| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAdmitted-Finance | ₹3.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.5 Cr+₹1.1 Cr (30.3%)Admitted-Finance | ₹4.5 Cr+₹1.1 Cr (30.3%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical A 1 BLOCK A ASTHA APRTMENT BHOJUBEER NEAR CIRCUIT HOUSE VARANASI UTTAR PRADESH 221002 UDYAM UP 75 0008931 | VARANASI | UTTAR PRADESH | 221002 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s Aghoreshwar Kripa Construction Co. L1 | AMIT ENGINEERING CORPORATION L2 |
|---|---|---|---|---|---|
| 1.00Supply of following materials as per RESPO/PuVVNL norms at the work site. | |||||
| 1.01 | STP Pole (SP-70) 13 mtrs long | 65 | No | 44,000 ₹28,60,000 | 39,500 ₹25,67,500 Lowest |
| 1.02 | STP Pole (SP-55) 11 mtrs long | 202 | No. | 40,400 ₹81,60,800 | 26,500 ₹53,53,000 Lowest |
| 1.03 | PCC Pole 8.5 Mtrs Long | 268 | No | 6,000 ₹16,08,000 | 5,500 ₹14,74,000 Lowest |
| 1.04 | X-Arm M.S. Angle(65*65*6)mm V-Type 11KV | 429 | No | 2,800 ₹12,01,200 | 1,500 ₹6,43,500 Lowest |
| 1.05 | M.S.Channel (125*65*1300)mm T-Off | 38 | No | 1,600 ₹60,800 Lowest | 2,200 ₹83,600 |
| 1.06 | ACSR Dog Conductor | 78.2 | Km | 87,500 ₹68,42,500 Lowest | 1,10,000 ₹86,02,000 |
| 1.07 | 11KV Disc Insulator with fitting (Polymer) | 472 | No | 900 ₹4,24,800 | 800 ₹3,77,600 Lowest |
| 1.08 | Dropper Angle for 11KV line | 18 | No | 2,500 ₹45,000 Lowest | 2,500 ₹45,000 Lowest |
| 1.09 | 11KV Pin Insulator with Pin (Polymer) | 1,574 | No. | 500 ₹7,87,000 | 350 ₹5,50,900 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
1 Aug 2022, 5:00 pmClosed
se edc
sonbhadra
Jal Jivan Mision Electrification Work
2022_PVVNV_715874_1
54/edc(so)/2022-23
Open Tender
Electrical Works
Turn-key
90 days
sonbhadra
Pleased ref Tender Doc.
2 documents required · 2 mandatory
₹11,800
SE EDC SONEBHADRA Bank A/c No.089105000853
₹3.5 L
24 Aug 2022
19 Jul 2022
2 Aug 2022
19 Jul 2022
1 Aug 2022
19 Jul 2022
Amount
Supply of following materials as per RESPO/PuVVNL norms at the work site.
STP Pole (SP-70) 13 mtrs long
STP Pole (SP-55) 11 mtrs long
PCC Pole 8.5 Mtrs Long
X-Arm M.S. Angle(65*65*6)mm V-Type 11KV
M.S.Channel (125*65*1300)mm T-Off
ACSR Dog Conductor
11KV Disc Insulator with fitting (Polymer)
Dropper Angle for 11KV line
11KV Pin Insulator with Pin (Polymer)
Stay Complet ( Stay rod 16*1800mm, Stay wire 5 kg, Stay clamp with bolt & nut )
Earthing Complete (M.S. Earthing Rod 16x1800 mm 6 SWG earthing wire)
M.S. Top Channel (100x50x2240 mm)
11KV 3Core 185sqmm XLPE Cable
11KV 3Core 185sqmm Outdoor Termination kit
11KV 3Core 185sqmm Outdoor Straight Through
11 KV VCB O/G Feeder CTR 200/100/5A 250 MVA
11 KV TPMO With all accessories
11 KV Fues Set (drop out) With Clamps
M.S. Cross Brasing Angle 50x50x6 mm, 4.5 kg/m
G.I. Wire 6SWG & 10SWG for gaurding and lacing
M.S. GAURDING ANGLE (65x65x6 mm, 1.6 m long) for gurding at single support with clamp
X-Arm holding clamp with nut & bolt
Danger Board with nut &bolt
F-Bracket with nut &bolt
Barbed wire
T-Off,Top,Dropper Clamp with nut&bolt
PG Clamp for DOG
G.I.Pipe 6"Dia
Various type nut &bolts
Stone Pad(300*300*75)mm
Work of following materials as per RESPO/PuVVNL norms at the work site.
Erection of single support ST/PCC pole for construction of 11 KV line including digging of pit, fitting of all accessories, back filling of earth & others required work.
Grouting of pole with 1:4:8 ratio of cement sand & brick ballast as per RESPO norms. (cement sand & brick ballast wil be supplied by the constractor on his own his own cost)
Grouting of stay sets including digging of pit with 1:4:8 ratio of cement sand & brick ballast as per RESPO norms, fixing binding and nuzzling of stay wire. (cement sand & brick ballast wil be supplied by the constractor on his own his own cost)
Earthing of Poles
Installation/Carriage of 11 KV Pilfer proof metering cubicle inside meter room, by fixing rag bolts after checking alignment with trench & conneting incomming & outgoing cable in the CT chamber /
Mounting/Carriage of CT/PT Unit on double pole with using 02 no. S/S Base (M.S. Angle).
Stringing & sagging of 3 phase 11 KV line upto proper sag including laying of ACSR DOG Conductor, binding with insulators & jumpering.
Erection of Sectional Double Pole Structure of STP including fitting of all accessories & other required works.
Drill/cut of stone for erection of Pole/Stay in hilly area
Gaurding of 11 KV line as per RESPO norms
11 KV 3x185 sq mm XLPE Cable Laying Digging of trench size 0.75x0.75 mtr & putting layer of sand of bottam & laying of cable covering the trench from sites & top by laying bricks finely cover the same by earth.
11 KV 3x185 sq mm XLPE Cable Laying of 11 KV XLPE Cable under G.I. Pipe 6 dia by catting pucca/bitamer road & road restoration
Making of joint cable box size 3x185 mm2 11 KV indoor & outdoor type
Making of joint cable box size 3x185 mm2 11 KV straight through kit
Installation of 11 KV VCB O/G Feeder CTR 200/100/5A 250 MVA
Installation of 11 KV TPMO With Clamp
Installation of 11 KV Fuse Set With Clamp
AMIT ENGINEERING CORPORATION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .