Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹38.1 L+₹2.1 L (5.94%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹39.2 L+₹3.2 L (8.94%)Rejected-Finance S NO 7 3 FLAT NO 4 HILL VIEW RESIDENCY LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹42.4 L+₹6.4 L (17.9%)Rejected-Finance OFFICE E2 MANALI ARCADE NEAR D MART PADMAVATI PUNE SATARA ROAD PUNE MAHARASHTRA 411009 PUNE MAHARASHTRA 411009 | PUNE | MAHARASHTRA | 411009 | L4 | Rejected-Finance High Rate |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8317 SPECIAL REPAIR TO BLDG NO P 87 OFFRS MESS OF AIPT AND APTC DEPOT UNDER GE C PUNE
2022_MES_527623_2
8317 SPECIAL REPAIR TO BLDG NO P 87 OFFRS MESS O
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹96,000
Yes
27 Aug 2022
23 Jun 2022
29 Jul 2022
23 Jun 2022
27 Jul 2022
4 Jul 2022
Amount
Demolition of Brickwork or stone/boulder masonary built in cement Mortar including all quoins, arches , pillars etc but excluding ashler facing , dressed stone works compete all as directed.
Demolition of reinforced cement concrete of any description and in any position including rubbish off outside of MOD land complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15 cm thick (below or above ground level) and removing debris out side defence land complete
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6 compete all as specified and directed.
Dismantling of ceilimg/boarding, any description fixed in any position with nails i.e. in false ceiling and wall lining/partition etc and similar position complete.
S&F Gl frame work of size 605 x 605 mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete. Note:- ceiling board will be measured & paid separately
M&L for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and finally applying two coats of oil bound destemper over a coat of primer including thin layer of wall care putty to provide smooth finish of ceiling complete all as specified and directed. Note :- Frame work for ceiling shall be be measured and paid separately.
M & L for decorative POP cornices/ moulding of pattern of cross section area exc 13 sqcm and not exc 25 sqcm complete all as specified and directed.
M & L for decorative POP cornices/ moulding of pattern of cross section area not exc 13 sqcm complete all as specified and directed.
Taking down Shutters of any description n exc 1 sqm each and refixing in the same opening after carrying out necessary adjusting / minor repairs etc complete all as specified and as directed.
Taking down chowkats or frame with shutter, without taking off shutter from the frames not exc 1.5 Sqm each including making good disturbed portion all as directed.
Taking down chowkats or frame with shutter, without taking off shutter from the frames area exc 1.5 sqm but not exc 4sqm each including making good disturbed portion all as directed.
S&F aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed
S&F anodised powder coated aluminium door shutters (single / double leaf) or partitions, aluminium section weighing 0.55kg/m with including 5.00mm thicktinted sheet glass ordinary quality fited with aluminium door shutter exc 0.50 sqm in each pane including necessary joining cleats, al powder coated glazing clips, rubber neoprene packing, Al powder coated handles 2 Nos in each door, Al powder coated tower bolt 02 Nos, hinges 03 Nos, Al powder coated snap beading, screws, door stopper 01 No etc. complete all as specified
S&F three track sliding window with two or more shutter with including using 5 mm thick tinted glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F fixed louvered glass ventilators with and including 5mm thick frosted / pin headed glass and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed. (a) SP - 20048 (b) Glazing clips - 19352. complete all as specified and directed by Engineer-in-Charge.
Providing and fixing vertical venetion blinds 100 louver width quality of approved make fabric made of 100 % polyster woven fabric thickness 0.4 mm width of acralic coating resistance to cracking and fraying and treaed for dust repellency , vertually maintance free having plastic bottom chain thickness of 0.5 mm and dia 3 mm plastic with metal bottom weight 116.2 mm x48.30 mm and suitable coating on exteriaor including all fixures and fitting complete in all respect as design/colour/shade including requisite istallation bracket etc as required for installation at site with anchoring arrengement including taking down old unserviceble blind complete all as specifed as directed
M&L 20mm thick Granite (of any type) work (table rubbed and Polished) in steps, jambs, pillars, window-cills, cooking platforms, wall cladding and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as in vertical support with edges polished / rounded or counter top for wash basin as ordered incuding cutting circular or eliptical hole in granite slab and fixing in position complete and ensure best adhesion to surface complete
M&L for machine cut cudappah stone slab 20-25mm thick as stand for kitchen platform cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab on vertical supports of kitchen platform / WHB counter type complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Taking up or down steel water tubing and connection complete all as specified and directed of folowing sizes
15 mm dia bore
20 mm dia bore.
S&F in medium grade galvanised GI pipe with all fittings and fixed complete fixed to walls and ceilings or laid in floors all as specified and directed of followig sizes :- .
15mm dia bore
20mm dia bore
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as directed :
Supply and fixing 20mm dia gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete
Supply and fixing 25mm dia gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete
Demolition and breaking up drain pipes 75 mm /100 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete.
M/L in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors as specified and directed
M/L in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors as specified and directed
S&F PVC (SWR) bends plain 110 mm bore
S&F PVC (SWR) bends plain 75mm bore
S/F PVC (SWR) Branch piece single (single Y) equal or unequal 110mm dia with door access
S/F PVC (SWR) Branch piece single (single Y) equal or unequal 75mm dia with door access
S&F for 75mm dia SWR junction (single 'T') equal or unequal with door access.
S&F for 110mm dia SWR junction (single 'T') equal or unequal with except door access.
Supply and fixed rotational moulded polyetylene water storage tanks (cylindrical vertical with closed top) of 1000 Litres capacity hoisted and fixed in position and connecting up pipes and ball valve complete set of PTMT, securing access covers including dismantling of old tank all as specified and directed
S&F in repairs 25 mm bore ball brass valves high pressure with polythene float and fly nut , screwed for iron pipe complete all as specified and directed.
Demolition of cement concrete of any description and in any position on roof slab as in padding/mud phuska etc complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone agg asin PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface fineshed enen and smooth without using extra cement including necessary liquid water proofing chemicals @ 200ml per bag of cement and corrying out test by flooding water for 7 days for leakage & seapages and rectifying the same to the entire satifaction of GE complete all as specified and directed by the Engr-in-charge. (Note: Liquid WP materials shall be measured and paid separately)
Supply only liquid water proofing chemical
M & L water proofing treatment to RCC roof slab, walls, chajjas ets, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing treatment. (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying 4mm thick weighing not less than 3.9 kg/Sqm Atactic polypropylene polymer (APP) modified bitumen based prefabricated five layer water proofing approved membrane reinforced with non wovwn polyester matt black finished over compatible primer at 0.40 ltr/Sqm of density at 25 degree centigrade 0.87-0.89 kg/ltr and viscosity 70-160 cps or cold sticker and torch application of membrane with minimum 100mm overlap both ways after necessary preparation of surface as per manufactures instruction all as specified and as directed by the Engr-in-charge. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specifed & as directed by Engr in Charge.
M& L Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete all as specified and directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed
M&L for rendering 15mm thick cement plaster 1:4 on fair faces of concrete surfaces of wall finished with sponge finish all as specified and directed.
M&L for 10mm thick plastering in CM 1:6 on concrete on fair faces of bricks or concrete surfaces of wall finished even smooth with layer wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade by mchanical means : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed.
M&L for preparation of newly plastered surface and applying two coats of oil bound distemper over a coat of primer including thin layer of wall care putty to provide smooth finish of wall surface complate all as specified and as directed by the Engr-In-charge.
M&L for old plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade by mchanical means : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed. (Height of bldg G+2)
Complete removal of existing treatment on wall and M&L for applying two coats of oil bound distemper over a coat of primer including filling of cracks, holes and including leveling the surface which undulation found with thin layer of wall care putty to provide smooth finish of wall surface complete all as specified and as directed by the Engr-in-charge
Preparing Old plastered surfaces and applying two coats of oil bound distemper on ceilling all as specified.and directed
M&L preparation Old steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint all as specified and directed.
M & L preparing surfaces of old wood or wood based material of any description and girth not otherwise described treating and treated with tar or cold tar black paint complete all as specified and directed
M&L Distempering Two or more coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour complete all as per manufacturer's specification complete all as directed.
Cutting holes into or through Stone walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l using liquid water proffing compound area exc 150 sq. cm but n exc 400 sq cm all as specified and directed.
Dismantling and taking down out door unit of split AC /AC stand upto capacity 3 Ton carefully from roof of building and placing at safe distance for carring out roof treatment of work and Refixing the outdoor unit at same position including reconnecting electric and copper tubing work after completion of roof repairs complete as directed by Engineer-in-charge (Note : Any Damage to copper tubing /Insulation/Electrical wiring of outdoor unit will be make good by the contractor without any extra cost including gas charging as per Requirement) (Height of bldg G+3)
M&L for 75mm thick PCC (1:3:6) type C-2 (using 20mm graded aggregate) as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
S&F in repairs Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed (Aluminium die cast body) complete all as directed .
M&L for vitrified tiles light shade 600 x 600 x 10mm thick (square/ rectangular) polished as in floors etc. set and jointed in neat cement slurry and pointed in white/ colored cement to match, laid over and including cement screed bed 15mm thick in cement mortar 1:6 complete all as specified.
M&L for vitrified tiles light shade 600 x 600 x 10mm thick (square/ rectangular) polished as in skirting etc. set and jointed in neat cement, laid over and including 10mm thick plaster in CM 1:4 as a backing coat with filleting triangular shape on top of tiles etc complete all as specified.
Taking down old u/s point wiring( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants, regulators, light fittings etc. removing materials for taking credit and making good the disturbed surfaces of walls/floors/ceiling etc.complete all as specified.
Taking down Main switches/DBs of any make and type including teak wood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified.
Taking down ceiling fan/ exhaust fan/Wall fan of any sweep, keeping with safe custody and refixing the same with replacement of 3 core PVC insulated PVC sheated multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal after over hauling the fan, Painting of ceiling fans with one coats of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc. complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area) single core, PVC insulated and unsheathed stranded FRLS copper cable 1100 volts grade, IS - 694 marked in PVC casing & caping heavy duty ISI marked including all accessories with PVC modular surface boxes inluding modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-
(a) One light/fan point controlled by one, One way switch all as specified
(c) One three pin 5 Amps socket outlet point controlled by one No one way switch on independant board all as specified
(b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board all as specified
(d) One bell/buzer point controlled by one bell push complete all as specified.
All as per item No.66 above but with 2.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in Existing PVC conduits totally concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. as per site requirement and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-
a) One light/fan point controlled by one, One way switch complete all as specified
b) One 5 pin 5 Amps Socket outlet point controlled by one No one way other switches on same board including earth wire.
(c) One Five pin 5 Amps socket outlet point controlled by one No one way switch on independant board all as specified
All as per item No.68 above but with 2.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.
S & F modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F modular switch Bell push, flush type, 5 amp complete all as specified.
S&F bell electrical ding dong including hard PVC board ISI marked complete all as specified
S&F ceiling rose surface type three terminals complete all as specified and directed.
S & F Modular type stepped electronic fan regulator 2 module, 1 to 5 steps all as specified & directed
S & F in replacement of LED light fitting surface and wall mounted LED batten with Aluminium housing & integrated electronic driver complete in all respect of 10 Watt capacity all as directed. Cat Part No BCLSB 10 WH of Make - Bajaj or equivalent as listed in list of makes Appdx 'A'.
Supply and fix in replacement LED Tube light fittings Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver 20 W LED complete including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector. Conforming to Cat Part No.ENDURALINEARNEOBS20WLED865SPCWH Make :- Havells or equivalent as listed in list of makes Appdx 'A'.
S & F in replacement of round recessed mounted AL die - cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation of 15 Watt LED downlighter of white/neutral white color temperature etc. prewired and all accessories complete all as specified and directed. Make - Cat part No. BGSLO SLEEK 15W WH RD of Bajaj or equivalent as listed in list of makes Appdx 'A'.
S & F LED in replacement security light of luminaries 30 Watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired Conforming to Havells Cat Part No. BCLST 30W LED I or equivalent as listed in list of makes Appdx 'A'.
S&F MCB TPN DB 4 way double door with 200 Amps rated busbar 415 V, fixed to well and connecting complete all as specified.
S & F for MCB DB, SPN, sheet metal enclosure, 8 way with 200 Amps rated bus bar double door, fixed on and connecting complete all as specified and directed.
S & F DB vertical 4 way TPN double door, recess mounted/wall mounted with including MCCB as incomer and outgoing MCB SP/TP, 3 pole V-Tec of 100 Amps rating capacity & breaking capacity 16KA, all as specified and directed . Note : MCCB is pre-fitted at factory & rates deemed to be including in quoted price.
S & F for MCB Single pole rated capacity 6 to 32 Amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified.
S & F for MCB double pole of rated capacity 32 Amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified.
S & F for MCB four pole of rated capacity 40/63 Amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
S & F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified.
M & L for Sub main wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through non-metallic PVC rigid conduit of suitable size, ISI marked and its accessories including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor complete including taking down old submain wiring all as specified. Note:- Two run of 4 sqmm conductor & one run of 4 sqmm conductor and one run of conduit will be measured as on RM
M & L for Sub main wiring with 4 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through non-metallic PVC rigid conduit of suitable size, ISI marked and its accessories including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor complete including taking down old submain wiring all as specified. Note:- Four run of 4 sqmm conductor & one run of 4 sqmm conductor and one run of conduit will be measured as on RM
M & L for Sub main wiring with 4 runs of single core 6sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through non-metallic PVC rigid conduit of suitable size, ISI marked and its accessories including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor complete including taking down old submain wiring all as specified. Note:- Four run of 6 sqmm conductor & one run of 6 sqmm conductor and one run of conduit will be measured as on RM
M & L for Sub main wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through non-metallic PVC rigid new conduit of suitable and appropriate size, ISI marked and its accessories including one run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor complete all as specified. Note:- Four run of 10 sqmm conductor & one run of 10 sqmm conductor and one run of conduit will be measured as on RM
Taking down indoor/outdoor unit/copper tubes of Split/Window ACs of any capacity and make depositing to MES store or keeping in safe custody and refixing the same to its original position after completion of B/R repair works including servicing/replacement of unserviceable minor parts and testing for proper operation all as directed.
Taking down water heater (Geyser) of any capacity , depositing to MES store or keeping in safe custody and refixing water heater (Geyser) to its original position after completion of B/R repair works including provision of new nuts/bolts/fastner/GI pipes of required length and sizes as per site requirement all as specified and directed.
M & L servicing of geyser of 1.5/2 KW capacity, including cleaning, overhauling, spray painting with one coat of synthetic enamel paint including writing MES no and refixing the geyser to its original position all as specified.
Supply & fix in replacement 15mm dia and 450mm long PVC connections pipe with brass hexagonal adapters both side suitable for Cold water as per requirement complete all as specified.
Supply & fix in replacement 15mm dia and 450mm long PVC connections steel braided pipe with brass hexagonal adapters both side suitable for Hot water as per requirement complete all as specified.
S & F down rod of suitable length 2/4/6 feet long as per site requirement all as specified
Taking down carefully Existing light fittings of any type and description from wall depositing depositing to MES store and refixing to its original position after completion of B/R repair works all as directed by Engineer-in-charge.
M & L in replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part - I including RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (Note:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .