Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.1 CrAccepted-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹4.1 Cr | 1 | Accepted-AOC Being Lowest |
| 2 | 2₹4.1 Cr+₹4.3 L (1.05%)Rejected-AOC | ₹4.1 Cr+₹4.3 L (1.05%) | 2 | Rejected-AOC Not lowest |
| 3 | 3₹4.2 Cr+₹6.7 L (1.63%)Rejected-AOC | ₹4.2 Cr+₹6.7 L (1.63%) | 3 | Rejected-AOC Not lowest |
| 4 | 4₹4.2 Cr+₹7.9 L (1.94%)Rejected-AOC 41 CUSTODIAN ANNEXE BEHIND WOOD LAND SCHOOL SHIVPORA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹4.2 Cr+₹7.9 L (1.94%) | 4 | Rejected-AOC Not lowest |
| 5 | 5₹4.2 Cr+₹12.1 L (2.94%)Rejected-AOC 368 MAHESHPUR SECTOR 21 PANCHKULA HR 134112 | PANCHKULA | PANCHKULA | HARYANA | 134112 | ₹4.2 Cr+₹12.1 L (2.94%) | 5 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
EMD Value
₹5.4 L
Closing Date
1 Apr 2021, 6:00 pmClosed
CE 31 Zone
HQ CHIEF ENGINEER 31 ZONE PIN 914631C/o 56 APO
AUGMENTATION AND IMPROVEMENT OF EXISTING ELECTRIC SUPPLY INFRASTRUCTURE AT OLD AIR FIELD SRINAGAR.
2021_MES_421515_1
800113/2020/E8
Open Tender
Miscellaneous Works
Item Rate
924 days
Old Air Field
Please refer NIT
10 documents required · 10 mandatory
₹2,000
GE 970 EWS
₹5.4 L
Yes
23 Apr 2021
17 Feb 2021
2 Apr 2021
17 Feb 2021
1 Apr 2021
18 Mar 2021
17 Feb 2021 - 18 Mar 2021
Amount
Note for Item No 1 to 4 : Excavation/earthwork wherever required shall be measured and paid for under item number 1.00 to 4.00, unless otherwise indicated in the description of the item. Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in hard/dense soil all as specified and directed.
Excavating in trenches not exceeding 1.5 metre wide, exceeding 1.50 m but not exceeding 3.00 metre in depth and getting out in hard/dense soil all as specified and directed. Note for Item No 1 & 2 : Entire excavation shall be carried out manually only and not through excavator/JCB to avoid damage of existing electric supply/water supply/signal assets. This aspect may be noted while quoting the bid.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing of excavated materials soil n.exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches for cable protection complete all as specified. Note: Measurement shall be taken only after punning down sand cushioning.
Supply and laying un-reinforced precast PCC cable Cover, class EHV, ISI marked, type- I with peak, size 600mm x 230mm x 50mm for covering cables laid dry flat as cable protection on sand all as specified.
Supply and laying un-reinforced precast PCC cable Cover, class HV, ISI marked, type- I with peak, size 300mm x 180mm x 40mm for covering cables laid dry flat as cable protection on sand all as specified.
Material and labour for Sub class 'B' bricks (old size) laid with its longitudinal axis perpendicular to the cable axis as in cable protection covers complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nuts and bolts, ISI marked of 40 mm dia bore for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nuts and bolts, ISI marked of 50 mm dia bore for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nuts and bolts, ISI marked of 80 mm dia bore for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nuts and bolts, ISI marked of 100 mm dia bore for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nuts and bolts, ISI marked of 150 mm dia bore for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade (UE), of size 3 core 120 sqmm complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade (UE), of size 3 core 95 sqmm complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded, galvanized steel round wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade (UE), of size single core 300 sqmm complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade (UE), of size three core 300 sqmm complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 6.00 Sqmm, 2 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10.00 Sqmm, 2 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16.00 Sqmm, 4 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 25.00 Sqmm, 4 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 35.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 50.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 70.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 95.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 150.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 185.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, laying, jointing and testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 240.00 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs (Bottle neck/eye let /ring type as per ground requirement) and cable glands jointed laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supplying and fixing steel tubular swaged pole with cast iron base plate finial taper plug, bolts, nuts and screws and specified type 410-SP-55 ( 11 metres long) in truely vertical position, 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts including preparation of surface and marking of pole number with black paint in yellow circle, complete all as specified and directed. (Note:- Necessary earth work, PCC coping will be measured and paid for separately under respective items)
Supplying and fixing steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410-SP-31 (9.0 metres long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer including marking of pole number with black paint in yellow circle complete all as specified and directed. (Note:- Necessary earth work, PCC coping will be measured and paid for separately under respective items.)
Supplying and fixing HT/LT MS cable route indicator, engraved the descrption on the disc not less than 6" dia and 6mm thick welded with 40 x 6 mm MS Strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base buried under the ground including necessary earth work complete all as apecified and directed.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish (PCC / Bitumen) to match the original finish all as specified and as directed at site.
Material and labour for cement concrete type D-2 (1:4:8) (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete for stay and pole complete all as specified.
Material and labour for PCC (1:3:6) type C-1, (using 20mm graded crushed stone aggregate) as in benching, coping for poles and 2/4 pole structure including weathering, slightly rounded or chamferred on edges and exposed surface finished even and smooth including necessary form work all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 3 core 120 to 185 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 120 to 185 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE, armoured , aluminium conductor cable of size 300 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for single core XLPE, armoured , aluminium conductor cable of size 300 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for three core XLPE, armoured , aluminiuml conductor cable of size 300 sqmm complete all as specified and directed.
Supplying and fixing cable jointing kit for 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for single core XLPE, armoured , aluminium conductor cable of size 300 sqmm complete all as specified and directed.
Supply, Installation, testing and commissionig 36kV, 630Amps, 25kA/1sec Non-Extensible SF6 Gas Insulated Outdoor Compact Switchgear with 3 Nos Manual Vacuum Circuit Breaker and 1 number Air Insulated Metering Panel (VVV+M) - 01 set (Total number of modules 4 pieces ) including 1 Number 33kV Touch Proof Termination kits and 1 number 33kV Cable Termination Services in each panels, 1 number Operating handle, along with necessary PCC foundation for mounting the panels, DC supply with VRLA batteries as per OEM recommended capacity including the followings :- THE STANDARDS AND MECHANICAL DATA CONFIRMS TO THE FOLLOWING :- Metal Enclosed switchgear: IEC 62271-200 General Purpose switches: IEC 60265-1 Disconnectors and Earthing switches: IEC 62271-102 Switch Fuse Combination: IEC 62271-105 Common clauses: IEC 60694 Pressure of SF6 gas: 1.4 bar at 20 °C Cable bushings outside cone: CENELEC EN 50181 interface C, Temperature class: -25 °C - +40 °C Outdoor, Suitable fot Altitude for Erection above sea level 1500 mtrs
The breaker should require the following Degree of protection : SF6 tank: IP 67 Front cover: IP 2X Cable cover: IP 3X Enclosure IP 54 Busbars: Not less than 300 Sqmm Copper Earth bar (external): 120 Sqmm copper - Bolt dimension: M10 Thickness of Stainless Steel Tank: 2.0 mm Colours: - Front cover: RAL 7035 Side and cable cover: RAL 7035 Enclosure IS 632 ELECTRICAL DATA REQUIRED FOR ABOVE BREAKER IS :- 36 kV Nominal voltage: 33 kV Rated frequency: 50 Hz Rated current for busbars: 630 A Rated current for cable switch disconnector : 630 A Short time withstand current (1 sec) cable switch disconnector : 25 kArms Rated current for transformer T-off : 630 A Short time withstand current (1 sec) V-module vacuum circuit breaker: 25kArms Impulse withstand voltage: To earth and between phases: 170 kV Insulation level: - Power frequency 1 min: 70 kV
(a) Each VCB's module consists the following :- The vacuum circuit breaker module having vacuum circuit breaker, stored energy spring mechanism for O - 0,3 s - CO – 15 s - CO operating sequence, two-position operating mechanism for the isolator and earthing switch, busbars, interlocking and earthbar including the following:- 1 Vacuum circuit breaker 36kV, 630A, 25kA, 1 Manometer (Only in A01V), 1 Padlocking device push buttons for EL3 standard, 1 Cable compartment standard, 1 Cable bushings interface C (400 bolted), 630 A, standard, 1 Single cable connection, 1 Capacitive voltage indication fixed type VPIS 1 Stored energy mechanism for Manual operation, 1 Self-Powered Protection relay type with RS485 communication port of CG/ASHIDA/L&T Make, 1 Aux. switch for vacuum circuit breaker position 2NO + 2NC, 1 Aux. switch for disconnected position 2NO + 2NC, 1 Aux. switch for earth switch position 2NO + 2NC, 1 Integrated low voltage box with door with hinge, 3 Ring core current transformer type 100/1A, 2.5VA, Cl. 5P10 for protection, 3 Ring core current transformer type 100/1A, 2.5VA, Cl. 1.0 for Metering, 1 Digital Multifunction Meter (A, V, kW, kVA, kWh, pf, F, etc.), 1 ON/OFF/Trip Indications
(b) The Metering panel consists of the following :- Air insulated metering module 36kV, 630A (non-arc proof) 3 Single phase voltage transformers 1 Primary voltage: 33000V 1 Secondary voltage: 110V 1 Number of metering windings: 1 1 Burden winding 1: 50 VA 1 Metering Class : 1.0 Note : Factory inspection for above breaker will be carried out by the officer detailed by Accepting officer before despatch of above breakers. The cost of the same shall be deemed to be included in the rate quoted.
Supply and fixing anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified.
Material and labour for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying including cleaning and necessary form work all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connecting to galvanized iron strip of size 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass after welding of GI strip to earth electrode to the full length of earth plate, GI light grade pipe 40 mm dia protection pipe upto test point, 20 mm dia GI medium grade watering pipe with funnel plate and wire mesh, PCC pit using cement concrete1:2:4, type B-1 with pit cover of size 30 x 30 cm made of RCC 1:2:4, B-1 (using 20 mm graded crushed stone aggregate) with suitable handle, angle iron frame made of angle iron of size 40 x 40 x 4 mm, adequate quantity of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling all as required at site including test point made out of steel plate of size 75 x 75 x 6 mm fixed to wall all as specified in plate No 3 of SSR part-I and directed by GE including testing on completion.
Material and labour for Galvanised iron strip 32 x 6 mm buried directly in ground all as specified and directed.
Material and labour for PVC sleeves suitable for LT/HT ACSR conductor/jumper of any type in R Y B Colours superior quality inserted over the ACSR conductor of 11 / 33 kv capacity all as specified and directed.
Material and labour for providing new ACSR conductor including stringing through existing poles, 2/3/4 pole structures, fixing in insulators, jumpers, and as using aluminium binding wire etc complete of different sizes as per rating required at site all as specified and directed. Note : Rates for new Aluminium tape/aluminium binding wire shall be deemed to be included in the rate quoted.
Supplying and fixing new air break gang operated switch Triple pole with 'D' type DO fuse single insulator type, mounted on superior quality polymeric based 15 insulators complete, mechanically operated, vertical operation mounted on post insulator and GI steel frame with new operating mechanism worked from ground level with GI pipe, for current rating upto 200 Amps, 11000 volts grade including necessary fixing clamps, nuts, bolts and washers all as specified and as directed.
Supplying and fixing new air break gang operated switch Triple pole with 'D' type DO fuse single insulator type, mounted on superior quality polymeric based 15 insulators complete, mechanically operated, vertical operation mounted on post insulator and GI steel frame with new operating mechanism worked from ground level with GI pipe, for current rating upto 400 Amps, 11000 volts garde including necessary fixing clamps, nuts, bolts and washers all as specified and as directed.
Supplying and fixing new rotating type air break isolator gang operated switch, Triple pole , mounted on 9 superior quality polymeric based insulators complete, mechanically operated, horizontal operation by copper blade type contact mounted on post insulator and GI steel frame with new operating mechanism worked from ground level with GI pipe, for current rating upto 400 Amps, 33000 volts garde including necessary fixing clamps, nuts, bolts and washers all as specified and as directed.
Supplying and fixing new Drop out fuse double stack channel type Triple pole , mounted on 6 insulators complete, mounted on post insulator and GI steel frame for current rating upto 400 Amps, 33000 volts garde including necessary fixing clamps, nuts, bolts and washers all as specified and as directed. Makes for serial item No.52.00 to 55.00 of BOQ :- Atlas/Pactil/GEC.
Supplying and fixing Hot dip Galvanised Iron cross arms, channel, bracing, support, clamps etc fabricated out of structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape, drilling holes, fixed on poles or jointed by means of elect welding complete for any description all as specified and directed.
Supplying and fixing LT Control panel board, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 630 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs/ change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 630 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs/ change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 630 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs/change over swicth/inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 900 x 750 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 400 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs/change over swicth/ inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1250 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 800 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 900 x 750 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 400 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 900 x 750 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 400 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 630 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1500 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 1200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1500 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 1200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Street Light Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 600 x 450 x 250 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Incoming :- (a) MCCB 4 Pole, Micro processor release, breaking capacity 36 kA at 415V, 50Hz, 63 Amp 415V (Make : L & T Cat No CM92153OOOOX1 or equivalent in Legrand/Schneider) - 01 No. (b) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- (a) 3 pole street light power contactor with astronomical timer relay 24 hrs, fuses, complete suitable for 32A capacity - 01 No including necessary O/L, SPP & S/C protection relay complete for street light connection . (b) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50 x 50 x 6 mm thick angle iron duly painted - 01 No. ( Location : T/C S/S, 970 JCO Club, Near Post No - 02 Nos, SL pt-2, SL pt -4 & Post No 20)
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1200 x 900 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 630 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 900 x 750 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 400 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 750 x 600 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 1000 x 600 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 900 x 600 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of 200 Amp rating for 3 phase and neutral, 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and supply and fixing the following incoming and out going accessories all as approved and comprising as under :
Supplying and fixing MCCB 4 Pole, current rating 800 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 50 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM96111OOOOX1 or equivalent in Legrand/Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 400 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM93003OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 315 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM93003OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 250 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM92151OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 160 to 200 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM92151OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 40 to 63 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM92153OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCCB 4 Pole, current rating 100 to 125 Amp, adjustable over load and short circuit with Micro processor release setting, breaking capacity 36 kA at 415 Volts, 50Hz including necessary spreaders/cable lugs /nuts, bolts and washers if required all as specified and directed. Make : L & T Cat Part No CM92152OOOOX1 or equivalent in Legrand /Scheneider.
Supplying and fixing MCB TPN 32 amps, 415 volts, C series all as specified and directed. Make : L & T Cat Part No BB30320B or equivalent in Legrand /Scheneider.
Supplying and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and and fixed with M.S. clamps, bolts and nuts of approved size for HT 25 x 20 CM size all as specified.
Supplying and fixing lightening arresters expulsion type complete with all fittings transmission class, discharge capacity 65 kilo amps, suitable for 11 KV all as specified and direcetd.
Supplying and fixing lightening arrestor Zinc oxide gap less type, station class suitable for 33 KV/10 KA complete with all fittings all as specified and directed.
Material and labour for including fixing for aluminium bas bar made out of 40 mm dia aluminium pipe/bolted type LM 6 alloy aluminium rigid parallel/pad/Tee/Stud/Rigid stud connector with nuts, bolts and washers for making 33/11 kv bus bar arrangement in 3/4/6 pole structures all as specified and as directed.
Supplying and fixing street light junction box made up of 2 mm thick CRCA Sheet steel enclosure front openable including MS Fixing clamps made up of 32 x 6 mm MS flat duly painted, GI nuts, bolts and washers of suitable size and the size of junction box shall not be less than 30 cm x 27 cm x 15 cm having 200 Amps rated aluminium bus bar of length not less 15 cm long for 3 phase 4 wire system mounted on Porcelain/epoxy insulators and provn of one MCB SP 2.5 to 6.0 Amps with locking arrangement complete all as specified and directed.
Material and labour for sub main wiring with 3 core PVC insulated stranded copper conductor 2.5 sqmm served with an inner sheathing of PVC tape, 1100 volts grade heavy duty cable drawn through and including PVC rigid Conduit and fixed on wall /poles etc and connected to light fittings all as specified. Note : One runs of 3 Core PVC cable 2.5 sqmm & one run of PVC conduit will be considered as one unit.
Supplying and fixing post insulator suitable for 11 KV HT working pressure in GOD / DO arrangements of any description complete all as specified and directed.
Supplying and fixing single post insulator, 33 KV with mounting spindle etc. complete all as specified and directed.
Supplying and fixing Pin insulator, Epoxy type 33 KV with mounting spindle etc. complete all as specified and directed.
Supplying and fixing disc insulator, 33 KV with all hardware fittings etc. complete all as specified and directed.
Supplying and fixing HT junction box for Cable termination suitable for 33000 volts garde, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 1000 x 1000x 1000 mm, having aluminium bus bar of capacity 630 A, 3 phase, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet powder coated of Simens grey colour suitable for 3 Phase 50 Hz, AC 33000 volts supply, duly insulated with heat shrinkable type sleeves as per colour code, supported on polymer/pocelain based insulators - 01 Set, danager notice board of 33 kv rating, angle iron pedestal made up off 100 x 100 x 8 mm angle iron duly painted all around grouting using PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) including independent plates at bottom for each out going and in coming cables and including necessary earthwork required in any type of soil all as approved and as directed.
Supplying and fixing HT junction box for Cable termination suitable for 11000 volts garde, Outdoor type, double door, cubical type, padestal mounted, overall size not less than 900 x 900x 750 mm, having aluminium bus bar of capacity 630 A, 3 phase, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheet powder coated of Simens grey colour suitable for 3 Phase 50 Hz, AC 11000 volts supply, duly insulated with heat shrinkable type sleeves as per colour code, supported on polymer/pocelain based insulators - 01 Set, danager notice board of 11 kv rating, angle iron padestal made up off 75 x 75 x 6mm angle iron duly painted all around grouting using PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) including independent plates at bottom for each out going and in coming cables and including necessary earthwork required in any type of soil all as approved and as directed.
Dismantling and taking down the existing unserviceable LT underground Cable of size 6 Sqmm to 70 Sqmm 2/3.5/4 core by disconnecting DBs/Poles/any description etc all as directed.
Dismantling and taking down the existing LT/HT over head ACSR line from any description all as directed.
Dismantling and taking down the existing LT/HT insulators of any type from any description all as directed.
Dismantling and taking down the existing LT/HT 9/11 mtr pole of any type all as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as directed.
Dismantling stay assembly complete (including demolition of concrete etc) all as directed.
ALCO ENGINEERSPVT LTD
CHINAR CONSTRUCTION TRADERS
Razdan Builders and Suppliers
FIRE ENVO SAFETY ENGINEERS
M/S Rather and Sons
ELECTRA ENGINEERS
SHAH AND SONS
RAMESH AND CO
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .