| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.1 LAccepted-AOC THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L1 | Accepted-AOC BEING LOWEST TENDER, L1 | |
| 2 | L2₹99.2 L+₹7.8 L (8.55%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L2 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 3 | L3₹99.9 L+₹8.5 L (9.34%)Rejected-Finance 3 165 1A KAMARAJ NAGAR KANGAYAMPALAYAM SULUR COIMBATORE TAMIL NADU 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 4 | L4₹1.0 Cr+₹8.7 L (9.54%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 5 | L5₹1.1 Cr+₹15.7 L (17.2%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER. |
| Sl No | Description | Qty | Unit | KUMAR AGENCIES L1 | Neptune Engineers and Builders L9 | KRISHNA ENTERPRISES L6 | SUPER COOL L7 | Lucky Enterprises L11 | A.GOVINDARAJ L4 | KSR AND COMPANY L2 | K S MUTHU CONSTRUCTTIONS L5 | Vishnu Infrastructures L3 | NLK Construction L8 | T C KARUNANITHI L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||||||
| 2.00Note for all items of this BOQ :- | ||||||||||||||
| 3.00SITE FOR EXECUTION OF WORK :- Tenderer shall note that entire work shall be executed at Runway / taxi track/ Tarmac & around of airfield area. | ||||||||||||||
| 4.00Due to continuous Flying commitment at Sulur Station, site for execution of work will be available only on Saturday, Sunday, Holiday and non flying days as decided by the ATS authorities. | ||||||||||||||
| 5.00The tenderer has to arrange his working programme accordingly. | ||||||||||||||
| 6.00The tenderer has to liaise with the ATS authorities two days prior of his planned works and schedule accordingly. | ||||||||||||||
| 7.00No claim on account of not giving the entire site after award of work or giving the site in piecemeal manner will not be entertained by the department at any stage. | ||||||||||||||
| 8.00The tenderer shall adhere to time frame as per the user’s requirement and as per demand. The demand and the location of work will be intimated either by the rep of user/ MES rep well in advance. In case of failure to attend the demand in time penalty will be levied for each day @ Rs 500/ for non-completing the requirement till completion of work. The nature of the work related to Airfield maintenance, hence the delay is not acceptable. | ||||||||||||||
| 9.00The unit rate deemed to be considered for First Aid and necessary safety arrangements equipment’s to be provided by the tenderer for workman. | ||||||||||||||
| 10.00The quoted rates shall be deemed to be inclusive of above mentioned aspects. | ||||||||||||||
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
21 Aug 2025, 6:00 pmClosed
GE AF SULUR
KANGAYAMPALAYAM
REPAIR / MAINT TO FLEXIBLE PAVEMENT IN MRW, CRACKS FILLING, JOINT FILLING, RUNWAY PAINTING AND RUNWAY / ORP AREA, MONSOON DRAIN/ SAUCER DRAIN/ NALLAH/ CULVERT, FOD TRAP, LEVELLING / GRADING OF SHOULDERS, MOORUM FILLING, GRASS CUTTING AND CERTAIN MISC
2025_MES_720334_1
8775/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
GE AF SULUR
Please refer to tender document
7 documents required · 7 mandatory
₹1,000
GE AF SULUR
₹1.7 L
14 Oct 2025
24 Jul 2025
23 Aug 2025
24 Jul 2025
21 Aug 2025
14 Aug 2025
27 Jul 2025 - 10 Aug 2025
Amount
SCHEDULE A BOQ
Note for all items of this BOQ :-
SITE FOR EXECUTION OF WORK :- Tenderer shall note that entire work shall be executed at Runway / taxi track/ Tarmac & around of airfield area.
Due to continuous Flying commitment at Sulur Station, site for execution of work will be available only on Saturday, Sunday, Holiday and non flying days as decided by the ATS authorities.
The tenderer has to arrange his working programme accordingly.
The tenderer has to liaise with the ATS authorities two days prior of his planned works and schedule accordingly.
No claim on account of not giving the entire site after award of work or giving the site in piecemeal manner will not be entertained by the department at any stage.
The tenderer shall adhere to time frame as per the user’s requirement and as per demand. The demand and the location of work will be intimated either by the rep of user/ MES rep well in advance. In case of failure to attend the demand in time penalty will be levied for each day @ Rs 500/ for non-completing the requirement till completion of work. The nature of the work related to Airfield maintenance, hence the delay is not acceptable.
The unit rate deemed to be considered for First Aid and necessary safety arrangements equipment’s to be provided by the tenderer for workman.
The quoted rates shall be deemed to be inclusive of above mentioned aspects.
Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and M&L rendering 15 mm thick on brick or concrete surfaces, in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and as directed. (Water proofing compound shall be measured and paid seperately)
Supply only water proofing compound
M&L for Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth complete all as specified and as directed
M&L for preparing old surface with Mechanical wall sander and applying two coats of water based premium acrylic smooth exterior quality emulsion paint on old wall surfaces of approved colour in two coats @ 0.75 ltr (undiluted)/ 10 sqm (for each coat) diluted with water as per manufacturer instructions applied over preparing surfaces with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. etc complete all as specified and directed. Note: (i) Any two approved colour in checkered pattern should be painted on wall surface. The quoted rate includes the same. (ii) The Exterior emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified. (iii) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. (iv) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L repairs to cracks of any description, less than 5mm size by opening up cracks in V-groove manner approximately 6mm x 6mm size using mechanical cutter, cleaning the groove properly to remove loose particles, dust etc, sprinkling with clean water and filling with single component entitious crack filler using readymix powder of cementitious ingredients having compressive strength of 14 N/ mm² after 7 days complete all as specified and as directed. Make M/s STP Limited/ M/s Sika India Pvt Ltd/ M/s Fosroc Chemicals/ M/s Thermex
M&L repairs to runway cracks by using 'RUNPHALT' bitumen tubing/ rope for filling of cracks on the runway width of crack 5mm to 7mm with the help of screw driver pushing it inside the crack then apply direct flame 20-30 second through torch method complete all as per manufacturers instruction and as directed by Engineer-in-Charge. Make:- M/s Srijan System Pvt Ltd or equivalent as approved by GE
M&L for preparing old surface with Mechanical wall sander and applying One coat of water based premium acrylic smooth exterior quality emulsion paint on old wall surfaces of approved colour in one coat @ 0.75 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over preparing surfaces with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. etc complete all as specified and directed. Note: (i) Any two approved colour in checkered pattern should be painted on wall surface. The quoted rate includes the same. (ii) The Exterior emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified. (iii) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. (iv) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M & L for grass/vegetation cutting, removal of bushes, leaves, soil or any other waste material debris along the Runway edges and surrounding area of Air Field of any size in width and depth and removing the debris to a distance exceeding 5 Km outside MD land periphery of the airfield all as directed.
Note for item No 18 : The tenderer shall take into consideration for following points while quoting rate for the above item : a) Grass cutting shall be used by mechanical earth moving machineries with jungle jim attachment as and when required and as directed (b) One Skilled jungle jim tractor operator & 01 Tractor with Jungle Jim attachment to be provided by the contractor as and when required (c) POL for jungle jim tractor to be borne by the contractor (d) For 1 Day Min 8 hrs to be operated
M&L repairs to runway cracks by using 'RUNPHALT' bitumen tubing/ rope for filling of cracks on the runway width of crack 8mm to 10mm with the help of screw driver pushing it inside the crack then apply direct flame 20-30 second through torch method complete all as per manufacturers instruction and as directed by Engineer-in-Charge Make:- M/s Srijan System Pvt Ltd or equivalent as approved by GE
M&L Runway edge shoulder dressing by picking stones/ any foreign materials, cleaning/cutting the grass on runway shoulder edges manually or with hand operated petrol/kerosene driven grass cutting machine and removing the materials/ grass waste from Runway edges to a distance exc 250m Note: Contractor shall provide 02 Nos of skilled manpower to execute the job alongwith necessary grass cutting equipments / machineries etc on a required basis as directed by Engineer in charge.
M&L cutting, removing damage portion of concrete surface in square/ rectangular shape for depth of 20 to 30mm thick, cleaning the surface with wire brush or cloth and removing the dirt including the wetness and dampness by means of dryer and supply and laying geo polymer based "Geo Krete - of Make eco materials or equivalent in Fosroc chemicals/ Tiki Tar/ M/s STP Limited/sika india pvt ltd rapid setting curing free semi levelling structural mortar of single compound activated by water for quick construction & levelled the surface to match with existing surface and making good the disturbed portion around the area where material are applied all as per manufacturer’s instructions as specified & directed. The geopolymer based water impermeable concrete resurfacing mortar shall have compressive strength of 15 M Pa in 2 hours and 50 M Pa in 28 days without any water curing and curing compounds having a water penetration of less than 2mm when tested as per DIN 1048 and RCPT valve of less than 800 coloumbs when tested as per ASTM C 1202.
M&L for Chipping out neatly and cutting of existing loose concrete of cracks at rigid pavement in Air Field area by using saw cutter, Cutting of crack portion shall not be less than 100 mm wide and 25 mm deep (minimum) and clearing of all loose material with air blower/ sand blaster and the portion applying proprietory primer on surface to obtain tack and finally filled by Elastomeric concrete mix shall be prepared as per manufacturer's instructions to obtain true surface and finally set the surface with hand tools complete all as specified and directed. Make:-M /s Fosroc Chemicals - Patchroc Chemicals / M/s STP Limited- ShaliPatch / M/s Choksey Chemicals Pvt Ltd. -Flex 0 patch. Note: Providing masking tape at joints/ on edge of cut portion and necessary formwork required if any at spalled joints edge to prevent accidental spillage of concrete on top surfaces to give a neat finish and any spillage on concrete slab to be cleared. The quoted rate is deemed to be inclusive of this provision.
S & F SS Sign board pattern (SS to SS-7), fully retro reflective sign board made of 3mm thick ACP (Aluminum composit panel) sheet framed with 40mm round SS pipe having front/back (both) side entire surface fully bonded with retro reflective sheeting of HIP (High Intensive Prismatic) grade having pressure sensitive adhisive. boarders and message as indicated cut out. Back ground in Blue and matter in white colour tape having two posts of 50mm round SS pipe 3.0mtr long including excavating post holes of 30 x 30 x 30 cm and embedded in PCC 1:3:6 and including taking down and removing rubbish material to outside MD land complete and as directed by Engineer-in-charge
M&L Filling the pot holes in concrete surfaces of size n exc 15mm in dia and 20mm in deep by using a mixture of quartz sand No 9 -450 parts by weight, Hardner Hy 140-50 parts by weight and araldite GY 257-100 parts by weight to form a hard paste and filling the pot holes after cleaning the dust particles with blower and applying primer coat with epoxy resin of mix with formulation of 100 parts of araldite GYZ 57 and 50 parts of hardner Hy 840 by weight and ramming with hammer to make a uniform surface to match with the existing concrete surfaces all as specified and as directed. Note: Contractor shall provide 02 Nos of skilled manpower to execute the job on a required basis as directed by Engineer in charge.
M&L for applying two coats of water based road marking paint such as lines, dashes, arrows, letters, boxes etc on flexible/rigid pavements and the like including complete removal of existing painting surfaces by brushes/ mechanical grinder/ sand papers, making surface rough to hold paint exceeding 10 cm wide all as specified and as directed using mechanical pavement marking machine including necessary DG Set required to operate the machine. Complete scraping / removal of existing paint deemed to be inclusive in the above quoted rate.
M&L for DTGM board black colour 3mm/4mm thick acrylic sheets of size 1.50 x 1.20 m approx and fixing of retro reflective stickers (red colour) on acrylic sheets, fixing the boards to PVC pipe etc including taking down existing broken acrylic board complete all as specified and as directed.
M&L Retro Reflective tape/orientation stickers in any pattern, shape/ number/ letters on old existing boards after cleaning including removing of existing letters/tape complete all as specified and directed.
M&L for Info sign boards 3mm/4mm thick acrylic sheets of any size and fixing of retro reflective stickers (red or any approved colour) on acrylic sheets, fixing the boards to PVC pipe or any other surface etc including taking down existing broken info sign boards complete all as specified and as directed.
M&L DTGM board black colour 4mm thick acrylic sheets 02 Nos each of size 1.50 x 1.20 m with 100 mm dia air pressure clearance circle 8 Nos on each board including acrylic polishing, fixing of retro reflective stickers (red colour) of length 1.00 m and width 0.15m on each board, fixing the boards to 3 nos of 63mm dia PVC pipe heavy duty (Class 5 -IS 4985) 10Kgf/Cm2 as vertical post of approx height 2.48 m each pipe covered at top with PVC caps on each pipes and inter connecting the vertical PVC pipes at top,middle, bottom portion with 25mm dia PVC pipes 15 Kgf/cm2 (IS 4985) fixed with PVC bushes and screws, erecting the frames in GI/MS pipes etc including taking down existing one complete and all as directed by Engineer in charge.
M&L for removing the existing damaged filled sealing compound including polyethylene rod by raking end using blow lamp and cleaning of expansion/construction/dummy joints of concrete pavement free from dust and applying masking tape on edge of joints to prevent accidental spillage of sealant on top slab surfaces to give a neat finish, provision of polyethethylene backup rod 10-15mm dia in any type of joint and sealed with 10-12 mm thick polyurethane based sealing compund confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer and removing the masking tape after the sealant filling etc complete all as specified and as per manufacturers instructions. The size of the joint is 8 to 12 mm wide for any type of joint.
M&L for removing the existing damaged filled sealing compound including polyethylene rod by raking end using blow lamp and cleaning of expansion/construction/dummy joints of concrete pavement free from dust and applying masking tape on edge of joints to prevent accidental spillage of sealant on top slab surfaces to give a neat finish, provision of polyethethylene backup rod 15-25mm dia in any type of joint and sealed with 10-12 mm thick polyurethane based sealing compund confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer and removing the masking tape after the sealant filling etc complete all as specified and as per manufacturers instructions. The size of the joint is 12 to 20 mm wide for any type of joint.
M&L for removing the existing damaged filled sealing compound including polyethylene rod by raking end using blow lamp and cleaning of expansion/construction/dummy joints of concrete pavement free from dust and applying masking tape on edge of joints to prevent accidental spillage of sealant on top slab surfaces to give a neat finish, provision of polyethethylene backup rod above 25mm dia in any type of joint and sealed with 10-12 mm thick polyurethane based sealing compund confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer and removing the masking tape after the sealant filling etc complete all as specified and as per manufacturers instructions. The size of the joint is above 20 to 45 mm wide for any type of joint.
Note for item no 30 to 32 above: (a) The existing sealant compound shall be taken out completely using blow lamp and joint shall be cleaned with wire brush and loose particles dust etc shall be removed by using hand pump before applying primer. (b) Any spillage of material during filling over the slab shall be removed and cleaned by contractor and any damage accrued to the concrete slab will be made good by the contractor without any extra cost to the department. (c) Make M/s STP Ltd, M/s Pidilite Industries Ltd, M/s Sika India Pvt Ltd, M/s Fosroc chemicals India Pvt Ltd, M/s Choksey chemicals Pvt Ltd
M&L for applying one coat of water based road marking paint such as lines, dashes, arrows, letters, boxes etc on flexible/rigid pavements and the like including complete removal of existing painting surfaces by brushes/ mechanical grinder/ sand papers, making surface rough to hold paint exceeding 10 cm wide all as specified and as directed using mechanical pavement marking machine including necessary DG Set required to operate the machine. Complete scraping / removal of existing paint deemed to be inclusive in the above quoted rate.
M&L for applying one coat of water based paint of yellow/orange/red/grey colour on runway/taxiway/apron or other airfield markings of any size and length including letters and numeral markings with suitable spray machine, including complete removal of existing painting surfaces by brushes/ mechanical grinder/ sand papers, making surface rough to hold paint exceeding 10 cm wide all as specified and as directed. Complete scraping / removal of existing paint deemed to be inclusive in the above quoted rate.
M&L for applying one coat of water based paint of black colour on runway/ taxiway/ apron or other airfield markings of any size and length including letters and numeral markings with suitable spray machine, including complete removal of existing painting surfaces by brushes/ mechanical grinder/ sand papers, making surface rough to hold paint not exceeding 10 cm wide all as specified and as directed. Complete scraping / removal of existing paint deemed to be inclusive in the above quoted rate.
M&L for applying one coat of white wash on walls /concrete pavement surface including preparation of old surfaces complete all as specified and as directed.
M&L repairs to airfield cracks using Single component 'Aspha-Flo' coal tar free signature grade Gilsonite modified Asphalt emulsion, special polymers and additives streaming crack, joint stuffer to prevent cracks from forming into pot holes and filling of cracks and joints on asphaltic surface of the runway and capable to be applied directly on damp pavement also all as per manufacturer's instructions as specified and directed.
Note for item No 37 The coverage for different size of cracks shall be as given below:- (i) 24.20 meter/Ltr for 6mm (width) x 6mm (Depth) crack (ii) 6.05 meter/ L for 13mm x 13mm crack (iii) 2.10 meter/ L for 25mm x 25mm crack . (iv) Back-up rod to be used in case depth is more than 25mm.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., including removing debris material to out side MD land complete all as specified and directed.
M&L Brickwork with fly ash bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width type C-1 1:3:6 using 20mm graded stone aggregate and setting in mortar 1:6 straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed
M & L Rendering 10 mm thick on brick or concrete surfaces, in cement mortar 1:4 as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed.
M&L taking down the cover slab/ welded wire mesh/ steel channels etc of existing covered Rain water pit of size 6 meter dia, cleaning up to depth 7.0 meter removing mud/silt, vegetation growth, plants/small trees etc to ouside MD land, and refix the cover slab after cleaning of pit including repairing of cracks in cement mortar (1:3) where noticed in surface and making good complete all as specified and as directed. Note: The unit rate is deemed to be included for removing of the mud/silt obtained from the rain water pit and accumulated earth of any width and depth, cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 1m from the outer wall of the rain water pit to outside MD land. The periodicity of cutting of grass shall be before commencement of work and after completion of repairs
M & L Preparation of old painted surfaces of steel/iron surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of red oxide/zinc chrome primer and one coat of synthetic enamel (ordinary tint) paint complete all as specified and as directed
M & L Preparation of new or untreated surfaces of steel/iron surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of red oxide/zinc chrome primer and two coat of synthetic enamel (ordinary tint) paint complete all as specified and as directed
M&L for Carefully lifting/taking out the suspended RCC drain cover slab laid over drain near Air Field of any size upto 1.5 Sqm in plan area without damaging and placing in the orginal position after completion of repair / de-siltting work complete all as specified and as directed at site. Note:- The work area is inside Airfield where the flying operations frequently held. Hence, repair works is to be done as and when site is available with prior permission from air force authority. Proper placing of the RCC cover slabs shall be done at end of the working day. RCC cover slabs must not left and uncovered near the drainage and shall be removed under the supervision/ instructions of site executives only. Relaying cover slabs can be done as per the demand/need of the user unit depending upon the flying operations.
M&L for Levelling of runway shoulders with grader mechanical machine and rolling of surface with road roller of capacity 8-10 tonne, including removal of boulders and other materials obtained from the airfield area complete all as specified and as directed.
Surface dressing not exc 15 cm deep in soft/loose soil complete all as specified and as directed.
M & L moorum/red bajri filling including spreading and levelling in layers not exceeding 15 cm thick, spread, levelled and rammed Including watering and rolled to true surfaces with 8 to 12 Ton capacity power roller to achieve compaction of 98% modified proctor density complete all as specified.
Note for Item No 48 above :- (i) Moorum/red bajri required shall be brought from outside MD land. (ii) Compaction of moorum filling shall be carried out under optimum moisture conditions up to the standard proctor density not less than 98 percent. (iii) Measurements shall be taken after consolidation earth and 5% deduction shall be made for payments.
M&L for PVC pipes of any dia fixed to DTGM boards including disconnecting and taking out old unserviceable pipes from the boards complete all as specified and as directed
S&F High strength corrosion resistant TMT bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified.
M & L Precast Reinforced cement concrete 1:2:4 type B1, using 20 mm graded granite stone aggregate in landings, cover slabs (for manhole etc) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15cm thick below or above ground level complete all as specified and asdirected.
M&L Excavation and removal of deposited spoil/silt and any type soil in foul position from the existing storm water drainages/ rain water pits of size exc 1.50 m wide and depth not exc 4.50m by getting out including removal of sludge /silt/soil outside MD land to a distance exc 1.50 Km but n. exc 5.00 Km and depositing where directed.
Cleaning of existing cover drain of any depth any width by using jet water pressure mechanical pump,suction pump and removing mud/silt, vegetation growth, plants/small tress etc to a distance 50m, including repairing cracks in cement mortar (1:3) where noticed in surface of drain all as directed and specified.
Note for item No 54: The unit rate is deemed to be included for removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 1m from both side of the drain to outside MD land
M&L in repairs of mooring rings making circular hole of dia 200 mm and depth 50 mm in to M40 concrete, cut to shape using concrete by DCH 300 of HILTI DD 200 machine (water cooled), making holes 2 Nos of dia 24 mm and depth 200 mm using TE 70 combi hammer, grouting the holes with HILTI HY 150 injection chemical for 2 holes (Approx 100 ml per hole) & fixing of inverted U shaped 20 mm dia round bars (Mooring Ring) with a minimum of 200 mm anchorage in to concrete and filling up the circular portion of 200 mm dia after grouting the re-bar using solid grout with high flow non-shrink cementious grout "conbextra" after applying a bonding coat using 'Nito Bond EP' as per manufacturer's instructions including 80 mm outer dia ring made out of 16 mm MS round bar fixed into U shaped 20 mm dia bars and painted with two coats of synthetic enamel paint over a coat of zinc chrome primer to exposed surfaces of round bars etc complete all as specified and as directed
M & L removing leaves, grass, bushes, soil, plastic bags or any other waste material debries from drain and surrounding area of Air Field of any size in width and depth and removing the debris to a distance exceeding 5 Km outside MD land periphery of the airfield including removing and refixing cover slab after carried necessary repair work in CM 1:3 complete all as specified and as directed
Dismantling wrought iron or mild steel work of FOD TRAP / Grating of any description not other wise provided for and refixing after getting in good position by tighting/ welding complete all as specified and as directed
Note for item No 57: Additional required mild steel shall be measured and paid separately as supply only. However, labour element for fabrication, erection, fixing and welding, with ends of bars shouldered and/ or riveted is deemed to be included in this item complete all as specified and as directed
Supply only framed work such as gratings, angles or tees, beam, channel with web and flanges etc for FOD TRAP complete all as specified and as directed
M & L PCC 1:1½:3 type A-1 (using 20 mm graded stone aggregate) as in foundation, filling, posts, bed blocks and similar works including dismantling and form work complete all as specified and as directed
M&L for Cleaning of existing open drain of any width and depth by using jet water pressure mechanical pump, suction pump and removing mud/ silt, vegetation growth, plants/small trees etc to a distance outside MD land, including repairing cracks in cement mortar (1:3) where noticed in surface of drain complete all as specified and as directed.
M & L Providing 75mm thick plain cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base to tiles complete all as specified and as directed.
M&L 100mm thick, plain cement concrete (1:1(1/2):3), type A-1 (using 20 mm graded mechanically crushed stone aggregates), as in hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M & L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including demolition of existing undulated hardcore surface and removing the same complete all as specified and as directed.
M&L for Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed.
M&L for removal of demolished material outside MoD land complete all as specified and as directed.
M&L for applying one coat of water based paint of black colour on runway/ taxiway/ apron or other airfield markings of any size and length including letters and numeral markings with suitable spray machine, including complete removal of existing painting surfaces by brushes/ mechanical grinder/ sand papers, making surface rough to hold paint exceeding 10 cm wide all as specified and as directed. Complete scraping / removal of existing paint deemed to be inclusive in the above quoted rate.
KSR AND COMPANY (BID ID -3400504)
Vishnu Infrastructures (BID ID -3401094)
A.GOVINDARAJ (BID ID -3399621)
K S MUTHU CONSTRUCTTIONS (BID ID -3401050)
KRISHNA ENTERPRISES (BID ID -3398813)
SUPER COOL (BID ID -3398941)
NLK Construction (BID ID -3401911)
Neptune Engineers and Builders (BID ID -3398345)
T C KARUNANITHI (BID ID -3401234)
Lucky Enterprises (BID ID -3399508)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .