Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.9 LAccepted-AOC 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | 1 | Accepted-AOC As per Tender firm is L1 | |
| 2 | 2₹7.7 L+₹80,420 (11.7%)Rejected-Finance | 2 | Rejected-Finance as per NIT | |
| 3 | 3₹7.7 L+₹87,107.64 (12.7%)Rejected-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | 3 | Rejected-Finance as per NIT | |
| 4 | 4₹7.8 L+₹96,410 (14.0%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 4 | Rejected-Finance as per NIT | |
| 5 | 5₹7.9 L+₹1.0 L (14.7%)Rejected-Finance 00 BRAHMNAGAR KAMHARI ROAD ROBERTSGANJ SONBHADRA UTTAR PRADESH 231216 | SONBHADRA | UTTAR PRADESH | 231216 | 5 | Rejected-Finance as per NIT |
Tender Value
₹9.0 L
EMD Value
₹17,950
Closing Date
30 Jun 2023, 3:00 pmClosed
SUDHIR KUMAR
EEE/WZ
Renovation/Improvement of Electrical Wiring and fitting fans and compound lights at MnCW Center Pocket-C Janta Flats Hastsal in Ward no. 108 Hastsal under West Zone.
2023_MCD_158718_7
EE/ELECT/WESTZONE2023-24/05
Open Tender
Electrical Works
Works
30 days
RAJOURI GARDEN
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹17,950
13 Sept 2023
24 Jun 2023
30 Jun 2023
24 Jun 2023
30 Jun 2023
24 Jun 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 × 2.5 sq. mm + 1 × 2.5 sq. mm earth wire
2 × 4 sq. mm + 1 × 4 sq. mm earth wire
4 × 2.5 sq. mm + 2 × 2.5 sq. mm earth wire
4 × 4 sq. mm + 2 × 4 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface /recessed steel / PVC conduit as required.
1 x 1.5 sq. mm
2 x 2.5 sq. mm
2 x 4 sq. mm
3 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 36 KA,FPMCCB
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable for working voltage upto 1.1 KV grade Conforming to IS 7098 of following Sizes
2 x 6 sq mm
4 x 25 sq mm
SITC of wall mounted Fan 400mm sweep rated voltage 220-230 AC rated frequency 50Hz speed 1280-1350rpm with desire color.
SITC of On - line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 5 KVA
S.I.T.C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following (a) Total system wattage 20 watt +/-5% (b) Luminous efficacy>=95 Lm/w (c) Power Factor>=0.95
SITC of 100 W LED Flood light luminaire fitted with lens, made of presure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP-66 protection (a) Total system wattage= 100 watt +/-5% (b) Luminaire efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class-IP-66
P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of outer dimension 230mm X 170mm X105mm & inner dimension 200X140X95 mm complete with suitable arrangment for fixing of 1 no.s of 6 to 32 Amp single pole MCB (MCB exculded) with neutral link duly shorting on DIN channel with 2 nos. of clamps with SS back plate of suitalbe size with Danger monogram & SDMC property printed on teh cover etc as reqd.
Supply of 1200mm sweep 50 Watt, Energy saver ISI marked BEE 5 Star rating AC Ceiling fan suitable for 230V, 50 hertz AC supply without regulator with blades, downrod etc. complete as required.
Supply of 12'' (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
supply, installation, testing and commissioning of Single/three phase Mono Block P/Set complete with all accessories workable on 240/415 volt. 50 Hz AC supply
1HP (0.75 KW ) Single Phase Pump Set Head frame 12.5 mt upto 25 mt Suction and delivery 25x25
Providing and fixing 4.5 kg CO2 typefire extinguisher squeeze grip type, trolley wheel as well mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required
Supplying , lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc as required.
Single phase 1.5 HP having dischargeof 72 LPM Approx at 49 M Head
SITC of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay MCB , condenser, voltmeter, ammeter and indication lamp etc including connection etc. as reqd.
1.5 HP (Single Phase)
P&F of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd.
3 x2.5 sq.mm
Supply, installation, Testing and commissioning of 1.5 Ton, 5 Star rated Inverter Split Air conditioner with rotary compressor (R-32 Refrigerant) having copper condenser complete with outdoor unit as required.
Supply, installation Testing and commissioning of 2 TR, 2 Star/3 Star Window air conditioner having copper condenser coil rotary compressor and R32/better refrigerant.
S/I/T/C of stand for split AC
S/I/T/C of copper pipe for split AC
S/I/T/C of Drain pipe for split AC
S/I/T/C of 3 core, 4 Sqmm Electrical wirefor Air conditioner
SHRIRAM SHARMA
DELIGHT TRADING COMPANY
SRI BALAJI ELECTRICALS
S.G. ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .