| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.9 L+₹1.0 L (3.58%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹34.9 L+₹6.0 L (20.8%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹45.5 L+₹16.6 L (57.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹46.5 L+₹17.6 L (60.8%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
25 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-27/2022-23 REPAIR, REPLACEMENT OF LT EQUIPMENT, CONTROL GEAR, AND STABILIZER ALONGWITH CONNECTED WORKS OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT AF STN PALAM UNDER GE (P) AF GURGAON.
2022_MES_527168_1
GE (P) AF/Gur-27/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹90,000
Yes
2 Aug 2022
28 May 2022
27 Jun 2022
28 May 2022
25 Jun 2022
11 Jun 2022
Amount
Disconnection/ taking down fully existing unserviceable LT Panel board/ feeder pillar box any type and capacity including all control switches, fittings and fixtures from different location including disconnection of existing incoming and outgoing electric cable and dismantling of PCC platform and make good with existing surface complete all as directed by Engineer-in-Charge.
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (SMQ P-81 Block) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING : (a) MCCB four pole 400 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . (b) MCCB four pole 320 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos (c) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos .
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: Near RO Plant for Airmen Mess) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING : (a) MCCB four pole 320 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos .
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: Main Guard Room) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING :- (a) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos . (b) MCCB four pole 100 Amps, 16 KA at 415 Volts, adjustable thermal and magnetic setting- 04 Nos .
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: Tech HQ) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING :- (a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos . (b) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: for IT Flt near comn lab) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING :- (a) MCCB four pole 250 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . (b) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-04 Nos
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: Near Tech HQ) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING ; (a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos .
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: SNCO's Mess) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING : (a) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 03 Nos . (b) MCCB four pole 160 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-02 Nos (c) MCCB four pole 100 Amps, 16 KA at 415 Volts, adjustable thermal and magnetic setting-01Nos
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :- (Location: LLL R) Make of panel :- Conelec Systems/Tricolite/Mc Layer/universal switchgear / Advance Switchgear
OUT GOING ; (a) MCCB four pole 200 Amps, 25 KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . (b) MCCB four pole 160 Amps, 25 KA at 415 Volts, adjustable thermal and magnetic setting-03Nos (c) MCCB four pole 100 Amps, 25 KA at 415 Volts, adjustable thermal and magnetic setting-01Nos
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 15 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid for separatly as "supply only' under relavant item )
Supply only the following for 15 KVA stabilizer :-
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 25 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid for separatly as "supply only' under relavant item )
Supply only the following for 25KVA Stabilizer
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 450 KVA to 500 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid for separatly as "supply only' under relavant item )
Supply only the following for 450 to 500 KVA Stabilizer :-
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 400 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid for separatly as "supply only' under relavant item )
Supply only the following for 25KVA Stabilizer :-
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Repair to voltage stabilizer automatic oil cooled 3 phase 4 wire AC supply servo controlled 440 V, 300 KVA unbalanced type by disconnecting incoming and outgoing connections, reconnecting with suitable cable lugs , replacement of worn out wiring with copper cable including soldering of joints and providing sleaves, opening the top cover and replacement of top rubber gasket, bushing, rubber gasket, seal etc including including replacement of defective / warnout parts such as gear assemble , replacement of servo motor , carbon roller assemble, pcb, toggle switch, control transformer, indicatiing lamp, voltmeter, preston type switch by new spares including testing and commissioning all as directed. including dismantling and disconnecting of LT cables and refixing after repairing of stabliziser13 BRD and testing commissioning of the stabilizer on full load to the entire satisfication of Engr-in-Charge). (Note- Spare parts will be measured and paid for separatly as "supply only' under relavant item )
Supply only the following for 160 KVA DG set :-
(a) Gear Assembly
(b) Replacement of servomotor (02 Nos) 10 KG/CM torque
(c) Replacement of carbon roller assembly
(d) Replacement of PCB
(e) High low voltage cut off
(f) Toggle switch
(g) Control transformer
(h) Replacement of indicating lamps complete
(k) Preston type switch
(l) Voltmer
(m) Ampere meter with CT
Dehydration/filtration of stabilizer and other lt equipment oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 40 KV at 2.5 mm gap in existing position of transformer/stabilizer of any capacity and transformer oil for topping up at various sub station complete all specified and as directed. NOTE: Transformer oil for TOP UP shall be measured and paid separately under respective item of this schedule
Supply only transformer oil of approved quality (Dielectric strength not less than 40 KV) ISI marked for filling in transformer for topping up all as directed by Engr-in-Charge. Note : Factory sealed container of transformer oil will be accepted.
M&L for rewinding of burnt out LT dimmerstate/coils of three phase servo stabilizer of capacity 15 KVA to 1500 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , colding/drying etc complete all as specified and directed.
Taking down/dismantling and refixing of any capacity of stabilizer/LT equipments by using Hydra mechine/suitable crane complete and including tranportation shifting to approved manufacturer/Workshop including testing and commissioning all as directed. (Note- Dismantling and disconnecting HT cable and LT cables and refixing after rewinding and Transportation from 13 BRD to Workshop and workshop to 13 BRD will be paid as one job)
M&L for painting of servo stabilizer after cleaning the body surface of stabilizer by rubbing with emery Ppper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray paint incl writing SM No/MES No , capacity of stabilizer of following capacity all as directed by Engr-in-Charge. The contractor has to arrange their own local generator for supply to the spray painting machine.
15 KVA to 25 KVA
300 KVA to 400 KVA
450 KVA to 500 KVA
M&L for spray painting to LT panel board complete from inner and outer side with one coat of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces and welding work as required complete all as specified and directed including disconnection of supply from main comlete all as specified and directed. (approximate 8 sq mtr of each panel board ) Make - Asian paints /Berger Paints/Neroac Paints
8. M & L for welding of Panel door inner and outer and MCCB doors from front and back with necessary hinges & locking arrangements including properly disconnection of old unserviceable parts, MS sheet and angle irom complete & locking arrangements including replacement of followings (Note MS Sheet and angle iron will be measured and paid separated.
Supply and fix in replacement of MS sheet duly powder coated for enclosing the feeder pillar box of any size inclding taking down old rusted MS sheet complete all as specified and directed.
Supply and fix in replacement of MS Angle irom of size 50x50x50x6 and 40x40x6 mm sheet duly painted for bracing the sheet and also give the structure for the feeder of any size inclding taking down old rusted MS angle complete all as specified and directed.
Supply and laying of round boulders of gauge 63 mm graded as in bedding layer around electrical equipment or installation ,LT Panel etc complete all as specified and directed.
Supply and fixing of busbar in repair for giving common output including taking down old U/S busbars from panel of alluminium strap suitable for LT suppy 415 volts , 4 winding system including making necessary cable connection for making hole in busbar complete all as specified and directed by Engr-in-Charge.
Supply and fixing of busbar in repair for giving common output including taking down old U/S busbars from panel of copper strap suitable for LT suppy 415 volts , 4 winding system including making necessary cable connection for making hole in busbar complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair busbar insulator to insulating the bar from pillar box suitable for 415 volts AC supply insulation complete all as specified and directed
Repair/maintenance of 30 KVA UPS by dignostics the problem and replacement of unserviceable PCB, and rewiring of defective internal wiring complete all as specified , callibration of charger and testing and commissioning after replacement of all minor defective parts like PCB, internal wiring, relay will be deemed in the cost of items and connection with battery bank compete all as specified and directed. (Note : Battery bank will be measured and paid seperately under respective items of schedule)
Supply and fix in replcement battery bank of capacity 360 V, consisting of (30 Nos) of 12 Volts Each 65 AH maintenance free "exide" make for system voltage 24 V, including disconnection of old U/S Battery bank complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 3 pole, capacity 100 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F in replacement of MCCB 4 pole, capacity 100 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F in replacement of MCCB 3 pole, capacity 125 Amps with breaking capacity 16 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F in replacement of MCCB 4 pole, capacity 125 Amps with breaking capacity 16KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand
S&F in replacement of MCCB 3 pole,capacity 200 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 4 pole,capacity 200 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 4 pole,capacity 250 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 4 pole, capacity 350 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixe complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 4 pole, capacity 400 Amps with breaking capacity 36KA, overload setting adjustable and short circuit setting fixe complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testingall as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 4 pole, capacity 630 Amps with breaking capacity 50KA, overload setting adjustable and short circuit setting fixe complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testingall as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
S&F in replacement of MCCB 3 pole, capacity 160 Amps with breaking capacity 36 KA, overload setting adjustable and short circuit setting fixed complete with necessary modifications in Panel Board for connection of MCCBs complete all as directed including disconnecting UNSV MCCBs Connecting and testing all as specified and as directed. Make:- Havells/ Indoasian/ ABB/Legrand.
Taking down old unserviceable distribution board of any size and any capacity . Note : (i) Old dismantled wiring and accessaries will be contractors property and credit will be charged against schedule of credit.
Supply and fixing sheet metal enclosure double metal door factory made TPN 415 volt 4 way suitable for fixing MCB as outgoing and MCCB TP 63 to 125 Amps 16 KA as main incoming duly painted all as specified in cat No. DBVTL004DD of L&T or equivallent including necessary electrical connection and flush in wall with necessary pcc works and make good the distrubed surface with existing surface complete all as specified and directed.
-ditto- but SP 5 to 32 Amps ,240 Volts. Make Legrand 603234 or equivallent Havells/Schneider
S&F in replacement of Air Circuit breaker of capacity uptu 4 pole Microprocessor released type Drawout type of capacity 630 Amps as per existing model & make complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Air Circuit breaker of capacity uptu 4 pole Microprocessor released type Drawout type of capacity 800 Amps as per existing model & make complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Air Circuit breaker of capacity uptu 4 pole Microprocessor released type Drawout type of capacity 1000 Amps as per existing model & make complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Air Circuit breaker of capacity uptu 4 pole Microprocessor released type Drawout type of capacity 1250 Amps as per existing model & make complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Air Circuit breaker of capacity uptu 4 pole Microprocessor released type Drawout type of capacity 2500 Amps as per existing model & make complete all as specified and as directed by Engineer-in-charge.
S&F On /off load Change over switch with sheet enclosure type 200 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed.
S&F On /off load Change over switch with sheet enclosure type 400 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed.
S&F On /off load Change over switch with sheet enclosure type 630 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed.
S&F On /off load Change over switch with sheet enclosure type 1000 amps 4 pole 415 Volts including taking out of unserviceable one complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion
Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4 mm galvanised iron strip
Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 20X3 mm copper strip
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and as directed for foundation of stay, laying of cable etc.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection all as specified.
M&L for sand filling in trenches for cushioning of cable complete all as specified and directed.
M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level)
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc all as specified and as directed.
Taking up old serviceable/ UG cable from trench for replacement, repair and re-laying or re-routing of size 70 sqmm to 95 Sqmm 3.5 core complete all as directed.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminum conductor 1100 volts grade with cross sectional area of the following size 70Sqmm 3.5 core with screened, pvc bedded, galvanized steel strip or wire including laying in trench, passing through pipe, bone and road and complete all as specified and directed by engr-in-charge.
Material and labour for XLPE insulated armoured heavy duty electric cable with aluminum conductor 1100 volts grade with cross sectional area of the following size 95 Sqmm 3.5 core with screened, pvc bedded, galvanized steel strip or wire including laying in trench, passing through pipe, bore and road and clamping on wall with clamp at a gap of 02 feet complete all as specified and directed by engr-in-charge.
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure.
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth.
S & F GI tubing 40 mm dia light grade in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc all as directed.
Notes:- (a) The amount of Rs. 371118/- against Schedule of Credit on Page No. 129 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) As contract is maintenance nature the site shall be handed over in pieces as per site availability from users.
YASHVI ENGINEERS
M/s Adhikari construction co.
M/S Anand Enterprises
SM CONSTRUCTION COMPANY
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .