Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC since L1 | |
| 2 | L2₹10.6 L+₹56,343 (5.60%)Rejected-Finance AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Since not L1 | |
| 3 | L3₹11.0 L+₹97,683 (9.72%)Rejected-Finance AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L3 | Rejected-Finance Since not L1 | |
| 4 | L4₹11.5 L+₹1.5 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Since not L1 | |
| 5 | L5₹12.0 L+₹1.9 L (19.2%)Rejected-Finance AT NUAGARH PO BARKUL DISTT KHURDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L5 | Rejected-Finance Since not L1 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
20 Feb 2020, 6:00 pmClosed
GE CHILKA
GE CHILKA, INS CHILKA, KHURDA, ODISHA 752 037
SPECIAL REPAIR TO POINT WIRING AND DISTRIBUTION SYSTEM OF 200 MEN BLOCK AND MANU BLOCK AT INS CHILKA UNDER GE CHILKA
2020_MES_313237_1
GE/CHL/8626 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GE CHILKA
MES Enlisted contractor of Class E category b(i)
7 documents required · 7 mandatory
₹500
GE CHILKA
₹26,000
Yes
28 Mar 2020
9 Jan 2020
25 Feb 2020
9 Jan 2020
20 Feb 2020
24 Jan 2020
9 Jan 2020 - 16 Jan 2020
Amount
Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches, sockets, ceiling rose , lamp holder, tube light fittings and making good distrubed surfaces of walls or ceiling etc to match with the existing complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm PVC FRLS insulated unsheathed multistranded copper cable with 1.5 sqmm PVC FRLS insulated multistranded copper cable as earth continuity drawn in including stove enamelled steel conduit dia not less than 20mm dia including pressed mild steel concealed box made out of 1.6 mm thick sheet duly covered with 3 mm thick plastic laminated sheet for mounting switches/sockets, accessories such as spacers, saddles, junction boxes for one light / fan point / bell point/5 amp socket controlled by one switch complete all as specified and as directed.
All as per item No 2 above but for one light point controlled by two 2-way switches complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm PVC FRLS insulated unsheathed multistranded copper cable with 1.5 sqmm PVC FRLS insulated multistranded copper cable as earth continuity drawn in including PVC casing & caping width not less than 20mm dia including pressed mild steel concealed box made out of 1.6 mm thick sheet duly covered with 3 mm thick plastic laminated sheet for mounting switches/sockets, accessories such as spacers, saddles, junction boxes for one light / fan point / bell point/5 amp socket controlled by one switch complete all as specified and as directed.
All as per item No 4 above but with 2.5 sqmm PVC FRLS insulated unsheathed multistranded copper cable with 2.5 sqmm PVC FRLS insulated multistranded copper cable as earth continuity for power socket on independent board complete all as specified and as directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall,ceiling and making good surfaces to match with existing complete all as specified and as directed.
M&L for sub main wiring with two runs of 4sqmm PVC FRLS insulated unsheathed multistranded copper cable 1100 Volt and one run of 4sqmm PVC FRLS insulated unsheated multistranded copper cable as earth continuity conductor drawn in including surface casing-caping not less than 25mm wide complete all as specified and as directed. Note:- 2 runs of 4 Sqmm, 1 run of 4.0 Sqmm copper earth wire and 1 run of PVC casing & caping shall be measured as one unit length.
M&L for sub main wiring with two runs of 6 sqmm PVC FRLS insulated unsheathed multistranded copper cable 1100 Volt and one run of 4 sqmm PVC FRLS insulated unsheated multistranded copper cable as earth continuity conductor drawn in including surface casing-caping not less than 25mm wide complete all as specified and as directed. Note:- 2 runs of 6 Sqmm, 1 run of 4.0 Sqmm copper earth wire and 1 run of PVC casing & caping shall be measured as one unit length.
M&L for sub main wiring with four runs of 6 sqmm PVC FRLS insulated unsheathed multistranded copper cable 1100 Volt and two run of 4 sqmm PVC FRLS insulated unsheated multistranded copper cable as earth continuity conductor drawn in including surface casing-caping not less than 25mm wide complete all as specified and as directed. NOTE:- 4 runs of 6 Sqmm, 2 run of 4.0 Sqmm copper earth wire and 1 run of PVC casing & caping shall be measured as one unit length.
S&F switch paino, flush type, single pole, one way, 5/6 Amp complete all as specified and as directed.
S&F switch paino, flush type, single pole, two way, 5/6 Amp complete all as specified and as directed.
S&F switch socket combination 2 in 1 , 5 Amps flush type, 230V complete all as specified and as directed.
S&F switch socket combination 2 in 1 ,3 pin, 6/16 Amps flush type, 230V complete all as specified and as directed.
S&F sheet metal single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and as directed.
S&F ceiling rose , 3 phase, PVC/polycarbonate, isolated body,230V including PVC mounting box of size not less than 3inchX3inch round type complete all as specified and as directed.
S&F stepped type electronic type fan regulator flush type on existing laminated sheet complete all as specified and as directed.
Taking down existing exhaust fan and wall mounted fan from its position and refixing the same after cleaning and necessary minor repairs to made functional inlcuding necessary connection and testing complete all as specified and as directed.
M&L for spray painting to ceiling fan with blade complete, in situ with one coat of approved synthetic enamel paint including filling cavities with filler after cleaning all dust, dirt etc complete all as specified and as directed.
Taking down existing ceiling fan from its position and refixing the same after cleaning and minor repair to made functional complete all as specified and as directed.
Taking down existing serviceable LED light fitting and refixing the same after completion of work complete all as specified and as directed.
S&F LED Downlighter 12 Watt AC, 230 volt as per site requirement complete all as specified and as directed. Make:- Bajaj Cat part No. BPSLR 12W NW or equivalent in Havells or Crompton Greaves as approved.
Taking down carefully old unserviceable MCB DBs any type by unscrewing from wall or on boards including making good to existing surfaces to match with existing work complete all as specified and as directed.
S&F of sheet metal enclosure single pole and neutral 12 way with 200 amps rated bus bar, 240 Volts, double door complete all as specified and as directed.
S&F of sheet metal enclosure single pole and neutral 8 way with 200 amps rated bus bar, 240 Volts, double door complete all as specified and as directed.
S&F of MCB single pole 6 to 32 amps, C-series , 240 Volt complete all as specified and as directed.
S&F of MCB single pole and neutral, 40 amps, C-series, 240 Volts complete all as specified and as directed.
S&F in replacement of sheet metal enclosure triple pole and neutral 4 way with 200 amps rated bus bar, 415 Volts, double door complete all as specified and as directed.
Taking down carefully existing old unserviceable MCB any type and of any make by unscrewing complete all as specified and as directed.
S&F MCB, four pole 100 amps , C-series,415 Volt, 50 Hz complete all as specified and as directed.
S&F MCB four pole 63 amps, C-series, 415 volt, 50 Hz complete all as specified and as directed.
S&F vertical distribution boards with MCCB, 8 way with provision of triple pole MCCB 250 Amps , 36 KA as incomer complete all as specified and as directed.
S&F in replacement of MCCB 200 Amps, 36 KA ,4 pole, 415 Volts, 50 Hz complete all as specified and as directed. Make:- Havells/HPL/Legrand/C&S
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, reinforced, with 8mm dia TMT bar at 150mm c/c both ways, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
PRASANTA KUMAR PANDA
Likitha Enterprises
MCC MECHANICAL AND ENGINEERING CORPORATION
SAHADEV PALAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .