| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹13.3 L+₹25,180.05 (1.93%)Rejected-Finance C O BIKASH CHAKRABORTY OPPOSITE GITAM NURSERY SCHOOL NEAR BAGHAJATIN PARK PO SILIGURI DISTT DARJEELING WEST BENGAL 734401 | DARJEELING | WEST BENGAL | 734401 | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹13.3 L+₹28,606.75 (2.19%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹13.4 L+₹32,045.15 (2.46%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹13.5 L+₹43,270.35 (3.32%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹11.9 L
EMD Value
₹24,000
Closing Date
6 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
COMPREHENSIVE MAINT/ REPAIR OF STANDBY POWER SUPPLY SYSTEM AND ALLIED WORKS UNDER AGE(I) DARJEELING
2021_MES_486859_2
CWE/136-WE/40 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E, Category b(i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Darjeeling
₹24,000
Yes
4 Feb 2022
13 Dec 2021
7 Jan 2022
13 Dec 2021
6 Jan 2022
23 Dec 2021
13 Dec 2021 - 17 Dec 2021
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/loose soil all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and including watering and consolidation to proper required cover all as specified and directed.
Supply and laying of old size sub-class ’B’ bricks laid flat equal to width of bricks, perpendicular to under groung cables over the dry sand cushioning, for cable protection all as specified and directed.
Dismantling/Taking out old unserviceable service connection cables / under groung cables, of any grade / type of size as below from pole/ wall/ cable duct/ under ground trench etc, all as specified as directed.
Supply and laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross-sectional area 95 Sqmm, 3.5 Core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed. (Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
Supply and laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross-sectional area 50 Sqmm, 3.5 Core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed. (Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
M&L for 50mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable all as specified and directed.
M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable all as specified and directed.
Supply & fix in Replacement street light fitting LED type 90 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit and GI Bracket etc and taking down old unsv any size/watt of security light all as specified and directed conforming to Cat No - ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO of Havells or equivalent model from make list in Tender Document.
M&L for cutting existing road/ hard standing not exc 20x30 cm in wide and depth getting out excavated material for laying cable/ GI tube, returning filling and well ramming watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as specified and directed.
INCOMING (c) MCCB 250 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed for incoming supply (Breaking capacity 36KA)Ics=100% of Icu-1 No. (MakeL&T,Cat part No-CM98403OOQOOG , or equivalent in Legrand/Havells)) OUT GOING (d) MCCB 160 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu-2 No. (MakeL&T,Cat part No-CM90642OONO , or equivalent in Legrand/Havells) (e) MCCB 100 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu-2 No. (MakeL&T,Cat part No-4CM90642OOLO , or equivalent in Legrand/Havells) (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by AGE(I) Darjeeling before panel fabrication).
M&L for 5000Gln capacity Mild steel tank surfaces shall be pre-treated by sand blasting or abrading with coarse emery paper to remove loose scale from the surface, cleaning with rust converter to remove rust from steel surface and dry the surface by using drier before application of hardener and resin, application of 3 layer CSM mat alongwith hardener and resin for making leakages sealed, after that one layer of surface mat to make the internal surface fully leakage proof, final layer with one coat of hardener, resin and one coat of Aqua Arm Tank Coat (non- toxic) complete all as specified and directed.
Supply and laying of 63 mm diameter(outer) 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in wall, floor and ceiling all as specified and directed.
Supply and fixing in repair On Load Changeover switch 200A ,4 pole in sheet metal enclosure complete all as specified and directed. Make: L&T, Cat No. CO22000OSOO or equivalent model from make M/s C&S Electric Ltd/ M/s Havells India Ltd/ ABB/ Siemens
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate No 3 of SSR part I including necessary excavation and earth work GI pipe 40mm dia light grade for watering and 15mm dia light grade GI pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to HT/LT poles/panel board as indicated including testing complete all as specified and directed.
Taking out centrifugal pump Only from foundation including opening with coupling from motor 5HP and transporting from pump house to Siliguri workshop for repair complete all as specified and directed.
Dismantling of 5 HP centrifugal pump of Make: Kirloskar opening, verifying, inspecting by Engineer- in- Charge and placement of existing damage parts and cleaning, reconditioning, polishing, cutting, machine work, Iboring alignment or shaft etc and reassembling of pump and spray painting including placement of all nut, bolts, washers and gaskets all as specified and directed. (Note- Spare parts shall be measure and paid separately under relevant item as supply only )
Supply only impeller for 5HP centrifugal pump all as specified and directed.
Supply only bearing for 5HP centrifugal pump all as specified and directed.
Supply only Shaft for 5 HP centrifugal pump all as specified and directed.
Supply only coupling for 5 Hp centrifugal pump all as specified and directed.
Transportation of Centrifugal Pump 5 HP from Siliguri work shop to Pump house and installation including testing etc. complete all as specified and directed.
Dismantling of 5 HP Motor and removing of burnt out winding cleaning including rewinding with all insulating materials, varnishing , heating, reassembling, painting including testing after completion incl transportation of 5 HP Motor from pump house to Siliguri workshop for repair complete all as specified and directed.
Transportation of 2HP Motor from Siliguri workshop to pump house and installation including testing complete all as specified and directed.
Taking out centrifugal pump set of capacity 2 HP form existing position for carrying out repair works and re-assembling, re-installing the pump set in original position complete all as specified and directed. (Note: The materials required for repair to centrifugal pump set shall be measured and paid separately under relevant items as supply only.)
Supply only impeller for 2HP centrifugal pump all as specified and directed.
Supply only bearing for 2HP centrifugal pump all as specified and directed.
Supply only Shaft for 2 HP centrifugal pump all as specified and directed.
Dismantling and opening the 2HP motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed.
Taking down Centrifugal Pump 75HP only from foundation, including opening with coupling room motor 75 HP and Repair the foundation with PCC 1:3:6 and including fixed with locking arrangement and re-installing the pump set in original position including testing complete all as specified and directed.
Taking down Centrifugal Pump 5HP only from foundation, including opening with coupling room motor 5HP and Repair the foundation with PCC 1:3:6 and including fixed with locking arrangement and re-installing the pump set in original position including testing.
Taking down Centrifugal Pump 2HP only from foundation, including opening with coupling room motor 2HP and Repair the foundation with PCC 1:3:6 and including fixed with locking arrangement and re-installing the pump set in original position including testing complete all as specified and directed.
Excavation in post holes in soft/loosesoil or similar holes each n exc 0.5 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and remaning surplus soil removing to a distance n exc 50cm and making good surface complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting and FRP sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, all as specified and directed.
M&L for preparing new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as directed and specified.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
M/S B D ENTERPRISE
GEETA CONSTRUCTION
BIMAL BHATTRAI
M/S S. S CHETTRI AND SONS
Damdoo Bhutia
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .