Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.4 L+₹2.8 L (8.02%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹39.1 L+₹3.5 L (9.95%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹39.2 L+₹3.7 L (10.3%)Rejected-Finance KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹39.9 L+₹4.4 L (12.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Aug 2021, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
REPAIR AND MAINTENANCE OF WATER MAIN LINE AND CONNECTED DISTRIBUTION SYSTEM IN MAHAR, FD HOSPITAL UNDER GE DIPATOLI MIL STATION
2021_MES_459747_1
8000/1730/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
Dipatoli
Class E
Category a(ii)
8 documents required · 8 mandatory
₹500
Yes
GE Dipatoli
₹40,000
Yes
21 Sept 2021
15 Jul 2021
14 Aug 2021
15 Jul 2021
12 Aug 2021
4 Aug 2021
Amount
Excavation in trenches n. exc 1.5 m width and not exc 1.5 mtr in depth for laying/taking out of pipe in soft/loose soil complete all as specified and as directed.
Returning/filling in trenches including spreading, leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and as directed.
Removal of excavated surplus soil n. exc 50 m and depositing where directed at level n exc 1.5 m above the starting point complete all as specified and as directed.
Suppl, install, test and commissioning of Ductile iron pipe with spigot and socket ends of class k-7 suitable including tyton joint in any length laid in trenches of 100mm size, complete all as specified and direcetd at site.
Description all as per srl item No. 4 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 4 here in before but pipe 250mm dia complete all as specified and as directed. Note of Srl item No.4 to 6:- Excavation and earth work shall be measured and paid seperately.
S&F 15mm bore GI tubes medium grade galvanized with necessary fittings and clamps as per SSR Part -1, laid in trenches /wall/floors concealed or open execution complete all as specified and as directed.
Description all as per srl item No. 7 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 7 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 7 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 7 here in before but pipe 50mm dia complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing or remove to MES store of dia 15mm complete all as specified and as directed.
Description all as per srl item No.12 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No.12 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No.12 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No.12 here in before but pipe 50mm dia complete all as specified and as directed. Note for Srl item No. 12 to 16 Earth work measured and paid separetely
Refixing old steel tubing 15mm bore with necessary connections in old or new positions (laid in Trenches, walls, ceiling, floors etc) with necessary required including new fittings complete all as specified and as directed.
Description all as per srl item No. 17 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No.17 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 17 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 17 here in before but pipe 50mm dia complete all as specified and as directed. Note for Srl item No.17 to 21:- (a) Old GI pipe shall be retrived from Srl item No. 4 to 8. (b) GI fittings required shall be new and shall be provided by the Contractor. Unit quoted rate shall be deemed to be included the cost of new fittings.
S&F in repair 15mm dia stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe with unions and fixed complete with suitable size of fittings like unions, long screw with check nut for iron pipe complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 22 here in before but pipe 25mm dia complete all as specified and as directed.
S&F in repair 15mm bore gun metal globe or gate valve with iron wheel head, screwed both ends with union, long screw with check nut for iron pipe complete all as specified and as directed.
Description all as per srl item No. 25 here in before but pipe 20mm dia complete all as specified and as directed.
Description all as per srl item No. 25 here in before but pipe 25mm dia complete all as specified and as directed.
Description all as per srl item No. 25 here in before but pipe 40mm dia complete all as specified and as directed.
Description all as per srl item No. 25 here in before but pipe 50mm dia complete all as specified and as directed.
Taking up 100mm bore cast iron water mains including all fittings with spigot and socket ends and lead joint including burning out lead joint and recovering lead of CI pipe complete all as specified and as directed.
Description all as per srl item No. 30 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 30 here in before but pipe 250mm dia complete all as specified and as directed. Note of Srl item No. 30 to 32:- Excavation and earth work shall be measured and paid seperately.
Refixing of 100mm bore cast iron pipes with socket and spigot end in trenches with necessary new fittings in any length including cleaning of pipes complete all as specified and as directed.
Description all as per srl item No. 33 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 33 here in before but pipe 250mm dia complete all as specified and as directed. Note of Srl item No. 33 to 35:- Excavation and earth work shall be measured and paid seperately.
M&L in repair for run lead joints of CI pipes of 100mm bore complete all as specified and as directed.
Description all as per srl item No. 36 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 36 here in before but pipe 200mm dia complete all as specified and as directed.
M&L in repair for rubber gasket (Tyton) joint of 100mm dia complete all as specified and as directed.
Description all as per srl item No. 39 here in before but pipe 150mm dia complete all as specified and as directed.
Description all as per srl item No. 39 here in before but pipe 250mm dia complete all as specified and as directed.
M&L for drilling and tapping cast iron water mains in position for branch connections of 15mm bore dia complete all as specified and as directed.
S&F in repair DI bends ( any type radius and angles) tapers any type (straight bend, increasing, decreasing or double socket etc) tee pieces single branch Y junction, double, branches cross (all sockets or socket and spigot) collars caps and plugs suitable for socket and spigot type of any bore complete all as specified and as directed.
S&F in repair 15mm bore bib taps cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Cutting the existing leakage/broken CI pipe in position for upto 100mm bore and taking out the broken piece, with and including required excavation and earth work in any soil and fixing the new CI pipe and fittings with necessary joints complete all as dierected and shown by Engr-in-Charge. Note for srl item No. 45 & 46:- (a) CI pipe and fittings shall be measured & paid separately. (b) Lead/Tyton joints shall be measured & paid separately
Description all as per srl item No. 45 here in before but CI pipe of 150mm to 200mm dia complete all as specified and as directed.
S&F in repair 15mm bore ball valves high pressure of PTMTwith epoxy coated aluminium rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Description all as per srl item No. 47 here in before but 20mm bore ball valve complete all as specified and as directed.
Description all as per srl item No. 47 here in before but 25mm bore ball valve complete all as specified and as directed.
S&F in replacement 100mm bore CI sluice valve confirming to IS 14846 – 2000, PN 1.0, flanged ends, stainless steel spindle with necessary packing materials and nut, bolts complete all as specified and as directed.
Description all as per srl item No. 50 here in before but 150mm dia size sluice valve complete all as specified and as directed.
Description all as per srl item No. 50 here in before but 250mm dia size sluice valve complete all as specified and as directed.
M & L for scraping, cleaning thoroughly RCC under ground sump 3 lakh gallons capacity (in two compartments) scrapping all dirts, dust, rust from wall, roofs, side, bottom, inlet pipe, outlet pipes by clean water mixed with bleaching powder solution @ 0.5 Kg per Sqm including necessary arrangements for breathing for human being on job complete all as specified and as directed by Eng-In-Charge. Note:- The job includes for resetting of existing floats for smooth functioning.
Description all as per srl item No 53 but 3 lakh gallons capacity (in two compartments) complete all as specified and as directed by Eng-In-Charge. Note:- The job includes for resetting of existing floats for smooth functioning.
Description all as per srl item No 53 but 1.57 lakh gallons capacity (in two compartments) complete all as specified and as directed by Eng-In-Charge. Note:- The job includes for resetting of existing floats for smooth functioning.
M & L for scraping, cleaning of RCC over head water tanks at 50 feet staging 3 lakh gallons capacity (in two compartments) scrapping all dirts, dust, rust from wall, roofs, bottom side, inlet pipe, outlet pipes by clean water mixed with bleaching powder solution @ 0.5 Kg per Sqm including necessary arrangements for breathing for human being on job complete all as specified and as directed by Eng-In-Charge. Note:- The job includes for resetting of existing floats for smooth functioning.
Description all as per srl item No 56 here in before but of capacity 2/1.5 lakh gallons capacity in one compartment at Arty Bde area and 301 Bde area complete all as specified and as directed.
Description all as per srl item No 56 here in before but of cap 1.0/0.75 lakh gallon capacity in one compartment at Engr Regt area and KLP offrs qtr area complete all as specified and as directed.
Description all as per srl item No. 56 here in before but of cap 0.40/0.50/0.60 lakh gallon capacity in one compartment at different locations i.e Offrs Md Accn area, EME area, Div area, New pump house and 423 Fd Hospital area complete all as specified and as directed.
S & F in repair water level indicator painted with fluorescent paint/tape including GI wire of 6 mm dia (n. less than 20 m length) double pulley, wooden float duly completed of size not less than 300 mm dia covered with polyethylene film complete all as specified and as directed at site.
Repair/replacement of indicator board including replacement of damaged MS sheet of 1.6 mm thick painted with two coat of synthetic enamel black paint over one coat of red oxide primer including marking of scale in Ltr/Gallons with fluorescent paint /tape complete all as specified and as directed at site.
S & F in repair LED aviation lights luminaries integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 nos LED shall be provided, thick glass dome mounted on cast aluminium ring and complete with spring loaded high tension porcelain socket with neon spiral light sources 38 mm dia GI pipe entry and 19 mm dia cable gland complete fitted on OHT of any hight complete all as specified and as directed by Engrs-in-Charge. Make:- Bajaj, cat part No BGAV 302 LED.
M&L for writing letters as figures by using synthetic enamelled paint of white colour before making a rectangle of appropriate size (Block /Roman /Italic or Indian letter) of 15 cm high complete all as specified and as directed at site.
S & F in repair down conductor of aluminum strip of size 25 mm x 3.15mm thick fixed on RCC columns and tank, FRP insulator of height 32mm complete all as specified and as directed at site.
Cement concrete type C-2 1:3:6 (20mm graded aggregate) as per required at site and directed by Engineers-in-charge.
Rendering 10mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces
M&L brickwork with subclass B bricks, straight or curved on plan exc 6m mean radius built in CM (1:6)
M&L for gun painting by scraping with first enamell paint and one coat of grey colour painting to 10 HP pumps complete all as specified and directed
M&L for for servicing of filteration tanks with connected piping network and valves of Swimming pool by cleaning the gravel and re filling the same and necessary painting complete all as specified and directed by Engr-in charge
Supply and fix suction sweeper Nylon brush 36" long for Sweeper swimming pool for cleaner all as specified and directed bby Engr- in charge
Supply and fix suction sweeper wheel suitable for 36" long for Sweeper swimming pool for cleaner all as specified and directed bby Engr- in charge
M&L for Cleamning/ Washing mechanically fire Extinguisher capacity 132 ltr and making the good disturbed surface for re use the fire Extinguisher and re filling CO2 for fire Extinguishera after conducting Hydulic testing, painting and re installation all as shown and directed by Engr-in Charge Note: The above job inculdes replace the U/ spare parts
M&L for Cleamning/ Washing mechanically fire Extinguisher capacity 22 kg/ltrsr and making the good disturbed surface for re use the fire Extinguisher and re filling CO2 for fire Extinguishera after conducting Hydulic testing, painting and re installation all as shown and directed by Engr-in Charge Note: The above job inculdes replace the U/ spare parts
M/S Sweta Construction
Associated Engineers
M/S OMANIA ENTERPRISES
M/s Deepak kumar sinha
M/s Ray construction
m/s sheo kumar singh & sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .