| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | ₹47.3 L Quoted ₹47.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹49.8 LRejected-Finance NO 7A MULLAI NAGAR MAIN RD WEST TAMBARAM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | ₹49.8 L | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | ragavbuilders L2 | Raju Builders L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed by Engineer-in-Charge. | 75 | Sqm | 36 ₹2,700 | 54 ₹4,050 |
| 2.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge. | 4.75 | Cum | 270 ₹1,282.50 | 540 ₹2,565 |
| 3.00 | M&L 25mm thick Plain Cement Concrete type B-0 (1:2:4) nominal mix using 12.5mm graded stone aggregates as in sub base complete all as specified and directed by Engineer-in-Charge. | 15 | Sqm | 126 ₹1,890 | 126 ₹1,890 |
| 4.00 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water for skirting and dado etc complete all as specified and directed by Engineer-in-Charge. | 425 | Sqm | 45 ₹19,125 | 36 ₹15,300 |
| 5.00 | M&L for rendering 15mm thick on brick/ concrete surfaces with cement mortar 1:4 as backing coat complete all as specified and directed by Engineer-in-Charge. | 90 | Sqm | 360 ₹32,400 | 270 ₹24,300 |
| 6.00 | M&L Joint free Non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a coat of Screed bed or bedding layer of mortar 15mm th for laying floor finish in CM 1:6 all as specified and directed all as specified and directed complete all as specified and directed by Engineer-in-Charge. | 15 | Sqm | 1,350 ₹20,250 | 1,260 ₹18,900 |
| 7.00 | M&L for Joint free Glazed ceramic tiles in vertical surface 350mmx250mmx7 mm/ 450mmX350mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface complete all as specified and directed by Engineer-in-Charge. | 60 | Sqm | 1,350 ₹81,000 | 1,260 ₹75,600 |
| 8.00 | M&L Light shade Vitrified ceramic tiles 9 to 10 mm thick (square / rectangular) area of each tile not exceeding 0.36 sqm but in floors set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles over a coat of Screed bed or bedding layer of mortar 15mm thick for laying floor finish in CM 1:6 complete all as specified and directed by Engineer-in-Charge. | 150 | sqm | 1,350 ₹2.0 L | 1,260 ₹1.9 L |
| 9.00 | All as per Item No.8 above but in vertical surface over a coat of rendering 10 mm thick backing coat on brick/ concrete surfaces with cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. | 15 | sqm | 1,350 ₹20,250 | 1,350 ₹20,250 |
| 10.00 | M&L PVC corner beading for wall tilling complete all as specified and directed by Engineer-in-Charge. | 15 | RM | 36 ₹540 | 45 ₹675 |
Updated dates
Tender Value
₹48.3 L
EMD Value
₹96,600
Closing Date
11 Apr 2026, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
SPL REP TO CERTAIN BUILDINGS OF GIS AT AFS TAMBARAM
2026_MES_756306_1
GE(AF)/TBM/8883/E8
Open Tender
Civil Works
180 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹96,600
Yes
16 Jun 2026
14 Mar 2026
13 Apr 2026
14 Mar 2026
11 Apr 2026
28 Mar 2026
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store and rubbish off the premisescomplete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick Plain Cement Concrete type B-0 (1:2:4) nominal mix using 12.5mm graded stone aggregates as in sub base complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water for skirting and dado etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on brick/ concrete surfaces with cement mortar 1:4 as backing coat complete all as specified and directed by Engineer-in-Charge.
M&L Joint free Non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a coat of Screed bed or bedding layer of mortar 15mm th for laying floor finish in CM 1:6 all as specified and directed all as specified and directed complete all as specified and directed by Engineer-in-Charge.
M&L for Joint free Glazed ceramic tiles in vertical surface 350mmx250mmx7 mm/ 450mmX350mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface complete all as specified and directed by Engineer-in-Charge.
M&L Light shade Vitrified ceramic tiles 9 to 10 mm thick (square / rectangular) area of each tile not exceeding 0.36 sqm but in floors set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles over a coat of Screed bed or bedding layer of mortar 15mm thick for laying floor finish in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per Item No.8 above but in vertical surface over a coat of rendering 10 mm thick backing coat on brick/ concrete surfaces with cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L PVC corner beading for wall tilling complete all as specified and directed by Engineer-in-Charge.
Demolition of Reinforced cement concrete in roof, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jallies and similar suspended work and removing debris complete all as specified and directed by Engr-in-Charge. Note : Reinforcement cut as required to facilitate demolition.
M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as directed by Engr-in-Charge. Note : Reinforcement shall be measured and paid separately.
Formwork to chullah hoods, chajjas, troughs and similar items including edges Rough finished surface of concrete Flat complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide. Rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Demolition of laid stone slabs and tiles of any description or thickness in floor removing the debris complete all as specified and directed by Engineer-in-Charge.
M & L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for Mild Steel TMT bars, 10mm dia & over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed by Engr-in-Charge
M & L for Mild steel TMT bars 8mm dia cut to length bent to shape required including cranking bending hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quions,arches, pillars, etc complete all as specified and directed by Engineer-in-Charge.
M&L for brickwork with old size sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brickwork with old size sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Removal of debris obtained from demolition/dismantling upto any distance to outside MD land upto 1.5 km complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick Plain cement concrete C-2 type (1:3:6) using 40mm graded aggregate) as in plinth protection laid in panels complete all as specified and directed by Engineer-in-Charge.
Taking down of steel tubing and connections complete on walls floors etc for 15mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
All as per item No. 25 above but bore of pipe in 20mm dia complete all as specified and directed by Engineer-in-Charge.
All as per item No. 25 above but bore of pipe in 25mm dia complete all as specified and directed by Engineer-in-Charge.
Cutting chases on brick walls, pinning in, making good to facings where required and pointing in CM 1:3 for concealed water tubing cutting not exc 10cm girth complete all as specified and directed by Engineer-in-Charge.
Supply & laying for 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
Supply & laying 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
All as per Item No.30 above but diameter of the pipe is 25 mm complete all as specified and directed by Engineer-in-Charge.
All as per Item No.30 above but diameter of the pipe is 50 mm complete all as specified and directed by Engineer-in-Charge.
Refixing of old steel tubing and connections in new or old positions (walls ceiling floors etc) bore of pipe 15mm complete all as specified and directed by Engineer-in-Charge.
Refixing of old steel tubing and connections in new or old positions (walls ceiling floors etc) bore of pipe 20mm complete all as specified and directed by Engineer-in-Charge.
Refixing of old steel tubing and connections in new or old positions (walls ceiling floors etc) bore of pipe 25mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china squatting pan of Orissa pattern size 580 x 440 mm white with P or S trap and integral foot rests (excluding flushing cistern and flush pipe) including trap set in including provision of lime cement concrete bedding complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC valveless syphonic action type low level flushing cistern 10litre capacity with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash hand basin flat back of size 550x400mm including GI Brackets, CP brass waste coupling with check nut and washers of suitable and waste pipe to be complete complete all as specified and directed by Engineer-in-Charge.
S & F in repair 15mm bore dia. pillar taps (fancy type), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge..
S&F in repairs vitreous China pedestal pattern white,(excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed by Engineer-In-Charge.
S&F in repairs vitreous china bowl urinal flat back, size of 465mm x 355mm x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm dia UPVC (SWR) floor trap with grating incl jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs grating doom 125 mm dia with or without waste hole of PTMT (minimum weight 40 gms) and fixing with gray or white cement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs flush pipe of polyethylene of low or high density or PVC 32 mm dia, for wash hand basin / urinal complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop/angle valves 15 mm bore fancy type, CP with long shank & cup (concelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop valves for 25mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore brass Chromium plated fancy type bib Taps long shank with flange, crutch or butterfly handle, screwed down , screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm dia PVC Connection 450 mm long with PTMT nuts complete all as specified and directed by Engineer-in-Charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed. Bore of Trap 32mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair 600x450 bevelled edged looking mirror 6mm thick with Design wooden frame work fitted with 6mm thick commerical ply or AC sheet backing to mirror fixed as in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair for angular two way stop cock 15 mm bore chromium plated with crtuch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union fixed all as specified and directed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 25mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Taking down rain water pipes, waste/soil pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc including cleaning or refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per item No.59 above but 110 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed complete to walls complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) Pipe single socketed in any length with rubber ring joints fixed complete to walls complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) bend with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bend with access door complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia Branch piece single (single Y) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia Branch piece single (single Y) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia branch piece double (double Y ) equal or unequal provided with acess door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia branch piece double (double Y ) equal or unequal provided with acessdoor complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) junction single (Single T ) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) junction single (Single T ) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) junction single (Double T ) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area exc 1.5 Sqm and n.exc 4.0 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
S & F for aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for windows/ Doors/Ventilators/Particians with one or more tracks including joining cleats/ channel for fixing glass/ mesh complete all as specified and directed by Engineer-in-Charge.
S & F for Aluminium powder coated (minimum thickness of powder coating 50 micron) side hung/sliding window/ ventilators shutters (I max) of aluminium section for frame work of shutters not less than 0.55 Kg/Rm including necessary jointing cleats glazing clips, rubber packing anodised aluminium snap beads, screw, roller inter locking handles including 75 mm SS Hinges-02 Nos, 125 mm handles - 01 No, 125 mm long tower bolts - 02 Nos each shutter etc.complete all as specified: Note : Glass panes and wire mesh will be measured and paid separately.
S&F for aluminium powder coated grills (pattern DG-104) weight of 2.00 to 3.20 Kg/Sqm for windows, ventilators etc including jointing, cleats etc and fixed with medium screws into walls / frame work etc complete all as specified and directed by Engineer-in-Charge.
S & F for 12 mm thick machine pressed Veneered decorative plywood, grade 1 with decorative face veneers on both faces, fixed with hidden screws to frame work if any, including edge moulding, side lipping etc complete all as specified and directed by Engineer-in-Charge.
S&F 5.5 mm thick sheet glass, ordinary quality, and sheet glass is ground or obscured or frosted on one side fixed in aluminium door/window/ventilator glazing with rubber beading complete all as specified and directed by Engineer-in-Charge.
S&F 5.5mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane for ventilator shutters complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 150mm alluminium anodised, barrel tower bolt of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Aluminium alloy, anodised sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast alluminium alloy of size 300 mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring 150mm long complete all as specified and directed by Engineer-in-Charge.
S& F in repair 300mm size mild steel ordinary rat & tail rod pattern spring (Helical) including roller & roller plate complete all as specified and directed by Engineer-in-Charge.
S&F in repair rubber beading of minimum 4mmm thickness and requisite width to be fixed at bottom of the door complete all as specified and directed by Engineer-in-Charge.
S&F in repairs door closer, aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80kg complete all as specified and directed by Engineer-in-Charge.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 Sq.m and n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
Running welding in repairs Thickness of metal to be welded n.exc 6 mm complete all as specified and directed by Engineer-in-Charge.
Welding in repairs exc 2.5cm but n exc 5cm in length for hinges in cold pressed steel door frame etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs for 75 mm brass Locks 2 levers, drawer,grade I, size 50mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Harrison rails, mild steel, chromium plated with fixing brackets,stops, rollers including all fixing works etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 in two coats (1st coat 10mm thick, finishing coat 5 mm thick with WPC @3% finished even and fair complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid water proofing compound
M&L rendering 5mm thick in CM 1:3 on as in ceiling of fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10 mm thick on brick walls with CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of newly plastered surfaces of any description over 10cm girth or width, not otherwise described of walls/pillars /cornices, after preparing the surfaces applying one coat primer, two coats of plastic emulsion paint, interior emulsion incl one coat of birla care putty (finishing smooth and glossy upto entire satisfaction of Engineer-in-charge) as per approved tint/colour with using paint brush/roller brush complete all as specified and as directed by Engineer-in-Charge. Note : The prepared surface after wall putty, the contractor will inform to the GE as well as Engineer-in-Charge for site inspection before applying further finishes. Please note that further finishes work will start only after approval of the prepared surface from the GE as well as Engineer In Charge.
