Loading…
Loading…
Tender ID
Tender Value
₹10.8 Cr
EMD Value
₹21.5 L
Closing Date
30 Mar 2026, 3:00 pmClosed
Dy. Chief Engineer
WAPCOS Limited (A Government of India Undertaking) Project Office, MEPZ Special Economic Zone, GST Road, Tambaram Chennai 600 045 Telephone 0444511 8383
CONSTRUCTION OF CENTRALIZED KITCHEN BUILDING AT MEPZ SEZ, TAMBARAM, CHENNAI - 600 045
2026_MSEZA_901614_1
WAP/ENVT/MEPZ/2025/ET/04
Open Tender
Civil Works
Item Rate
MEPZ-SEZ Tambaram
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
WAPCOS LIMITED
₹21.5 L
MEPZ admin building
2 Apr 2026
7 Mar 2026
31 Mar 2026
7 Mar 2026
30 Mar 2026
7 Mar 2026
16 Mar 2026
EXTERNAL DEVELOPMENT WORKS
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift (2 feet)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. (Depth - 230mm)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (Rubber Mould)60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out com New work (Two or more coats)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand). Stone ware spout
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 150 mm diameter
Supply of Soil Mix A (Quantity shall be checked at site after taking actual measurements by Client's and Contractor's representative) - Soil Mix A consists of Red soil-80%, Manure-20%. (200mm height approx.)
Supply and Laying of Mexican grass
Supply and Planting of Syzygium red - 1'6"-2'
Supply and Planting of Ficus panda - 1'6"-2'
Supply and Planting of Heliconia dwarf red - 1'6"-2'
Supply and Planting of Plumeria alba - 6"-8'
Irrigation & Dripping acessories for Landscaping (Note: Vendor to visit the site to understand actual site condition before submitting proposal for this work)
Providing, fabricating and erecting of MS Gate of Size 7.80 M X 1.50 M using structural steel members in position at all levels as specified in the drawings made out of standard MS sections conforming to IS 226/ 2062/ 800. Cost to include fabricating necessary gusset plates, stiffener plates, brackets, bolts, cleats, seating angles, etc., to the required size, shape, alignment, etc., as per the drawings. Cost to include welding of members using structural steel welding electrodes as per IS 814/ 816/ 817, testing as per IS: 7307 (Part-1), necessary equipments, tools and tackles, staging, required scaffolding, etc. complete, including a coat of zinc chromate primer and two coats of synthetic enamel painting.
SUB STRUCTURE WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 2.0 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
(Foundation filling, Basement filling) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy : For 75 mm compacted thickness in two layers using stone aggregate of size 63-41 mm graded @ 0.90 cum per 10 sqm key aggregate of size 20.0 mm graded @ 0.18 cum per 10 sqm. With paving asphalt grade VG - 10 @ 68 kg/10 sqm.
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M15 grade with minimum cement content of 240 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)
Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth :
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)
12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
20 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime the proportion of brick jelly to lime being 32 to 12 ½ by volume and laid over the RCC roof slab in a single layer and consolidated to the finished thickness by beating the concrete with wooden beaters of approved pattern keeping the surface constantly wet by sprinkling jaggery and lime water etc. Complete complying with standard specification.
Providing and fixing of 2 Hr Fire rated metal door double shutter (900mm+900mm) made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. Necessary MS frame support to be provided from truce ceiling as per manufactures specification before fixing FRD. Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm; Handle: Dorma - 450 mm High "D" type Handle; Hinges - Dorma 5" Flush suitable to Fire door. Note: all hadwares to be quoted for 2 shutters. M. (Note - Before ordering Cross Check the site for Dimension & get the approvel from the architect with shop drawing)
Providing and construction of HSD Yard with necessary civil works like retaining yard boundary wall with necessary alied civil works, 7ft height GI Metal chain linked fence (75x75mm chain link) with 75x75mm MS vertical column supports with 8' feet interval. Cost inclusive of necessary aluminium enamel painting. Yard floor to be filled with blue metal of size 40-60mm, with floor filling thickness of 150mm. Cost inclusive of necessary MS gate for entry. 5M - 4No.
Supply and fixing of MS Structure platform using ISMB section, MS angle for ODUs including safety handrails with supports. Scope shall include 2 coats of primer & 1 coat of anti corrosive painting.
PEB STRUCTURAL & PUF PANEL WORKS
Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. 50mm thick PUF external wall panel
Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.150mm thick PUF Internal Partition wall panel
Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.100mm thick PUF Internal Partition wall panel
Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.30mm thick PUF Internal Partition wall panel
Providing and Fixing of polyurethane foam for Sloped roof as thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.50mm (+38mm) thick PUF roof panel
Primary Members (Frames, Built-Up members) Material Specification: IS2062 –High Tensile Structural Steel of E350/ASTM A572 grade 345 Mpa yield strength HR Material. Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns) Hot Rolled Members (Beams, Channels, Tubes, Pipes) Material Specification: IS 2062: 2006 Grade A with minimum yield strength of 250 Kn/m2. Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns) Bracing Members (Rods, Angles) Material Specification: IS 2062: 2006 Grade A with minimum yield strength of 250 Kn/m2. Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns)
Secondary Members (Purlins / Girts) Material Specification: 345 Mpa yield strength Material Finish: All Z and C Purlins coated with Zinc (GI) of 275GSM Coating Mass
Flashings and Trims Material Specification: 0.50mm Color Coated Galvalume AZ150 Coating with Minimum Yield Strength of 550MPA. Material Finish: 0.50mmTCT Color Coated Galvalume SheetHardware and Fasteners Material Specification: MS, HS Bolts for Structure and Self Stitching and Self Drilling Screws for Sheet fixing Material Finish: Electro Plated Yellow Chromate, Hot dipped Galvanized
INTERIOR & RESTROOM RELATED WORKS
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge.
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M20 grade with minimum cement content of 270 kg /cum
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
Providing and fixing 75mm high Aluminium skirting of 1.5mm thick 75mm high extruded anodized aluminium skirting as per manufacture spec with necessart ply backing as per Architects approval.
Providing & fixing of 19mm thk., 200 mm wide Granite Threshold of approved Color.
Providing and fixing 12mm thk. commercial ply paneling finished in 1 mm thick. of approved shade laminate. 6X6 mm Aluminum "U" profile to be inserted to achieve uniform groove between gypsum and laminate paneling
Providing and fixing Commercial ply panelling, 12mm thk ply panelling finished with 6mm thk approved shade Lacquered Glass with suitable adhesive as per manufacturers specifications. 6X6 mm aluminium "U" profile profile section to be inserted b.w lacq glass and other finishes as per detail dwg.
Supply and Installation of Modular acosutic panel /Tile (Eco Panel board) of size 1200mm x 2400mm. 9 mm thk Eco board to be fixed over on gypsum parition / Wall. Cost inclusive of providing 6X6 mm Aluminum "U" channal section to achieve uniform groove between gypsum and Eco board paneling. Eco boards to be cut and installed to achive the pattern as per detail dwg provided by Architect.
Providing and fixing ply boxing of size 150X125 mm, made of 12mm thk. ply paneling finished with 1 mm thick. of Uni-color laminate. 6mmX6mm Aluminum "U" channal section to be inserted to achieve uniform groove between Laminate panel and other finishes.
Providing and fixing pelmets made of 18mm Pre laminated MDF Board of size 150mmx150mm wide along windows and glazed area and with necessary wood support, and also to mount the Blinds and Pull Down screens. The edges on the glazing side has to finished with enamel paint.
Providing and fixing 6mm thick commercial ply backing of 600mm x 600mm on mineral fibre modular false ceiling tiles to support light fitting, speakers, CCTV cameras, diffuser of grid work size with necessary cut outs for the same.
Providing and fixing 4 mm thk comm. Ply panel over on column / Gypsum partition / Wall
Providing and fixing 6 mm thk comm. Ply panel over on column / Gypsum partition / Wall
Providing and fixing 8 mm thk comm. Ply panel over on column / Gypsum partition / Wall
Providing and fixing 12 mm thk comm. Ply panel over on column / Gypsum partition / Wall
Providing and fixing 18 mm thk comm. Ply panel over on column / Gypsum partition / Wall
Supply and Installation of Half Height Toughened glass partition with 45mm x 25mm with minimum 1.5 -2mm thickness Polished Aluminium partition systems using snap on option for installing 10mm Toughened glass from 1200 to max 2400 mm. Only glass surface shall be measured and paid for this item. Aluminium profile frams to be used for all joints.
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick f ixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including f ixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush f inish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks)
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
Providing and fixing false ceiling at all heights including providing and f ixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and f inishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and fixing 18mm thick laminated shutter finished with approved laminate shade, inside face of shutter to be finished in 1mm thick laminate of approved shade inclusive of providing & fixing of Aluminum Grill finished in approved shade powder coating for ventilation, approved handle, 225mm tower bolts, Locks etc complete as directed.
Providing and fixing trap door of size 1200 x 1200mm in the false ceiling for A/c units with Access for HVAC services in PVCwith all hardwares, locks etc. complete.
Providing and fixing trap door of size 600 x 600mm / 450 x 450mm.
Providing and fixing junction box cover in Various size from 150x150mm to 600x600mm of 19mm thick. commercial ply with necessary seasoned wood framework to prepare leveled surface for carpet. Including of civil work neatly finished and leveled around the junction box.
Providing and fixing Low height Storage of 750mm high and 600mm deep in Laminate (Inner & External Surface to be finished in Laminate) finish Rate to include of necessary nos of Godrej make locks, Slow Close hinges for shutter, approved handles, magnetic ball-catch, Intermediate shelf,Tower Bolt etc complete as directed. Cost inclusive of Postformed top, Postformed Shutter or Louverd shutter.
Providing and fixing Over head Storage of 600mm high and 450mm deep in Laminate (Inner & External Surface to be finished in Laminate) finish Rate to include of necessary nos of locks, Slow Close hinges for shutter, approved handles, magnetic ball-catch, Tower Bolt etc complete as directed. Cost inclusive of Postformed Shutte / Glass shutter.
Providing and fixing storage unit with 600mm wide Granite counter top of approved shade laid on 25mm thick PVC integral board with Storage below - Storage inner surface to be finished with white laminate and shutters to be in laminate finish with concealed aluminium profile handle as per detailed drawing. Cost inclusive of 200mm high Granite band above storage.
Aluminium Door Frame with Single leaf style shutter door - Providing and fixing doors with aluminium door frame of size 100 X 50 mm size with 75 X 40 mm Aluminium anodized profile frame shutters with 10 mm thk toughendglass, 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame.
Aluminium Door Frame with Single leaf style shutter door - Providing and fixing doors with aluminium door frame of size 100 X 50 mm size with 75 X 40 mm Aluminium anodized profile frame shutters with 10 mm thk toughendglass, 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame.
Providing and fixing of 2 Hr Fire rated metal door Single shutter made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. (Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm; Handle: Dorma - 450 mm High "D" type Handle; Hinges - Dorma 5" FLush suitable to Fire door.
Providing and fixing of 2 Hr Fire rated metal door Single shutter made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications.
Providing and fixing of 2 Hr Fire rated metal door double shutter (900mm+900mm) made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. Necessary MS frame support to be provided from truce ceiling as per manufactures specification before fixing FRD.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 sqm and upto 16.80 sqm in the area
Providing and fixing pinup board made of 12 mm thk Jolly board with necessary ply backing support. Finished with approved Fabric. All edges to be covered with 12x12 mm Aluminium anodized profile Beading.
Providing and fixing of Pen Tray of Size 150X150 mm in acrylic finish.
Providing and fixing of Single seater sofa with back rest.
Providing and fixing Centre table of Size 600mm Dia with MS Powder coated leg and 25mm thk Membrane top.
Providing & applying Plastic Acrylic Emulsion Paint in minimum three coat, including preparation of surface, scrapping, sand papering, scaffolding etc complete.
Providing & applying Zinc Primer of approved shade and colour in single coat as per the standard. Cost inclusive of scaffolding etc complete.
Providing & applying Emulsion Paint in matt finish of approved shade and colour in minimum Two coat. Cost inclusive of surface preparing, scrapping, sand papering, scaffolding, etc complete.
Providing and fixing Printed Frosted film on Glass Partition with MCS warranty as per the manufacturer specification.
Providing and fixing Commercial grade Wall Paper of approved shade with recommended Adhesive of approved make which have 100% washable, Scratch resistance, Peel proof, & fire retardant properties. Cost to include preparation with Primer and 1 coat of emulsion on the punned surface / partition for receiving the wall paper as per the manufacturer specification.
Providing and fixing Vinyl graphics on wall with over laminate on wall with 3 yrs warranty as per the manufacturer specification. Cost to include preparation with Primer and 1 coat of emulsion on the punned surface/partition for receiving the vinyl poster as per the manufacturer specification.
Supplying & Installing CURTAIN BLINDS with Sunscreen perforated Roller blind optima series Basket 125 Tex with fabric specification of (Fabric compositition polyster 22% and PVC78%, Openenss Factor-5%, Thickness -0.68MM +/-5%, weight per m2 -480 GSM, yarns count in wrap/ weft/cm 19/18+/-5%, Fire Resistance-FR(USA) KFI(Korea), Tear Resistance-wrap11.9 daN+/ 5%,WEFT 150 daN+/-5%,colour fastness-6-7/8 (white colour base), artificial llight xenon lamp, UV resistance Min3 (White colour base), width 2.5M & 3 M. The Roller mechanism shall be a moulded unit made from engineering grade plastic polymer with PVC spring support. The Fabric shall be attached to the roller tube with high quality self adhesive tape with manual operation. The fabric shall be attached to the tube with adhesive strip. It should have minimum one ton fabric which must be placed on the roller before the working section of fabric start Operational action shall be smooth including necessary hardware for fixing at all places & as directed by Engineer-in-charge etc complete. The rate is inclusive of laying, conveyane, all other Tools and Plants involved in the work charges and all other incidental charges etc. complete and as directed by the engineer in charge.
Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved Room Name & Number, size 300mm x 100mm.
Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved Pull & Push, size 100mm x 50mm.
Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved No entry to unathorised persons, size 300mm x 100mm.
Providing and fixing of 25X25mm MS Box section frame welded together and finished with Black enamel paint. Top and bottom section of the frame to be finished with melamine polished 12mm thk Rubberwood. Inner surface to be covered with 12mm thk Rubberwood finish with melamine polish to be inserted into the MS frame work on all three sides to form a box profile to place planters or any artifacts. Outer suerface to be Covered with 12mm thk Ply and finished with melamine polished Rubberwood finish. Cost inclusive of providing planter box with Artifitial plants as per the attached Image / Dwg. Length as per the drawing, depth - 300mm, Height 1800mm.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Engineer in charge before use on work
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Keeping the site reasonably clean and removal of debris from the site every day. Should also provide for thorough cleaning of site before handover. Should also include final cleaning of site before handover to client. House keeping : Dedicated collection and storage area with individual bins to be provided for collection of different type of waste as per Construction and Demolition Waste Management Plan. Collected waste to be disposed out of the site on regular basis (daily or alternative days). Vendor should ensure that debris, dust, dirt created by each and every vendor to be cleared by House keeping workers. There should be at least one vacuum cleaner of industrial type to be given for Housekeeping workers. Shifting of debris from site to designated area outside of site by trucks or tempo is also in the scope of House keeping works. This does not include the house keeping that happens on daily basis. Providing housekeeping agency for general housekeeping works of Please note that this house keeping people would be responsible for only general housekeeping and monitored by Project Managers at site. Debris removal : Removal of debris in truck from the specific location in the site and disposing the same from building premises on daily basis as per the instruction given by the client / PM / Base builder.
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)
Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)From ground level upto plinth level
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing & fixing of 20mm thk. And 100 mm wide Granite Threshold with necessary related works of approved make & Color.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity
Providing and constructing single shutter door in 32mm thick blockboard finished with 1mm thk laminate provided with 200x300mm glass vision panel with 80 X 40mm Aluminium door frame up to required height (H) with 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing vision panel of size 200x300mm, 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame. Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm / GEZE TS 3000 V; High "D" type approved Handle; Hinges - Dorma / Geze 5" Flush suitable to flush shutter;
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Aerocon Light weight concrete filling up to 200-250 mm depth. cost inclusive of Providing top layer in 50 mm thk Grano Flooring.
Providing and fixing 600mm wide Wash basin counter made of polished 19mm thick granite slab top of approved shade laid on 25mm thick Marine Ply (IS:710) with suitable anto corrosion painted MS "L" angle grid frame supports, Includes 300mm high front facia & 100mm band above the counter top of same shade granite. All exposed surfaces of platform to be finished in same granite slab and all cut-out, exposed edges to be bull nosed with mirror polished. Cost to also include making necessary cut-outs for taking drainage pipes, Dust bins and Nahni traps in raised platform, all completed and finished to satisfactory conditions.
PHE WORKS - TOILET
Supply, fixing and testing of WHITE coloured vitreous china Wall mounted EUROPEAN WATER CLOSET with Exposed tank with ‘P’ trap, complete with solid plastic seat with cover, C.P. hinges and rubber buffers, 32mm dia C.P . cold water connection pipe including , C.P. bolts and nuts etc,. The work shall include cutting and making good the walls and floors etc. -
Supply, fixing and testing of 15 mm CP health faucet with bib tap of approved make with necessary CP flexible hose 1000 mm flexible tube, CP wall flange etc.
Supply, Installation, fixing, testing and commissioning of WHITE coloured vitreous china Rectangular WASH BASIN with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy) 32mm dia brass C.P. bottle trap, 15mm dia brass C.P. Angle stop cock with flange, 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors.
Supply, Installation, fixing, testing and commissioning of wash basin table mounted CP pillar tap, required cp flanges,angle cock,flexible hose,extension nipples, etc complete,
Supply, fixing and testing of Robe hook with PVC rawl plug & C.P. brass screw complete as required.
Supply and fixing of tissue holder with PVC rawl plug & C.P. brass screw complete as required.
Supply, fixing and testing of shower assembly units consisting of wall mixer for controlling the rain shower, jet shower and spout, CP brass wall shower arrangement. including cutting, chasing & making good the walls.
Supply, fixing and testing of Stainless steel Soap dish with PVC rawl plug & C.P. brass screw complete as required.
Supply, fixing and testing of Towel rack with PVC rawl plug & C.P. brass screw complete as required.
Supply, fixing and testing of Towel ring with PVC rawl plug & C.P. brass screw complete as required.
Supply and fixing of white colour viterous china Urinal with pressmatic cock for flushing with in built waste grating, C.P.cast brass bottle trap with extension piece including CI/MS bracket wall flanges, flush piping, flexible hose,extension nipples, Sensing range of minimum 20cm, Control box operated by etc complete.
Supply and fixing of white colour viterous china Urinal divider with rawl plug, clamp etc complete
Supply and fixing of Tissue paper dispenser with PVC rawl plug & C.P. brass screw complete as required.
Supply and fixing of Liquid soap dispenser with PVC rawl plug & C.P. brass screw complete as required.
Supply and fixing of solid state, no touch operting, fully hygienic hand drier of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls.
Supply, fixing and testing of racold / AO Smith make electically operated storage 15 L water heater inner container made from copper or stainless steel including the instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete. 15mm dia Angle stop cock with wall flange, 15mm dia C.P . hot and cold water connection pipe including , C.P. bolts and nuts etc,. The work shall include cutting and making good the walls and floors etc.
Supply, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.
a) 75mm dia (6kg/sq.cm pressure rated - Type - B)
b)110mm dia (6kg/sq.cm pressure rated - Type - B)
Supply, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete.
a)40mm dia (10kg / sq.cm)
b)50mm dia (10kg / sq.cm)
Supply, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects)
Supply and fixing of CP grating cover (150mmx150 mm). for drain outlet etc., complete.(The frame and grating shall be approved by Architects)
Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
d) 40 mm dia
e) 50 mm dia
Supply, fixing and testing of Full Bore Forged Brass Ball Valve Screwed End.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
d) 40 mm dia
e) 50 mm dia
PHE WORKS - KITCHEN & EXTERNAL
Supply of Grease separator for non vehicular movement area made of polyethylene as per DIN EN 1825; for below ground installation; 2 x maintenance openings; with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2½" blank cap and satisfy reaction to fire Class A . 2x Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124 Inlet and outlet dia: DN 200 Nominal Size: NS 20 Grease Storage: 820L, Sludge Storage: 2000L, Overall Capacity: 3565L Grease level monitor to consider with panel required Important Note:- It should be cleaned periodically 10 - 15 working days by tanker.
Supply, Installation, fixing, testing and commissioning of CP angle cock with extension braided hose of 600mm length , required cp flanges, extension nipples,etc.,
Supply, Installation, fixing, testing and commissioning of Stainless steel 304 smooth round edge gratings (Size - 900x300mm) with deep drawn silt bucket and removable foul air tap, Complete, It should etc.,
Supply, fixing, testing and commissioning of polypropylene pipe confirming to dimensions as per standard EN 1451 Series S16, Water Temp. up to 95 deg C/ 203 deg F(intermittent) or 90 deg C/194 deg F(Continuous) of including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, Soil & waste pipe line laid underground level.
a) 40mm dia
b) 50mm dia
c) 75mm dia
d) 110mm dia
e) 160mm dia
Supply,fixing and testing of Polypropylene floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) 0with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 110 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) (Location : Washbasin)
Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
d) 40 mm dia
e) 50 mm dia
Supply, fixing and testing of Gunmetal Ball Valve/ Brass full way valve with C.I. wheel Screwed End.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
d) 40 mm dia
e) 50 mm dia
Supply, fixing and testing of Gunmetal non-return valve-horizontal (screwed end)
d) 50 mm dia
Supply, fixing and testing of Y-Strainer Including Permanent Magnet, Flanged End with Drain Connection, Body : IS 210 Gr FG 200, Screen : SS 304, Ends : Screwed To BSP, Hyd -Test Press.: BODY: 15 Kg/Cm²
c) 50 mm dia
Supply, fixing and testing of brass Automatic Air release valve approved quality for booster line & Vertical
a) 20 mm dia
Supplying, installing, fixing, jointing, testing and commissioning of brass Electromagnetic Water flow Meter with BMS integration screw type tested to 16 kg / sq.cm.
c) 50 mm dia
Automatic OHT Level Control System, Contains Float switch and separate control panel arrangement for auto on/off in Each tank.
Supply, fixing and testing of PVC soil, waste and vent pipe confirming to IS 4985 of 10 kg / sq.cm pressure rated, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.
a) 75mm dia (10kg/sq.cm pressure rated)
b)110mm dia (10kg/sq.cm pressure rated)
d)200mm dia (10kg/sq.cm pressure rated)
Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724.
a) 20 mm dia
b) 25 mm dia
c) 32 mm dia
d) 40 mm dia
e) 50 mm dia
Supply, fixing and testing of glazed stoneware Gully trap, 300x300M C.I. grating ( medium duty), 100 mm dia outlet set in PCC 1:4:8 bed, 115 mm thick masonary chamber in CM 1:4, internal and external plastering 12mm thick in CM1:6, necessary earthwork, C.I. cover (medium duty) etc. Complete.
Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC cover, benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 600mm
Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 900x800 mm size internal and depth will 600mm to 900mm
Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 1200x900 mm size internal and depth will 900mm to 2500mm
Supplying, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting, refilling, and making good the same complete as required.
b)110mm dia (4kg/sq.cm pressure rated - Type - A)
Supply, fixing and testing of PVC Storm water pipe confirming to IS 4985 of 10 kg / sq.cm pressure rated, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.
b)110mm dia (10kg/sq.cm pressure rated)
d)200mm dia (10kg/sq.cm pressure rated)
Constructing in site of percolation well / rain water harvest pit of 1.2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall conssit of: a,Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. b.Bore hole of 160 mm dia from the bottom of percolation pit for a depth of 6m from the bottom of percolation pit drilled by using auger manually. c.Bore hole to be filled with medium sized pebbles to provide meehamical strength to the holes and enhance infiltration. d.Rate quoted shall be inclusive of earthwosk excavation, back filling, removing of excess earth as per the instructions of engineer - in charge. e.Providing, fixing, testing and commissioning of PVC Storm water drain line of confirming to IS 4985 of Agricultural series - 6 kgs / sq.cm pressure rated, for underground storm water pipe laid between catch basin to catch basin at outside the building, to the required slopes, jointing with solvent cement followed by application leak proof adhesivesof FRP paste, including haunching / covering only the joints with cement concrete 1:3:6 at all the joints with and testing of joints with water column etc. complete.
Supplying, installing, testing and commissioning of Booster pumps (1 working + 1 standby) for pumping the water from RO SS tank to KITCHEN , through pressure vessel for domestic purposes. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts, nuts,saddle and mesh. The pump shall be provide with suitable enclosure with strainer arrangement for protection. The pump shall be suitable for the following requirements: Flow rate of pump - 9.0 Cu.m/hr Pump design head - 30 M The pumps shall be provided with: 1 No. Pressure switch with caliberation.(if required) 1 No. pressure gauge 4" dial with valve tee and fittings. 4 nos. of ball valves of brass body nickel plated with stainless steel ball, lever operated and tested to 20 kg / sq.cm.on Suction and delivery side. 2 nos. spring operated type gun metal non return valve tested to 10 kg/ sq.cm pressure including necessary fittings like union, Hex, nipples etc., on delivery side. Voltage Stabilizer of suitable capacity to ensure uniform power supply to pump panel Automatic Booster card for automatic start and stop of pumps and sequencing of the entire system Micro processor based Built - in electrical control panel with motor starter relays, single phase preventor, dry run protection, indicating lamps, ON - OFF push buttons, alarm indication with signal in the event of pump failure, etc., and shall be suitable for 415 +/- 10% volts & 50Hz electric supply. Supplying, installing, testing and commissioning of polypropelene (PP) pressure tank with pre-charged diaphram, self supported, with necessary manhole, flange for inlet / outlet provisions, duly fitted with safty valve / pressure relief valve, pressure gauge and Danfoss make pressure switch , magnetic level switches 2 nos, vent valve, with two sets of gaskets, junction box and wiring, complete with electrics etc., as required:
Supplying, installing, testing and commissioning of Submersible HNS pumps (1 working + 1 standby) for pumping the water from UG Sump to all domestic use, through pressure vessel for domestic purposes. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts, nuts,saddle and mesh. The pump shall be provide with suitable enclosure with strainer arrangement for protection. The pump shall be suitable for the following requirements: Flow rate of pump - 12.0 Cu.m/hr Pump design head - 35 M The pumps shall be provided with: 1 No. Pressure switch with caliberation.(if required) 1 No. pressure gauge 4" dial with valve tee and fittings. 2 nos. of ball valves of brass body nickel plated with stainless steel ball, lever operated and tested to 20 kg / sq.cm.on Suction and delivery side. 2 nos. spring operated type gun metal non return valve tested to 10 kg/ sq.cm pressure including necessary fittings like union, Hex, nipples etc., on delivery side. Voltage Stabilizer of suitable capacity to ensure uniform power supply to pump panel Automatic Booster card for automatic start and stop of pumps and sequencing of the entire system Micro processor based Built - in electrical control panel with motor starter relays, single phase preventor, dry run protection, indicating lamps, ON - OFF push buttons, alarm indication with signal in the event of pump failure, etc., and shall be suitable for 415 +/- 10% volts & 50Hz electric supply. Supplying, installing, testing and commissioning of polypropelene (PP) pressure tank with pre-charged diaphram, self supported, with necessary manhole, flange for inlet / outlet provisions, duly fitted with safty valve / pressure relief valve, pressure gauge and pressure switch , magnetic level switches 2 nos, vent valve, with two sets of gaskets, junction box and wiring, complete with electrics etc., as required:
Supply of all equipment / machinary at site, installation and commisioning of equipments/ electricals/ piping inclusive of all types of taxes and duties as described in specification. IMPORTANT NOTES: The consumables and chemicals requried for intial start up and till testing and commissioning and handing over of Plant shall be borne by the vendor. Necessary text / Nomenclature to be provided / pasted on each equipment & flow indicators ( direction of flow in pipings) Plant Logistics: Feed Rate : 4000 Lit./hr Product Rate : 2000 Lit./hr Product Recovery : 50 % SS Tank : 4000 Litres x 2 Nos. HDPE Tank : 10,000 Litres x 2 Nos. Quality of Outlet water from RO: Total Dissolved Solids : < 100 mg/l Total hardness : < 50 mg/l
Supply, installation & testing of precast RCC ug sump of capacity - 22500 Litres, With necessary puddle flange arrangement of Inlet , Outlet, Overflow, Drain & Vent as per the size given in drawing. Sump should be provided with following requirements. 1. Steel grade - FE500 2. Concrete grade - M45 3. Heavy duty tank of 2 ton / sq.m. 4. Water proofing - Inside & Outside the concrete wall. 5. Manhole cover should be heavy duty. All equipments like excavator, compactor & dewatering system during installation should be contractor.
Electrical
11 KV Ring Main Gear (RMG) -OutdoorType Design, Manufacture,Assembly,Inspection and Testing before supply,Packing and delivery at Site ,erection, Installation, Testing & commissioning of 11KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,11kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by engineer in charge at Site. Outdoor Type , 11kV HT Ring Main Gear , With Incomer 2nos. of 630A ,26.2kA,3sec rating Horizontal Draw out type VCB as incomers and 1no of 630A ,26.2kA,3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements (AS PER TANGEDCO NORMS). The panel suitable for outdoor mounting & terminating of 300 sq.mm. 3 core HT XLPE 33KV (E) as incoming and outgoing etc, complete as directed and approved by engineer in charge. Please refer Power SIngle line Diagram and Technical specifications for protections and relays. Inbuilt battery backup needs to be considered. Note: Metering and Protection should be supplied as per TANGEDCO Requirements and Vendor should procure the RMG as per latest amendement from TANGEDCO, no additional payment shall be provided from client.
11 kV HT Panel-1 - SINGLE VCB Panel - Outdoor Type Design, Manufacture,Assembly,Inspection and Testing before supply,Packing and delivery at Site ,erection, Installation, Testing & commissioning of 11KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,11kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by engineer in charge at Site. Outdoor Type HT Panel, Comprising of 1No. 11 KV, 630A ,26.2kA,3sec Horizontal Draw out type VCB. The panel suitable for outdoor mounting & terminating of 300 sq.mm. 3 core HT XLPE 11KV (E) as incoming and outgoing etc, complete as directed and approved by engineer in charge. Please refer Power SIngle line Diagram and Technical specifications for protections and relays. Inbuilt battery backup needs to be considered.
Supply, installation, testing & commissioning of 24V D.C. switch tripping equipment as per technical specification requirement. It shall be builtin 3 phase step down transformer with SMF batteries, 24V, 25AH, battery charger with float / Boost type charging facility. It shall also be built in with single phase 6 way DC MCB DB with adequate incoming and outgoing DC MCB. It shall be totally enclosed floor / wall mounting type complete with all components, indicating lamps, toggle switches, fuses, etc.
Supply & erection of M.S. gate of size 24000mm wide & 2000mm height with all accessories,earthing of gates with braided copper including necessary civil works as required as per site condition. The Gate shall be painted with 2 coats of anticorrosive primer & 2 coats of Aluminiun enamel paint.
Supply & spreading of 40mm blue metal jelly filling upto 150mm depth over a river sand layer Rate shall include cleaning & levelling of the yard as required at site. ( from existing ground level of 150mm height)
Supply & erection of 2.5mtr long (65X65X6mm ISA angle with aluminium paint) for fencing with necessary concreting & all accessories as required.
Supply & fixing of chain link fencing of height 2mtr. With necessary clamps,fasteners,binding wires,earthing of fencing at all sides with suitable GI wires including all accessories as required.
Charges towards digging, excavation of normal soil to a depth of 1000mm x 600mm width after refilling the same and refilling the same after completion of works.-
Charges of manhole chamber sizes of 1000mm x 1000mm as above sl.no: 1.4 e & including necessary four side brick required.
Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 1000 KVA and 40 dg.C for oil and 45 dg. C for above 1000 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as 30 per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.
Supply, Laying, Testing & commissioning of 300 sq.mm. 3 core HT XLPE 11KV (E), XLPE Aluminium armoured cable laid in underground upto 1200mm deep / existing concrete trenches / cable trays/ hume pipe , including excavation of trench & minor civil works,covering of exposed portion as per Engineer-in-Charge. recommendation etc. including transportation from stores to site. Unpacking, with all labour and material as per specifications.
Supply, Installation, Testing & commissioning of outdoor cable end termination with heat shrinkable joining kit with all accessories including lugs suitable for 300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) etc, complete as directed by ENgineer in charge.
Main LT Panel (TTA Panel) with AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of MPCC PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. (Refer enclosed SLD) Incomer - 1 : (EB ) 1 Nos - 1600A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock) 1 Nos - 1600A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock) Metering for Each Incomer: 1No - Load Manager with RS485 Interface with Maxmimum Demand Indication & controller Of CONZERV CAT # EM3460 or equivalent. 1Sets - Dual Core Cast Resin CTs of ratio 1600/5A, Class 0.5 for metering. The CT burden shall be 15VA. 1set - 1600/5A, Cl 5P10 Resin cast CT's for APFCR. Except DG incomer 1No - Undervoltage relay with time delay 2 Sets - 63A 4P MCB 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1set - Class B/Class I - 3 Numbers of lightning arrester for the connection between Phase and Neutral and one number of lightning arrester between Neutral and Earth 1Set - LVM Incomer - 2 : (DG) 1 Nos - 1000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock) PLC interlock (restricted earth fault relay & Diffrential relay protection) Metering for Each Incomer: 1No - Load Manager with RS485 Interface with Maxmimum Demand Indication & Controllers Of CONZERV CAT # EM3460 or equivalent. 1Sets - Dual Core Cast Resin CTs of ratio 1000/5A, Class 0.5 for metering. The CT burden shall be 15VA. 1No - Undervoltage relay with time delay Protection relay for 51,50, 51N, 50N, 95, 27,59, 86, 32, 87, 81 (All relays shall be numerical type with all built in standard features for protection, recording, event logging, etc.) 2 Sets - 63A 4P MCB 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1set - Class B/Class I - 3 Numbers of lightning arrester for the connection between Phase and Neutral and one number of lightning arrester between Neutral and Earth Bus coupler: 1No - 1600A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (without Protection) high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. Electrical & Mechanical Interlock provided between incomers & Buscouplers with control wiring. Bus bar: 1600A 4P, 65kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 1Nos - 1000A 50KA TP ACB wth front drive kit 2No - 630A 50KA TPN ACB wth front drive kit 4Nos - 400A 50KA TPN MCCB wth front drive kit 2Nos - 250A 50KA TPN MCCB wth front drive kit 2 No - 160A 50KA TPN MCCB wth front drive kit 1 No - 100A 50KA TPN MCCB wth front drive kit Each outgoing feeder shall be provided metering : 1No - 96sq.mm Digital Multifunction meter (KWHr, KW,A,V,THD) with RS 485 1sets - Current Transformer Resin cast CT's for Metering 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link Note: Refer Tech Specification & SLD for outgoing feeder arrangements
HVAC Panel Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of HVAC PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 400A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 400/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 400A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 5 Nos - 32A, 9KA TPN MCB with front drive kit 10 Nos - 63A, 9KA TPN MCB with front drive kit
Utility Panel Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of UTILITY PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 250A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 250/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 250A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 5 Nos - 63A, 9KA TPN MCB with front drive kit 2 Nos - 100A, 16KA TPN MCCB with front drive kit
Power Panel Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of POWER PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 160A 25KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 160/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 160A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 5 Nos - 63A, 9KA TPN MCB with front drive kit
Lighting Panel Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of LIGHTING PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 100A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 100/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 100A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 5 Nos - 40A, 9KA TPN MCB with front drive kit
Kitchen Panel-1 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of KITCHEN PANEL-1 suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 630A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 630/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 630A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 01 Nos - 25A, 9KA TPN MCB with front drive kit 07 Nos - 32A, 9KA TPN MCB with front drive kit 04 Nos - 63A, 9KA TPN MCB with front drive kit 03 Nos - 100A, 16KA TPN MCCB with front drive kit
Kitchen Panel-2 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of KITCHEN PANEL-2 suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 400A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 400/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 400A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 01 Nos - 25A, 9KA TPN MCB with front drive kit 07 Nos - 32A, 9KA TPN MCB with front drive kit 04 Nos - 63A, 9KA TPN MCB with front drive kit 03 Nos - 100A, 16KA TPN MCCB with front drive kit
Kitchen Panel-3 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of KITCHEN PANEL-3 suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 160A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 160/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 160A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 11 Nos - 25A, 9KA TPN MCB with front drive kit 4 Nos - 32A, 9KA TPN MCB with front drive kit
Kitchen Panel-4 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of KITCHEN PANEL-4 suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 630A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 630/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 630A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 8 Nos - 25A, 9KA TPN MCB with front drive kit 1 Nos - 32A, 9KA TPN MCB with front drive kit 2 Nos - 63A, 9KA TPN MCB with front drive kit 4 Nos - 125A, 25KA TPN MCCB with front drive kit
Kitchen Panel-5 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of KITCHEN PANEL-5 suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 400A 35KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 400/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 400A TPN 35kA Aluminium Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Outgoings: 2 Nos - 25A, 9KA TPN MCB with front drive kit 6 Nos - 32A, 9KA TPN MCB with front drive kit 2 Nos - 40A, 9KA TPN MCB with front drive kit 4 Nos - 63A, 9KA TPN MCB with front drive kit 1 Nos - 100A, 16KA TPN MCCB with front drive kit
LT Kiosk - 1 Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of 1600A LT KIOSK (OUTDOOR TYPE) suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels (Refer enclosed SLD) Incomer Cum Outgoing: 1No - 1600A, 4P, 65kA Drawout type, Manual operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. Metering for Incomer: 1No - Multifunction meter (V,A,KWHr, KW, P, F) With 1set - Current Transformers (Cast resin type)1600/5A, class 1, 15VA 1 Sets - 63A 4P MCB 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip
UPS panel Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of UPS PANEL suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels& comprising of the following. Incomer: 1No - 63A 16KA 4P MCCB wth front drive kit Common Metering : 1Nos - 96sqmm Digital type . Energy meter RS 485 Port 1set - Current Transformers (Cast resin type) 63/5A, class 1.0, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link 1Set - Class B+C SPD with control MCB Bus bar: 63A TPN 16kA Copper Busbar. If the busbar is painted with a non-mettallic matt finish paint with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 1.2A/sqmm. Outgoings: 4 Nos - 40A, 9KA TPN MCB
BUSDUCTS Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered. Supply of 415V Sandwich construction Busbar trunking system with Multilayer Class-F insulation Conductors : Copper Rating : 1600A Configuration : 3P4W (100% N) IP Rating : IP55/65 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating
Design, supply, erection, testing and commissioning of 1600Amps outdoor type air insulated COPPER TPN CU.busduct with suitable support from ceiling / wall. The busduct shall be ACU. busbars of suitable size. The busbar should be support by epoxy insulators at regular intervals. The busduct shall run from Transformer secondary to the MV PANEL. The bus duct shall be fabricated using 2mm thick CRCA sheet. Current Density of busbars shall not be less than 0.8 Amps/ Sq.mm.
Design, supply, erection, testing and commissioning of 1600Amps Horizontal/Vertical bend
Supply,Fabrication & Erection of Transformer Busduct Adaptor Box with busbar arrangements & SMC supports
Design, supply, erection, testing and commissioning of 1600 Amps flexible joints suitable for Aluminium bus duct
Al Earthing strip - 50x6 ( with Hardware - Nots and Bolts )
Threaded Rod (1.5m Length , Dia 16 mm ) with anchor Fastener
MS Structure supports for Indoor or outdoor application .
MCB DISTRIBUTION BOARDS Supply, Installation, Testing and Commissioning of MCB Distribution board as per approved installation dwgs. Wall mounted MCB DBs with MS wire way box on top / bottom & on sides. MCBs shall be rated for 10kA with current limiting feature. Dummy ways to be covered with blank plates. All out going ways shall be labelled & laminated. Enclosure:1.2mm CRCA Sheet Steel, Powder Coated Door : Double Door Protection : IP 42 Cable Entry : Top & Bottom For UPS distribution RCCB's shall be harmonic resistant (HI/SI type) Bus bar : Shall be tinned Copper and 200% rating for UPS DB Neutral Link MCB's : 10kA 'C' Curve for Lighting & Raw power, 10kA 'D' Curve for UPS Distribution Note: 1) Separate Earth bus/Neutral bus for each phase 2) Each Circuit shall have yellow ferrules with circuit number 3) Accessories required for installation of DB's on Wall/Column/Gyp Board shall be considered 4) DB's shall be covered with powder coated (paint should match with DB Color) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items 5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB door 6) Safe shroud for Neutral link shall be provided
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 12 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Incommer - 40A TPN MCB - 1 No Phase Incommer - 40A 30mA DP RCBO - 3Nos Outgoings - 6A SP MCB - 36 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incommer - 63A TPN MCB - 1 No Phase Incommer -63A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 24Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
Supply, Installation, Testing and Commissioning of single phase, 16 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for EMERGENCY LDB. Incommer -32A DP 30mA RCBO - 1 No Outgoings - 6A SP MCB - 14 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPS DB Incommer - 63A TPN MCB - 1 No Phase Incommer -63A 100mA Si Type DP RCBO - 3Nos Outgoings - 16A SP MCB - 24 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for AC POWER DB. Incommer - 63A TPN MCB - 1 No Phase Incommer -63A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 24Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
LT CABLES & TERMINATIONS NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work. Supply, laying, testing and commissioning of the following sizes of 1.1KV grade Aluminium / Copper Conductor armoured power cables Insulation of XLPE laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. The Cost of sand, bricks and excavation should not be included in the rate quoted and measured separately. All cables shall be FRLS.
3 1/2C X 300 sqmm A2XFY
3 1/2C X 240 sqmm A2XFY
3 1/2C X 185 sqmm A2XFY
3 1/2 C X 95 sqmm A2XFY
3 1/2 C X 70 sqmm A2XFY
3 1/2C X 50 sqmm A2XFY
3 1/2C X 35 sqmm A2XFY
4C X 25 sqmm A2XFY
4C X 16 sqmm A2XFY
4C X 10 sqmm A2XFY
3 1/2C X50sq.mm 2XWY
3 1/2C X35sq.mm 2XY
4CX16sq.mm 2XY
4CX10sq.mm 2XY
4CX6sq.mm 2XY
4CX4sq.mm 2XY
1C X 16 sqmm Copper flexible cable
1C X 25 sqmm Copper flexible cable
1C X 95 sqmm Copper flexible cable
Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression.
3 1/2C X 300 sqmm A2XFY
3 1/2C X 240 sqmm A2XFY
3 1/2C X 185 sqmm A2XFY
3 1/2 C X 95 sqmm A2XFY
3 1/2 C X 70 sqmm A2XFY
3 1/2C X 50 sqmm A2XFY
3 1/2C X 35 sqmm A2XFY
4C X 25 sqmm A2XFY
4C X 16 sqmm A2XFY
4C X 10 sqmm A2XFY
3 1/2C X50sq.mm 2XWY
3 1/2C X35sq.mm 2XY
4CX16sq.mm 2XY
4CX10sq.mm 2XY
4CX6sq.mm 2XY
4CX4sq.mm 2XY
1C X 16 sqmm Copper flexible cable
1C X 25 sqmm Copper flexible cable
1C X 95 sqmm Copper flexible cable
LUMINAIRES Supply & Installation, Testing and Commissioning of following Light fixtures and lamps with all accessories, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture) Light fixtures complete with accessories like control gear, Drivers, Energy efficient high lumen output LED's, etc., Light Fixtures quoted rate shall include mounting bracket and lamps . Gripple/steel ropes need to be considered for suspended light fixtures Note: Lamp Colour tempature (CCT) shall be as approved by Architect / client/ Consultant. Vendor shall consider necessary fixing hardware like supporting rods, angles etc and components to install light fixtures. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Vendor shall assume a minimum suspension length of 1.5 Mtrs
Supply & Installation of hot dip Galvanized GI Single Section Octagonal poles of 8 mtr. long, Earthing studs, TPN loop-in and loop-out smart pack junction box with MCB & necessary 50mm dia GI pipes bent to shape for cable entry/ exit and including 3C x 2.5 sq.mm PVC multistranded copper wire between terminal block and luminaire and with coil earthing using 80 turns of 8 SWG GI. wire as per standards. (complete including all civil work for foundation etc) & Stand terminals as per specifications with one 10A (10kA) SP MCB and 20A TPN terminals. Supply and erection of RCC Civil foundation & "U" Bolts & Nuts.
Supply, fixing, testing & commissioning of 90W (8400Lm) LED street light luminaire with pressure die-cast aluminium housing with heat resistant toughened clear glass fixed with SS screws. with operating voltage range (140 - 310V AC). The luminaire shall be minimum IP66 protected. CRI greater than 75 and with colour temperature 5700K range. In addition to built-in 5kV surge protection in driver, it is equipped with 10kV external surge protection. LED having 50,000 burning hours with minimum 70% lumen maintenance and power factor 0.95 with THD less tha 15%. System consumption should be 90W with lumen package of 8400Lm.
Integral, SMD LED, IP40, 20W Surface Mounted LED Batten with System efficacy of more than 110 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
18W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life.Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1800 lm. (100 lm/W) - Cutout Dia-ø145mm.
Supply, Installation, Testing & Commissioning of LED Surface/Suspended Cylindrical Downlighter with a nominal system luminous efficacy >90Lm/W and Luminaire wattage ≈ 15W. Also Safe operating voltage 140-270V AC. Power factor should be >0.95 & THD should be <10% & CRI>80. SPD Should be 2.5KV Surge Protection. Dia : 100MM , Height ; 165MM And its should be Extruded Al.Housing with low glare MPO diffuser.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similiar to
Supply, Installation, Testing and Commisioining of 450mm dia 60w decorative type fittings. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx.
Supply, Installation, Testing and Commissioning of 5W/meter Non-integral flexible LED strip light with high brightness for indoor applications. Strip can be cut at marked interval to suit desired length. 35,000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT - 6500K, THD<20%, Powerfactor>0.9, Surge protection in CM-3kV, Multistage Isolated Constant Current Operated driver with range 100-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 400 lumens/meter.
Supply, Installation, Testing and Commissioning ofIP65 40W LED industrial batten equipped with co-extrusion PC housing, PC diffuser, PP end caps and ABS mounting clamps for surface mounting application. The seamless front frame is with white high transmission acrylic cover and decorative end caps with High on Efficacy > 110lm/W, Wide Operating Voltage : 140-270V AC Safe & Reliable High Surge Protection: 4kV, class II product, IK05 and power factor > 0.95, THD<10% with High Performance constant current, integral, non-isolated energy efficient electronic driver and Higher Life : 50,000 BH Operating Temperature -10degC to +45degC Dimensions : 1200mmx44.6mmx44.6mm
Supply, Conveyance, installation, testing and commissioning of 1200mm sweep ceiling fan with suitable size HG, 300mm long GI / WI pipe including cutting threading drilling and painting the rod wiring the down rod with required length of 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core Cu. Conductor flex wire including supply of down rod up to 24''including sh ackle insulator and suspension arrangements, etc as required 5 star rated BLDC fan with suitable regulaters
Supply, Installation, Testing & Commissioning of LED Recessed /Surface Troffer Light (2X2) Luminaire with a nominal system luminous efficacy >100 Lm/W and a Luminaire Wattage ≈ 30W with Electronic driver. Also Operating voltage of 140-270V with cut off and auto restart feature @325V. Power factor should be >0.95 & THD should be <10% & CRI>80. LED CCT options: 5700/4000/3000 K. LED Life should be 50,000Hrs. The luminaire should have Special low glare MPO diffuser. "Dimension :Length = 595 mm , Width = 595mm.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions
supply & instalation of 40W Gate Light along with all accesaries like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.
4 FEET FLAME PROOF LINEAR LIGHT
LIGHT FITTING ( COLD STORAGE AREA)
6W LED MIRROR LIGHT
Supply, Installation, Testing & Commissioning of LED COB Type Surface/Suspended Down lighter with a nominal system lumen output of 1500 lumens (1100Lm/W) and Luminaries wattage should not exceed 24W Also Safe operating voltage 140-270V AC. Power factor should be >0.95 & THD should be <10% & CRI>80. Color temperature – 5700K. SPD Should be 2.5KV Surge Protection. Dia : 80MM Height ; 170MM And its should be Extruded Al.Housing.The supply of accessories like clamps, supporting brackets and hard wares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FR LSH copper wire with all accessories required as per site conditions
WIRING FOR LUMINAIRES CIRCUIT MAIN (FROM DB TO FIRST POINT) Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 1.5Sq.mm PVC insulated ZH-FR LSH multistrand copper wire with 25mm dia MS conduit with all accessories as required as per site conditions.(lighting circuit mains)
POINT WIRING - SWITCH CONTROL Supply, installation, Testing and Commissioning of point wiring using 2R x 2.5Sq.mm + 1Rx 1.5Sq.mm for Primary & 3R x 1.5 for Secondary wiring FRLS 1100V wire of approved make drawn in 20mm dia GI conduit including all conduit accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses, switches and all consumables. The wiring shall be complete with ceiling roses, switches and all consumables. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Conduit colour to be black in all closed ceiling and white in all open ceiling Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be in civll vendor scope) For concealed conduiting, wall chasing and finishing need to be considered in the quote.
PRIMARY LIGHT POINT Supply, Laying, Testing and Commisiosning of 3R 1.5Sq.mm MS insulated ZH-FR LSH copper wire with 20/25mm dia MS conduit along with Modular 6A one way switch with moulded front plate GI anodised enclosure and other associated accessories as required as per the site conditions.
SECONDARY LIGHT POINT Supply, Laying, Testing and Commisiosning of 3R 1.5Sqmm MS insulated ZH-FR LSH copper wire with 20mm dia MS conduit along with other associated accessories as required as per the site conditions.
Supply, Laying, Testing and Commisiosning of 2R 1.5Sqmm + 1R 1.5Sq.mm MS insulated ZH-FR LSH Grey colour multistrand copper wire with 25mm dia MS conduit with all accessories as required as per site conditions.(EL lighting circuit )
Ceiling fan point controlled by a switch and stepped type electronic regulator. Rate to include cost of 10 mm Hilti MS hook in ceiling slab. Rate to include cost of regulator and switch.
Exhaust fan point with 6A socket provided near fan and controlled by a 6A switch
Supply, Laying, Testing and Commisiosning of 2R 6Sqmm + 1R 6 Sq..mm MS insulated FRLS multistrand copper wire in GI conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.
Supply, Laying, Testing and Commisiosning of 3C 2.5sqmm MS insulated unarmoured sheathed ZH-FR LSH flexible multistrand copper cable(WHITE) in trays / raceways with all accessories as reqd.(6A Ups socket)
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 2.5Sq.mm MS insulated ZH-FR LSH multistrand copper wire with 25mm dia MS Conduit with all accessories as required as per site conditions-Rawpower
Supply, Laying, Testing and Commisiosning of 3C 2.5sqmm MS insulated unarmoured sheathed ZH-FR LSH flexible multistrand copper cable(WHITE) in trays / raceways with all accessories as reqd.(6A Ups socket)
Supply, Laying, Testing and Commisiosning of 2R 4 Sqmm + 1R 2.5Sq.mm MS insulated unarmoured sheathed ZH-FR LSH flexible multistrand copper cable(BLACK) with MS Conduit with all suitable accessories as reqd.( 16A Raw power socket)
POWER OUTLETS (SOCKETS) Supply, Installation, testing and commissioning of the following Modular / Industrial Switch, sockets with modular front plate and accessories as per the technical specification & drawing details. The quoted rate shall be inclusive of approved make modular switches, accessories, 14SWG back box & shall be covered with removable film coat to protect from scratches and paint.
Supply and installation of 1No. Of 6/16A socket controlled by 16A SP switch - Weather Proof (With Back box) - IP66
Supply and installation of 2Nos. Of 6A socket controlled by 16A SP switch (With Back box)
Supply and installation of 3Nos. Of 6A socket controlled by 16A SP switch (With Back box)
Supply and installation of 16A Single pole switch for Tenant area Lighting
Supply, Fixing, Testing and Commissioning of 125A TPN MCCB enclosed in weather proof Enclosure with and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commissioning of 100A TPN MCCB enclosed in weather proof Enclosure with and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commissioning of 80A TPN MCCB enclosed in weather proof Enclosure with and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commissioning of 63A TPN MCCB enclosed in weather proof Enclosure with and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commisiosning of 20A, 3pin industrial type metal socket outlet controlled by a 20A DP RCBO MS Enclosure with plug top and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commisiosning of 32A, 3pin industrial type metal socket outlet controlled by a 32A DP RCBO MS Enclosure with plug top and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commissioning of 40A, 4P+E, 5 pin industrial type WITH PLUG TOP switched socket outlet with 32A 4P+E, 5 pin 'RCBO with ENCLOSURE, termination and is supporting accessories and surface mounting box of IP 67 degree of protection and other associated accessories as required as per the site conditions.
Supply, Fixing, Testing and Commissioning of 63A, 4P+E, 5 pin industrial type WITH PLUG TOP switched socket outlet with 63A 4P+E, 5 pin 'RCBO with ENCLOSURE, termination and is supporting accessories and surface mounting box of IP 67 degree of protection and other associated accessories as required as per the site conditions.
CABLE TRAY Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications. The rate shall include GI supports, bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc. The Proper Floor supports need to be considered for the terrace floor cable tray as per the drawing. Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings.
100X75mm Cable Tray
150X75mm Cable Tray
200X75mm Cable Tray
300X75mm Cable Tray
450X75mm Cable Tray
600X75mm Cable Tray
1000X75mm Cable Tray
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications.
200mm width X 75 mm depth X 1.6 mm thickness
ASSOCIATED ACCESSORIES Supply and fixing of 2mm thick PVC& 1.6mm thick GI conduit of various dia., exposed or concealed, with all accessories, Wall chasing, finishing, fish wire, etc., as directed by the departmental officers and the brand should got approval. (Exposed Conduiting - GI & Concealed Conduiting - PVC)
Supply and Fixing of 32mm PVC Conduits
Supply and Fixing of 25mm PVC Conduits
Supply and Fixing of 19mm PVC PIPE
19mm GI Flexible
150mm PVC Pipe for Earth flat sleeve
Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
Supply, fabrication, installation of chequered plates of 8mm thick for closing & sealing of cable trench. Quoted rate shall include painting with 2coats of black enamel paint over a coat of primer
Excavation, of cable trenches of required size for 600mm wide x 300mm buried for street light cable
2 hour fire rated fire retardant material sealing (UL Listed) all electrical ducts and openings made in the slab / wall / partition to take conduits / cable trays / raceways etc as required complete / as directed by the site incharge
Supply and installation of Temporary lighting for construction purpose. Providing and Maintaining the temporary lights fixtures and its distribution systems, same shall be removed after completion of work. 55 Nos of 40w, 4 ft tube light per floor
Supply and laying of pipes in wall / floor / in ground including chipping / excavation laying and making good the surface as required with all accessories like collars , bends and nipples required. Pipe shall be laid at a depth of 600 mm below ground level or under paved areas / under floor with including all civil engineering works as required.
150mm Dia
300mm Dia
Preparation & submission of applications, Liasioning with EB for getting addtional Load sanction, all necessary co-ordination upto completion of the project.
Preparation of CEIG drawings, Liasioning with CEIG for getting drawing approval, arranging inspection, getting safety certificate & preparation& submission of AS BUILT drawings. Four Sets of paper print of as built drawings& a soft copy of these drawings to be submitted to the clients while completion. (All statutory fees to be paid in this regard will be reimbursed by the client on submission of receipt & should not be included in this item). Including DG sets approvals.
Supply & Laying of 50x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x10mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x3mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 100x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 8 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & fixing of Earth bus chamber comprising of 50 X 6mm tinned copper of minimum 500mm length with stand off insulators mounted inside a powder coated enclosure with cover.
Supply & erection of 100mm dia Cast Iron earth electrode of 10' length buried in ground as per IS with necessary connecting clamps, watering arrangement &fasteners etc. The pit shall be filled with alternate layers of salt &charcoal. The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification.
Supply,installation, testing and commissioning of Copper plate Electrode Earthing System:Plate Earth Electrode using 19 mm dia Class B copper plate of size 600 x 600 x 3 mm thick.with heavy duty RCC cover (suitable to take fire tender truck load) of 450mm x 450mm x 300mm chamber.(Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.
Chemical Earthing Copper Coated: T-39 Cu. (80mm dia) - 3 mtrs with Back Fill Compund (25 kgs per Bag) includes Providing of RCC Chamber and Civil finishing including painting.
Chemical Earthing Copper Coated: T-39 Cu. (40mm dia) - 3 mtrs with Back Fill Compund (25 kgs per Bag) includes Providing of RCC Chamber and Civil finishing including painting.
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 20 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For Emergency lighting )
BATTERY RACK Supply and installation of 90mins Back up Battery Rack of epoxy painted sheet steel suitable for above mentioned UPS battery banks rating with separate compartment for circuit breaker. Each rack shall be supplied with 150mm high MS base stand . Cost includes of fabricated MS frame approximately 300mm height suitable for UPS Battery. The design of stool shall ensure uniform distribution of weight of 400kg/Sqm(65AH-50 Nos)
Complete wiring required between the UPS systems and it's battery banks & Battery Stands. Input and output wiring for the UPS system shall be provided by other agency. The cost shall be inclusive of Structural steel supports as per approved design for equal Load baring of 400kg/sqm for UPS system, battery cubicles also match level of the false flooring in UPS room.
Material Handling, Installation & Commisioning
Supply & fixing of Shock Treatment chart in TAMIL & English languages duly laminated/ glass framed
Supply of Insulation of Rubber mats of size 2m x 1m x 1.6mm confirming to IS 5424/96 and laying in front of panels
Supply & fixing of First aid box of Thadani make containing full compliment of medicines, ointments & bandages etc.,
Supply & fixing of 5kg dry powder type fire extinguisher or equivalent approved make with ISI mark including necessary fixing brackets
Supply & Installation of cast iron HT/LT cable route markers with necessary angle iron supports & civil works
Supply & fixing of 230V, AC portable & re chargeable emergency light with 2x9/11W PL lamp of BPL/Panasonic Make
Supply of Hand gloves tested for 11KV with ISI mark
4sets of Fire bucket filled with sand mounted on stand
Supply & Fixing of A0 size colored As fitted Single line drawing duly laminated / framed in Utility electrical room
11KV Reflector Danger Board
433V Reflector Danger Board
433V Reflector Danger Label
Supply of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 625 KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc.
Supply & laying of 4C twisted pair screened/ shielded Signal cable and termination - between DG set and AMF control panels, BMS panel etc - as per suppliers / manufacturers requirements and as per technical specifications
Supply & Insulation of suitable size of Exhaust Pipe for the above
Supply & installation of 50 mm thk. Insulation with rockwool and 24 guage aluminium cladding for Exhaust pipe
Supply & installation of 50 mm thk. Insulation with rockwool and 24 guage aluminium cladding for Silencer & fixing of Silencer
Supply & Initial filling of fuel for testing & commissioning
Supply , laying of 1.1KV Grade FRLS Copper armoured Control Cabling inbetween Day oil tanks, DG Sync Panel/DG power Panel, Auxillary power panel, Sensing cables from utility power panels along with its end terminations inclusive of brass double compression glands and copper lugs for complete auto & manual control and logical operations. All necessay control cabling shall be considered under this line Item required for fully auto operation of entire DG & Fuel system. Supply & end termination of following CU FRLS armoured power/ control (shielded Signal) cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required
12C x 2.5 sq. mm. YWY cable (From PCC to DG Sync. Panel)
End termination for 12C x 2.5 sq. mm. YWY cable
6C x 2.5 sq. mm. YWY cable (From Alternator to DG Sync. Panel)
End termination for 6C x 2.5 sq. mm. YWY cable
3C x 4 sq. mm. Cu. Flexible cable (Shielded - From PCC to PCC)
End termination for 4C x 2.5 sq. mm. Cu. Flexible cable
Supply and Installation of MS flats / angle iron supports for various purpose like fuel tank base frame work, cable tray supports etc. with necessary accessories, stands, various sizes including cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, minor civil works etc. as required.(Note: The flat / angle iron weight will be arrived on the basis of theoretical calculation only).
Supply, handing over of Fuel unloading hand pump with 10 mtrs PVC hose
Supply and Installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system. Cross sectional area of conductor should be 50mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
Supply and Installation of UV resistance Nylon/PU Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.
Supply and Installation of UV resistance Nylon/PU roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr.
Supply and Installation of Stainless steel Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross junction. Test Parameter Salt Spray Test ( IEC 62561-1) - No sign of Corrosion.
Supply and Installation of Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor. Test Parameter: Electrical Resistivity Test-0.036 µΩm Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
Supply and Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Tested for Electrical , Mechanical and chemical as per IEC 62561.
Supply and Installation of air termination rod of 1mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2.
Supply and Installation of air termination rod of 3mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories . Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2.
Supply and Installation of Stainless Steel Metal roof holder or Folding Clamp as per sheet profile for 8-10 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305. Test Parameter: Salt Spray Test ( IEC 62561-1) - No sign of Corrosion .
Supply and Installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system. Cross sectional area of conductor should be 50mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
Supply and Installation of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side wall . Test Parameter: Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1.
Supply and Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Tested for Electrical , Mechanical and chemical as per IEC 62561.
Supply and Installation of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
Supply and Installation of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1
Supply and Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter: Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. Tensile Test 290 to 510 N/mm². Adhesion no peel or crack & Bend test no seperation of Cu, Cu Coating thickness min. 70µm. Tested as per IEC 62561-2.
Supply and Installation of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side wall . Test Parameter: Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1.
Supply and Installation of Stainless steel Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross junction. Test Parameter Salt Spray Test ( IEC 62561-1) - No sign of Corrosion.
Supply and Installation of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. Supply and Installation of CAPE make earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kg Supply and Installation of CAPE make Earth rod clamp made for terminating cable / flat conductor. Supply and Installation of CAPE make Earth Chamber Inspection Pit made up of poly propylene material.
FAS WORKS
Supply, Installation, Testing & Commissioning of Addressable Intelligent Networkable single loop Fire Alarm Panel with battery back up, power supply, facility to add minimum 2 more loop card and the necessary interface card to connect a repeater panel and all hardware & software as per specification. Single Loop Panel
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required (Above Detector)
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required (Below Detector)
Supply, Installation, Testing & Commissioning of Addressable Intelligent Heat Detector as per specification
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supply, Installation, Testing & Commissioning of Bell control module
Supply, Installation, Testing & Commissioning of Addressable Control Relay modules for AHU & Fire dampers as per specification.
Supply, Installation, Testing & Commissioning of Addressable Control Relay modules for Access control, PA & Base builder fire panel as per specification.
Supply, Installation, Testing & Commissioning of AC Contactors (or) Interposing relay as required at site for Comfort AHU & other units Tripping as per specification
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
Supply, Installation of Power supply unit.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supply, Installation, Testing & Commissioning of Rack Mounted 480 W Power Amplifier with USB paly back option as per specifications
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
Supply, Installation, Testing & Commissioning of 4 door controller capable of entry & exit control & battery backup to power the controller, EM Locks, Readers etc., as per specification. Power Supply Unit and battery backup. as per specification
Supply, Installation, Testing & Commissioning of Smart Card Reader, shall work on transmit frequency 13.5MHz,. Support weigand as well as OSDP . It should have Multi-Layered security to ensure data authenticity and privacy as per specification
Supplying, Installation, Testing and Commissioning of Electromagnetic locks (fail safe type) for following type of Doors suitable for operation on 12 V DC having holding force 600 lbs for Single Leaf Door and 1200lbs for Double leaf door with suitable feedback i/c connection complete etc. as required.
Single leaf door
Supply, Installation, Testing & Commissioning of Emergency Release switch
Supply, Installation, Testing & Commissioning of Access Management software Including Attendance Software as per the specification.
Supply of Smart Card
Supply and Laying of 8 Core x 0.75 sq mm multi strand, ATC, shielded Cable as per specification
Supply and Laying of 4 Core x 0.75 sq mm multi strand, ATC, shielded Cable as per specification
Supply and Laying of 1" FRLS PVC Conduits, on the wall, columns, cable trays false ceiling etc.,with GI spacers, saddles including associated civil works
Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :-
2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 10TB (Terabytes)
Supply & Installation of 42" LED TV
Supply & Installation of 16 Port Layer 2 manageable POE Network switch (16 PORT-10/100 BASE-T & 2 NOS. 1-G COMBO PORT FOR UPLINK)
Supply & Laying of CAT6 SL Series Patch cords Panel Side
Supply & Laying of CAT6 SL Series Patch cords Camera Side
Supply & Laying of Information outlet with 2 port 110 style faceplate for Panel side
Supply & Laying of Information outlet with 2 port 110 style faceplate for camera side
Supply & Laying of CAT6 UTP Cable with 1" PVC conduit
Supply of Hand held Fire Extinguisher - CO2 - 4.5 Kg with suitable Metal Floor stand MS fabricated painted in black colour
Supply of Hand held Fire Extinguisher - ABC Powder - 6 Kg with suitable Metal Floor stand MS fabricated painted in black colour
EMERGENCY EXIT (400mmx150mm double side)
FIRE EXTINGUISHER (100mmx150mm single side)
EXIT (400mmx150mm double side)
MANUAL CALL POINT (100mmx150mm single side)
EVACUATION PLAN with AUTO GLOW in A2 (Acrylic sheet )
KITCHEN HOOD SUPPRESSION SYSTEM
Supply, Installation, Testing & Commissioning of VEG KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 10059 x 2439 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supply, Installation, Testing & Commissioning of VEG KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 10059 x 2439 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supply, Installation, Testing & Commissioning of VEG KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 10059 x 2439 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supply, Installation, Testing & Commissioning of NON VEG KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 6096 x 2439 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supply, Installation, Testing & Commissioning of NON VEG KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 6096 x 2439 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supply, Installation, Testing & Commissioning of RICE COOKING KITCHEN EXHAUST HOOD AUTOMATIC FIRE DETECTION & SUPPESSION SYSTEM Approx size 4877 x 1200 X 600. SHOULD HAVE THE PROVISION OF GIVING ALERT SIGNAL TO THE FIRE DETECTION SYSTEM OF THE BUILING IN CASE OF FIRE with Appliance Nozzle, Plenum nozzle,duct Nozzle. Nozzle and appliance line-up has to have proper coverage. Automatic detection should be possible. Storage tank should be filled with sufficient K Class extinguishing chemical, which can operate automatically and put off fire. Water supply to be connected for preventing the recoil of fire, after the fire gets extinguished; pressure should be enough for discharge. Manual pull station to be fixed. Gas shut-off valve to be fixed so that Gas supply cuts off in case of fire. Cartridge operated, no pressurized tank for extinguisher. Extinguisher Tanks should be fitted in Stainless steel enclosure made by the Manufacturer
Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63mm Sheet
Thickness 0.8mm Sheet
Thickness 1.0mm Sheet
Thickness 1.25mm Sheet
Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63mm Sheet
Thickness 0.8mm Sheet
Thickness 1.0mm Sheet
Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Damper
Actuator
Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminiumSupply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per pecifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required.
200 mm dia
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
150 mm width × 50 mm depth × 1.6 mm thickness
225 mm width × 50 mm depth × 1.6 mm thickness
300 mm width × 50 mm depth × 1.6 mm thickness
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suitable adhesive , as per specifications and as required complete in all respect.
HI - WALL SPLIT SYSTEMS Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating
Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. Non Inverter 3.0 TR (BEE 4 Star Rated)
Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. Non Inverter 5.5 TR (3.2 EER)
Supply and fixing of water drain pipe line (1” PVC Pipe)
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Indoor Unit
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Oudoor Unit
Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines.
Supply and fixing of Duct Mouth Dampers
Supply and providing acoustic for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminum Perforated Sheet
Supply and providing thermal insulation of 9mm thick vidoflex with Aluminum Foil
Supply and fixing of Flexible Canvas Connection
Supply and fixing of 50mm thick Anti Vibrating Rubber Pads
Supply, installation, testing and commissioning of factory fabricated powder coated FRESH AIR & EXHAUST AIR DOUBLE SKIN PLENUM 50-mm thick with PUF of density 40kg/cum +/- 2 filled with extruded Al. profiles. The thickness of outer & inner skin GI sheet shall be 0.8 mm. The plenum shall be fabricated only after Shop drawing approval, as per site conditions and assembled at site. Plenum should have factory made cutout with flanged provision for supply duct connection as per approved shop drg.
EXHASUT AIR UNITS - Supply, installing, testing, commissioning & handing over of 0.63mm thk GI sheet metal cabinet type Ceiling mounted double skin skin horizontal unit. Each unit complete with squirrel cage induction motor, centrifugal fan belt drive and vibration isolators. Motor shall be suitable for 230 + 10% volt / 415 + 10% volts, 50 cycles AC supply with and fan complete with Fan section with forward curved fan. Heavy duct flexible double layer canvas connection shall be provided at the outlet of unit Fan. All Exhaust unit shall be suitable for outdoor installation provided with Canopy
1000 CFM 15mm static pressure for Rest room
5000 CFM 20mm static pressure for Bulk store & Food Sorting store
Fully Automatic DOL/ Star Delta starters with features like Local/Remote, Auto/Manual & programmable timer for auto operation. Star delta starters shall be provided 15kW and above rating. The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. The panel to be tripped in case of fire, hence necessary contactors for the same to be provided. Weather proof enclosure to locate both Starter and VFD to be considered Indication of lamps & BMS provisions should be considered for same. 1.5k W
13000 CFM capacity TSP 50mm - FC Fresh air
12000 CFM capacity TSP 50mm - FC Fresh air
15000 CFM capacity Floor mounted TSP 125 mm
11000 CFM capacity Floor mounted TSP 125 mm
7500 CFM capacity
5500 CFM capacity
Starter panel with two starters and two VFD's ( For 18.5 to 15 KW). with VFD. (Outdoor type)
Starter panel with two starters and two VFD's ( For 15 to 11 KW). with VFD. (Outdoor type)
Starter panel with two starters and two VFD's ( For 11 to 5.5 KW). with VFD. (Outdoor type)
Supply, Laying, connecting and commissioning the following 1.1KV Grade AYFY/YFY/YWY Under Ground cables Quality equivalent with necessary clamps screws etc. and the cables shall be clamped along wall/column/laid in cable tray etc(the rates inclusive of suitable clamps, screws, GLANDS, lugs, etc but exclusive of cable tray complete.
4C x 16.0Sqmm CU XLPE FLRS Cable
4C x 10.0Sqmm CU XLPE FLRS Cable
4C x 6.0Sqmm Cu XLPE FRLS Cable
4C x 4.0Sqmm Cu XLPE FRLS Cable
4C x 2.5Sqmm Cu XLPE FRLS Cable
Supplying, laying and connecting 8SWG Cu wire laid in open fashion with necessary clamps, screws, interlinks etc for earthing of AC Equipments
Supply and Fixing 63amps TPN MCB Isolator with IP55 Protection at Near Fresh air fans
Supply and Fixing 100amps TPN MCB Isolator with IP55 Protection at Near Exhasut fans
Third party Air balancing as per the approved shop drawing using valid calibrated instruments, including Air Flow HOOD which has capability to measure volumetric flow rate with digital manometer, multi point averaging air flow sensor, airflow measurement station
Pressure Testing of Supply Air Duct Using Rolastar machines, as per SMACNA standards for duct erected
Supply, Fabrication and Erection of 'MS' angle for supports
Supply and fixing of Bird screen mesh for cowl piece duct
Supply, laying & terminationg of 4C x 10 sq.mm Copper Armoured Power cabling between isolator to outdoor unit.
Supply, laying & terminationg of 4C x 4sq.mm Copper Armoured Power cabling between isolator to outdoor unit.
Supply, laying & termination of 7C x 2.5 sq.mm Copper cabling between indoor to Outdoor unit.
Supply & laying of 8SWG Copper wire with double run from panel board to indoor & indoor to outdoor unit for Earthing.
Supply & Fixing of Insulated (13mm Nitrile Rubber) 18G GI Drain drip Tray for ductable Indoor Units
NETWORKING
Supply of Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Green (100% Considered) - Work location, 7 ft, Data
Supply of Dual Port Faceplate
Supply of Single Port Faceplate
Supply of Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Green (100% Considered) - Equipment end, 7 ft, Data
Supply of 4-pair, Cat6 UTP Cable, roll of 305m
Supply of Cat6 24-port Unloaded Jack Panel, 1U
Supply of Cat6 UTP Information Outlet, Green - Work location & Equipment end
Supply of 12U Wall Mount Rack with Front Glass Door, Fan tray with 2 fans, Hardware Screws - 20nos.
Supply of 1U, Single-sided horizontal cable manager, finger-duct style
Supply of 1Ph, 230V, 16A, 2U standard rack mount power distribution unit with 6 X Indian Round Pin 5/15A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA
Supply of Labels for Faceplate and Jackpanels
Supply of Labels for Patchcords in Rack end
Installation of Laying of Cat6 / Cat6A UTP Cable
Installation of Numbering of Cables both the ends, Termination of Information Outlet, Jackpanel, Fixing of Faceplates, labelling on both the ends
Installation of Testing of end to end Copper connectivity, documenation & 25 Years Warranty Certificate from OEM
Installation of Fixing of Wi-Fi AP
Installation of Patching of Patchcord between Switch to Patchpanel
Installation of Open & Network Racks
FURNITURE
Linear Workstation - Providing and fixing modular desking system of size 1350 x 600 x 1050mm - Above table top - Main spine & Return Spine - 1200x300mm Magnetic fabric screen with 3 Nos brackets. On Passsage side and single open end work station - 750mm, 18mm thk. fabric hung panel with suitable supports for sturdiness, Table Top : 25mm thk. Pre laminated table top with reverse chamfered Edge band, Understucture : Aluminium anodized / MS Power coated metal leg, Wire Management : Below table top Vertical & Horizontal wire mangment, flip box with soft close hinges to be provided above table top., flip box to have suffecient depth to accomodate imac adopter/charger, (For table top Size, profile & Grommet provision-refer attached layout). Please attach the image of Table.
2 Drawer Pre-Lam Pedestal - Pedestal combinations of 1 File Drawer and 1 pencil Box Drawers. The drawer top, and side panels including the drawer facia is made out of 18mm pre-laminated board (PLB). The drawer boxes are mounted on rollers slides/Soft Closing Runners to enable smooth operation of the drawer. The drawers are mounted on slides with ball bearings. The pedestals shall have central locking mechanism. With 5nos PVC heavy duty Castors for more stability. shall be as per manufacturer specification. The Pre-Lam Particle Board shall be of Grade II and Type II as per IS 12823 : 1990 The slides are ball bearing to ensure smooth movement. Slides & Meta box are of EBCO make, Handles & Locks from Hettich. Handle : PVC Recessed Flush handle, Lock : Cylindrical Regular Lock.
Cabin Table - Providing and fixing modular table in Laminate Finish of size - Main Table: 1800 x 750 x 750mm, Side Table: 900 x 450 x 750mm, Rear Storage unit - 2550 x 450 x 750mm, including 25mm thk. Pre laminated table top, MS powder coated / Anodised Aluminium understructure and leg, front metal modesty panel, Grommet, 3 Drawer pedestal, Wire Management, etc as per detailed drawings. (For table top Size, profile & Grommet provision-refer attached layout tables)
Cafe Table 4 Seater - Providing & fixing café table of size 1200 X 900mm Laziz Rectangle Table two-sides postformed 25mm MDF with laminate on top size: 1200x900mm Size & edge-profile can be customised with Foldable base 202 Grade - Base 37 (Stainess steel leg)
Medium Back Chair - Supply of Medium back chair without head rest Backrest: Mid back Upholstery: Back rest: mesh (black), Seat: fabric (black, grey, blue & red) Armrest: 1D PU armrest Mechanism: Synchro 1 Point locking Gaslift: Class 4, 112mm stroke Base: 640mm diameter nylon Castor: 50mm diameter nylon.
Cafeteria Chair - Supply of Polypropelene chair.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
tenderforcentralkitchen.pdf
Tender Documents • 16.99 MB
BOQ_947686.xls
BOQ • 1.61 MB
Corrigendum1.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .