Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.5 L
EMD Value
₹24,100
Closing Date
25 Jul 2022, 11:00 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Improvement and development of E.I at Community Hall at Krishna market kalkaji in ward no-90S under central zone in SDMC.
2022_SDMC_122638_1
EE(Elect.)/CNZ/2022-23/18-02
Open Tender
Electrical Works
Item Rate
60 days
Krishna Market war no.90-S
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹24,100
28 Jul 2022
16 Jul 2022
25 Jul 2022
16 Jul 2022
25 Jul 2022
16 Jul 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm).
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 module (125mm x125 mm).
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 12 module (200mmX150mm).
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 63 amps
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Installation of exhaust fan in the existing opening ,including making good the damage, connection, testing ,commissioning etc.as required Up to 450 mm sweep
Supply ,Installation, Testing and Commissioning of 1200mm sweeep, BEE 5 Star rated , ceiling fan with Brush Less direct current (BLDC) Motor , class of insulation:B, 3 nos blades , 30cm long down rod , 2nos. Canopies , shackle kit , safety rope, copper winding, power factor not less than 0.9 , service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350RPM (tolerance as per IS: 374-2019) , THD less than 10% , remote or electronic regulator unit for speed control and all remaining accessories including safety pin , nut bolts , washers, temperature rise=75 degree C (Max.), insulation resistance more than 2 mega ohm, suitable for 230V ,50Hz, single phase AC supply , earthing etc. complete as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supply of 12'' ( 300 mm )sweep 1400 RPM exhaust fan heavy duty complete with shutter,blade etc as required.
S.I.T.C of LED Tube type Luminaire 20W rating complete with polycarbonate housing batten integrated electronics driver prewired with high efficient LEDs with the following : (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95
SITC of 60W LED Flood light luminiare fitted with lens ,made of pressure die cast aluminium housing & toughened glass cover complete with following specification as required with IP 66 protection.(a) Total system wattage=60 watt+/-5%. (b) Luminiaire effiency >=100Lm/w.(c) power factor >=0.95.(f) Protection class -IP-66
P/F Hot press sheet moulded compound (SMC) fire retardent (Temp. resistance upto 200 degree c),IP55 waether proof pole box of inner dimension 200x160x98mm complete with suitable arrangement for fixing of 2 nos of 6A to 32A single pole MCB & 63A double pole isolator (MCB/isolator excluded )with neutarl link duly shorting on DIN channel with 2 nos of MS clamps with SS back plate of suitable size with danger monogram properly printed on the cover etc as required.
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured cable 1.1KV grade confirmig to IS-7098 of following size 4 core 25sq mm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured cable 1.1KV grade confirmig to IS-7098 of following size .3x10sq mm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured cable 1.1KV grade confirmig to IS-7098 of following size .2x10sq mm
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 3x2.5 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
Earthing with GI earth pipe 4.5 metre long ,40 mm dia including accessories,and providing massonary encloser with cover plate having locking arrangement and watering pipe etc.with charcoal /cock and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with surface/recessed conduit/submain wiring/cable as required.
S/F installation of cubical panel board 16 SWG sheet M.S depth 30 cm to 60 cm with A1. bus bar and interconnection suitable for switch gears i/c and making foundation etc as required.
Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Fabrication,supply & errection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate hight from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4 mm thick of suitable length and having suitable size tapped holes as reqd., terminal block suitable for 25 sqmm conductor-4 nos & shorting links on DIN channel i/c pdg and fixing DIN channel of suitable lenth,6 amps SP MCB "c" characteristics,earth stud,cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.( a) 5.o mtr. hight,3 mm thick,bottom dia of 130 mm & top dia of 70 mm, base plate of size 225 mm x 225 mm x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L)x450 mm wide and 1000 deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long (approx)-8 nos . and reinforcement of cold twisted bars of 8 mm dia 1400 mm (approx) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 no. foundation bolts of size 16 mm dia ,600 mm long, J type i/c 2 nos. template anchor plates of size 225 mm X 225 mm X 3 mm and providing 63mm dia DCW, HDPE for cable entry and exit as required for 3 mtr and 5 mtr pole.
Fabrication, supplying and fixing class B galvanised Single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
Fabrication, supplying and fixing class B galvanised Double overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .