Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHAMBERS DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 400088 | MUMBAI | MUMBAI | MAHARASHTRA | 400088 | L1 | Admitted-Finance | |
| 2 | L2₹1.6 Cr+₹20.6 L (14.8%)Admitted-Finance UNIT NO 117 IDEAL DEVAJI KESHAVAJI INDUSTRIAL ESTATE W T PATIL MARG CHEMBUR MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical DIPENDRA PATIL E 66 MIDC AREA AJANTHA ROAD 94222 JALGAON MAHARASHTRA 425003 | JALGAON | MAHARASHTRA | 425003 | - | Rejected-Technical Not meeting NIT Criteria and not admitted for Part-B opening |
| Sl No | Description | Qty | Unit | Aswathi Power Controls L2 | Arathi Electricals L1 |
|---|---|---|---|---|---|
| 1.00 | Maintenance of SMPS based Float and Float Cum Boost battery chargers as per Clause 1 of Specification | 60 | Each | 55,000 ₹33,00,000 | 42,000 ₹25,20,000 Lowest |
| 2.00 | Maintenance of SMPS based Float Cum Boost battery chargers as per Clause 2 of Specification | 12 | Each | 57,000 ₹6,84,000 | 42,000 ₹5,04,000 Lowest |
| 3.00 | Maintenance of AC/DC SMPS based converter as per Clause 3 of Specification | 12 | Each | 54,000 ₹6,48,000 | 42,000 ₹5,04,000 Lowest |
| 4.00 | Maintenance of Thyristor based battery chargers as per Clause 4 of specification. SITC of following items required for maintenance of battery chargers | 32 | Each | 25,000 ₹8,00,000 | 17,000 ₹5,44,000 Lowest |
| 5.00Maintenance of Battery Banks as per Clause 5 of specification | |||||
| 5.10 | 225AH, 110V Battery Banks (YKP-19) | 1 | Each | 3,20,000 ₹3,20,000 | 2,90,000 ₹2,90,000 Lowest |
| 5.20 | 200AH, 110V Battery Bank (YKP-17) | 3 | Each | 2,95,000 ₹8,85,000 | 2,70,000 ₹8,10,000 Lowest |
| 5.30 | 100AH, 110V Battery Bank (YKP-9) | 10 | Each | 2,45,000 ₹24,50,000 | 2,20,000 ₹22,00,000 Lowest |
| 6.00 | Maintenance of VRLA as per Clause 6 of Specification | 13 | Each | 30,000 ₹3,90,000 | 20,000 ₹2,60,000 Lowest |
| 7.00 | SITC of 110V, 100AH Lead Acid battery bank along with standard accessories as per clause 7 of specification | 3 | SET | 7,50,000 ₹22,50,000 | 6,90,000 ₹20,70,000 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.9 L
Closing Date
6 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer and Director, ESG
ESG Office
Upgradation and Maintenance of Battery Chargers and Battery Banks of various substations inside BARC, Trombay, Mumbai-400085.
2026_BARC_922357_1
BARC/TSD/ET/20/2026-2027
Open Tender
Electrical Works
Item Rate
730 days
BARC, Trombay
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3.9 L
Conference Room, 2nd FL, TSD
5 Nov 2026
18 Aug 2026
8 Oct 2026
18 Aug 2026
6 Oct 2026
18 Aug 2026
18 Aug 2026 - 28 Aug 2026
24 Aug 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance of SMPS based Float and Float Cum Boost battery chargers as per Clause 1 of Specification | 60 | Each | - | - |
| 2 | Maintenance of SMPS based Float Cum Boost battery chargers as per Clause 2 of Specification | 12 | Each | - | - |
| 3 | Maintenance of AC/DC SMPS based converter as per Clause 3 of Specification | 12 | Each | - | - |
| 4 | Maintenance of Thyristor based battery chargers as per Clause 4 of specification. SITC of following items required for maintenance of battery chargers | 32 | Each | - | - |
| 5Maintenance of Battery Banks as per Clause 5 of specification | |||||
| 5.1 | 225AH, 110V Battery Banks (YKP-19) | 1 | Each | - | - |
| 5.2 | 200AH, 110V Battery Bank (YKP-17) | 3 | Each | - | - |
| 5.3 | 100AH, 110V Battery Bank (YKP-9) | 10 | Each | - | - |
| 6 | Maintenance of VRLA as per Clause 6 of Specification | 13 | Each | - | - |
| 7 | SITC of 110V, 100AH Lead Acid battery bank along with standard accessories as per clause 7 of specification | 3 | SET | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 0.43 MB
Specification.pdf
Tender Documents • 0.18 MB
Man_Power_Recovery_sheet_BARC_TSD_ET_20_2026_2027.pdf
Tender Documents • 0.50 MB
TECHNICAL_BID_BARC_TSD_ET_20_2026_2027.xls
Tender Documents • 0.27 MB
ScheduleA.pdf
Tender Documents • 0.76 MB
BOQ_969257.xls
BOQ • 0.22 MB
NITENGLISH.pdf
Tender Documents • 0.28 MB
NITHINDI.pdf
Tender Documents • 0.42 MB
Tender_document.pdf
Tender Documents • 1.33 MB
ProformaofSchedule.pdf
Tender Documents • 0.63 MB
Corrigendum.pdf
PDF • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .