| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 546 14 JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹15.0 L+₹1.3 L (9.40%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹16.5 L+₹2.8 L (20.7%)Rejected-AOC | L3 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
27 Jun 2020, 6:00 pmClosed
GE JUTOGH
GE JUTOGH, JUTOGH CANTT SHIMLA (HP)-171008
REPAIR / MAINT OF SOLAR STREET LIGHT, SECURITY LIGHTS WITH CONNECTED ITEMS, HEATING PLANT, COMPRESSOR, DG SET AND OTHER MISC WORK AT JUTOGH, KELVIN GROVE, SANJAULI AND KUFRI UNDER GE JUTOGH
2020_MES_348443_1
GE/JUT-19/2020-21
Open Tender
Civil Works
Item Rate
270 days
JUTOGH SHIMLA
CLASS E CATEGORY b (i)
7 documents required · 7 mandatory
₹500
GE JUTOGH
₹36,000
Yes
9 Jul 2020
30 May 2020
29 Jun 2020
31 May 2020
27 Jun 2020
13 Jun 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose soil and getting out for underground cable/erection of poles, stays , trench etc complete all as specified and as directed.
M & L for sand cushioning for cable with river washed sand and pinning to provide required cover as per SSR Part –I complete all as specified and directed. Note :-Punnd thickness of sand layed shall be measured and paid to contractor.
Supply and laying bricks common burnt clay sub class 'B' bricks old size for cable protection or laid dry on surface/foundation complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
S&F in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed by Engr-in Charge.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing all as directed by Engr-In-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
S&Fin repair of Earth continuity GI wire of 4 mm dia or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as directed by Engr-in-Charge.
S&F in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as directed by Engr-in-Charge.
Supply , Fixing & laying GI tubing light grade 15 mm dia used as water pipe in earthing complete all as directed. Note: All required items and accessories, bend, joints, nut bolts, clamps etc are incl in quoted rates.
Supply, Fixing & laying GI tubing light grade 40 mm dia used as protection pipe for earth lead wire in earthing complete all as directed. Note: All required items and accessories, bend, joints, nut bolts, clamps etc are incl in quoted rates.
Supply, fixing or laying in replacement HDPE (DWC) tubing 50mm dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, road crossing laying on surface etc as reqd at site complete all as specified and as directed. Note: The rate of all accessories such as bend, joints, nut bolts, clamps etc deemed to be incuded in quoted rates.
M&L for Anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered. Note: All items and accessories , bend, joints, nut bolts, clamps etc are measured and paid separately under relevent items.
S&F rigid non-metallic PVC conduit of dia 20 mm including clamping on pole at 3 points using metal strip or clamps for fixing on pole and other accessories for fixing on wall complete all as specified and directed.
Repair and replacement of PVC insulated cable single core with copper conductor 2.5 Sqmm size 1100 volt grade incl lugs and connection complete all as specified and directed.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks, removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways deemed to be included in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes shall be provided by the contractor without any extra cost.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways deemed to be included in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes shall be provided by the contractor without any extra cost.
M&L for surface cleaning of steel tubular poles LT 9 mtr long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates deemed to be included the reapiring of coping with cement / PCC.
S & F in replacement for fabrication of Kiosk box weather proof made out of fibre material complete with TPN aluminium bus of capacity 63 Amps incl one number MCB (SPN) 6 Amp 240 volts fixed on din rail inside the box , clamps of size 20x4mm mounted on PCC/Steel tubular pole complete all as specified and directed.
S&F in replacement of LED street light fittings of 45 watt system wattage and high presure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection of up to 5kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BRTFG 45W LED V2 or equivalent in Havells/Philips/CG/Polycab
S & F in replacement of LED street light fittings of 60-62 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection of up to 5kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specidied and directed. Make : Bajaj Cat Part No BRTFG 60W LED V3 or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of LED street light fittings of 72-75 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection of up to 5kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BRTFG 72W LED V3.
S&F in replacement of LED flood light fittings of 100 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection of up to 5kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BJFL 100W LED I or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of Mushroom shaped decorative LED bollard with IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BLBMC 9W WW LED or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of Cylindrical shaped (FLUTE) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingPCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BGBOL 605 9W LED or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of Tulip shaped LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BGBOM 650 9W LED or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of Rectangular shaped victorian design (TETRIS) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BGBOS 600 9W LED or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of Inverted Pyramid tripod type LED bollard with soft 360 light, IP 65 protection ,resistance to corrosion, better optics for uniform distribution and 10 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Crompton Greaves Cat Part No LBLS1-10-CDL or equivalent in Havells/Philips/CG/Polycab
S&F in replacement of LED post top in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Make : Bajaj Cat Part No BGCT W4 LED WW or equivalent in Havells/Philips/CG/Polycab
S & F in replacement of street light bracket made out of GI pipe note less than 25mm bore suitable to fit with LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 30x4 mm thick including cutting, welding drilling holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
S & F in replacement of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Single phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Beutral loss & Phase reverse incl Power contactors (40 Amps) and incoming - outgoing MCB rating of 25-40 Amps & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC5kW1P-VMS or equivqlent in Schneider/Havells/Legrand Make (i)Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 1 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
S & F in replacement of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Beutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC5kW3P-VMS or equivqlent in Schneider/Havells/Legrand Make (i)Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 1 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
S & F in replacement of switch fuse unit/main switch rewirable type, triple pole & neutral 415 VAC, 50 Hz, 32 Amps alongwith sheet metal enclosure incl connections complete all as specified and directed.
M&L for overhauling , servicing , repairing of gear box of high mast light incl replacemnt of unsv parts and makie full functioning of gear box complete all as specified and directed.
M&L for overhauling , servicing , repairing of 3 phase induction motor 1.1 0 KW , 415 volt , 920 RPM, 50 Hz, single phase of high mast light incl replacemnt of unsv parts and makie full functioning of motorcomplete all as specified and directed.
S&F in replacement of MCB double pole 240 volts, 50Hz , breaking capacity 10KA, B curve 6 to 32 Amps, ISI marked all as specified and as directed.
S&F in replacement of MCB four pole 415 volts, 50Hz , breaking capacity 10KA, B curve 40 Amps, ISI marked complete all as specified and directed.
S&F in replacement of over voltage relay 230 V AC, U>275 V AC, 3 Phase in 1 module suitable for 3 Ph+N suitable for fixing with 4 pole MCB complete all as specified and directed.
Repair and replacement of AC/DC drivers upto 50 watt Watts for LED street light fittings incl taking down old unsv fitting and refixing after replacement of old unsv driver incl complete connections all as directed .
Repair and replacement of AC/DC drivers 60 Watts for LED street light fittings incl taking down old unsv fitting and refixing after replacement of old unsv driver incl complete connections all as directed .
Repair and replacement of AC/DC drivers 70-90 Watts for LED street light fittings incl taking down old unsv fitting and refixing after replacement of old unsv driver incl complete connections all as directed .
M & L for servicing and cleaning of solar street lights incl cleaning of solar panel, cleaning of battrey terminals, putting petroleum jelley on battery terminals, tightening of connections, replacement of unser lugs, marking "GE Jutogh " with synthetic paint on battery , solar panel , LED light and pole with number complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Integrated all in one Solar Street light (Inbuit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 140 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection all as per specified and directed.
S & F in replacement of Semi Integrated two in one Solar Street light (Inbuit Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 40 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection all as per specified and directed.
Servicing of DG Set 125 KVA of any Make ,checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly lube oil hose flexible pipe, hose turbo etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters with cleaning solution such as petrol and diesel and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil grade of required grade up to required level and including checking of control panel, tightening of loose connections and testing to DG Set to the entire satisfaction of the Engineer-in-Charge. Note : (i) Spare parts/Engine oil/check kit/ filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in quoted rates. (ii) Servicing shall be carried out by authorised dealer of manufacturer. (iii) Minimum 6 months gap/200 Hrs of run whichever is earlier shall be considered for next service.
Servicing of DG Set 100 KVA of any Make ,checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly lube oil hose flexible pipe, hose turbo etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters with cleaning solution such as petrol and diesel and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil required grade up to required level and including including checking of AMF control panel, tightening of loose connections and testing to DG Set to the entire satisfaction of the Engineer-in-Charge. Note : (i) Spare parts/Engine oil/check kit/ filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included inquoted rates. (ii) Servicing shall be carried out by authorised dealer of manufacturer. (iii) Minimum 6 months gap/200 Hrs of run whichever is earlier shall be considered for next service.
Servicing of DG Set 63 KVA of any Make ,checking entire system as per manufacturer's catalogue such as checking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly lube oil hose flexible pipe, hose turbo etc and replacing the same with same size, make and capacity of parts, Cleaning all the serviceable filters with cleaning solution such as petrol and diesel and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or any other cleaning solution and refilling new engine oil of required grade up to required level and including including checking of AMF control panel, tightening of loose connections and testing to DG Set to the entire satisfaction of the Engineer-in-Charge. Note : (i) Spare parts/Engine oil/check kit/ filters shall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in quoted rates. (ii) Servicing shall be carried out by authorised dealer of manufacturer. (iii) Minimum 6 months gap/200 Hrs of run whichever is earlier shall be considered for next service. Each service will be measured and paid separately.
Supply only Fan belt set suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed.
Supply only Oil filter with gasket suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed.
Supply only Diesel filter with gasket suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed.
Supply only Element air cleaner(Air filter) inner and outer suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed.
Supply only New dehydrated Engine oil as required grades suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed. NOTE: Engine oil will be suppied in manufacturer sealed barrel.
Taking down of radiator from DG set (63 kVA to 125 kVA) of any type any make carefully cleaning of tubes and fins complete with the help of proper cleaning agent and wire brush soldering of tubes and fins at required places testing and refilling complete all as specified and directed.
Taking down of defective water pump from DG set (63 kVA to 125 kVA) of any type any make repair the same by water pump repair kit removing of leakage refitting after testing complete all as specified and directed.
Repair and Replacement of water pump body assembly suitable for 63 kVA to 125 kVA DG Set of any type any make complete all as specified and directed.
Repair and replacement of self starter motor and charging alternator 24 volts complete set incl dismantling and taking down old unser from DG set suitable for 63 kVA to 125 kVA DG set of any make any type complete all as specified and directed.
Repair and replacement of self starter motor and charging alternator 12 volts complete set incl dismantling and taking down old unser from DG set suitable for 63 kVA to 125 kVA DG set of any make any type complete all as specified and directed.
Cleaning of fuel tank of different capacity DG sets by taking down from system cleaning internally by using proper cleaning agent welding to leakage portion complete all as specified and directed.
Repair and replacement of maintenance free dry type DC battery 12V 150ah, complete all as specified and directed.
S&F in replacement HRC fuse Din type of capacity 250 Amps breaking capacity >80 kA , 500 volt AC 50 Hz complete all as specified and directed.
Comprehensive maint of Air compressor and carry out the repair and servicing incl replacement of minor sapres parts required for repair, nut, bolts, gasket, lubrication complete all as specifeid. Note: (i) The rate for the minor spare parts required for repair is deemed to be included in quoted rates.
S & F in replacement Air filling pipe with nozzle (12 Mtr) complete all as specified and directed.
Comprehensive maint of single phase Car washing pump and carry out the repair and servicing with replacement of the following spares and refixing the same in original position and testing as per satisfaction of Engr-in-Charge. Note: (i) The rates for minor parts required for repair other than the parts consider under relevant items to be included in quoted rates. (ii) Spares required for replacement shall be measured and paid under relevant items as supply only.
Supply only Gasket as per sample/existing all as directed.
Supply only PVC hose pipe flaxible as per sample with adjustable water nozzle.
Comprehensive maint of heating plant and carry out the repair and servicing with replacement of the following spares and refixing the same in original position and testing as per satisfaction of Engr-in-Charge. Note: (i) The rates for minor parts required for repair other than the parts consider under relevant items to be included in quoted rates. (ii) Spares required for replacement shall be measured and paid under relevant items as supply only.
Supply only Strip heater 3 kW as per sample/existing all as directed.
Taking down blower motor of capacity 3.7 kW 3-phase from heating plat and repair with replacement of unsv parts and refixing at original position with testing to the entire satisfaction of Engineer-in-charge
Disconnecting / taking down / dismantling Solar flat plate collector of 100 LPD capacity for servcing , cleaning and repairing, brazing of tubes complete and reassembling the same after repairto the entire satisfaction of Engineer-in-charge
M & L for De-scaling, cleaning of hot water tanks incl heat collecting units with heat absorbing sheet etc of solar heating system of capacity 1500 LPD complete to the entire satisfaction of Engineer-in-charge
M & L for De-scaling, cleaning of hot water tanks incl heat collecting units with heat absorbing sheet etc of solar heating system of capacity 500/750 LPD complete to the entire satisfaction of Engineer-in-charge
S&F in replacement electric heating element 3 kW capacity 240 volt incl connection complete all as specified and directed.
Repair and replacement of rubber gasket of heat collecting units of solar heating system of any capacity complete all as specified and directed.
S & F in replacement water storage tank of 1000 Ltr capacity rotational moulded polyethylene water storage tank, 3 layered (Cylindrical / vertical with closed top), hoisted and fixed in position, connected to existing water system incl provision of float valve complete all as specified and directed.
S & F in replacement Ball brass valves 20 mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed with existing water connections complete all as specified and directed.
Repair and replacement of solar flat plate collector of capacity 100 LPD with solar absorber material , gasket, nut bolts, washers and insulation and other connected accessories incl taking down old unsv and fixing new with existing connection by making proper connection and ensure proper functioning complete all as specified and directed.
S&F in replacement of PVC insulated flexible unarmoured cable three core with copper conductor 2.5 Sqmm size 1100 volt grade incl lugs and connection complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .