Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹35.7 L+₹17,084.25 (0.48%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹83,640
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
PROVN OF HIGH MAST POLE 16 M WITH 24 LIGHTS EACH POLE 08 NOS AT AUNDH PROVN OF 30 GEYSERS 25 LTRS FOR JCOs AND OTM ACCN AT KLP HQ 41 ARTY BDE PROVN OF GUARD ROOM NEAR BN MAG OF 24 MARATA LI AND PROVN OF ATT TOILET AT COY OFFICE AT MH UNDER GE MH AND
2024_MES_662805_1
8558/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MH AND RH KHADKI
₹83,640
3 Nov 2024
28 Jun 2024
6 Sept 2024
28 Jun 2024
3 Sept 2024
12 Jul 2024
28 Jun 2024 - 19 Jul 2024
Amount
Excavating in post holes (or similar Holes ) each not exc 0.5 cum, getting out in hard/ dense soil, returning, filling in & ramming earth in layers not exc 25 cm thick watering & removing surplus soil to a dist not exc 50 m & making good surface all as specified and directed.
M&L for cement concrete 1:3:6, type C-2 using 40mm graded stone aggregate as in foundation, filling, locking of paver block tiles and mass concrete
M&L Rolled mild steel for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W(Gde-E- 250) quality-A
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmen Fe 410 -W(Gde-E- 250) quality-A
M & L for two coats of synthetic enamel paints over a coats of red oxide primer including prepration of new steel surfaces of any description over 10 cm in width or girth not otherwise described.
S & F Pre painted galvanised aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F framed work as in doors or gates of angle or other section with gusset plate, rails, braces etc, complete drill for fixing steel sheeting or other covering etc including necessary welding, riveting, nut bolting etc all complete conforming to Gde Fe-410-S all as specified and directed.
Surface dressing n exc 15Cm deep in hard/dence soil.
Excavating in trenches, soft/loose soil n. exc 1.5m wide and n. exc1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil.
Excavation in trenches for taking out/laying of pipes line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in hard dense soil complete and all as specified
M&L for Cement concrete type D2 1:4:8 (40mm graded aggregate)in foundations filling and mass concrete.
M&L for precast cement concrete, block type C-1, 1:3:6 (20mm graded aggregate ) masonary with solid blocks, exc , 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M & L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces with using WPC on top layer complete all as specified and directed.
Supply only integral water proofing compound .
M&L for preparing new plastered surfaces of walls and applying two coats of Exterior emulsion weatherproof paint over a coat of primer.
M&L for sand filling under floors or in foundation including watering and consolidation.
Hardcore of gauge exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/ rammed to a true surface.
M & L 75mm thick cement concrete type D-2, 1:4:8 ( 40mm graded aggregate ) as in sub base to receive top floor.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick in CM (1:6) Screed bed or bedding layer of mortar for laying floor finishes all as specified and directed.
M&L for non-skid ceramic coloured tiles (300 x 300 mm) x 7mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6.
M&L Coloured Glazed ceramic tiles (350 x 250 x 7 mm or 450 x 300 x 7 mm thick) on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection/path finishing cement concrete surface even and smooth without using extra cement.
S & F Vitreous China Squatting pan Orissa pattern long pan, size 580 mmX440mm white with `P' or `S' trap, front or back inlet and foot rests any pattern including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including concrete complete including making good to floor.
M&L 100mm dia CI Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4).
S&F vitreous china wash basin white, flat back of size 450 x 300mm, excluding taps, waste chain & plug & porcelein stopper but including brackets, cutting for and pinning in ends of brackets all as directed.
S & F Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union
S& F Soap dish CP size 160 x 160 x 90 mm,fixed to plugs with chromium plated brass screws complete all specified and directed.
S&F tubular towel rail 20mm dia, D type 60cm long between flanges brass chromium plated all as specified and directed.
S & F PVC connections 15 mm size with PTMT nuts of 600 mm long
S & F PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed.
Cutting chases, pinning in PCC block/brick walls, making good to facing where required and pointing in cement mortar (1:3) and making good , cutting n.exc 10cm girth , all as specified and directed.
S & F 15 mm bore galvanised steel tubes medium grade with all connections and fixed to walls and ceiling or laid in floors complete.
S & F 20 mm bore galvanised steel tubes medium grade with all connections and fixed to walls and ceiling or laid in floors complete.
S & F 25 mm bore galvanised steel tubes medium grade with all connections and fixed to walls and ceiling or laid in floors complete.
S & F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed - bore dia of pipe 15 mm but fancy type with long shank and cup ( concealed type) complete all as specified and directed by Engr-in-Charge.
S & F angle stop valves fancy type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed - bore dia of pipe 15 mm.
S&F Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe.
S & F 20mm dia bore Gun metal, globe or gate valves with Iron wheel head, screwed both ends for Iron pipes and fixed.
S&F 15mm dia fancy type Bib taps, cast copper alloy CP with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F rotational moulded polyethylene water storage tanks of capacity 500 ltr hoisted and fixed in position including 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed all as specified and directed.
S&F PVC (SWR) pipes 110mm dia ,single socketed in any length with rubber ring joints laid in trenches or floor complete all as directed.
S&F PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed and laid in trenches or floor all as directed.
S&F PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) bends any radius,for 110mm dia pipe.
S&F PVC (SWR) bends any radius, 75mm dia pipe.
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose/hard/dense soil complete and all as specified.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. Complete and all as specified.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi?nium framework with screws on anodised aluminium snap grid frame work for false ceiling the size of grid should be 606mmx605mm including preparation of surface and applying three coats of white wash complete all as specified and directed by Engr-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding/ complete and removing rubbish off the premises complete all as specified and directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6all as specified and directed at any height
M&L for rendering of internal surfaces 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement ) all as specified and directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6 all as specified and directed.
S & F Galvanised steel water tubing medium grade to walls and ceiling or laying in floors of the following size
(a) 15 mm bore
(b) 20 mm bore
M&L for waterproofing treatment to RCC Base slab as specified below. Make: PIDILITE or equivalent.
(a) Clean the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc.
b) M&L for Making hole and fix 12mm dia GI Nozzle @0.5 mtr c/c on the entire area of sunken portions and applying chemical injection grouting through the nozzles with cement slurry admixture with dr fixit bath seal grouting or other equivalent with pressure pump in 40 PSI.seal off the nozzleand cutting the same after grout has set as specified and directed by Engr-in-Charge
(c) Form angle fillet of size 40 mm x 40 mm thick cement sand mortar (1:3) admixed with diluted ("Dr Fixit" Pidicrete URP" or equivalent)1:3
(d) Wet the surfaces with water to make it saturated surface dry condition
(e) Sanitary pipes entering through walls and floor shall be sealed with " Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Gruot" or eqvt . Nahani traps , etc to be fitted securely and the gaps around it to grouted in the same manner.
(f) Ponding test for water leakage will be carried as per IS 3370 part 1 instructing
(g) Applying 20 mm thick plaster in C:M 1:3 mixed with water proofing compound 3% by weight of Cement or as per manufacturer instruction
(h) Plumbing works to be providedaccording to proper level&slope seal off the pipesand back fill the gap properly and provide 40mm Outer dia UPVC spout pipe at the lowest point with 300mm projection beyond the outer face of the wall.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
S&F in Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, seat cover complete , all as specified and directed.
Supply and fix in repairs PVC flushing cistern 10 ltrs capacity valveless, syphonic action type including inlet, ball valve, float, handle and brackets etc all as specified and directed
S&F in repairs wash hand basin vitreous china white flat back of size 550 x 400 mm including waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms)PVC flexible waste pipe 32 mm bore 450 mm long PVC connection pipe, chromium plated brass waste fittings 32 mm complete all as directed
Supply and fix PVC waste pipes 40 mm dia with necessary fittings including taking/existing 40 mm PVC waste pipes.
S & F in repair waste coupling 32 mm dia of PTMT (half or full threaded) minium weight 45 gram.
Supply & fix 15mm bore angular Stop valves, cast copper alloy, fency type, chromium plated with long or short shank and cup ( concealed type) screwed down high pressure , screwed both ends for iron pipe or for unions.
S&F in repairs Health faucet brass chromium plated with 8mm Dia, 1 Meter Long Flexible Tube chromium finish spring type & Wall Hook fixing to 15 mm bore of pipe all as specified and directed.
Supply and fixing in repairs CP soap dish holder complete all as specified and directed.
S & Fin repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 110 mm with PVC clamps and saddles
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm
All as per item No. 67 above but bore of pipe 110 mm with access door
S & F in repairs PVC (SWR) branch piece double (Double Y) equal or unequal with access door bore of pipe 75 mm
All as per item No. 69 but bore of pipe 110 mm
S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms, all as specified and directed.
S&F in pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes 15mm dia all as specified and directed
S&F in Fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed by Engr-in-Charge
S&F of PVC connections 15mm size with brass nut on both end washers of length 450mm all as specified
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise N.exc 100 sq.cm all as specified and directed
M&L Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L snap grid ceiling with 18 mm thick semi - perforated edge 60x60cm in ceiling board over GI grid prelude XL 24 mm grid main runner height 37mm and secondary runner height 30mm including 2.6mm/2.8mm GI wire suspenders of suitable length as per manufacturers instructions all as specified and directed .
S&F aluminium louvered ventilators of section size 100mmx25mmx1.50mm including frosted glass fixed in half portion & adjustable type louvers in another half and stainless steel wire mesh fixed type on outside frame etc. including taking down existing steel ventilator all as directed by Engr-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing all as specified and directed.
S&F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain coour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panellinn of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed.
S & F stainless steel Butt hinges 75 mm long, medium weight, cold rolled steel.
S & F in 125 mm size extruded aluminium alloy handles, fabricated type anodised.
S & F in Aluminium, anodised, barrel tower bolts of extruded section 125mm long complete all as specified and directed.
S & F Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed & fixed length of bolt 250 mm all as directed.
M & L applying two coats of Oil Bound distemper over a coat of primer ncluding surface preparation all as specified and directed Engineer-In-Charge
M & L applying three coats of white wash to newly plastered surface of wall including preparation.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engr - in - Charge.
M&L for riddle earth including spreading, levelling and hand punning to underground cable in trench all as specified and directed. Note : Punned thickness shall only be measured and paid.
M&L for brick protection with Class "B" Bricks all as specified and directed.
Supply only GI tubing light grade 40mm bore, ISI marked, for cable protection in trenches/ walls all as specified and as directed.
Supply & installation of Galvanized steel high mast lighting system of 16 meter (Moterised) in two section, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm, with 2/3 wire rope Moterised system and its Motorised accessories. System is suitable for loading 08 Nos, 200Watt LED flood lights and Anchor plate 445PCD 6 Holes, Template 445 PCD 6 Hole, Foundation Bolt M30x850mm Straight -06 Nos, complete all as specified directed by Engr in Charge Note:Rates are inclusive of cost of foundation In HM light, cost of luminaires is to be added separately.
S & F in repairs LED flood light 200W, made up of pressure die cast aluminium housing with toughened glass and high power LEDs , IP 66, complete & wired with all accessoires. Make: Halonix/Crompton/Havells
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed
Supply installation , commissioning and testing of Avaitation obstruction light Insta power red painted housing , Red coloured polycarbonate dome and cast aluminium housing with all accessories complete all as specified and directed.cat No SZPALMX-2 Make Shakti fixtures pvt ltd/Bajaj/CG/C&S.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The bottom of panel shall have minimum 60cm height from existing ground / floor level. (vii) The panel circuit design shall be as per recommendation of OEM of High Mast and approved by GE.
i) Incomer
a) MCCB four pole 25 KA rapturing capacity 50Amps Ics= 100% of Icu adjustable thermal magnetic setting including connection with bus bar - 01 Nos (as incomer)
ii) Out going
a) MCB TPN, 10KA, 32 Amps, - 03 Nos (01 x for High mast light , 01x for winch motor , 01 x spare )
b) MCB SP, 10KA, 16Amps, for Aviation light - 01 Nos
e) LED type RYB phase indicator lamp with back up HRC fuse - 01 Set
(f) Automatic timer switich with suitable size of contactor-01 set - 01 Nos
(g) Forward and reverse switch for winch control of rising/ lowering the luminaries.
M & L for earthing complete with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 3.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical palte No 3 of SSR part-I, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. Note: Rate for achieving required depth by compressor machine/breaker if required is deemed included in item unit rate
Supply and fix (Geyser) Water heater storage type of capacity 25 Liters vertical type wall mounted including 15/16 Amps plug top with suitable wall supports and for manual operation, digital temperature display, feather touch buttons, built in thermostat, auto shut off, powder coated single line weld container with PUF insulation, heating element capacity of 2 KW, voltage rating 230 Volt, frequency 50 Hz, 5 star rated with and including steel braided connecting hoses of required length for Hot and cold water pipe, connecting to CPVC and GI pipe all as specified and directed by Engr-in-Charge. Make: Havells/Jaquar/Crompton/Bajaj. Note :- (i) The rates are inclusive of all the minor spares (Fasteners, Nut bolts washers etc) required for making the geyser fully functional. (ii) The rates are inclusive of charges of OEM of the geyer who has to visit the site and brief the user about the functioning of the water Heater.
Supply and fix Hot water pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure with lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed all as specified and directed by Engr-in-Charge. Notes:- (i) Hot water piller taps for OTM -40 Nos and for JCO living Accn -10 Nos. (ii) The rates are inclusive of 20 x 15 mm reducers and sockets wherever required.
Supply and fix Stop Valves , cast copper alloy, screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed of size 15 mm all as specified and directed by Engr-in-Charge.
M&L for point wiring in PVC conduit complete using 1.5 Sqmm PVC insulated unsheathed (FRLS) copper conductor, stranded cable upto and incl working voltage 1100 volts grade, ISI marked, PVC concealed conduit medium grade , ISI marked incl fittings such as bend,tee,junction boxes elbows etc incl pressed steel terminal sunken boxes of required size and thickness not less than 1.2mm thick covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly including chases cutting and making good surfaces matched with existing complete all as specified and directed.
(a) One light point controlled by one switch
(b) One fan point controlled by one switch
(c) One socket outlet point 5/6 Amps on independent board.
(d) One socket outlet point 5/6 Amps on the same board.
All as per item No 101 above but for point wiring for power point with 2.5 Sqmm PVC insulated copper (FRLS) cable 1100 Volt grade drawn through and including conduit medium grade ISI marked /medium grade concealed conduit ISI marked as required at site along with accessories with 2.5 Sq mm PVC copper earth wire all as specified and directed by Engr - in - Charge.
M&L Switch piano fancy type single pole, one way 5 amps all as specified and directed by Engr - in - Charge.
M&L for switch socket combination 3 pin , 16 Amps single pole one way all as specified and directed by Engr - in - Charge.
S & F socket outlet 5 pin 6 Amps shuttered flush type all as specified and directed.
M&L for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked all as specified and directed by Engr - in - Charge.
S & F for new ceiling fan, complete with blades, down rods, electronic regulator including remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply & fix LED tube light along with fixture, 22 W all as specified and directed by Engr - in - Charge.
M&L for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way double door with 200 Amps rated copper bus bar neutral bar ,earth bar IP 43 protection, single pole and neutral 250 volts ,flush to wall complete all as specified and directed including taking down old one Make : Legrand/ L&T (Hager) /Schneider (Multiq) all as specified and directed by Engr - in - Charge.
M&L for Circuit breaker single pole & neutral 240 volt C curve 10 KA 32 Amps capacity IP 20 complete all as specified and directed Make : Legrand/L&T (Hager) /Schneider (Multiq)
M&L for Circuit breaker single pole, 6Amp 240 volt B curve 6 KA, IP 20 complete all as specified and directed by Engr - in - Charge. Make : Legrand/L&T (Hager) /Schneider (Multiq)
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose/hard/dense soil complete and all as specified.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. Complete and all as specified.
M&L for riddle earth including spreading, levelling and hand punning to underground cable in trench all as specified and directed. Note : Punned thickness shall only be measured and paid.
M&L for brick protection with Class "B" Bricks all complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engr - in - Charge.
S&F for Modular Switch, 1 module single pole one way, and 6 amp complete ISI mark complete all as specified and directed by Engr-in-Charge.
S&F in Switch 16 Amps Modular one Way all as directed by engr- in- charge.
S&F in scoket 16 Amps Modular Flush type, all as directed by engr- in- charge.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed by Engr-in-Charge.
S & F PVC ceiling rose surface type three terminals type all as specified and directed by Engr-in-Charge.
S & F for sheet metal enclosure MCB SPN DB 4 Way with 200 Amps rated copper bus bar 240 volts 50 Hz AC Supply Double door with magnitic locking system complete all as specified and as directed.
S&F MCB SPN 10 to 32 Amps B curve 10 kA 240 Volts AC Supply
S&F MCB SP 5 to 32 amps, B curve 10 kA 240 Volts AC Supply
M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge.. Note: Two core cable and earth wire and conduit shall be measured as one length.
S&F surface and wall mounted LED T5 integrated batten Batten with integrated electronic driver energy efficient 10W LED (Two feet) decorative with working voltage 140-260V AC, system Lumen output min 1100 Lumen in 10 W in 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV Surge protection in Built LED complete in all respect.
S & F in wall mounted extruded aluminium housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4' long) lumen 2000 - 3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connecto to ceiling rose as directed by Engr-in-charge.
Supply and fix Exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete ISI mark complete all as specified and directed by Engr-in-Charge.
SKS Electricals (BID ID -3067430)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .