Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.8 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹66.8 L Quoted ₹67.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹73.0 L+₹5.8 L (8.67%)Rejected-AOC | ₹73.0 L+₹5.8 L (8.67%) | L2 | Rejected-AOC L2 |
| 3 | L3₹75.2 L+₹8.0 L (11.9%)Rejected-AOC | ₹75.2 L+₹8.0 L (11.9%) | L3 | Rejected-AOC L3 |
| 4 | L4₹75.8 L+₹8.6 L (12.8%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹75.8 L+₹8.6 L (12.8%) | L4 | Rejected-AOC L4 |
| 5 | L5₹80.2 L+₹13.0 L (19.4%)Rejected-AOC | ₹80.2 L+₹13.0 L (19.4%) | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
10 Aug 2021, 6:00 pmClosed
SH A P SINGH, IDSE, SE
HQ CWE CHANDIMANDIR
CA NO CWE/CHM(U)-34/2021-22 SPL REPAIR/ REPLACEMENT OF LT PANEL, BER TRANSFORMERS, CONVERSION OF OH CONDUCTOR TO UG CABLE AND ALLIED WORK AT WCCSR AND CHANDIMANDIR MIL STN AND AUGMENTATION OF POWER SUPPLY AT DEPENDENT AREA OF SUB STN NO 7
2021_MES_457297_1
CWE/CHM(U)-34/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
Class C cat b (ii)
8 documents required · 8 mandatory
₹1,000
Yes
GE (U) CHANDIMANDIR
₹1.6 L
Yes
28 Sept 2021
5 Jul 2021
12 Aug 2021
5 Jul 2021
10 Aug 2021
27 Jul 2021
Amount
Suppy, installing, connecting, commissioning and testing of energy effficient transformer (level 3 of IS 1180) 5 star rating , of capacity 315 KVA indoor type, step down 11/0.433 KV, core type oil immersed, copper wound, natural oil cooled with external cooling tubes/radiators, having 3 phase 50 Hz AC supply, DYn-11 design, off load tap changer on HT side to vary secondary voltage ±7.5% in steps of 2.5% as per IS 1180 (Pt-I to III) with all standerd accessories including HT and LT bushing, cable box on LT and HT side, including first filling of new transformer oil (of di-electric strength not less than 50 KV) upto required level in conservator tank complete all as specified and as directed by Engr-in-Charge with and including the following :- (a) One No 100 mm dia, dial type thermometer with resetting device vapour pressure type having range 0 to 120 degree centigrade. (b) Rating plate and terminal marking plate. (c) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing..
(d) Oil level gauge with max & min level marking. (e) Oil filter valve. (f) Oil drain valve. (g) Lifting hooks. (h) Oil conservator with filling hole and cap. (j) Air relief valve plug. (k) Four solid cast steel detachable rollers. (l) Earth bushing for neutral outside the LT cable box for providing independent earthing for neutral. (m) Clear view type silica gel breather with first fill of fresh bluish color silica gel. Note. The transformer should be 5 Star rating and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer.
All as per item No 1 here in before but capacity 400 KVA.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 185 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete all as specified and directed.
Supply, laying, jointing and testing LT underground cable XLPE insulated , PVC sheathed, armoured heavy duty and 1100 volts grade with multistranded aluminium conductor of size 240 sqmm 3.5 core in trenches/ducts/through pipes/under culverts etc complete all as specified and directed.
S & F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 95 sqmm 3 core, 11 KV earthed, complete all as specified.
Supply and fix HT heat shrinkable type cable jointing kit for 11 KV grade cable for indoor termination, complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 95 sqmm complete all as specified.
Supply and fix HT heat shrinkable type cable jointing kit for 11 KV grade cable for outdoor termination, complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 95 sqmm complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point/ panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge with and including including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Supply, installation, testing and commissioning of CPRI approved make outdoor type double door panel board suitable for floor mounting size not less than 1200 x 1200 x 450 mm , with locking arrangement , fabricated out of 3.15 mm thick CRCA sheet and MC 75 for base frame, 50x50x6 mm angle iron legs 750 mm long 04 Nos (grouted in PCC 1:2:4 type B-I using 20mm graded crushed stone aggregate as directed, dully powder coated , dust/water & vermin proof , suitable for 415 volts 3 phase 50 Hz , complete with and incl the following accessories :- (a) MCCB FP 630 amps capacity 35/36 KA 415 volts with adjustable thermal & magnetic release and Ics = 100 % of Icu - 01 No (Incoming) (b) Aluminium strip bus bars sleeve insultaed and mounted on epoxy insulators, 1000 amps capacity, TPN - 01 set (c) MCCB FP 250 amps 35 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu -01 Nos and MCCB FP 200 amps 35 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu -03 Nos (Outgoings) (d) LED type indicators RYB - 01 set.
Supply, installation, testing and commissioning of CPRI approved make outdoor type double door panel board suitable for floor mounting size not less than 1200x1200x450 mm, with locking arrangement, fabricated out of 3.15 mm thick CRCA sheet and MC 75 for base frame, 50x6 mm angle iron legs 750 mm long 04 Nos grouted in PCC 1:2:4 as directed, dully powder coated, dust/water & vermin proof , suitable for 415 volts 3 phase 50 Hz, complete with and incl the following accessories:-(a) MCCB FP 630 amps capacity 35/36 KA 415 volts with adjustable thermal & magnetic release and Ics=100 % of Icu - 01 No (Incoming) (b) Aluminium strip bus bars sleeve insultaed and mounted on epoxy insulators, 1000 amps capacity, TPN - 01 set (c) MCCB FP 200 amps 35 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu -02 Nos and MCCB FP 160 amps 35 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu -02 Nos (Outgoings) (d) LED type indicators RYB - 01 set. (e) LT CTs 630/5 amps - 03 Nos
Excavation in trenches in hard/dense soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for laying of cable, poles etc and getting out complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil complete all as specified.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as directed.
M & L dry sand filling under and around UG cable to provide cushioning to cable complete all as specified and directed. Note. Punned thickness shall be measured.
Suply and laying unreinforced precast concrete cable cover (ISI Marked), class LV, type-I, flat, size 250mm x 150mm x 40mm, in trenches over sand as protection to cable complete all as specified and as directed.
M & L tubes 80 mm bore, light grade galvanized steel with fittings and MS clamp, nut, bolts etc fixed for cable protection on poles/walls/under road/culvert etc complete all as directed.
Dismantling old over head ACSR conductors and earth wire any size from over head lines on poles and removing from site complete all as specified and as directed.
Dismantling old structural steel or MS work like old cross arms, channel/ angles sections or bracings nuts bolts washers etc from elelctric poles, any position and removing from site complete all as specified and directed.
Dismantling old insulators any type and any size from OH electric poles and removing from site complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified and as directed.
Supply, installation, testing and commissioning of out door type CPRI approvd LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11 . Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of board/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation) The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu -01 Nos (b) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . (c) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . (d) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type CPRI approvd LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel (1.10 X 1.875 X 0.60 m ) shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11 including taking down of old unsv/ rusted LT panel. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of rotection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation) The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu -01 Nos (c) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 Nos . (d) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 04 Nos . (e) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (f) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type CPRI approvd LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel (1.10 X 1.875 X 0.60 m ) shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation) The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu -01 Nos. (b) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 03 Nos. (c) MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 02 Nos. (d) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type CPRI approvd LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel (1.10 X 1.875 X 0.60 m ) shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation) The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 320 Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu -01 Nos (b) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based with LIG&LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 04 Nos . (c) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (d) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation testing and commissioning of out door type LT feeder piller box CPRI approved openable from front & rear double door type,dust and vermin proof, fabricated out of 3.15 mm CRCA sheet of size not less than 0.75 x 0.50 x 0.50 duly painted with two coats of powder coated of approved shade over a coat of zinc chrome primer and MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6mm for grouting purpose and grouted in PCC 1:2:4 type B1(using 20 mm graded stone aggregate) alongwith incoming MCCB four pole, 415 volts, 25 KA, 50 Hz, 200 amps - 01 Nos including 4 Nos heat shrink insulated 200 Amps rated aluminum bus bar suitable for 6 Nos outgoing 25 sqmm to 35 sqmm 3.5/4 core XLPE armoured cable complete all as specified and directed by Engr-in- charge.
M&L for boring/drilling by machines/manual horizontally under the road in any type of soil without cuttiing/disturbing the existing road and inserting GI pipe of size 80 to 100 mm for drawing the cable complete all as specified.(GI pipe shall be measured and paid seperately.
Suppy, installing, connecting, commissioning and testing of energy effficient transformer (level 3 of IS 1180) 5 star rating , of capacity 200 KVA outdoor type, step down 11/0.433 KV, core type oil immersed, copper wound, natural oil cooled with external cooling tubes/radiators, having 3 phase 50 Hz, AC supply, DYn-11 design, off load tap changer on HT side to vary secondary voltage ±7.5% in steps of 2.5% as per IS 1180 (Pt-I to III) with all standerd accessories including HT and LT bushing, cable box on LT side, including first filling of new transformer oil (of di-electric strength not less than 50 KV) upto required level in conservator tank complete all as specified and as directed by Engr-in-Charge with and including the following :- (a) One No 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade. (b) Rating plate and terminal marking plate. (c) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (d) Oil level gauge with max & min level marking.
(e) Oil drain & filter valve. (f) Lifting hooks. (g) Oil conservator with filling hole and cap. (h) Air relief valve plug. (j) Four solid cast steel detachable rollers. (k) Earth bushing for neutral outside the LT cable box for providing independent earthing for neutral. (l) Clear view type silica gel breather with first fill of fresh bluish color silica gel. Note. The transformer should be 5 Star rating and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer.
M & L cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.
S & F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified. Note - Earthwork, foundation concrete etc shall be measured & paid separately.
Supply, installation, testing and commissioning of outdoor type CPRI approved make double door panel board suitable for floor mounting size not less than 1200 x 1200 x 450 mm , with locking arrangement , fabricated out of 3.15 mm thick CRCA sheet and MC 75 for base frame & angle iron 50 x 50 x 6 mm size for legs , 04 nos legs 750 mm long, PCC 1:2:4 type B-1 for grouting, dully powder coated , dust/water & vermin proof , suitable for 415 volts 3 phase 50 Hz , complete with and incl the following accessories :- (a) MCCB FP 315 amps capacity 35/36 KA 415 volts with adjustable thermal & magnetic release and Ics = 100 % of Icu - 01 No (Incoming) (b) Aluminium strip bus bars sleeve insultaed and mounted on epoxy insulators, 600 amps capacity, TPN - 01 set (c) MCCB TP 160 amps 35/36 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu -02 Nos and MCCB TP 63 Amps 25 KA 415 Volts with adjustable thermal & magnetic release and Ics = 100 % of Icu- 04 No (Outgoing) (d) LED type indicators RYB - 01 set. (e) Multifunctional meter 96 x 96 mm size flush mounting digital type - 01 No (f) Earthing terminals - 02 Nos. (g) Danger notice plate dully rivetted/pasted on front door - 01 No (h) Internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suitable dia incl control MCB SP in each circuit.
Excavation in trenches in hard/dense soil exc 1.5m n.exc 3.0 metre in depth, for laying of cable, poles etc and getting out complete all as specified.
M & L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified.
M & L PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping with and including necessary form work complete all as specified and directed.
M & L anti climbing devices, spikes type fabricated out of M.S. bars (round,square and flat) including nuts,bolts, washers and clamps in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
S & F lightening arrestors HT 11 KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
M & L 4 mm dia GI wire connecting from earth test point to lightening arrestor installed on top of 11 mtr long poles four pole/ two pole structures complete all as directed.
M & L in danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as directed.
Goblin Electric Co.
unique power & control system
SATISH AND CO
M/S BALWINDER SINGH
JCC ENGINEERS PRIVATE LIMITED
TECHNICAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .