| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC | |
| 3 | Rejected-Technical | - | Rejected-Technical Being L1 |
Tender Value
₹25.1 L
EMD Value
₹46,000
Closing Date
15 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN Elect Divn No II
XEN Elect Division No II HPPWD Shimla-2
Providing EI work
2022_PWD_57403_1
ED.II.GA.Tender/21-22-10045-46 dated 25.02.2022
Open Tender
Electrical Works
Item Rate
30 days
Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Elect Divn No II
₹46,000
26 Mar 2022
4 Mar 2022
16 Mar 2022
4 Mar 2022
15 Mar 2022
4 Mar 2022
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/ PVC insulated single core copper conductor cable as required.Group C.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/ recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No. HRFRLS /PVC insulated single core copper conductor cable of same size for earthing as required.2x2.5 Sq. mm.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface /recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No. HRFRLS /PVC insulated single core copper conductor cable of same size for earthing as required.2x6.0 Sq. mm.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No. HRFRLS /PVC insulated single core copper conductor cable of same size for earthing as required.2x10 Sq. mm.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.PVC insulated HRFR LS Copper conductor 1.5 Sq. mm.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/ PVC insulated single core copper conductor cable as required.Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2x2.5 Sq. mm.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-12 way
Double door-8 way
Single door-4 way
Double door-16 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Double pole. Cat-A.
Triple pole & Neutral. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB),having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps. Cat-A.
63 Amps. Cat-A.
40 Amps. Cat-A.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Nonreturn valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages , electrical connections, safety valve connections, testing and commissioning etc. as required:-
25 liter capacity water heater (cat-A)
15 Liter capacity water heater (Cat-A)
Providing and installation of light duty,plastic body,ventilating fan of following sizes in the existing opening,by means of suitable rag-bolts /nuts,including making the hole to suit the size of the above fan,making good the damages ,connections ,testing and commissioning etc. as required complete in all respects to the satisfaction of the Engineer-in-charge
Ventilating Fan ,Light Duty,(Plastic body) 250mm sweep
Ceiling mounted fan 130 mm
Providing and installation of following type of surface / recess mounting slim square / round type LED Downlight with two years warranty in white finish with anti glare polycarbonate diffuser and separated energy efficient constant current, non-integral, electronic driver, suitable for input voltage: AC 220-240V, 50/60 Hz complete with all accessories, including making suitable cut-out in the existing ceiling, connections, testing and commissioning etc. as required. Make:- Philips, Twinkle, GE or any other approved by Engineer-in-Charge.
LED Downlight 36 watt
LED Downlight 15 watt
LED Downlight 22 watt
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
Providing and installation of following type of LED Batten 40 watt with two years warranty in white finish with anti glare polycarbonate diffuser and energy efficient constant current,non integral,electronic driver,suitable foe input voltage:AC 220-240 V,50/60 HZ complete with all accessories ,connections,testing amd comissioning etc as required.Make: Philips, GE, Twinkle or any other approved by Engineer-in-charge
Supplying and fixing bulk head luminaires fitting with die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket .
Providing, laying and fixing of one No. aluminium conductor , PVC insulated and PVC sheathed, armoured /XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-4*16 sqmm
Supplying and fixing Busbar Chamber with 2000 Amp 4 strip aluminium busbar complete with connections etc as required complete in all respects
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS /PVC insulated single core copper conductor cable for earthing as required.
M/s Naresh Elecric Works
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_86636.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .