Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 CrAdmitted-Finance | ₹9.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.6 Cr+₹1.7 Cr (16.9%)Admitted-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹11.6 Cr+₹1.7 Cr (16.9%) | L2 | Admitted-Finance |
| 3 | L3₹12.6 Cr+₹2.7 Cr (27.3%)Admitted-Finance 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹12.6 Cr+₹2.7 Cr (27.3%) | L3 | Admitted-Finance |
| 4 | L4₹13.6 Cr+₹3.7 Cr (36.9%)Admitted-Finance 1ST FLOOR SPARTAN HOUSE PLOT NO B29 ROAD NO 18S WAGLE ESTATE THANE W THANE MAHARASHTRA 400604 INDIA | THANE | MAHARASHTRA | 400604 | ₹13.6 Cr+₹3.7 Cr (36.9%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | PRANAM HVAC ENGINEERING PVT LTD L3 | Purvi Engineers India Pvt Ltd L1 | EVERCREST PROJECTS PVT LTD. L2 | BATLIBOI ENVIRONMENTAL ENGINEERING LIMITED L4 |
|---|---|---|---|---|---|---|---|
| 1.00Note: This Document shall be read in co-ordination with detail specifications Design, Supply Installation Testing & Commissioning of the following: Exhaust air Fans : SISW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. MS construction shall be epoxy painted. Static Pressure: 350 mm WC Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule ) | |||||||
| 1.1031050 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS) | |||||||
| 1.11 | SUPPLY | 2 | Nos | 31,71,320 ₹63,42,640 | 27,50,000 ₹55,00,000 | 26,86,429 ₹53,72,858 Lowest | 32,50,000 ₹65,00,000 |
| 1.12 | ERECTION | 2 | Nos | 1,00,000 ₹2,00,000 | 2,07,500 ₹4,15,000 | 24,061 ₹48,122 Lowest | 50,000 ₹1,00,000 |
| 1.20103000 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS) | |||||||
| 1.21 | SUPPLY | 2 | Nos | 72,15,000 ₹1,44,30,000 | 76,00,000 ₹1,52,00,000 | 72,78,391 ₹1,45,56,782 | 56,50,000 ₹1,13,00,000 Lowest |
| 1.22 | ERECTION | 2 | Nos | 1,50,000 ₹3,00,000 | 2,07,500 ₹4,15,000 | 40,101 ₹80,202 Lowest | 1,00,000 ₹2,00,000 |
| 1.30110000 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS) | |||||||
| 1.31 | SUPPLY | 2 | Nos | 72,15,000 ₹1,44,30,000 | 76,00,000 ₹1,52,00,000 | 77,90,228 ₹1,55,80,456 | 57,00,000 ₹1,14,00,000 Lowest |
| 1.32 | ERECTION | 2 | Nos | 1,50,000 ₹3,00,000 | 2,07,500 ₹4,15,000 | 40,101 ₹80,202 Lowest | 1,00,000 ₹2,00,000 |
Tender Value
₹14.3 Cr
Closing Date
3 Dec 2021, 2:00 pmClosed
DEC (CED, EP, PD MS and MPS)
2nd Floor Sarathi building, Nuclear Fuel Complex, ECIL Post, Hyderabad
Supply, Installation, Testing and Commissioning of Secondary Exhaust Air System at Wet Area, NFC Kota
2021_NFC_652854_1
E/625/2021
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
270 days
NFC-Kota, Rawatbhata Rajasthan
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
31 Jan 2022
13 Oct 2021
4 Dec 2021
13 Oct 2021
3 Dec 2021
10 Nov 2021
14 Oct 2021 - 30 Oct 2021
Amount
Note: This Document shall be read in co-ordination with detail specifications Design, Supply Installation Testing & Commissioning of the following: Exhaust air Fans : SISW type, backward curved, belt driven. Temperature to be considered is 50deg C. The scope also includes accessories like flexible connections at fan outlet,common base frame, vibration isolators, V-belt, guard, electrical actuator controlled volume control damper at the outlet. MS construction shall be epoxy painted. Static Pressure: 350 mm WC Drive Arrangement Suitable with VFD (Note: VFD is covered in electrical schedule )
31050 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS)
SUPPLY
ERECTION
103000 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS)
SUPPLY
ERECTION
110000 CFM (MOC:Air Stream Components i.e. Casing and Impeller to be made of SS304 and the rest of the fan will be MS)
SUPPLY
ERECTION
SS304 Ducting: Supply/Exhaust air duct with SS304 material complying to ASTM A 240. Accessories included: supply/exhaust air collars, vanes, splitters, necessary MS structural members (viz. angle flanges for duct joining, lateral& longitudinal reinforcement, internal tie rods, fasteners), gaskets, sealent, etc. Duct construction shall be as per IS-655/SMACNA standrad. (Note: Necessary duct supporting structural material (MS) is covered under item)
18 Gauge, Rectangular
SUPPLY
ERECTION
22 Gauge, Rectangular
SUPPLY
ERECTION
18 Gauge, Circular
SUPPLY
ERECTION
22 Gauge, Circular
SUPPLY
ERECTION
16 Gauge for plenum
SUPPLY
ERECTION
Manually operated Volume Control Dampers Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
Circular, MOC: SS304
SUPPLY
ERECTION
Circular, MOC: SS304
SUPPLY
ERECTION
Electrically operated Volume Control Dampers for ducting with one of the dimensions 1.0 mtr and above Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
Rectangular , MOC: SS304
SUPPLY
ERECTION
Circular, MOC: SS304
SUPPLY
ERECTION
Actuators for electrically operated Volume Control Dampers
SUPPLY
ERECTION
Non Return damper MOC: SS 304 Thickness: 16 G Thick Dimensions: As per Requirement Measurement: Cross Sectional Flow Area including flanges
SUPPLY
ERECTION
Fusible link type Fire dampers MOC: GI Thickness: 16 G Thick Dimensions: As per Requirement Note: Dampers shall be CBRI tested & certified for minimum 90 minutes rating as per UL 555 Measurement: Cross Sectional Flow Area including flanges
SUPPLY
ERECTION
Supply Air Grills: Type : Double deflection grills/Four Way Diffusers as per layout MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G Accessories : Volume control Dampers
SUPPLY
ERECTION
Return Air diffusers MOC: Extruded Aluminium Powder Coated Frame Thickness : 16 G
SUPPLY
ERECTION
MS. Structure (For General purpose): Painting : Epoxy painting with primer Scope: Duct supports, Yard Trustels for carrying ducts, supporting stand.
SUPPLY
ERECTION
MS. Structure(For retainer frames): Painting : Epoxy painting with primer Scope: HEPA filter/ Pre Filter/ Fresh Air filter/Air Distributer/ Mist Eliminator etc
SUPPLY
ERECTION
HEPA Filters Grade : H-14 Size: 610x 610x300 mm (Approx.) Flow Rate: 2000 CFM Efficiency : 99.97% down to 0.3 micron Initial Pressure Drop: 40 mmWC maximum in clean condition Casing : 1.2 mm thick Aluminium Media : Borosilicate Microfibre
SUPPLY
ERECTION
Pre-Filters Grade : G4 Size: 610x 610 mm Flow Rate: 2000 CFM Efficiency : 95% down to 10 micron Initial Pressure Drop: 12 mmWC maximum in clean condition Casing : 1.2 mm thick Aluminium Media : Non woven Synthetic media sandwiched between 2 layers of HDPE Mesh
SUPPLY
ERECTION
MS Leak tight doors Size : 2.215 x1.115 m Note: For masonary type HEPA/Pre-filter chambers Refer : Drawing no C-CED/EP(AC&V)-142
SUPPLY
ERECTION
1)Developing CAD drgs pertaining to GA, duct layout drawings as per specifications. 2)Simulation of Air flow pattern by CFD analysis using ANSYS or equivalent software. 3) Developing P&ID drgs of all ventilation systems as per schemes given 4) Assessing TAG numbers to all ventilation equipment 5)Validating of total sytem by smoke test.
SUPPLY
ERECTION
Design, Engineering, fabrication, transportation, supply, Safe handling, site storage, Installation, Testing & Commissioning of Motor Control Centre for air blowers and pumps as per tender specifications
Wet Section ventilation PDP 4P, 800A EDO type ACB I/C-2Nos. 4P, 800A EDO type ACB B/C-1No. 3P+NL, 400A MCCBs --- 2 Nos. 3P+NL, 250A MCCBs --- 3 Nos. 3P+NL, 63A MCCBs --- 3 Nos.
SUPPLY
ERECTION
Damper Control Panel 4P, 63 A MCCB I/C-1Nos. 1 KW DOL starter(3Phase) - 8 Nos 1 KW DOL starter(1 Phase) - 9 Nos 3P+NL, 32A MCCB --- 1 Nos.
SUPPLY
ERECTION
Design, Engineering, fabrication, transportation, Safe handling, site storage, Installation, Testing & Commissioning of Variable Frequency Drives for air blowers and pumps as per tender specifications
280kW VFD panel
SUPPLY
ERECTION
90kW VFD panel
SUPPLY
ERECTION
Supply, installation, testing and commissioning of 1100 V grade, XLPE insulated and armoured FRLS cables of following sizes as per data sheet, specifications of this tender and directions of Engineer-in-Charge. including transport, all labour and materials, complete in all respects.
3.5Cx 185 sqmm Al conductor
SUPPLY
ERECTION
3Cx185sqmm copper conductor
SUPPLY
ERECTION
3Cx 70 sqmm copper conductor
SUPPLY
ERECTION
4Cx2.5sqmm copper conductor
SUPPLY
ERECTION
Termination of XLPE insulated armoured Aluminium/Copper power cables (up to 1100 V grade) and connection of leads including the supply of single compression cable glands and heavy duty copper lugs, drilling of suitable holes in equipments for fixing purposes, including fixing of cable glands, supply and fixing of PVC shrouds, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
3.5Cx 185 sqmm Al conductor
SUPPLY
ERECTION
3Cx185sqmm copper conductor
SUPPLY
ERECTION
3Cx 70 sqmm copper conductor
SUPPLY
ERECTION
4Cx2.5sqmm copper conductor
SUPPLY
ERECTION
CABLE TRAYS : Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. tender drawing of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.
300 mm wide Straight run cable tray.
SUPPLY
ERECTION
Supply and installation of 100 mm wide galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer- in-Charge.
SUPPLY
ERECTION
Supply, fabrication and installation of 0.91 mm (20 gauge) GI sheet covers for all sizes cable trays, including necessary hardware, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer- in-Charge.
SUPPLY
ERECTION
EVERCREST PROJECTS PVT LTD.
PRANAM HVAC ENGINEERING PVT LTD
BATLIBOI ENVIRONMENTAL ENGINEERING LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .