THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
OFFICE OF THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
Annual rate contract for Repairs and Maintenance of 33KV lines (District Srinagar) falling under the jurisdiction of Sub Transmission Division-II, Rajbagh, Srinagar for the year 2024-25 or till next rate contract
2024_PDD_249668_1
eNIT No. STD-II / 10 of 2024-25 Dated 07-06-2024
Open Tender
Electrical and Maintenance Works
Item Rate
1 days
SRINAGAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
₹30,000
3 Jul 2024
11 Jun 2024
2 Jul 2024
11 Jun 2024
1 Jul 2024
11 Jun 2024
Amount
Erection of 13 mtr Long ST Pole (ST-410SP-69) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard including transportation/carriage from Dvisional Stores to works site , loading unloading etc (material to be provided by deparment)
Erection of 11 mtr Long ST Pole (ST-410SP-56) with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard including transportation/carriage from Dvisional Stores to works site , loading unloading etc (material to be provided by deparment)
Dismantling of Wooden Pole of sizes, 13 /11mtr Long ST Pole (ST-410SP-69) along with allied accessories including loading at the site, transportation/carriage to divisional stores and unloading etc
Providing and Painting of 13mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Providing and Painting of 11mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
Providing and laying of Cement bottoming of 13mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard 0.7cum/pole) using 20mm crush stone aggregate including shuttering ,form work etc.
Providing and laying of Cement bottoming of 11mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard 0.6cum/pole) using 20mm crush stone aggregate including shuttering ,form work etc.
Providing and Fixing of Earthing complete with by GI Pipe 40mm 3m long through GI strip 25x8mm
Providing and Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8) mm, nutbolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete Nos
Dismantling of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete) including transportation/carriage to Dvisional Stores
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.1 ACSR
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.15ACSR
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.2 ACSR
Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor as per REC Construction standard including transportation/carriage from Dvisional Stores to works site , loading unloading etc (material to be provided by deparment)
Laying,stringing ,tensioning and binding of 0.15 ACSR Conductor as per REC Construction standard including transportation/carriage from Dvisional Stores to works site , loading unloading etc (material to be provided by deparment)
Laying,stringing ,tensioning and binding of 0.1 ACSR Conductor as per REC Construction standard including transportation/carriage from Dvisional Stores to works site , loading unloading etc (material to be provided by deparment)
Re-stringing of 0.2 ACSR Conductor including tensioning, binding etc
Re-stringing of 0.15 ACSR Conductorincluding tensioning, binding etc
Re-stringing of 0.1ACSR Conductorincluding tensioning, binding etc
Supply, installation,testing and commissioning of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm)
Providing and fixing of 33kV tension fitting heavy duty type of sizes
Supply,installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm )
Supply,installation,Testing and commissioning of 11kV Polymeric composite Pin Insulator (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm)
Providing and fixing of 11kV Polymeric composite Disc Insulator (12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm)
Providing and fixing of 11kV tension fitting heavy duty type of sizes
Providing and fixing of danger plates (6"X8"X4mm thick) with clamps as per REC standards
Providing and fixing of anti climbing devices with clamps as per REC standards
Providing and fixing of fabricated GI Channel / Angle Iron of sorts as per site requirement
Providing and Fixing of jumper sets (3 Nos) for 33KV line
Supply,erection,testing and commissioning of 33KV,400sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS as per latest IS
Supply,erection,testing and commissioning of 33KV,630sqmm Single core Aluminium, round wire Armoured XLPE Cable , FRLS as per latest IS
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 400sqmm Single core Aluminium, round wire armoured XLPE Cable as per latest IS
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 630sqmm Single core Aluminium, round wire armoured XLPE Cable as per latest IS
Providng and fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts
Providing and fixing of extension / risers of GI Angle Iron /Channel Iron
Supply, installation,testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA)
Supply, installation,testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor, 3 poles, 25 kA)
Extensive Branch cutting of trees coming in the coridor 33KV line including cutting of trees beneath the 33KV line and transportation of serviceable material t Divisional Stores including stacking etc and disposal of unservicable material.(complete job) (Vehicle to be Provided by the Department)
Felling trees of the grith (measured at height of 1mtr above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unservicable material.
Beyond 30cm girth upto and including 60cm girth
Beyond 60cm girth upto and including 120cm girth
Beyond 120cm girth upto and including 240cm girth
Above 240cm grith
Note: 1. The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off. 2.The material to be provided by the department shall have to be lifted from Divisional stores 3. The replaced/damaged/spared out material/equipment shall have to be transported to Divisional Stores
M/S IMPERIAL ELECTRICAL ENGINEERS
M/S AL HAYAT ELECTRICALS
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .