Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC H NO 30 SECTOR 17 PANCHKULA 2022R6473 | PANCHKULA | PANCHKULA | HARYANA | 2022 | ₹1.0 Cr | L1 | Accepted-AOC Due to L1 |
| 2 | L2₹1.1 Cr+₹7.9 L (7.84%)Rejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹1.1 Cr+₹7.9 L (7.84%) | L2 | Rejected-AOC Due to L2 |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
23 Jan 2025, 1:00 pmClosed
PRADEEP KUMAR KUMAR
Nuh (P) PHED No. 1
Balance work for upgradation of existing 3.60 MLD STP based on MBBR Technology with Anoxic tank Activated sludge tank i.e completion of Tertiary Treatment Plant at Jobgipur Road Nuh Town.
2025_HRY_423417_1
20259EAD9A38 6769 4B57 AF12 6DC8477AFA50560PUH
Open Tender
Civil Works
Works
180 days
Nuh
Balance work for upgradation of existing 3.60 MLD STP based on MBBR Technology with Anoxic tank Activated sludge tank i.e completion of Tertiary Treatment Plant at Jobgipur Road Nuh Town.
2 documents required · 2 mandatory
₹15,000
₹2.0 L
Yes
28 Feb 2025
13 Jan 2025
23 Jan 2025
13 Jan 2025
23 Jan 2025
13 Jan 2025
Amount
VFD for blowers
BLENDING PUMP
Cleaning of MPS by Super sucker machine
Lifting arregement for Pumps and Gantery for lifting of Pumps at MPS
Providing and Fixing guide pipe 3-4` to guide lowering and lifting of motors in STP MPS complete. CI construction for standard applications. Standard kit contains a base, a pump adapter for will all requied bolts and fittings, and the upper guide rail positining bracket (FOR 1 NO MOTOR)
Repair of Sensor of online monitoring device along with replacement of data logger Modem, RS 485 Cable and all required accessories for data transfer from OMD to HSPCB and CPCB Server Make : - XYLEM
Laboratory refrigerators Purpose:-To preserve samples. Storage Temperature0-20 degree Celsius ,Vertical Shelves atleast 6 for storage of samples, Storage Capacity 500 Litres along with the in built-digit al temperature controller(company fitted ).Door for restricted accessibility.Castor wheels for easy mobility .Toughened glass door.NABL calibration certificate.1 year warranty (Make- CELLFROST,HAIR, WHIRLPOOL, Voltas)
Manifold filtration Assembly (6 Branch) Purpose: Manifold combine a number of separate filtration components into a single. •?Branch - 6 Place assemblies •?Funnel capacity- Minimum 300ml. Filth pore size -Minimum 20µm •?Funnel material – All SS 316 within built SS Clamp and SS lid Glass or SS316 with external ss clamp and cork capacity 250 ml •?Vaccum flask 2 ltr capacity •?Valve - PTFE •?Base holder – stainless steel 316L , Autoclavable-121 °c(15min.) •?Membrane filter 1 pack(100 No.) as per requirement /0.45µm pack of 100 (Make:- PALL LIFESCIENCES, Merck Millipore, Borosil,Labotroni cs/Athena/Axiva/ Glassco
Weighing Balance/ Analytical Balance Purpose: It is a highly sensitive lab instrument designed to accurately measure mass. Analytical Balance Capacity 220 gm Accuracy 0.1 mg with internal calibration Pan Size Ø 90 mm. Along with NABL Calibration certificate. Acrylic sheet cabinet box, as required by laboratory. 1 year warranty. (Make- Radwag, Mettler Toledo, Sartorius, Shimazhu)
Providing and Fixing of Main Control Panel made up of 16/14 guage CRCA sheet, consisting of 400 A MCCB incomer with 400 A change over switch, phase indicators switch, fuses volt meter and ampere meter, Aluminum bus bar, 6 no. outgoing MCCBH 160 Amp MCB 63 Amp including all connections etc
BOD Incubator Purpose: It is used for determining levels of organic matter and nitrogen in waste water samples Capacity:- 171 Litres Volume:- 06 Cuft • Refrigerated Insulation and Freezing in one unit. • Puff Insulated to keep the surface Temp. of body comfortable and avoid Cooling loss. • Silent energy saving Kirloskar/ Tecumseh compressor, Designed to circulate uniform air throughout the chamber with better imported coil condenser copper coil, improved Temperature distribution. • Polish 304 grade S. Steel interior corrosion resistant long life operation having adjustable shelves to make more space for different Height. • Kanthal A-1 tubular heater is fitted for better accuracy. • Safety Controller are provide with the Digital Temperature Controller Cum Indicator. • Full features Touch Screen Controller • Inner glass door with Aluminium Frame Powder coated full view door to observe the Test. • Process inside the incubator as desired while keep temperature uninterrupted. • Angle Iron Frame at bottom with castor wheel for easy movement. • Fitted with 2 Nos. Fan (One for Cooling and One for Heating inside the chamber) Technical Specification:- Temperature Range : 5°C- 60°C Temperature Stability : ± 0.5°C Max Material : GI Sheet with powder Coated, Inner : Stainless Steel 304 Grade Power Consumption : 220/230V AC ± 10%, 50 HZ Safety Function : Safety Controller for safety of Digital Temp. Controller Cum Indicator and Cooling Compressor with MCB Temperature Controller: a. HMI Display with Feather Screen Touch Digital Temperature Controller b. Continuous display of Temperature, Time, Day and Date Door Open Alarm c. Password Protected. d. Data transfer port: USB port Compressor : Displacement: 11,3 cm3, Application Low Back Pressure, Expansion: Capillar/Valve, Comp. Cooling: Fan Cooled, Nominal Power:- 1/3 hp, Voltage Range:- 187-264 V, Type CSR, Refrigerant : R 134a Along with installed UPS Battery/UPS System-2KVA,NABL Calibration certificate Included castor wheels for easy mobility of the equipment Duty Cycle : Continuous Along with NABL Calibration certificate Make-,AMBASSADOR, OPTICS TECHNOLOGY/ Impact/Thermofis cher/Thermi/ NSW
Open Reflux COD Digester Reflux Type Open Positions 08 Position Capacity 250 ml X 08 tubes Heating Block Aluminium Temperature Range Ambient to 180°C Temperature Accuracy ±1°C Display Graphic LCD Graphical representation of time and temp Yes Two point factory calibration Yes PID auto tune Yes User presets Yes Process Timer 0-999 min Temperature Control Yes with Set value and Present value Time Control Yes with Set value and Present value Connectivity to Printer Yes (upgradeable) Connectivity to USB Yes (upgradeable) Power consumptions 1400W Current Consumption 6 A Unit External Dimensions (WxDxH) Along with .8.No COD digestion vessels (414 x 414 x 283) mm Make - Borosil/ Thermofischer/ Glassco/Velp
pH meter Purpose: It is an instrument that is used to measure acidity/ alkalinity of a solution. • pH Range - 0 to 14.00 pH: Batteries: 4 x 1.5 V alkali-manganese batteries, type AA: Operational life: Up to800 h without/100 h with illumination. • Resolution/Accuracy 0.001 pH/± 0.005 pH:Operational life: Up to 800 h without / 100 h with illumination: Operation Temp -0°C-100°C • ORP Range ± 2500 mV: USB interface- USB B (device), data output: Admissible relative humidity- Yearly mean:(75%,30days/year: 95%, Otherdays:85% •`Resolution 0.1 (± 1200.0mV) / 1 mV (beyond): EMC-ECdirective2004/108/EC • EN61326-1: Dimension:240x190x 80mm: Weight0.8kg` • 1.2±0.2(±199.9mV)/±2mV(beyond) • Temprange0.0to100.00C (32.0to212.00 F) • Resolution/Accuracy0.10C (0.10F)/±0.3ºC/±0.5ºF (0 to70ºC) • ATC Yes (0to1000ºC) • Buffer Options USA: pH1.68,4.01,7.00,10.01,12.45 • NISTpH1.68,4.01,6.86,9.18,12.45 • No. of pH Calibration Points 5pointsBuilt-inElectrodeArmYes • Memory100datasets • Electrode Included ECFC7252101B, single junction pH electrode. • Temp Probe Included • LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter With US/UK/EUR/Japanplug,9V,6W, CENTRE Make:- Lovibond, Eutech, WTW(Xylem) , Metrohm, Mettler Toledo
Providing and fixing of Automatic power factor connection capacitor panel automatic APFCR- 125KVAR completer with relay, capacitors, conductors, switch etc. to maintain power factor- 0.95
Providing and fixing of motor control panel made up of 16/14G, CRCA sheet
Providing and installing of screw pumpsets for sludge 5m3/ hr. with ss-304 material alongwith motor bas frame accessories etc. complete with NRV SV and piping etc.
Providing chlorine tonners having capacity 930kg etc for disinfection of effluent sewage along with chlorine gas filled in it
Repair, refurbishment of secondary clarifier mechanism provided with current collector rubber/ metal wheels, gear box, motor, bridge and sludge scrappers.
Bidder Name
Amount
HL HANDA AND CO (GSTN-06AADFH2096N1Z3) BID ID -1202032
RAJEEV KUMAR GOEL CONTRACTORS (GSTN-NA) BID ID -1205051
RAJEEV KUMAR GOEL CONTRACTORS (BID ID -1205051)
RAJEEV KUMAR GOEL CONTRACTORS (BID ID -1205051)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .