB SPN 6 to 32 Amp 240 volt 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F MCB SP 40 Amp to 63 Amp, 240 V, 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F MCB SP 6 Amp to 32 Amp 240 volts 10 kA rupture capacity, series 'C' complete all as specified and as directed.
Taking down Metal clad enclosure with plug and socket 10/20 Amps, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F sheet Metal enclosure with plug and socket, 10 Amp, 240 volts with one MCB single pole, complete all as specified and as directed.
S&F sheet Metal enclosure with plug and socket 20 Amp 240 volts with one MCB single pole complete all as specified and as directed.
S&F in replacement LED batten of 20 Watt 230Volt (size 4 ft), box type complete with LED Tube Light 20 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement of Endura Linear LED batten of 10 W (2 ft.), extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver in AC complete all as specified and as directed.
S&F in replacement aesthetically designed circular shaped Recess & surface /PENDANT MOUNTING designer LED light of 18 W fixture with PMMA diffuser to give glare free light, high performance low-height back lit downlighter, Robust PDC aluminium housing, Efficacy 100LM/W complete all as specified and as directed.
Supply & fix in replacement aesthetically designed Wall mounted decorative wall LED light of 6 W fixture with opal diffuser to give glare free light including suitable LED lamp of 6 W having Lamp base E27 complete all as specified and as directed.
Supply & fix in in replacement aesthetically designed Wall mounted decorative mirror LED light of 3.6 W fixture with opal diffuser to give glare free light including suitable LED lamp of 3.6 W having Lamp base E27 complete all as specified and as directed.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 12 W fixture with opal diffuser to give glare free light including suitable LED lamp of 12 W complete all as specified and as directed.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 15 W fixture with opal diffuser to give glare free light including suitable LED lamp of 15 W complete all as specified and as directed.
Supply & fix in replacement 3 watt aesthetically designed recessed/surface mounted decorative downlighter/ LED Spot Light, with CRI >80, Beam angle 36 degree, Vertical Tilt 30 degree, complete all as specified and as directed.
Supply & fix in replacement 6 watt aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree , Vertical Tilt 30 degree complete all as specified and as directed.
Supply & fix in in replacement 2x2 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified and as directed.
Supply & fix in replacement 9 watt aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree , Vertical Tilt 30 degree complete all as specified and as directed.
Supply & fix in replacement 1x4 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified and as directed.
Supply & fix in replacement 12 watt, aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree, Vertical Tilt 30 degree complete all as specified and as directed.
S&F in replacement factory made load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and as directed.
S&F in replacement factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and as directed.
Supply and fix in replacement Metal clad plug top of capacity 20 Amp, 240 volts complete all as specified and as directed.
Supply and fix in replacement Metal clad socket of capacity 20 Amp, 240 volts complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 8'' X 12'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 8'' X 5'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 7'' X 4'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated T cover sheet 3mm thick of size 2/3 inch dia complete all as specified and as directed.
Supply and fix only fan capacitor of the following capacity :-
Supply and fix only non metallic rigid PVC conduit medium grade 20 mm dia, ISI Mark complete all as specified and as directed.
Supply and fix only non metallic rigid PVC casing caping, ISI Mark complete all as specified and as directed.
Taking down of ceiling fan/ exhaust fan, dismantling of blades, transportation to workshop for carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and as directed.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush, ball bearing wherever required complete all as specified and as directed.
All as per ser item No 157.00 here-in-before but exhaust fan 230/300 mm sweep
All as per ser item No 157.00 here-in-before but exhaust fan 400 mm sweep
S&F in repair ceiling fan Ball bearing of suitable size & model (as per sample) complete all as specified and as directed.
M&L for replacing 'U' clamps with rubber reel, bolts, nuts, washers and safety pin for ceiling fan of any size/ make complete all as specified and as directed.
M&L in repair for Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of synthetic enamel white paint complete all as specified and as directed.
S&F in repair Canopy of Ceiling fans of 1200/1400mm swipe size heavy duty duly painted with one coat of synthetic enamel white paint complete all as specified and as directed.
M&L for spray painting (white colour) with synthetic enamel paint to Ceiling fans/Exhaust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black synthetic enamel paint complete all as specified and as directed.
Supply & fixing in replacement flat ceiling fan blade of aluminium, 1mm thickness suitable for 1200mm sweep ceiling fan,12-15 degree tilted, having 3 Nos in each set complete all as specified and as directed.
Supply & fixing in replacement flat exhaust fan blade of aluminium, 1mm thickness suitable for 230/300/400 mm sweep exhaust fan, 12-15 degree tilted, having 3 nos. in each set complete all as specified and as directed.
S&F in repair Frame of 230/300 /400 mm Aluminium metallic exhaust fan including taking down of old frame complete all as specified and as directed.
Supply & fixing in repair flat ventilation fan blade of PVC, 1mm thickness suitable for 230/250/300mm sweep exhaust fan,12-15 degree tilted, having 4 nos. in each set complete all as specified and as directed.
S&F in repair ventilation fan motor of size 230/250/300 mm including taking down of old ventilation fan motor complete all as specified and directed.
S&F in replacement of PVC Frame of 230/250/300 mm ventilation fan including taking down of old frame complete all as specified and as directed.
Taking down carefully Geysers 25/50 Ltr capacity, opening for inspection, cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc. complete all as specified and as directed.
M&L for spray painting (white colour) with synthetic enamel paint to Geysers 25/50 Litres capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and as directed.
M&L in repair for heating element of 2.0 kW (Circular) as required at site including rubber washers (ISI marked) etc complete all as specified and as directed.
M&L in repair for heating element of 2.0 kW (triangular) as required at site including rubber washers (ISI marked) etc complete all as specified and as directed.
S&F in repair storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 50 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and as directed.
S&F in repair storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and as directed.
M&L for replacement of insulating material (Glass wool) for 25/ 50 litre capacity Geysers complete all as specified and as directed.
S&F in repairs base plate assembly 20 SWG heavy duty suitable for 50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
S&F in repairs base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
M&L in repair for chromium plated copper connection pipe 600/1000 mm long with two brass adopters washers and connecting up complete all as specified and directed.
M&L in repair for safety nut for high pressure release (As per sample) complete all as specified and as directed.
M&L in repair for top cover for geysers of 25/50 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and as directed.
S&F in repair for bottom cover for geysers of 25/50 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces complete all as specified and as directed.
S&F in repair outer cover for geyser made out of MS sheet suitable for 50 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F in repair outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F in repair thermostat (ISI Marked) for 25/50 Litres capacity Geyser complete all as specified and as directed.
S&F in repair indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample) complete all as specified and as directed.
Supply and fix in repair mild steel hole fastener 10mm dia, 100mm long including nut and washer complete all as specified and as directed.
Taking down MCCBs any type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/panel etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 125A breaking capacity not less than 25KA, Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 250 Amp, breaking capacity not less than 36 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
M&L for complete servicing of gate sensor including rewiring, cleaning, repair of electronic motor, sensor and replacement of all other required accessories for smooth functioning complete all as specified and as directed. Note: Cost of replacement of spare parts is deemed to be included in quoted rate.
S&F in replacement gang box with modular plate cover two module suitable for fitting one 5Aswitch /socket complete all as specified and as directed.
S&F in replacement gang box with modular plate cover four module suitable for fitting one 5A switch and one socket complete all as specified and as directed.
S&F in replacement gang box with modular plate cover four module suitable for fitting one 15A switch and one socket complete all as specified and as directed.
S&F in replacement gang box with modular plate cover six module suitable for fitting one 5Aswitch /socket complete all as specified and as directed.
S&F in replacement gang box with modular plate cover eight module suitable for fitting one 5A switch and one socket complete all as specified and as directed.
S&F in replacement gang box with modular plate cover twelve module suitable for fitting one 15A switch and one socket complete all as specified and as directed.
M&L for taking down ceiling fan & taking out old unsv ceiling fan motor & replacement with new copper winding motor one by fixing nut bolts complete all as specified and as directed by Engr-in-Charge
S&F in replacement LED Bulb inverter type,9watt,including suitable lamp holder for fitting in pendant holder complete all as specified and directed.
Disconncting,dismantling the existing LT panel Meter board of size 1500mmX1800mmX350mm,415 Volt,3 phase,4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to users DB after carry out the following repair works in panel
S & F in replacement of Din rail for MCB SPN 63 Amps
Cutting the rusted out portion of the LT panel board and Welding with new sheets of thickness 2 mm including necessary fabrication at site not exceeding 1sqmtr and necessary painting etc.
Replacement of view glass for meter compartment.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldgs. no & respective quarter number ., danger sign board etc.
Reconnecting the sub mains 25 sqmm single core copper cable to the MCB's and MCCB's terminal with the help of copper lugs and thimbles and tightening properly in such a way that no leakage current found during site inspection.
Disconnecting, dismantling the existing LT panel Meter board for LIFT of size 600mmX1400mmX300mm with angle frame 50mmX50mmX6mm ,415 Volt,3 phase,4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to users DB after carry out the following repair works in panel as directed by Engr-in-charge.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldgs. no & respective quarter number ., danger sign board etc.
Welding of rusted out sheets with new sheets of thickness 2 mm.(not exceeding 1sqmtr)
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc.
M & L in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25X4 mm galvanized iron strip.
Supply and fixing in replacement at the place of old SFUs, MCCB- 4 pole-415 volt of capacity 250 amp, breaking capacity not less than 25 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. all as specified and directed by Engr-in-Charge Make : Legrand cat part No 420219 or equivalent Make in Schneider/L&T
Disconnecting mains connection and taking out old sub main wiring single core 6/10 sqmm and one single core 2.5/4/6/10 sqmm aluminium conductor cable from the concealed conduit from the wall/ceiling and making good to the disturbed surface all as specified.
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 6 sqmm complete drawn in new PVC conduit in surface wall and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly Make Havells cat No WHFFDN A1 6x 0 all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft. Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters & making good the disturbed surfaces including putty filling & oil bound emulsion painting complete.
M&L for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 10 sqmm complete drawn in new PVC fixed to wall conduit and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly Make Havells cat No WHFFDN B1010 all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft . Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters & making good the disturbed surfaces including putty filling & oil bound emulsion painting complete
Disconnecting mains connection and taking out old distribution board 8/12 way SPN with 200 amp rated bus bar complete with MCB and making good to the disturbed surface all as specified.
S&F factory made sheet steel distribution boards, double door, SPN, 12 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
S&F in replacement MCBs 6-32 Amps, SP, 10 kA rupturing capacity 'C' curve and fixing in DBs all as specified.Make Legrand cat No 408587-95 or equivalent Make in Schneider/L&T
S&F in replacement MCBs 40-63 Amps, SPN, 10 kA rupturing capacity and 'C' curve fixing in DBs all as specified Make Legrand Cat No 408618-20 or equivalent Make in Schneider/L&T
S&F in replacement MCBs 6-32 Amps, SPN, 10 kA rupturing capacity and 'C' curve fixing in DBs all as specified Make Legrand Cat No 408618-20 or equivalent Make in Schneider/L&T
Material and labour for cleaning and painting to old steel surfaces of Desert cooler with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide primer including scraping/rubbing with wire brush on old surface of Desert cooler. complete all as specified and directed by Engineer-in-Charge
S&F in replacement Desert Cooler fan motor capacity 1/5 HP, 1400 RPM single phase with fan blade and stand complete.
S & F in repairs Aluminium fan blade for fan motor of desert cooler
S&F in repairs capacitor 4 MFD for fan motors of desert coolers.
S&F in replacement PVC insulated and PVC sheathed cable copper conductor 3 core (superior quality) complete.
S&F in replacement PVC water distributor of 3 out lets with MS nuts & bolts complete
S&F in replacement PVC elbow suitable for desert cooler
S&F in replacement PVC pipe 15 mm dia for Desert Cooler Pump complete.
S&F in replacement water lift pump plastic body of 220-240 Volts AC Supply single phase complete all as directed by Engr- in-Charge .
S & F in repairs desert cooler body of size 60x55x65 cm made out of GI sheet & water storage tank of size 65x55x20 cm deep made out of GI sheet including front grills & three side shutters duly fitted with wood pads 03 no's & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) all as directed by Engr-in-charge.
M & L for servicing of Split type/window type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 /407a) shall be measured and paid for separately
Replacement of following unserviceable item in split type AC :- a) Blade for condensing fan motor of capacity 1.5 /2.0 TR
b) Condensing fan motor of capacity 1.5/2.0 TR
S&F in repairs blower fan motor split type AC of1.5/2.0TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S & F in repairs starting capacitor, for split type AC of capacity1.5/2.0TR. Complete all as directed. Make : EPCOS /ASIAN /Sarada
S&F in repairs Rotary type Compressor (Sealed Unit) of split type air conditioner of capacity 1.5/2.0 TR, Single phase220 volt of existing make necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification complete to taking down old unserviceable compressor the entire satisfaction of Engr-in-charge.
S&F in repairs scroll type Compressor (Sealed Unit) of water cooler40/80 ltr capacity single 220 volt of existing make including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification testing complete to taking down old unserviceable compressor the entire satisfaction of Engr-in-charge.
Supply and filling of Refrigerant gas R 22/ R-134/ R-410(a) in company sealed cylinder of capacity all as directed by Engr-in-charge
S&F in repairs and replacement wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 4 KVA.
S & F in replacement of indoor unit 1.5 /2.0 TR capacity as per existing makes and sizes complete all as specified and directed by Engr -in- charge
S & F in repairs PCB Senser unit split AC indoor unit of Capacity 1.5 /2 TR suitable for , existing removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
Supply & fix in replacement of factory made vertical type load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified and directed. Note: Work includes cutting of wall as per DB size and requirement and making good to disturbed surfaces as per existing surface.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type in pvc conduit for continuous earth wire and connected to common earth dolly complete all as specified. Make-RR / Havells/ polycab Note :- Two run of 4 sqmm copper conductor cable,one run of 2.5sqmm copper cable and one run of PVC conduit shall be measured as one unit length
Disconncting,dismantling the existing LT panel Meter board of size 1500mmX1800mmX350mm,415 Volt,3 phase,4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to users DB after carry out the following repair works in panel
S & F in replacement of Din rail for MCB SPN 63 Amps
Cutting the rusted out portion of the LT panel board and Welding with new sheets of thickness 2 mm including necessary fabrication at site not exceeding 1sqmtr and necessary painting etc.
Replacement of view glass for meter compartment.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldgs. no & respective quarter number ., danger sign board etc.
Reconnecting the sub mains 25 sqmm single core copper cable to the MCB's and MCCB's terminal with the help of copper lugs and thimbles and tightening properly in such a way that no leakage current found during site inspection.
Disconnecting, dismantling the existing LT panel Meter board for LIFT of size 600mmX1400mmX300mm with angle frame 50mmX50mmX6mm ,415 Volt,3 phase,4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re fixing back including connecting up all connections, new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to users DB after carry out the following repair works in panel as directed by Engr-in-charge.
complete painting with two coats of enamel paint by spray painting machine of approved colour with writing/making of connection details including Bldgs. no & respective quarter number ., danger sign board etc.
Welding of rusted out sheets with new sheets of thickness 2 mm.(not exceeding 1sqmtr)
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc.
M & L in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25X4 mm galvanized iron strip.
Supply and fixing in replacement at the place of old SFUs, MCCB- 4 pole-415 volt of capacity 250 amp, breaking capacity not less than 25 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. all as specified and directed by Engr-in-Charge Make : Legrand cat part No 420219 or equivalent Make in Schneider/L&T
Disconnecting mains connection and taking out old sub main wiring single core 6/10 sqmm and one single core 2.5/4/6/10 sqmm aluminium conductor cable from the concealed conduit from the wall/ceiling and making good to the disturbed surface all as specified.
M&L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 6 sqmm complete drawn in new PVC conduit in surface wall and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly Make Havells cat No WHFFDN A1 6x 0 all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft. Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters & making good the disturbed surfaces including putty filling & oil bound emulsion painting complete.
M&L for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 10 sqmm complete drawn in new PVC fixed to wall conduit and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly Make Havells cat No WHFFDN B1010 all as specified and directed. Note (i) Electrician having proper safety rope with safety belt/strap during sub main wiring for fixing PVC conduit along the bldg. within the shaft . Note (ii) work includes chases cutting for laying of PVC conduit with ss clamp at every 0.60 meters & making good the disturbed surfaces including putty filling & oil bound emulsion painting complete
Disconnecting mains connection and taking out old distribution board 8/12 way SPN with 200 amp rated bus bar complete with MCB and making good to the disturbed surface all as specified.
S&F factory made sheet steel distribution boards, double door, SPN, 8 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
S&F in replacement MCBs 6-32 Amps, SP, 10 kA rupturing capacity 'C' curve and fixing in DBs all as specified
S&F in replacement MCBs 40-63 Amps, SPN, 10 kA rupturing capacity and 'C' curve fixing in DBs all as specified
S&F in replacement MCBs 6-32 Amps, SPN, 10 kA rupturing capacity and 'C' curve fixing in DBs all as specified
Material and labour for cleaning and painting to old steel surfaces of Desert cooler with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide primer including scraping/rubbing with wire brush on old surface of Desert cooler. complete all as specified and directed by engineer-in-Charge
S&F in replacement Desert Cooler fan motor capacity 1/5 HP, 1400 RPM single phase with fan blade and stand complete.
S & F in repairs Aluminium fan blade for fan motor of desert cooler
S&F in repairs capacitor 4 MFD for fan motors of desert coolers.
S&F in replacement PVC insulated and PVC sheathed cable copper conductor 3 core (superior quality) complete.
S&F in replacement PVC water distributor of 3 out lets with MS nuts & bolts complete
S&F in replacement PVC elbow suitable for desert cooler
S&F in replacement PVC pipe 15 mm dia for Desert Cooler Pump complete.
S&F in replacement water lift pump plastic body of 220-240 Volts AC Supply single phase complete all as directed by Engr- in-Charge .
S & F in repairs desert cooler body of size 60x55x65 cm made out of GI sheet & water storage tank of size 65x55x20 cm deep made out of GI sheet including front grills & three side shutters duly fitted with wood pads 03 no's & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) all as directed by Engr-in-charge.
Labour for checking and attending complaints of ductable split type ACs, water cooler Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required for replacement shall be measured and paid separately under respective items) Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Kashmir House . (b) The complaint should be attended on same day. (c)) If the complaint not attended/not completed on same day recovery will be done as follows:- (i) For first day Rs.200/- (ii) For second day Rs.300/- (iii) For next every day Rs.500/-
Servicing of package type AC 4 Ton capacity complete with blower motor dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
M&L for taking down existing unsv compressor and fixing in replacement new hermetically sealed compressor suitable for 4 Ton capacity package type refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge, Make: Kirloskar/Tecumsheh/Copeland/Danfoss/existing make AC's complete all as specified.
Supply & charging the gas refrigerant R-22/R 410 A or as existing No to package type AC's of capacity 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed.
M&L for taking down of unsv PCB and transporting it to authorized workshop for its repair complete along with necessary accessories like diodes, resistors, capacitors for PCB card suitable for package type AC's of capacity 4 Ton complete all as specified and as directed by Engr-in-Charge.
M&L for taking down existing unsv condensing coil from Deep freezers of any capacity and replacement by new Condenser coil as per existing capacity upto 500 Ltrs including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge.
Servicing of package type ice cube machine 140 Kg/24 hours (with inbuilt bin) capacity complete dismantling all parts and refixing after cleaning and replacement of defective parts, dismantling the cover of condensing coil carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water and dry properly including using air blower for cleaning air dust deposited on the equipment and re-fixing the same after repair complete all as specified. Note:- Spare parts shall be measured and paid separately.
S & F In repair/ replacement of PVC ice thickness probe including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of double fold water valve hydraulic type including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of ice cube machine drain valve industrial type size 15mm including taking down old unserviceable all as directed by Engr-in- Charge
S & F In repair/ replacement of ice cube machine spray arm for metal bobby including taking down old unserviceable all as directed by Engr-in- Charge
Supply & fix in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete and including cutting chases and making good to walls all as specified.
Supply fix in replacement of MCCB TPN 160 Amp, 36 kA micro processor energy released type with OLED display complete all as specified.
Supply & fix in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete and including cutting chases and making good to walls all as specified.
S & F In repair/ replacement of ice cube machine fibre timer size 15mm 220 volt single phase including taking down old unserviceable all as directed by Engr-in- Charge.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type in pvc conduit for continuous earth wire and connected to common earth dolly complete all as specified. Make-RR / Havells/ polycab Note :- Two run of 4 sqmm copper conductor cable,one run of 2.5sqmm copper cable and one run of PVC conduit shall be measured as one unit length
NEERU ELECTRICALS
SNOWY ENGINEERING INC
J B Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .