Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | Admitted-Finance |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPL REPAIRS TO BLDG NO. 123-BD, 128-BD TOILET BLOCK OF BOYS SPORTS COY ARTY CENTRE, BER CEILING FANS, GEYSERS AND CERTAIN MINOR WORKS AT CERTAIN UNITS UNDER GE GOLCONDA
2022_MES_557458_1
8630/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹88,000
Yes
16 Nov 2022
13 Oct 2022
14 Nov 2022
13 Oct 2022
12 Nov 2022
27 Oct 2022
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation,etc or for shafts wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard/dense soil
Returnng, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and directed.
Spreading & Levelling and well ramming including watering as required in layers n.exc 25 cm thick
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for PCC 1:4:8 (using 40mm graded stone Aggregate) type D2 as in foundations, filling and mass concrete complete all as specified and directed.
M&L for walling of random rubble masonry Secunderabad pattern, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves including supports etc for rough finished surface of concrete complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
M&L cement concrete type B0 1:2:4 ( Using 12.5mm graded stone aggregate) as in Roof padding and benching & filletting mixed with IWPC (IWPC measured and paid seperately).
M & L Taking down existing roof treatment felt, plaster including preparation of the surfaces of roof by cleaning of foreign materials washing down with water, roughening surfaces of old concrete and washing down with water to remove dust, brushing neat cement slurry with 3 kg cement per square meter, applying screed 10mm thick on concrete surfaces in CM 1:4 and finished even and smooth without using extra cement mixed with water proofing compound including laying APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm) over primed surface with bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by torched application and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm finised with one coat of aluminium paint @ 100ml/Sqm, 10cm overlap fused uniformly by LPG torched flame, complete all as specified and directed. Note: 1) Water proofing compound will be measured and paid separately.
M&L for RCC type B1, 1:2:4 (using 20 mm graded stone aggregate) as in lintel bands, roof beams and cantilevers etc. complete all as specified and directed.
Use & waste of form work to chullah hoods, chajjas troughs and similor items including edges complete all as specified and directed.
M&L for RCC type B1, 1:2:4 (using 20 mm graded stone aggregate) mix for Chajjas complete all as specified and directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Ditto all as per item No. 19 above but 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders complete all as specified and directed.
M&L Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed.
M&L MS Plain plates, square cut, with riveted, bolted or welded attachment Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed.
M&L brick work with fly ash bricks built in CM 1:6 straight or curved on plan exc 6 mtr mean radius complete all as specified and directed.
M & L for half brick masonry for wall with fly ash bricks straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick wall/ stone wall, ceiling etc, raking out joints, hacking for key & scrubbing with water complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of concrete surfaces in ceilings with cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC over a coat of 10 mm thick ) on Brick wall surfaces, finished fair and even complete all as specified and directed. (IWPC measured separately)
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick over a coat of 10 mm thick) on fair faces of stone wall surface, even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick over a coat of 10 mm thick) on fair faces of brick wall surface, even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound
M & L three coats of white wash on newly plastered surfaces on wall including preparation complete all as specified and directed.
M&L Preparing of old plastered wall surfaces and applying One coat of white wash on walls complete and all as specified and directed.
M & L three coats of white wash on newly plastered surfaces on ceilling including preparation complete all as specified and directed.
M&L praparation of old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed.
M&L preparation of new plastered surfaces of walls and applying two coats of cement based paint over a Coat alkali resistant priming paint complete all as specified and directed.
M&L complete removal of existing treatment and praparation of Old plastered surfaces and applying two coat of Cement base paint on walls complete and all as specified and directed.
M&L hardcore of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface in broken stone or boulders complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick.(Below or above ground level).
Demolition floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M&L 25 mm thick PCC 1:2:4 Type Bo (usng 12.5mm graded stone aggregate) below floor finish for levelling of exixting surface complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but not exc 0.11 sqm as in floors laid over and including and cement screed in CM 1:6, 15mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick over backing coat in CM 1:4, 10mm thick and set and jointed in neat cement slurry and pointed in white cement to match complete all as specified and directed.
M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors including 15 mm thick screed bedding layer in CM 1:6 complete all as specified and directed.
M & L for 75 mm thick Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection finished even aned smooth without usisng extra cement complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) n.exc. 1.5 sqm complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening of brick wall complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
S&F for 100 mm long extruded Aluminium alloy butt hinges fixed to PVC door shutter.
S&F for 125mm long aluminium anodized barrel tower bolts of extruded section.
S&F for 125 mm long alluminium alloy anodized handles fabricated type
S&F wash down water closet (pedestal pattern) complete white with plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and flush pipe PVC 32mm dia for low level flushing cistern including trap and connection to drain (or outgoing pipe) complete all as specified and directed.
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110 dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed.
S & F PVC valveless, syphonic action type, flushing cistern 10 ltr capacity low level white with inlet, ball valve, float and handle including 32mm dia PVC flush pipe and brackets and necessary fittings complete all as specified and directed.
S & F in repair PVC valveless, syphonic action type, flushing cistern 10 ltr capacity low level white with inlet, ball valve, float and handle including 32mm dia PVC flush pipe and brackets and necessary fittings complete all as specified and directed.
S&F 15 mm size PVC connection 450mm long with PTMT nuts complete all as specified and directed.
S&F stop valve/angle cock 15mm bore cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure fixed to iron pipes or for unions complete all as specified and directed.
S&F concealed stop valve/angle cock 15mm bore, cast copper alloy, chromium plated, screwed down high pressure screwed both end for iron pipes or for unions and fixed complete all as specified and directed.
S&F fancy type bib tap 15 mm bore chromium plated, cast copper alloy , screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks triple layered (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I for capacity 1000 litre complete all as specified and directed.
S&F in repair PVC ball valve 25 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plasic ball screwed for iron pipe complete all as specified and directed (minimum weight 25 mm- 455 gms ).
S & F brass chromium plated tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges complete all as specified and directed.
S&F 125mm dia brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S&F GI pipes medium grade 15 mm dia with all fittings, fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F GI pipes medium grade 20 mm dia with all fittings, fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F GI pipes medium grade 25 mm dia with all fittings, fixed to walls, ceilings or laid in floors/trenches complete all as specified and directed.
Cutting existing steel tubing of size 50/40mm dia for alterations or additions (Each cut measured) complete all as specified and directed.
Screwing existing steel tubing of size 40/50mm dia for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and directed.
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface.
Taking out existing gunmetal globe or gate valve 20mm bore complete all as specified and directed.
S & F 20mm bore globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F 25mm bore globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F 40mm bore globe or gate valve with iron wheel head screwed both ends for iron pipe including taking out existing gate valve complete all as specified and directed.
S & F 110 mm PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 15 mm dia fancy type bib taps cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specifie and diredted.
S&F in repairs 15 mm dia Brass Stop valves/angle cock chromium plated fancy type, screwed down, high pressure, with crutch or butterfly hadle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F GI tube 15mm dia medium graded with all fitings, fixed to wall, celing or laying in trenches including taking up or down existing GI tubing with fittings complete all as specified and directed.
S&F GI tube 20mm dia medium graded with all fitings, fixed to wall, celing or laying in trenches including taking up or down existing GI tubing with fittings complete all as specified and directed.
S&F GI tube 40mm dia medium graded with all fitings, fixed to wall, celing or laying in trenches including taking up or down existing GI tubing with fittings complete all as specified and directed.
Construction of valve chamber of size 600x600x600mm with PCC 1:4:8 type D2 for foundation, brick wall in cement mortar (1:6), PCC 1:2:4 type B1 for coping, rendering in CM (1:4) 15mm thick for internal surfaces including coping concrete, cover made out of 3mm thick MS sheet fixed in angle iron frame of 40 x40 x 5mm welded to frame of angle iron of 40 x 40 x 5mm fixed in coping by hinges and applying two coats of synthetic enamel paint over a coat of redoxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed.
S&F 500 Ltr capacity rotaional moulded polyethylene water storage tanks triple layered cylindrical vertical with closed top hoisted and fixed in position including dismantling & removing existing HDPE tank complete all as specified and directed.
S&F in repair 40mm bore dia Gun metal Gate valve with iron wheel head screwed both ends for iron pipe or for union, complete all as specified and directed.
S & F PVC( SWR ) pipes 110mm dia single socketed, in any lenth with rubber ring joints as rainwater, soil waste and vent pipe fixed to wall or laid in trenches incl taking down existing pipe with fittings complete all as specified and directed.
S & F 110 mm PVC (SWR) junction single (Single T) equal or unequal with access Door complete all as specified and directed.
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 110mm complete all as specified and directed.
S & F 110 mm PVC (SWR) bends any radius complete all as specified and directed.
S & F in repair 110 mm PVC (SWR) bends with access door, any radius complete all as specified and directed.
S & F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall (with clamps etc) or laid in trenches or in floors including taking up or down existing pipe with fittings complete all as specified and directed.
S & F 110mm PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia, plain with gratings including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75mm dia, plain with gratings including jointing with solvent cement complete all as specified and directed.
S & F 75 mm PVC (SWR) bends any radius complete all as specified and directed.
S & F 75 mm PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 75mm complete all as specified and directed.
S&F PVC (SWR) junction double (double T) equal or unequal with access door of bore 75mm complete all as specified and directed.
M&L two coats of synthetic enamel paint to new steel surfaces over a coat of red oxide zinc chrome including preparation of surfaces, over 10cm width or girth not otherwise described complete all as specified and directed.
M & L preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L figured glass, pin headed type glazing with oil putty in squre n.exc. 0.5 Sqm in each pane, 3.00mm thick complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aparture 1.40 mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
S&F vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP pillar tap, 01 Nos 32mm waste coupling and pipe, one pair of MS bracket, cutting for and pinning in ends of brackets complete all as specified and directed.
S & F in vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S & F in repair vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) but exncluding waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair PVC waste pipe for urinal with all fittings etc, 38 mm dia. 60mm long complete all as specified and directed.
M&L CP steel Soap dish approximate size 100mm oval or any shape, fixed to plugs with chromium plated brass screws complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 150mm dia bore (Grade 'A') laid in trenches and jointed as specified complete all as specified and directed.
M&L for concrete bed to drain pipes 150mm dia using cement concrete 1:4:8 type D2 including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in Pre-cast cover slabs for mahnoles including necessary from work, set in CM 1:4 complete all as specified and directed. (Reincorcement shall be measured & paid separately)
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in benching/ Coping of manholes etc including necessary foam work , all as specefied .
INTERNAL ELECTRIFICATION M&L Point wiring for one light point/ fan point/ bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/ brick, masonary walls,roof etc including in sunk box of required size & 2 mm thick plastic laminated sheet for housing switches sockets, regulators etc, including making good the disturbed surfaces to match with the existing specification includind Taking out carefully copper/ aluminium point wiring, Light, fan, socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/ floors complete complete all as specified and directed
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated sheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for Concealed type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified and directed.
All as per item No.118 but One 5 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and directed.
Supply and fix Ceiling rose surface bakelite three 65x50 mm, terminals 240 volts complete all as specified and directed.
M&L switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/6 Amp flush type pin with porcelain base complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.
Supply and fix 10 watt LED Bulb, complete all as specified and directed.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete.
S&F Exhaust fan, steel body, AC single phase, 230V, 300mm sweep with blades and frames and louvers complete all as specified and directed.
S&F ceiling fan with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep minimum air delivery 210 CFM complete all as specified and directed.
Supply & Fix Ceiling fan Downrod of 4 ft length including nut, bolt on top side of down rod and taking down old unser one complete.
Supply & Fix Ceiling fan Downrod of 2 ft length including nut, bolt on top side of down rod and taking down old unserviceable one complete.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed.
Supply & Fix Flexible PVC hot & cold water connection pipe of length 0.45M complete all as specified and directed
S&F Sheet metal enclosure MCB DB including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fix Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 08 ways, complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SP and current carrying capacity 6- 32 AMP, in the MCB DB with connection testing and commissioning complete all as specified and directed.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and directed.
Supply, laying and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed.
Supply, laying and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection using fine river sand and provide required cover after punning down complete all as specified and directed. (Note:Punned thickness shall be measured and paid)
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
Supplying, installing, testing and commissioning in repair factory made outdoor type LT Kiosk box with canopy of size 1000mmx600mmx450mm with 4 nos 100 Amps aluminium busbar and 4 nos aluminium lugs of size 40mmx5mm of length 75 mm made out of 3.15mm thick CRCA sheet duly powder coated and locking arrangement including grouting in PCC 1:3:6 type C-1 complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
GNV Engg Services
NAVANAND ENTERPRISES
STANDARD AGENCIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .