XEN Electrical division No. 1 Shimla-9
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
CO Indoor Stadium at Thodo Ground Solan Tehsil Distt Solan HP SH Providing Fire Alarm therein
2021_PWD_49930_1
Electrical Div.No1PWD Shimla 2021-22-1644-49 dt.
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA KASUMPTI -9
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹31,600
22 May 2025
15 Jul 2021
22 Jul 2021
15 Jul 2021
21 Jul 2021
15 Jul 2021
Amount
Supply Installation and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable 2 Loop module and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of Active and networkable repeater panel/Mimick Panel with 600 character 7" LCD display/ mimic panel etc. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of addressable multisensordetector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of beam detector that should operates over distances between 32 ft and 300 ft (107 m) having Automatic range adjustment, signal synchronization and contamination adjustment. Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of addessable Double ACTION manual call point & necessary fixing arrangements with key complete as required. MCP should have IP52 or better protection rating Shall be EN54 -Vds/UL-FM Certification.Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of Addressable Sounder with sound pressure 90 dB(A), Sounder should have IP40 or better protection rating. Shall be EN54 -Vds/UL-FM Certification.Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input and 1 output which shall monitor normally open or normally closed contacts. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module. Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doors etc.. Shall be EN54 -Vds/UL-FM Certification. Make: Bosch /Notyfier/ Siemens Fire finder/Honeywell.
Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener complete the work upto the entire satisfaction of Engineer In Charge. Make: PES /HEINRICH/ OMEX/Agni/Falcon
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2x1.5 Sq. mm.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm. dia
Vowels Technology and Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .