Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC BAZAR RAM SUKH DASS FEROZEPUR CITY 152002 | FIROZEPUR | PUNJAB | 152002 | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹17.7 L+₹68,624.40 (4.04%)Rejected-Finance H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹17.9 L+₹87,544.74 (5.15%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹18.3 L+₹1.3 L (7.80%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹19.5 L+₹2.5 L (14.5%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
11 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST FEROZEPUR CANTT
GE WEST FEROZEPUR CANTT
MISC REPAIR TO EXTERNAL ELECTRIC SUPPLY AT AD PATTI HUSSAINIWALA AND BURJ DEVA SINGH UNDER AGE EM OF GE WEST FEROZEPUR CANTT
2021_MES_442736_1
802021/GE-31/E8
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST FEROZEPUR CANTT
₹37,000
Yes
25 Aug 2021
13 Jul 2021
13 Aug 2021
13 Jul 2021
11 Aug 2021
28 Jul 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layrs not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and dpositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable aftger laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L sub class B bricks locally available of size 22 x 11.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable
M&L 80 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint complete all as specified and as directed.
S&F Aluminium conductor steel reinforced (ACSR) for over head line of any size stringing and jointing on poles fix to insulator including, binding wires pointing sleves, aluminium tap and PG clamp etc complete all as specified after dismantling & taking out old U/s and as directed.
M & L in replacement of pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers & one galvanized iron nuts, 100 mm height, 65 mm dia for 1100 volts grade complete after dismantling & taking out old U/s and directed.
M & L in replacement of shackle type porcelain, vitreous white brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers & nuts complete for working pressure 1100 volts of size 90 mm dia, 75 mm height, size of steel straps 31 mm x 5 mm and 14 mm dia bolt complete after dismantling & taking down old U/s.
S&F loop type insulator vitreous porcelain white or brown with over all dimension 65x90mm with 16mm clearance hole complete all as specified and as directed.
M&L stay assembly complete with accessories as shown in elect plate No-1, dia to stay 16mm dia 180mm long including MS galvanised stay plate of size 300mmx300mmx6mm thick and galvized thible after dismantling of unserviceable stay set (above GL) complete all as specified and as directed (Note : Loop type insulator, stay wire, clamps, excavation in earth work, PCC founation shall be measured and paid separately under appropriate item).
M&L galvanized steel earth wire / cradle guard rectangular fabricated type with 4 mm dia all as specified & directed.
M&L cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape of size as dircted inclusive of 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Restringing and stretching ACSR conductor of any size as electric line on existing poles after disconnection of binding wires (dismantling & taking down), service connection etc and making binding and service connection complete all as directed.
Trimming of tree branches touching or within one mtr distance from HT/LT over head line upto 30 cm girth complete all as directed.(Pole to pole distance will be measured as each span)
M & L MCCB adjustable thermal & fixed magnetic setting type 200 Amps 4 pole of breaking capacity 25to36 KA 415 volt after and including taking down of unserviceable one complete all as directed.
M & L MCCB adjustable thermal & fixed magnetic setting type 250 Amps 4 pole of breaking capacity 25to36 KA 415 volt after and including taking down of unserviceable one complete all as directed.
M & L MCCB adjustable thermal & fixed magnetic setting type 100 Amps 4 pole of breaking capacity 25 KA 415 volt after and including taking down of unserviceable one complete all as directed.
S&F Changeover Four pole 100 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified.
Supply,Laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 10 Sqmm 4 core including taking out old cable complete all as specified. (Note for Srl item No 01,02,03,04 & 05 : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
Supplying and fixing 1100 volts 16 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supplying and fixing 1100 volts 10 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supplying and fixing 1100 volts 6 Sqmm grade heavy duty cable PVC insulated aluminium strandad conductor, served with inner sheathing of PVC tape and overall PVC sheathed in twin core cable circular/flat cpmlete all as specified and directed by Engr-in-charge
Supply,Laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 16 Sqmm 4 core including taking out old cable complete all as specified. (Note for Srl item No 01,02,03,04 & 05 : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
Supply,Laying and testing for UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 50 sqmm 3.5 core complete all as specified..
Supply,Laying and testing for UG cable XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 95 sqmm 3.5 core complete all as specified..
M&L XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross sectional area 70 Sqmm 3 Core
Cable jointing kit for 11000 V (Earthed) gradecable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm
Cable jointing kit for 11000 V (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 Sqmm
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4mm diameter earth lead by means of nuts bolts check nuts & washers of GI with earth strip protected by galvanised iron pipe 15mm bore (Medium grade) for poles/lightening arrestors/GO Switch including connecting to LT overhead lines all as directed including concrete pit with PCC (1:3:6) type CI, precast RCC(1:2:4) type B-1 cover slab of size 54x54x50cm thick reinforced with 8mm hard drawn steel wire fabricated weighting exc 4 Kg/sqm with one handl e for lifting made out of 8 mm diameter MS bar finnel wiere mesh 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke andsalt in alternate layers including necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completeion all complete as specified and as directed.
Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 mtr/11 mtr pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed. Note : Spare parts will be measured and paid separtely.
(a) Supply only LED driver 240Volt 50Hz for upto 25watt LED fittings.
(b) Supply only LED driver 240Volt 50Hz for 40 to 48 watt LED fittings.
(c) Supply only LED driver 240Volt 50Hz for 60 to 90 watt LED fittings.
Painting to steel tubular pole with existing paint and including cross arms 11 mtr long (except planting depth /PCC coping) with including one coats aluminum paint including preparation of old painted surface & Numbering of poles complete all as specified and directed .
Painting of LT PCC pole upto 1.5 mtr height from PCC, of synthetic enamel paint over a coat of cement primer with black and white strips with aluminum paint on pole & Numbering of poles all as specified and directed .
M & L GI bracket made out of 40 mm GI pipe light grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps nuts & bolts etc complete all as directed
M & L GI bracket made out of 20 mm GI pipe light grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps nuts & bolts etc complete all as directed
M & L for wiring for circuit/street light connection with FRLS PVC insulated Copper conductor sigle core cable in surface/recessed in PVC conduit of suitable size 2x2.5 sqmm+ 1x1.5 sqmm earth wire as continous earthing complete all as directed. Note : Two run 2.5 Sq mm of cable shall be measured as single run.
Collecting the unserviceable transformers of capacity 75 KVA/100 KVA (Indoor type) from the store yard of AGE E/M), draining out old transformer oil and depositing in AGE E/M store yard, carrying the transformers to workshop/factory for repairs and transporting the same back after repairs to store yard or installing, hoisting of transformers on two/four pole structure at height not less than 3 metre, making all electric connections with LT side jumpers and leads including earth connections etc and testing complete all as directed and as specified. Notes for above item : (a) Oil container for collecting old transformer oil will be arranged by the contractor (b) The T&P such as chain pulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor.
Opening the top of defective transformers of any make and capacity 75/100 KVA, removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking out defective/unservicable coil for check after disconnecting all connections and re-assembling of core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of items for repair including cleaning the removing sludge, dirt cleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromite paint inside , replacement of nuts bolts, thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workkshop to the entire satisfaction of Engineer-in-Charge complete all as directed and as specified.(including the following) (a) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified. Make :Hindustan/GRI (b) Replacement of LT brass spindles, nuts, bolts, washers for transformers of Suitable Capacity complete all as specified. (c) Silica gel breathers assembly filled with silica gel complete for transformers of capacity complete all as specified. Note: Transformer Oil Dehydration and Topping up will be measure and paid Seperately after repair of Transformers
Replacement of LT brass spindles, nuts, bolts, washers for transformers of capacvity 75 KVA complete all as specified.
Replacement of LT bushing porcelain capacity 75 KVA complete with gasket set all as specified
Supply only off load tap changing assembly with 7½ tapping at the rate ±2.5 percent stepping including making connections and testing complete for transformers of capacity 75 KVA complete all as specified.
Supply only CRGO silicon core as per existing thickness, size & design for transformer 75 KVA complete all as specified.
Top cover gasket set complete & specified.of 8 mm thicknes.
Opening ,draining of oil ,stoppage of leakage ,change of gasket set complete HV/LV rods at site refilling of transformer oil complete all as directed by Engr-in-charge capacity 75 KVA .
Supply & Fix silica gel breathers assembly filled with silica gel complete for transformers of capacity 75 KVA complete all as specified.
Supply & Fix in replacement of temperature gauge 0 to 300 degree centgrade for transformers of capacity 75 KVA complete all as specified.
M&L for Supply and pouring of New Transformer oil for Distribution Transformer Oil (as per IS 335) (EHV) in company sealed packed drum.Make: PowerOil, HP, Servo
Top up with fresh transformer oil in transformers in-situ after filtration/dehydration with minimum dielectric strength of 45 Kv at the gap of 4mm complete all as directed and as specified (Make : Savita/Ascorl)
Material and labour for Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 75 KVA to 100 KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM number with white paint over black base in letters not less than 10 cms in height complete all as specified and as directed.NOTE :- Painting shall be carried out at site.
Material and labour for removing old paint by paint removers and painting to existing outer & inner surcface of LT Control Panel of any size by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below of make Burger/Asian/Nerolac of first quality , all as specified and directed by Engr-in-Charge. (i) LT Control Panel (Outer & Inner Surface) - Dark Grey
Carrying out servicing/maint of 30 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
Supply only lubrication oil SAE-40 ( 15 W- 40 grade) of Make: Valvoline or HP Milcy Super 20W 40, all as specified and directed. Make: HP/Servo/Gulf.
Supply and filling of inhibitor corrosion (Coolant) suitable for radiators of 30 KVA capacity DG set complete all as specified and directed.
(a) Supply only Lub oil filter complete set. Make: Kirloskar/ Micco/Bosch
(b) Supply only Diesel filter complete set. Make: Kirloskar/ Micco/Bosch
(c) Supply only Air Filter as per sample
(d) Supply only Hose pipe & Flexible pipe complete set.
(e) Supply only Fan belt for water pump
(f) Supply only Fan belt for alternator dynamo
S&F in repair lead acid battery capacity of 80 AH, 12 volts for DG sets installed on pump house. Make:- Exide Express/Amron/Luminous
S&F automatic voltage regulator controller for 30 KVA as per specified and directed by Engr-in-charge
Supply & Fixing for replacement of Battery charger (iNVERTER) upto 250 AH, 24 Volts, single Phase AC supply 230V, 50 Hz including all type indicators, showing charging all as specified and directed by Engr-in-charge. Make :Luminous/ Microtek or equivalent.
Taking down copper/aluminium point wiring (light, fan,socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking of credit and making good disturbed surfaces of walls, floors etc.
Material & labour for concealed/Surface conduit point wiring complete with 1.5 Sqmm (nominal cross sectional area) FRLS PVC insulated multistranded copper conductor cable in and including heavy duty PVC conduit pipe with wall thickness 2 mm minimum (ISI marked) including fittings & accessories with MS concealed terminal boxes made of 2 mm thick MS sheet with 3mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 Sqmm FRLS PVC copper conductor cable multi-stranded in green colour code as earth wire connected to the common earth dolly as specified for the following (a) One light point/ fan point/ exhaust fan point controlled by one switch
(b) One three pin socket outlet 5 Amp on same board
(c) One three pin socket outlet 5 Amp on independent board.
All as per description of Srl Item No. 67 above but with 2.5 Sqmm cable and 2.5 Sqm copper conductor cable in green colour code as earth wire for 15 Amp socket outlet complete controlled by one switch.Note:- Socket /switch shall be measured and paid for separately
Supply & fixing socket outlet flush type 2-in-1, multipurpose, 3 pin 5 Amp and 2 pin 5 Amp and 2 pin 5 Amp complete all as specified.
Supply & fixing switch socket outlet flush type 2 in 1, multipurpose 3 pin 5 Amp and 3 pin 15 Amp 240 volts compete all as specified
S &F Switch piano, flush type single pole, one way, 230 Volts, 5 Amps complete all as specified and directed.
Supply and fixing in repair sheet metal enclosures single phase single door flush to wall fitted with bus bar and neutral link for MCB (without MCB's) 4 ways SPN complete all as specified and directed.
Supply & Fixing MCB, Single pole 240 V,6 - 32 Amps 10 KA 'B Series.
Supply & Fixing MCB, Single Pole and neutral 240 V, 32 Amps 10 KA 'B' series.
Supply & Fixing ceiling rose,PVC/Polycarbonate,isolated three terminals.
Supply & Fixing Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings.
Supply & Fixing step type regulator Piano switch type ( 5 step) for ceiling fan 1200/1400 mm size 230 volts, 6 Amps.
M & L in repair for sub main wiring with two single core PVC insulated FRLS cable with Copper conductor unsheathed cable of size 2 x 6 sqmm drawn through in and including PVC Concealed with 1 x 6 sqmm PVC insulated copper conductor single core for continuous earthing complete including PVC conduit 25 mm dia ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0 Sqmm and one run of 6.0 Sqmm PVC insulated copper conductor single core,one run of PVC conduit shall be measured as single run)
Supply & Fixing LED tube light fitting 18 Watts,4 feet long decorative ultra slim linear LED lighting fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cromton Cat No LCTL-9-CDL or equivalent
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm dia.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia.
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm dia.
Supply and fix Valves, Sluice, flanged type of class 1.6 PN,100 mm (4”)dia
Supply and fix gate valve conforming to IS 9338,50mm (2”) dia pipe
Supply and fix gate valve conforming to IS 9338,25 mm (1”) dia pipe
M&L for Gun metal gate valve ISI marked with Iron wheel head, screwed both ends for iron pipe or for socket or union for 20 mm bore pipe including taking down existing gate valve in existing transformers of any capacity complete all as specified ISI marked
All as per srl item No 88 here-in-before but for 25 mm bore pipe
S & F LED Security light fitting 1 X 45 watts with bracket (for housing security light fittings) made of suitable pipe light grade duly fixed to wall with suitable bolts,nuts,and washers complete all as specified and directed. Crompton Cat No LSTS 45CDL-1 or equivalent Havells/Bajaj/Philips
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.
M&L 40 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm
Karan Engineers
B.L. Chaudhri and Co.
V V AND COMPANY
M/s Bansi Lal
S S BUILDERS
ABHISHEK AND COMPANY
Bhupindra Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .