Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L1 | Accepted-AOC ok | |
| 2 | L2₹7.9 L+₹28,833 (3.80%)Rejected-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L2 | Rejected-AOC ok |
Tender Value
₹7.4 L
EMD Value
₹14,800
Closing Date
23 Dec 2019, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
REPAIR / MAINTENANCE OF COOLING APPLIANCES, STREET LIGHTS AND CERTAIN MISCELLANEOUS WORKS AT SONEGAON, NAGPUR
2019_MES_299874_1
8319/E8
Open Tender
Civil Works
Item Rate
180 days
Sonegaon
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon, Nagpur
₹14,800
Yes
10 Jan 2020
21 Nov 2019
24 Dec 2019
22 Nov 2019
23 Dec 2019
4 Dec 2019
22 Nov 2019 - 3 Dec 2019
Amount
S&F in repairs starting capacitor of cap 80/100 MFD 440 Volts Air Conditioner & fixing in position testing etc complete all as specified and directed.
S & F in repairs running capacitor of cap 36 MFD 440 V AC & fixing in position testing etc all as specified and directed.
S& F in repairs over load relay suitable for AC split 1.5 ton & fixing in position & testing etc all as specified and directed.
S & F in repairs thermostat suitable for AC split type 1.5 ton fixing in position etc all as specified and directed.
S & F in repairs thermostat suitable for AC split type 2 ton fixing in position etc all as specified and directed.
M & L for refrigerant gas charging with R-22 suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position all as specified and directed.
S & F in repairs sealed/unit compressor with full charging of gas F-12/R-22 factory winded ( Make : Kirloskar/Shriram , Bluestar) suitable for AC 1.5 /2Ton split type or equivalent including transporting to civil work shop & bring back at site & fixed in position & testing etc all as specified and directed.
S & F fan motor 230 V suitable for AC 1.5 ton split type all as specified and directed (any capacity)
S & F fan motor 230 V suitable for AC 2 ton split type all as specified and directed ( any capacity )
S & F in repairs filter element suitable for AC 1.5 ton Split type of any make all as specified and directed.
S & F in repairs filter element suitable for AC 2 ton Split type of any make all as specified and directed.
S & F in repairs blower unit for A/C 1.5 ton, 2 Ton of split type all as specified and directed.
S& F in repairs remote control suitable for AC split type cap 1.5 ton, 2 ton & 3 ton of split type all as specified and directed.
S&F in repair PCB circuits for ACs 1.5, 2 TR all as specified and directed.
S&F in repair PCB circuits for inverter base AC cap1.5/2 TR including inner & outer unit all as specified and directed.
Disconnecting outer & inner unit of Air-conditioning unit of any capacity including cutting of copper tubes including shifting of outer unit from roof of the building with provision of angle iron anchor pickets made out of 25mmX25mmX5mm angle iron with suitable size of MS plate with installation of outer & inner unit of AC with the suitable space for further maintenance including necessary gas charging / topping up R-22 with soldering of copper tubes all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/R134 factory winded suitable for refrigerator 185 ltrs capacity of any make carrying out in civil work shop & bring back at site fixing & testing complete all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for refrigerator cap 165/250/310 Ltrs including cutting of copper tubes soldering & fixing in position all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for deep freezer of various capacity including cutting of copper tubes soldering & fixing in position all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/R134 factory winded of cap 40/60/80 ( Make Kirloskar / Shriram or equivalent) Model 444, 512, 2612 or equivalent carrying out in civil work shop & bring back at site & testing for water cooler all as specified and directed.
S & F in repairs fan motor 230V single phase 1440 RPM suitable for water cooler 40/60/80 Ltrs and fixing in position etc all as specified and directed.
S&F in repairs starting capacitor 80/100 MFD 440- V suitable for water cooler any cap and fixing in position testing etc all as specified and directed.
S & F in repairs capacitor 36 MFD 440 V suitable for water cooler any cap fixing in position testing etc all as specified and directed.
S&F in repairs over load relay suitable for water cooler fixing in position testing etc all as specified
S & F in repairs 15mm ball valves high pressure with polythene float valve and fly nuts complete screwed for iron pipe & fixed for water cooler any capacity all as specified and directed.
S & F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes for union & fixed of size 15 mm bore all as specified and directed.
M & L for refrigerant gas charging with R-12, R-22 or equivalent for water cooler cap of 40/60/80 Ltrs cap including cutting of copper tubing & soldering all as specified and directed.
Taking out old unserviceable thermostat from water cooler, supply and fix thermostat complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 5 KVA capacity complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 2 KVA capacity complete all as specified and directed.
Taking out old unserviceable volt meter/ amp meter. Supply & fix volt meter/ amp meter for single phase voltage stabilizer all as specified and directed.
M &L for rewinding of fan motor any make any size of desert cooler with super enameled copper wire using with suitable gauge including materials such as insulating paper, varnishing, heating/baking and reassembling testing complete all as specified and directed.
S & F in repair of fan motor including cutting dismantling from desert cooler any size of desert as per site all as specified and directed.
S & F in repairs vertical pump for desert cooler with GI clamps suitable Upto 5 feet height discharge coolers etc all as specified and directed.
S & F in repairs capacitor 4 MFD suitable for desert cooler of any cap & testing etc complete all as specified and directed.
S & F suitable pad / grass ribs including packing complete set of three for each cooler all as specified and directed.
S & F PVC flexible pipe 15 mm bore suitable to desert cooler any cap for circulation of water etc all as specified and directed.
S & F plugs top 5 Amp for electric connection of desert cooler etc all as specified and directed.
S & F plugs top 15 Amp for electric connection for AC all as specified and directed.
S & F for ply wood 6 mm thick including painting with two coats of synthetic enamel paint over one coat of primer on one side fixing to window face complete wherever required for desert cooler etc complete all as specified and directed.
M & L for preparation of old surface of desert cooler any make any size of any size internally & externally complete body both internal & external surface with two coats of synthetic enamel paint gray shade over one coat of red oxide primer all as specified and directed.
S & F in repair including cutting dismantling desert cooler bottom water storage tank with primer & painting of tank cap upto 80 litre all as directed.
S & F in repairs PVC copper cable 1.5 sqmm three core for connection of desert cooler all as specified & directed
S & F single pole with a two pin & earth plug & socket complete with one single pole MCB of cap 20 Amp all as specified and directed.
M&l for refrigerant gas charging with 410 C gas (green gas ) suitable for 1.5 / 2 TR Ton AC including cutting of copper tubes soldering & fixing in position all as specified and directed.
Taking down carefully unserviceable street light fitting, high pressure, sodium vapour lamp type, 70 to 250 watts from poles,DSS & MT R &S hanger after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on pole, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No. 2,3,4,5,6& 7 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 1 here in before complete all as specified and directed. (a) Open construction ballast 70 watts copper wound for HPSV/metal healide lamp.
(b) Ignitor for HPSV lamp suitable for 70 to 250 watt.
© Condenser 15/20 mfd.
(d) Condenser 33 mfd.
(e) Holder Screw type for tubular HPSV/HPMV lamp 70 to 250watts
(f) Open construction ballast 150 watts copper wound for HPSV/MH lamp.
(g) Open construction ballast 250 watts copper wound for HPSV/MH lamp.
S & F HPSV 70W lamp, tubular type/suitable for posttop latern complete all as specified and directed.
S & F HPSV 150W lamp, tubular type complete all as specified and directed.
S & F HPSV 250W lamp, tubular type complete all as specified and directed.
S & F Matal Hallide Lamp 150 W, tubular, clear complete all as specified and directed.
S & F Matal Hallide Lamp 250 W, tubular, clear complete all as specified and directed.
Taking down carefully unserviceable Flood light fitting, MH type, 400 watts from high mast 12 mts long pole, Watch Towers including repaire of watch tower pannel wiring & DSS hanger/MTR&S hanger/ Tubular Poles, after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on high mast 12 mts long pole, Watch Towers & Tubular Poles, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No 9 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 60 here in before complete all as specified and directed. (a) Ballast for metal hallide lamp 400 Watts
(b) Super imposed ignitor for MH Lamp suitable for 400 W MH lamp
© Metal Hallide lamp 400 W , tubular, clear
Taking down carefully unserviceable Security/post top latern light fitting, CFL Type, 2 x 18 watts inbuilt ballast, L type lamp from wall/pole after disconnecting supply and sealing the cable ends for carrying out repair/maintenance at site/work shop and refixing the same on watch tower/Pole, connecting up and testing complete all as specified and directed. Note : (i) Spares required for repair of the fitting shall be measured and paid seperately under the item No 11 here in after as "Supply only". However, the labour cost for taking down spares & fixing shall deemed to be included in the quoted rate. (ii) Unserviceable spare parts shall be contractors property as per Sch of Credit.
Supply only the spares required for replacement of spares during the process of repair of the light fitting vide SI item No 64 here in before complete all as specified and directed. (a) Open construction VPIT ballast, copper wound for CFl 18 Watt. Make-118CFL bajaj/CG.
(b) CFL 18 watts 4pin type S type make.
© Holder4pin type for CFL 18 watts fittings.
(d) Post top latern outer glass cover for existing fitting.
M & L for painting of Steel tubular poles of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 113 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M & L road cutting of size 30 cm width x 45 cm depth for laying of cables incl making good the road with necessary returning fillingand bituminious portion with concret and bituminious mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching the surfaces with existing all as directed.Near to logestic section
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed of following sizes. (a) 50 sqmm, 3.5 core
(b) 35 sqmm, 3.5 core
© 25 sqmm, 3.5 core
(d) 16 sqmm, 4 core
(e) 16 sqmm, 2 core
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.15mm thick,burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to & including GI earth strip 25 x 4mm as earthing lead by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate no. 3 of SSR Part I, connected to main switch board and testing on completion with and including necessary earth work in any strata, filling the pit with charcoal and common salt surrounding the earth plate , watering arrangements with 20 mm dia light grade GI pipe, GI funnel with wire mesh, PCC chamber with M-10 using 40mm graded stone aggregates with RCC cover, 550 x 550 x 50mm thick, with type B1, reinforced with 10mm CTD bars @ 150mm c/c, both ways with 2 nos drop handles of 10mm dia round bars 400m long, 40mm bore, medium grade GI pipe for earth lead protection pipe up to test point complete all as specified and directed.
M & L for writing Pole No on PCC/steel poles with white synthetic enamelled paint on black background, size of lettter shall be 50 mm or less complete all as specified and directed.
S&F repairs LED street light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 90 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LSTN-90CDL-A,PHILIPS,WIPRO
S&F repairs LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 150 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LFLN-150CDL-A,PHILIPS,WIPRO
S&F repairs LED street light fittings with surge protector & Die cast aluminium housing with IP66 protection with LED as symmetric for 72 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed. make-CG cat no LSTN-72 CDL,PHILIPS,WIPRO
Rectification of cable faults including provision of straight through cable joint LT Epoxy complete with resine and hardner for cable of size 35 Sqmm 3.5 core complete all as specified and directed Make:- M-Seal / Denson / Rachem
M & L for scrapping down rusted, fallen paint from the Electrical LT pannel situated at 44WING/TXR Area including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint to the complete outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red xide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for outdoor type panel including MCCB's specific cabinet complete all as specified and directed.
S&F Isolator TPN 415 volts 63 Amp AC with necessary connection in existing pannel/DB BOX.
S&F Isolator DP 240 volts 40 Amp AC with necessary connection in existing pannel/DB BOX.
S&F MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel boardas directed by E-in-Charge.
S& F Thermo plastic cable looping boxes ,factory made ,IP 65 sheet of size 200x160x98mm separate detechated gland plate and including MCB TPN 20 A& bakelite connector 4 way 20 Amp with din rail , weather vermin proof front door opening with hing and locking arrangement ,fixed to pole all as specified &directed by EIC.Make -Henselelectric/neptune.
M&L for split AC checking /rectification of minor problem including washing,cleaning of outer/inner unit with filter by brushes & servicing of inner & outer unit complete all as specified and directed.
karambir constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .