Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.4 CrAccepted-Finance | ₹10.4 Cr | L-1 | Accepted-Finance L-1 |
| 2 | L-2₹10.8 CrAccepted-Finance H 4 SURYA VIHAR CO OP HO SO LTD BEHIND MUNICIPAL OFFICE ADARSH ROAD KULGAON BADLAPUR E DIST THANE 421 503 | BADLAPUR | THANE | MAHARASHTRA | 421503 | ₹10.8 Cr | L-2 | Accepted-Finance L-2 |
| 3 | L-3₹10.9 CrAccepted-Finance MECHATRONICS HOUSE MUMBAI BANGALORE BYPASS HIGHWAY WARJE PUNE | PUNE | MAHARASHTRA | 410301 | ₹10.9 Cr | L-3 | Accepted-Finance L-3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Required documents are not submitted as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Required documents are not submitted as per NIT |
| Sl No | Description | Qty | Unit | Mechatronics Systems Pvt Ltd L3 | FRIENDS ENGINEERING CORPORATION L1 | Shree Siddhivinayak Industries L2 |
|---|---|---|---|---|---|---|
| 0.00Item Description | ||||||
| 1.001. Providing & fixing Full Bore Electromagnetic Meters (Battery Operated) Suitable for volume flow measurements of liquids and water application within distribution network with EPDM Liner ,Hastelloy Electrodes ,corrosion resistance coating of category C4 with standard calibration certificate with GSM /GPRS Connection module with IRDA interface for Communocation | ||||||
| 2.00 | 1.1 Battery powered,Magnatic Flowmeter, DN 50 | 12 | Number | 11,50,000 ₹1,38,00,000 | 11,18,000 ₹1,34,16,000 Lowest | 11,30,000 ₹1,35,60,000 |
| 3.00 | 1.2 Battery powered,Magnatic Flowmeter, DN 80 | 6 | Number | 13,20,000 ₹79,20,000 | 13,08,000 ₹78,48,000 Lowest | 13,15,000 ₹78,90,000 |
| 4.00 | 1.3 Battery powered,Magnatic Flowmeter, DN 100 | 16 | Number | 16,60,000 ₹2,65,60,000 | 16,40,000 ₹2,62,40,000 Lowest | 16,50,000 ₹2,64,00,000 |
| 5.00 | 1.4 Battery powered,Magnatic Flowmeter, DN 150 | 14 | Number | 21,25,000 ₹2,97,50,000 | 21,00,000 ₹2,94,00,000 Lowest | 21,10,000 ₹2,95,40,000 |
| 6.002. Dismantling joints- Providing, erecting and commissioning M.S. Dismantling joint as per requirement and Department‘s approved drawing and specifications, including machining and rubber rings and suitable for 16 kg/cm2 working pressure with required flanges of suitable size with nut bolts etc. complete. The joint should have through long bolts so that during normal working pressure there should be no sliding movement of sliding flanges. L.O.F. ( length over flange ) should not be less than 75% of dia. | ||||||
| 7.00 | 2.1 100 mm dia | 16 | Number | 9,000 ₹1,44,000 | 8,700 ₹1,39,200 Lowest | 8,900 ₹1,42,400 |
| 8.00 | 2.2 150 mm dia | 14 | Number | 14,000 ₹1,96,000 | 12,900 ₹1,80,600 Lowest | 13,000 ₹1,82,000 |
| 9.00 | 3. a) MS front & Wall Mounted 760(H) X760(W)X300(D) RAL7035, IP42, 1.5 mm gland plate b) RTU for connecting FT and PT c) Power supply,120-230V AC Input,24DC, 5A output d) SCADA PC (i7 , 8GB RAM, 1TB SATA HDD , MS office , Antivirus, 19" Monitor, Keyboard,Mouse, Windows 10 OS) Loaded with 512 SCADA tags & DNP3 License | 1 | Number | 1,60,00,000 ₹1,60,00,000 | 1,55,00,000 ₹1,55,00,000 Lowest | 1,58,00,000 ₹1,58,00,000 |
Tender Value
₹10.6 Cr
EMD Value
₹5.3 L
Closing Date
20 Feb 2026, 12:00 pmClosed
SE(MMR)
office of the Superintending Engineer MIDC Dombivli
M and R to WSS to Barvi Water Supply System Providing lowering fixing electromagnetic meters at tapping provided to 27 villages in KDMC 2nd call
2026_MIDC_1273004_1
MIDC/DOM/2025-26/18
Open Tender
Civil Works
Item Wise
270 days
Dombivli Industrial Area
Please refer tender document
2 documents required · 2 mandatory
₹29,500
₹5.3 L
21 Apr 2026
30 Jan 2026
23 Feb 2026
30 Jan 2026
20 Feb 2026
6 Feb 2026
30 Jan 2026 - 3 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Item Description | - | - | - | - |
| 1 | 1. Providing & fixing Full Bore Electromagnetic Meters (Battery Operated) Suitable for volume flow measurements of liquids and water application within distribution network with EPDM Liner ,Hastelloy Electrodes ,corrosion resistance coating of category C4 with standard calibration certificate with GSM /GPRS Connection module with IRDA interface for Communocation | - | - | - | - |
| 2 | 1.1 Battery powered,Magnatic Flowmeter, DN 50 | 12 | Number | - | - |
| 3 | 1.2 Battery powered,Magnatic Flowmeter, DN 80 | 6 | Number | - | - |
| 4 | 1.3 Battery powered,Magnatic Flowmeter, DN 100 | 16 | Number | - | - |
| 5 | 1.4 Battery powered,Magnatic Flowmeter, DN 150 | 14 | Number | - | - |
| 6 | 2. Dismantling joints- Providing, erecting and commissioning M.S. Dismantling joint as per requirement and Department‘s approved drawing and specifications, including machining and rubber rings and suitable for 16 kg/cm2 working pressure with required flanges of suitable size with nut bolts etc. complete. The joint should have through long bolts so that during normal working pressure there should be no sliding movement of sliding flanges. L.O.F. ( length over flange ) should not be less than 75% of dia. | - | - | - | - |
| 7 | 2.1 100 mm dia | 16 | Number | - | - |
| 8 | 2.2 150 mm dia | 14 | Number | - | - |
| 9 | 3. a) MS front & Wall Mounted 760(H) X760(W)X300(D) RAL7035, IP42, 1.5 mm gland plate b) RTU for connecting FT and PT c) Power supply,120-230V AC Input,24DC, 5A output d) SCADA PC (i7 , 8GB RAM, 1TB SATA HDD , MS office , Antivirus, 19" Monitor, Keyboard,Mouse, Windows 10 OS) Loaded with 512 SCADA tags & DNP3 License | 1 | Number | - | - |
stage.html
html • 0.04 MB
techsummary_2191540.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.07 MB
BOQ_2191540.xls
BOQ • 0.30 MB
Previouslyapprovedqueries.pdf
Additional Documents • 3.91 MB
TD.pdf
Tender Documents • 2.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].