M&L for preparation of New plastered ceiling surfaces and applying three coat of white wash on ceiling complete all as specified and directed by the Engr-In-Charge
M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade) complete all as specified and directed by Engineer-in-Charge.
M&L for preparing Old Steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specifed and directed by Engineer-in-Charge.
M&L Preparation of old treated wooden Surfaces of any description, over 10cm in width or girth and applying one finishing coat of varnish complete all as specifed and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of wood work exc. 10cm width or girth and applying one coat of synthetic enamel paint complete all as specifed and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of ceiling and applying one coat of white wash evenly complete all as specifed and directed by Engineer-in-Charge.
Material and labour for preparation of old painted (plastered/unplastered/concrete) surfaces of any description over 10cm girth or width, not otherwise described of walls/pillars /cornices by removing / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering after preparing the surfaces applying two coats of plastic emulsion paint, interior emulsion incl one coat of birla care putty (finishing smooth and glossy upto entire satisfaction of Engineer-in-charge) as per approved tint/colour with using paint brush/roller brush complete all as specified and as directed by Engineer-in-Charge. Note : The prepared surface after wall putty, the contractor will inform to the GE as well as Engineer-in-Charge for site inspection before applying further finishes. Please note that further finishes work will start only after approval of the prepared surface from the GE as well as Engineer In Charge.
M & L for applying one coat of alkali resistant priming paint and over of primer applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc as per existing or as approved tint/colour complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete, type D2 (1:4:8) nominal mix using 40mm graded stone aggregate as in foundations,filling and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete type B1, (1:2:4) nominal mix using 20mm graded stone aggregate) as in coping, benching and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in hard dense soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed by Engineer-in-Charge.
Removing excavated material of hard dense soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cover slab 1:2:4, type B1 (using 20mm graded aggregate) in landings, cover slabs (for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4, for manholes complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately.
M & L for Mild steel TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L in Plain cement concrete 1:3:6, Type C2 (using 40mm graded stone aggregate) for 110mm dia pipes Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in plain cement concrete 1:2:4 type B-l smooth finished, and reforming benching for 150mm dia as required complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge.
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed surface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 2mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 12mm thick perforated gypsum board of size 600mm X 600mm with rear side aluminium foil and front side PVC lamination, complete all as specified and directed by Engineer-in-Charge.
S&F for 5mm thick solid/hollow PVC wall lining consisting of wood grain printed PVC sheet used instead of plain colour sheet including dismantling of old solid PVC wall panelling and fillets complete all as specified and directed by Engineer-in-Charge.
S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall. make PVC Frame complete all as specified and directed by Engineer-in-Charge.
S&F for self adhesive water proofing flash bond membrane 100mm wide fixed to joints of AC / Ridge portion / over surfaces of galvalume roof sheets / concrete surfaces etc up to 30m height incl necessary scaffolding and removal of the same after completion of the job complete all as specified and directed by Engineer-in-Charge.
Taking down sub main wiring any description along with PVC conduit/Casing capping/wooden batten/metal conduit and made good the disturbed surface all as specified complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable DB/metal clad boxes any description or size/way including MCCB/MCBs complete all as specified and directed by Engineer-in-Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store for Servicable one for reuse & Un serviceable.one for BER process complete all as specified and directed by Engineer-in-Charge.
Hanging/Refixing only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
Taking down Exhaust fan, ceiling rose, dismantling blades and removing fan and blades to store.for Servicable one for reuse & Un serviceable.one for BER process complete all as specified and directed by Engineer-in-Charge.
Refixing only Exhaust fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fan/exhaust fan any sweep, complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed by Engineer-in-Charge.
Taking down old aluminium point wiring (light, fan, socket or power) complete fittings such as switches,sockets,ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc. complete all as specified and directed by Engineer-in-Charge.
M/L for point wiring for one light point controlled by one switch concealed type with 1.5sqmm PVC FRLS insulated,un-sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC rigid conduit not less than 20 mm dia with its accessories concealed on walls, surface on ceiling etc., with suitable clamps/ shaddles, including provision of suitable 1.6 mm thick MS pressed steel terminal boxs concealed suitable to modular sockets/switches including modular cover frame and plate in wall for housing of modular switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No.128 above but One light point controlled by Two switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.128 above but One fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.128 above but One socket point on Independent board complete all as specified and directed by Engineer-in-Charge.
All as per item No.128 above but One socket point on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per item No.128 above but with 2.5 sqmm for power point 15 amps.
All as per item No.128 above but with 4.0 sqmm for AC point socket outlet 15 amps complete all as specified and directed by Engineer-in-Charge.
S&F Modular Switch flush type, 6 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch flush type 6 Amps, Single Pole Two way complete all as specified and directed by Engineer-in-Charge.
S&F Modular Switch flush type, 16 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling rose surface PVC insulated three plates "JUMBO' type 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket outlet 2/3 pin 6 amps 240 volts flush type. Two module complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket out let 6/16 Amp 6pin flush type Two module complete all as specified and directed by Engineer-in-Charge.
S&F Modular Fan regulator electronic type with 5 step control suitable for 1200/1400 mm ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 22 W LED (4 feet) lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F LED lights fitting 1x 22W, 220V, Suspended architectural LED luminare provides soft-light and glare free symmetrical illumination with (continuous mounting end cap connecting up with three core flexible copper conductor including disconecting, removing and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Mirror light fitting LED luminares New generation energy saving IP65 Mirror light luminaire with opal diffuser with 10W LED including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35W LED 5000K lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket all as directed complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings steps, chills, sunshades, shelves, lintels etc and cutting chases for concealed conduit wiring etc. and making good cutting exceeding 10cm but not exceeding 20cm girth complete complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring two run of 4 sqmm single core PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring two run of 6 sqmm single core PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring four run of 10 sqmm single core PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 10 sqmm PVC insulated copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections all as directed by Engr in charge for AC complete all as specified and directed by Engineer-in-Charge.
Refixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections all as directed by Engr in charge for AC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 8 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 12 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections all as directed by Engr in charge.
Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door type including 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections all as directed by Engr in charge.
Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 8 ways double door type including 125 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections all as directed by Engr in charge.
S & F MCB's 6-32/40 amps, 10 KA , SP 240V complete all as specified and directed by Engineer-in-Charge.
S & F MCB's B curve SPN 6-32/40 Amps, 10 KA , 240V complete all as specified and directed by Engineer-in-Charge.
S & F for isolator TP 63Amps, 10 KA , 240V complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling fans 1200 mm sweep 230 V AC 50 HZ complete with down rod complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4.0 mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4.0 mm thick for inter connecting of earth electrodes complete all as specified and directed by Engineer-in-Charge.
S&F PVC non metallic rigid conduit not less than 20 mm dia with its conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
M&L Ceiling fan hook made out of MS bar 10 mm dia bar bend to shape or anchor fastener with hook for shifting/hanging ceiling fans complete all as specified and directed by Engineer-in-Charge.
Taking down Split AC up to 2.0Ton complete with indoor & out door units and deposit to E/m store for safe custody including electrical connections complete all as specified and directed by Engineer-in-Charge.
M&L for refixing the split AC up to 2.0Ton colecting from E/M store after completed the B/R work including necessary servicing, gas top up & replacement of minor spares if required complete all as specified and directed by Engineer-in-Charge.
Refixing of LED/CFL light fittings any type including treplace the necessary connections complete all as specified and directed by Engineer-in-Charge.
Supply and fix wall mounted fan 450 mm sweep esteem type along with speed control complete with all accessories incl mounting fabricated MS flat and anchor fastner nuts and bolts all as per design given by Engr-in-Charge all as directed including taking down the US fan and deposited to E/M store for BER process complete all as specified and directed by Engineer-in-Charge.
Refixing of wall mounted fan 450 mm sweep esteem type along with speed control complete with all accessories incl mounting fabricated MS flat and anchor fastner nuts and bolts all as per design given by Engr-in-Charge all as directed after complete the B/R work including taking down the fan and serviceing with replace the minor spares complete all as specified and directed by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender8883.pdf
Tender Documents • 0.66 MB
PS8883.pdf
Additional Documents • 0.58 MB
BOQ_847167.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid