| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹1,726 (0.05%)Rejected-Finance PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L2 | Rejected-Finance L2 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/ MAINTENANCE OF CEILING, CHAJJA, PARAPET, STAIRCASE AND CONNECTED ITEMS IN OTM ACCN IN ZONE-I AREA UNDER JAIPUR MIL STN
2023_MES_572561_2
GE/J-64/2022-23
Open Tender
Civil Works
Item Rate
270 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹60,000
Yes
20 Apr 2023
27 Feb 2023
22 Mar 2023
27 Feb 2023
20 Mar 2023
7 Mar 2023
27 Feb 2023 - 6 Mar 2023
Amount
Dismantling of loose reinforced cement concrete any description by chieseling, wedging etc. cutting the unserviceable reinforcement as in roofs, floors (including ground floors), beams, staircases, landing, chajjas, slab, similar suspended article and columns work complete all as specified and directed incl removal all rubbish material where directed.
Chipping the RCC surface and cleaning the rusted reinforcement and exposed surface by wire brush, mechanical device or any other established method and applying the rust removing solution of approved make and quality with cotton swab to reinforcement and allowing to dry the same for 24 hrs, brushing of loose particles and applying 1st coat of rust preventive coating of polymer and cement slurry in 1:1.5 proportion with soft brush without adding water including applying another coat of rust remover cum passivator (rust off- 100) and rust preventive 4 hrs allowing air curing for 48 hrs etc. complete all as specified and directed
S&F MS TMT bars 6 mm to 8 mm dia cut to length bent to shape reqd incl cranking, bending spirally for hooping for cols, hooking ends and binding with steel MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
All as per item No 3 above but 10 mm dia & over
Drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-Dia of Bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including fixing the steel bars in position using Lokfix E77 a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive Strength (EN196) >122 N/mm2, Flexural Strength (EN196) >66 N/mm2, E Modulus (EN ISO 527-2) 6300 N/mm2. or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-In- Charge. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518.
a) 8mm dia Shear Connectors
b) Anchoring bars for 10mm Dia
b) Anchoring bars for 12mm Dia
c) Anchoring bars for 16mm Dia
Providing and applying a non shrink, polymer modified cementitious micro-concrete Renderoc RG or equivalent from SIKA/BASF/ FOSROC having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Renderoc RG can be applied in sections upto 100mm deep. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. Rate is inclusive of preparatory works from Note i) to v) below, rates also includes cost of materials labour, tools and plants, safety arrangement quality control and testing etc. complete as per specification and as directed by Engineer-in-charge.
Note : i) Chipping of plaster and unsound/weak concrete material till reinforcement bars to exposed to enable their rust removal under Note ii) below average thickness from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads. ii) Rust removal by Providing and applying a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair,It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth.
iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale , rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge. (iv) (a) Applying epoxy bond coat on the sound concrete substrate using approved spray machine or suitable brushes & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(b) Immediately after application of above bond coat as above pour prepacked dual shrinkage compensated micro concreting M40 grade, using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be reparied in RCC beam & columns etc, upto 100 mm thickness of micro concrete. Bonding agent shall have Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days. (c) Erection of water tight formwork and placing micro conrete as per manufacturer specification v) Work will complete only after proper wet curing has been done and testing of Microconcrete cubes filled up and cured by contractor during column jacketing work (100 mm size cube crushing strength at the end of 28-day to be not less than 45 N/sq.mm) and NDT tests mandated under item "Testing of works"
SHOTCRETING /Gunniting (For through repairs of RCC elements like Slabs, Beams etc) with incorporatring follwong notes.
Note : a) 30 mm avg thickness using prepacked dry repair mortar up to top floor level Shotcreting (Guniting) of R.C.C. components with a non shrink, single component dry spray mortar on the prepared surface if required, propping, scaffolding and safety arrangment quality control & testing of works, the rate will also include Chipping (sub item i below) cleaning of concrete surface and reinforcement rust with sand blasting (sub Note ii) below, curing with curing compound, quality control and testing etc. complete as per specifications and as directed. The dry spray shall be used at water powder ratio of 0.1, having yield of approximately 0.5 liters per kg. The dry spray mortar shall achieve compressive strength of 10 Mpa in 1 day and 40 Mpa in 28 days when tested as per ASTM C109. Flexural Strength shall be 13 MPa at 28 days as per BS 196 pt1; Tensile strength shall be 5 Mpa at 28 days as per BS 6319 pt 7;The drying shrinkage shall be less than 0.25% as per ASTM C 157; Depth of water penetration shall be less than 25mm at 5 bar pressure after 72 hours when tested as per DIN 1048 pt 5. Chloride Penetration shall of mortar at 28 days shall be low (1000 to 2000 C) as per ASTM C 1202,etc, complete. Product used shall have CE (CE-29842) marking and compliance according to Construction Products Directive 89/106/EEC (CPD). Thickness 40mm. Surface shall be evaluated by sounding /tapping with a blunt metal instrument by engineer incharge or his representative apart from cube tests for compressive strength, under Item "Testing of Works". Item rate includes providing and fixing of 18G 50mm * 50mm G.I wire mesh to be fixed at regular height with the exposed slab reinforment either using welding or binding wirem before carrying out shotcreting works.
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads . ii) Cleaning of concrete surface and reinforcement rust of by rust remover, including application of zinc rich coatings over rebar after rust removal process, as per direction of Engineer in charge.
M & L for 15mm thick polymer mortar to load carrying RCC members in one layers in proportion of 1:5:15 by weight of polymer of approved make and quality, cement and quartz sand with required WC ratio for desired consistency and applying and finishing by floating, curing after initial setting time etc. as per manufacturer specification etc. complete all as directed and specified.
M & L for 30mm thick polymer mortar to load carrying RCC members in two layers in proportion of 1:5:15 by weight of polymer of approved make and quality, cement and quartz sand with required WC ratio for desired consistency and applying and finishing by floating, curing after initial setting time etc. as per manufacturer specification etc. complete all as directed and specified.
M & L for applying SBR bond chemical of approved make before applying polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface using nylon bruses scaffolding labour etc. complete all as directed
M & L for drilling and fixing teflon perforated nozzles in RCC members including drilling 14mm dia 50 to 100 mm deep holes in structural members at the intervals of 600 mm in staggered manner all as directed including cleaning the holes by air blowers prior to fixing nozzles and fixed nozzles in cleaned holes . External ends of nozzles to be machined to receive outlet of grouting gun. nozzle is fixed by mean of epoxy to ensure complete sealing and cure the system for min 12 hrs under supervision of qualified supervisor all as specified and directed.
M & L for injecting high performance non shrink, free from high strength antiwash polymer cement grout of approved make by addition of water as per manufacturers instructions and specification into honeycombing area/porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 Kg/cm2 and subsequently cutting/ removing of nipples and sealing of holes with epoxy putty EPW 1010 etc. complete all as directed
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick finish with rough finish flat surface. The shuttering shall be of min 12 mm plywood sheets placed in position to receive flowable microconcrete.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvves including supports, overhangs, etc. also splays between floors and beams, etc finish with rough finish flat surface.The shuttering shall be of min 12 mm plywood sheets placed in position to receive flowable microconcrete.
M&L Formwork to sides of pillars, posts, struts, piers,columns, and stanchions, etc finish with rough finish flat surface.
M&L form work to chullah hoods, chajjas, troughs and similar items including edges finish with finish flat surface.
M & L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n exc 20cm wide with rough finished surfaces and staging upto 21 m from GL complete all as specified and directed
M&L for RCC 1:1.5:3 nominal mix using 20mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
M & L brick work using Subclass B bricks in exc. 6 m mean radius on plan built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish outside MD land complete all as directed.
M&L rendering 15 mm thick in CM 1:4 on brick masonry surfaces on fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed..
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even etc complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 including as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed .
M&L rendering 5 mm thick in CM 1:3 n exc 3.00 sqm each patch in ceiling patches in ceilling finished even and smooth without using extra cement complete all as specified and directed
M&L for thourughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work ,preparation of existing old surface with applying 1mm avg thick putty in patching (priming seal -o- prime ) on platered surface and two coat of weather proof exterior emulsion paint (weather coat smooth) using hand roller on external Wall Surface, complete all as specified and as directed
M&L for thourughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work ,preparation of new plaster surface with 1mm thick (avg thickness) putty (priming seal -o- prime ) on platered surface and two coat of weather proof exterior emulsion paint (weather coat smooth) using hand roller on external Wall Surface, complete all as specified and as directed
M&L for providing and filling epoxy putty into RCC crack after opening up in V-groove manner approximate 5x5mm size using mechanical cutter, properly cleaning the same by compressed air to remove loose dust, dirt etc and filling the same using Nitcote VF. Three component solvent free, thixotropic, Epoxy resins based putty having 100% solid contents, mixed density of 1.6 g/cc, compressive strength 50 N/sqmm, pot life of 40 minutes at 24° C Drying time 8 hrs, recoatable time 24 hrs and finishing in line and level with existing concrete surface etc. complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections),including distance pieces, cleats etc conforming to Fe 410-W Gde E-250 quality A including fabrication, erraction and fixing complete all as specified.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M&L for complete removal of existing treatment on ceiling, including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over one coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls & applying two coats of white wash by mechanical means complete as spd & directed
M & L Complete removal of existing treatment of old plastered surfaces of ceilling and Washing, rubbing down and stopping of painted surfaces & applying two coats of white wash by mechanical means complete all as spd & directed
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L preparation of new steel surface of any description n. exc 10cm in width or girth when un connecting to other painting surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair 15mm bore GI tubing medium grade with all fittings to fixing on wall or concealed of fitted to ceiling or laid under floor complete all as specified and directed
S&F in repair 20mm bore GI tubing medium grade with all fittings to fixing on wall or concealed of fitted to ceiling or laid under floor complete all as specified and directed
S&F in repair 25mm bore GI tubing medium grade with all fittings to fixing on wall or concealed of fitted to ceiling or laid under floor complete all as specified and directed
Taking down PVC pipes including all fittings like shoes, bends, swan necks etc of any dia all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75 mm bore complete all as specified and directed
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm complete all as specified and directed
S&F PVC (SWR) junction single, (Single T) equal or unequal for 75mm dia bore complete all as specified and directed.
S&F in repair 150 x 150mm stainless steel grating fixed on floor /Nahani trap complete all as specified & directed.
S&F PVC (SWR) bends any radius 75 mm bore complete all as specified and directed
S&F PVC (SWR) bends any radius 110 mm bore complete all as specified and directed
S&F PVC (SWR) vent cowl equal or unequal for 110mm dia bore complete all as specified and directed.
S & F repair for Bathroom Duct Pipelines for Waste Water Pipe, Domestic Water Pipes and Riser supply downtake pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Waste Water Pipe 2 1/2" PVC, 2. Water Supply Down take lines 3/4" GI - 2 nos. and 3. Riser Supply Downtake pipelines 3/4" GI - 1 nos. running from Terrace to Ground Floor Vertical Fixed line with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 20" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade :- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.:- 1. Profile Bracket of A2 Type (Wall distance 3") - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 20" - 1 No.; 3. U Bolt R/M for 2 1/2" PVC Pipe Dia. - 1 No.; 3/4" GI pipe Dia. - 3 nos. 4. Mono Bracket for 3/4" Pipe Wall Distance 3" - 1 no. and 5. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. (Refer CE Jaipur Zone Technical Drawing no. TD/2022/01.) Make :- Shaivi or equivalent as approved by GE
S & F repair of Toilet Duct Pipelines for Soil Water Down take pipe fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt System - 1. Soil Water Pipe 4" PVC - 2 pipe and running from Terrace to Ground Floor Vertical Fixed line with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 22" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade :- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.:- 1. Profile Bracket of A2 Type (Wall distance 3") - 2 Nos. 2. Slotted C Channel of B3 Type Size 22" - 1 No.; 3. U Bolt R/M for 4" PVC Pipe Dia.- 2 Nos.; 4. Mono bracket for 4" CI pipe wall distance 4" - 1 no. and 4. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing.( Refer CE Jaipur Zone Technical Drawing no. TD/2022/01.) Make :- Shaivi or equivalent as approved by GE
S & F repair of Waste Water Supply pipelines fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt System - Waste Water Down take pipes 2 1/2" PVC - 1 no. running Vertical Fixed line from 1st floor to Ground floor with wall distance 4": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3") of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 10" (Continuous Slotted C Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade:- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.:- 1. Profile Bracket of A2 Type (Wall distance 3") - 2 Nos. 2. Slotted C Channel of B3 Type Size 10" - 1 No.; 3. U Bolt R/M for 2 1/2" PVC pipe Dia. - 1 nos and 4. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing (Refer CE Jaipur Zone Technical Drawing no. TD/2022/01.) Make :- Shaivi or equivalent as approved by GE
S & F repair of Rain Water Downtake pipelines fixing done with Pipe Supporting Clamping System having Rain Water Bracket Set with Support + U Bolt System - Rain Water Down take pipes 4" PVC - 1 no. running Vertical Fixed line from Terrace to Ground floor with wall distance 3": Pipe Support Clamping made of 1. Rain Water Bracket Set 4" x 3" made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. and U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Rain Water Bracket Set with Support 4" x 3" and U Bolt R/M for 4" PVC Pipe Dia. - 1 No.; and 3. Justi Khilla GI coated 2 1/2" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. (Refer CE Jaipur Zone Technical Drawing no. TD/2022/01.) Make : Shaivi or equivalent as approved by GE
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specificallly provided complete all as specified and directed.
M&L for providing cement concrete (1:5:10), type E-2, using 40mm graded stone aggregate as in sunken portion of WC /toilet/ bath complete all as specified and directed.
M&L for applying two coats of flexible polymer acrylic water proofing coating, 1mm thick (Dry film in two coats) using Dr Fixit pidifin 2K of M/S Pidilite Industries or equivalent as approved by GE including necessary pond testing in sunken portion complete all as specified and directed.
Supply only integral waterproofing compound ISI marked.
JAGDAMBA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .