| Sl No | Description | Qty | Unit | M/s SONOWAL ASSOCIATE L1 |
|---|---|---|---|---|
| 1.00Supply, Installation and Comisioning of Pontoon and Pump set along with anchoring devices. | ||||
| 1.01 | HDPE pontoon : Supply and Installation of HDPE pontoon is suitable for 1 Nos. of vertical submersible Pump set of 10/20HP. Consist of follwing items;
1.Pontoon Size-3 x 4 mtr
2.Submersible pump cage.
3.Chain pulley mounting structure
4.Hardware - SS304
5. MS Part Painting - PU | 3 | Job | 2,78,490.37 ₹8,35,471.11 Lowest |
| 1.02 | Supply, Installation and commissioning of 20 H.P Submerged Job Centrifugal Pump Set of KBL (Kirloskar) Make/ Brand (Model : NS100/32Ni) conforming to relevant IS Specification with 60 LPS minimum discharge at 10.00 metre head (approx.), working efficiently at head range 6.00 metre to 20.00 metre with 100 mm delivery size for both vertically bottom rested in water body or vertically suspended in water body from a floating platform like,
pontoon having Class-F or appropriate class insulation conforming to relevant IS Specification coupled with 3 ph, 415 V, 50 Hz, 1500 RPM Submerged/ ARS/ Squirrel Cage Induction motor with overall efficiency of 75 % to be connected to power source of 400/440 volt, 50 Hz, 3-ph complete along with Starter Panel (automatic Star Delta/ Oil Immersed/ ATS Starter with protection as per IP68
against under voltage, overload, etc. in sheet enclosure of relay range 0-30 A), coupling, H.D Base Frame fitted in accurate alignment, Power Cable and Control Cable of requisite rating & length, load chain of required length including fitting, fixing of all necessary accessories and transportation of all materials to the site complete as directed. The job includes necessary electrical connection to Starter Panel with motor, etc. including supply of all necessary materials and installation of Pump Set in proper position with accurate alignment including testing & mmissioning at site with full loadcondition complete as directed.
Besides Class-F insulation protection, Starter Panel should provide protection against (a) overload, (b) oil contamination, (e) dry running, (d) high temperature, (e) reverse phasing, () under voltage.
To avoid Pump dry running Control Panel should be equipped with Ammeter, Auto Manual Selector Switch, Fuse Unit Switch, Float Switches, Voltmeter, Phase Indicator Lamp, etc.
NB: Technical Specification of Pump Set is shown in Annexure-I | 3 | Set | 7,35,761.92 ₹22,07,285.76 Lowest |
| 1.03 | Anchoring of Pontoon : Supply and Installation of Anchoring device for Pontoon | 6 | Job | 90,560.09 ₹5,43,360.54 Lowest |
| 1.04 | Supporting Pillar : Base pillar for support pontoon anchoor. | 6 | Job | 23,379.38 ₹1,40,276.28 Lowest |
| 2.00Construction of Control Room | ||||
| 2.01 | Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. | 11.37 | Cum | 707.76 ₹8,047.23 Lowest |
| 2.02 | Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing | 11.56 | Sqm | 818.38 ₹9,460.47 Lowest |
| 2.03 | CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately). | 0.58 | Cum | 9,535.16 ₹5,530.39 Lowest |
| 2.04 | Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed | 15.72 | Qntl | 13,260.12 ₹2,08,449.09 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
23 Aug 2025, 1:00 pmClosed
SE Dibrugarh Circle Irrigation
O/o SE Dibrugarh Circle Irrigation
Lift Irrigation Scheme
2025_ID_46105_1
NIT 26/2025-26
Open Tender
Civil Works – Lift Irrigation Schemes
Item Rate
Lahowal
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,000
₹3.5 L
Yes
6 Sept 2025
2 Aug 2025
23 Aug 2025
2 Aug 2025
23 Aug 2025
2 Aug 2025
Amount
Supply, Installation and Comisioning of Pontoon and Pump set along with anchoring devices.
HDPE pontoon : Supply and Installation of HDPE pontoon is suitable for 1 Nos. of vertical submersible Pump set of 10/20HP. Consist of follwing items; 1.Pontoon Size-3 x 4 mtr 2.Submersible pump cage. 3.Chain pulley mounting structure 4.Hardware - SS304 5. MS Part Painting - PU
Anchoring of Pontoon : Supply and Installation of Anchoring device for Pontoon
Supporting Pillar : Base pillar for support pontoon anchoor.
Construction of Control Room
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing
CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered). A. Column
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered). B. Beam
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered). C. Slab
RCC work in slab, abutment cap and above abutment, pier cap, pedestals, dirt wall etc. in proportion 1:1½:3 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including necessary curing, dewatering etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plastering including clearing surface and curing, complete as directed. b) In cement mortar 1:4
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 40 mm nominal bore
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces
Bank Protection Work
Earthwork in cutting in river bank etc. to the design section and grade and removing the spoils to a safe distance including cutting, uprooting and removing trees upto 15 cm dia, uprooting and removing roots and stumps etc, including excavating the earth boulder sausages of 1.00 M dia, 50 cm under river bed shape, size and grade etc. with all lead and lift, complete as directed.
Collection of hard broken stone of size 13 mm to 38 mm from blasted boulder free from dust and dirt and foreign materials including stacking at quarry site, complete as directed.
Collection of one man size 25 cm to 30 cm hard river boulder including stacking in measurable stacks of not more than 1.00 M height at quarry site and making payment of forest royalty etc, complete as directed.
Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed A) For Normal Road upto 25.00 KM (With Contractor's Profit & GST)
Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed (B) For 1st KM of Quarry Road (ii) With Contractor's Profit & GST
Labour charge for spreading hard river gravel/broken stone of size 13mm to 38mm to the required thickness including ramming, dressing the seat before laying the materials as directed with lead up to 30m & lift upto 1.5m complete as directed.
Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed.
Construction of 1.00 M x 1.00 M rectangular boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.. With river boulder
Provisional estimate for 11/0.43, 25 KVA Pole mounted Sub-Station including complete commissioning of the scheme
Surveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directed
(A)For 0 to 500 m length
(B) For every subsequent 100 M beyond 500 M Length
Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line
Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. 9.75 Metres ( (a)for 6 or more poles) (I) Refilling with Hard Soil :-
Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed a)75mmX40mmX6mmX2200mm
Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed b)100 mm X 50 mmX 6 mm X220mm
Supplying and erection of GI Angle Cross Arm on Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed Size 50mm × 50mm × 6mm, 2200 mm long
Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed (A) In Hard Soil with Boulder
Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed
11 KV Pin Insulator Polymeric
Supplying, Laying and Erection of Conductors of following size and specification for Overhead Line, binding to Insulators and Tensioning with Uniform Standard Sag including Jumpering connection as directed. 6.7.1 AAA Conductors (D) AAA Raccoon Conductor-7/3.81mm
Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps
Supplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp)
Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymer body
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire
Supply including Erection of 5 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 25 kVA, 11 kV/0.433 kV (5 Star Dyn) - Al wound (A) Cost including Supply of Transformer
Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed
Supplying including erection of powder coated LT Feeder Panel for 25 kVA DTR (800mm × 1000mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 63 A 415 V FP MCCB, making necessary connection through copper cable complete as directed.
Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed
Supply and Laying of 3½(Three and half) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed. Size of Cable : 70 mm2 × 3.5 Core ( Single Line)
Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm
Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed.
Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity : 25 kVA, 11 kV/0.433 kV
Liaisoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till Commissioning of the HT Line/Substation, Preparation of all necessary documents like Agreement and Affidavit required for new Power Connection, obtaining No Objection Certificate from Forest Department where necessary complete all arrangement for charging the Installation as required and as directed.
Supplying including fitting, fixing & connection of TPN, 415 V, AC MCCB of following current ratings as main incomer in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed 100 Amp, Breaking Capacity 35/36 kA
LT CAPACITOR BANK : Supplying fitting fixing of LT Power Capacitor 415 Volt AC 3 φ (Single Unit) of following KVAR Rating and making connection with Busbar in the existing Panel. The Capacitor is to be placed in existing Platform. Size : 6 kVAR
IRON ANGLE STAND FOR CAPACITOR BANK : Supplying fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of M S Angle of size 30 mm x 30 mm x 5 mm with 4 Nos. legs 400 mm high and cross pieces having Bakelite Sheet Horizontal Platform as directed. Size of the Frame : (300 mm x 300 mm) x 400 mm
Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed.
Load Security to be paid to APDCL (Approx.)
LT control panel
EARTHING
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire
Control Panel :-Supplying, installation, testing & commissioning of indoor type floor mounted, cubicle type compartmental, dust and vermin proof (as per IP-54) main LT Control Panel Board of following capacity combination and of given size, made out of 16 SWG CR Sheet and 40mmх40mmх6mm angle having four nos. of legs 400 mm long at the bottom, with folded and welded construction having dismantling doors at the back, surface chemically treated and Siemen's grey powder coated, containing Al. strip busbar having minimum current density of 1.2 Amp/mm2 R-Y-B-N colour coded with heat shrinkable insulating sleeves containing all incoming and outgoing electrical accessories as specified, neatly installed and internally wired with best quality multi- strand, PVC insulated Single core unsheathed, HRFR copper wire (switch gears above 100Amp rating to be connected to busbar through Aluminium strip of suitable size) having cable incoming & outgoing provision at the bottom through gland plates complete including necessary excavation of trench and C C Work as directed (Details at Enclosed A)
Supply, Laying & Installation Delivery Pipes & Accessories Including Surge Tank
CIDF sluice valve : Supply, Fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation, need for water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10, part-I, Table-D. All materials construction and components should strictly conform to IS: 14846 – 2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing materials and painting in complete as directed Size : 150 mm dia.
CIDF Reflex Valve : Supply, Fitting-fixing of Heavy duty CIDF Reflex valve, swing check type, with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table- D and the material, construction and all components should strictly conform to IS : 5312 (Part-I) – 2004 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed. Size : 150 mm dia.
Supply of Flexible rubber hose pipe as per construction schedule with required nos. of wire reinforcement inside at different layers, without / with MS built in type flange coupling on both ends having drilled as per BSS No. 10, Part - I, Table - D. The hose pipes should be capable of withstanding a pressure equal to 1.5 times the designed working pressure without failure as per IS : 443-1975 and also withstand vacuum drawn upto 625 mm of mercury (approx.). The schedule of construction of the hose pipe should conform to IS : 3549-1983. (With MS built in type flange) 150 mm nominal dia X 4.5 mtr in length
Supply, fitting-fixing of delivery pipes of 150 mm dia GI/ fabricated GI pipes (HD of repute brand with ISI marked) with flange at both end/ wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.
Supply of G.I Equal Tee of 80/ 100 mm Dia. Complete as directed.
Fitting-fixing of MS/ GI Tee of 150 mm with GI/ fabricated GI pipes with flange at three end and pipe jointing sets, including painting as per drawing & specification as directed
Fitting-fixing of MS/ GI bend of 150 mm dia x 45° /90° /120° with GI/ fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing & specification as directed.
Surge Tank : Supply, fitting-fixing of Surge Tank of size 900 mm dia x 1250 mm long made of 4 mm MS plate with Raiser assembly of size 75 mm dia x 6.0 M long and S-bend of size 200 mm x 1600 mmL made of 4 mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified CC foundation by nuts & bolts of suitable size as per drawing & specification as directed.
Underground PVC Pipe Distribution System
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil
Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
A) 160mm dia
B) 110mm dia
Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.
Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.
Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed.
Estimate for construction of Spout Chamber ( 12 Nos.)
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mentioned in the approved drawing and complete as directed and specified. (A) In ordinary soil
CC work in proportion 1:2:4 in foundation / abutment /piers / wing walls etc. with hard broken stone aggregate of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
CC work in proportion 1:3:6 in foundation / abutment /piers / wing walls etc.with hard broken stone aggregate of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered
Supplying, fitting, fixing 110 mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification including local carriage, complete as directed.
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed.
Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
Construction of Boundary Wall
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).
Shuttering (Column)
Shuttering (Beams) with out props
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. In proportion 1:4
12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required omplete as per the direction of Engineer-in-charge. 16.70.1 Made of G.I. wire of dia 4 mm
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.
Construction of Signboard
Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. (As per approved rate of CE))
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .