Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC Being valid tenderer | |
| 2 | L2₹6.6 L+₹1.1 L (18.9%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-AOC Being valid tenderer | |
| 3 | L3₹8.5 L+₹3.0 L (53.4%)Rejected-AOC | L3 | Rejected-AOC Being valid tenderer |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
20 Oct 2021, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
SPECIAL REPAIR REPLACEMENT OF EM FITTINGS AND FIXTURES INCLUDING WIRING AT BUILDING NO P2 AT SONEGAON NAGPUR
2021_MES_477672_1
8403/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon, Nagpur
₹19,200
Yes
30 Nov 2021
24 Sept 2021
25 Oct 2021
24 Sept 2021
20 Oct 2021
8 Oct 2021
24 Sept 2021 - 1 Oct 2021
Amount
M & L for taking down carefully copper/aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,switch socket, or power)complete fittings such as switches,ceiling rose,pendents,regulators,sockets etc complete all as specified and directed.
M & L for taking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB's/MCB SP/SPN/TPN complete all as specified and directed.
M & L for taking down old unserviceable tube light/cfl light/recessed mounted light or any type of light fittings complete all as specified and directed.
M & L for taking down old unserviceable Sub Main wiring any type any capacity including conduits from its location & making good of distrubed surfaces complete all as specified and directed.
M & L for taking down old unserviceable surface mounting fixed cable 3.5 core16/35/50/70 sq mm or any capacity including LT cable complete all as specified and directed.
M & L for taking down ceiling fan complete all as specified and directed.
M & L for taking down exhaust fan/ wall mounted fan complete all as specified and directed.
Material and labour for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall / floor and fixed on ceiling/roof etc, including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
(a) One light point controlled by one switch
(b) One ceiling Fan point controlled by one switch
(c) One Exhaust Fan point controlled by one switch
(d) One wall mounted Fan point controlled by one switch
(e) One three pin 5 Amps switch socket outlet on independent board
(f) One three pin 5 Amps switch socket outlet on same board
M & L for all as per item No.8 here in before but point wiring with 2.5 sqmm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 1.5 sq mm multistranded copper cable green colour for earth continuity conductor complete all as specified and directed.
Refixing of switch piano, flush type single pole,5 Amps, 240 Volts Ac retreived from Srl Item No 1 complete all as specified and directed.
S&F switch piano, flush type single pole,5 Amps, 240 Volts Ac complete all as specified and directed.
Refixing of ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC retrieved from item no 1 complete all as specified and directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed.
Refixing of switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete retrieved from item no 1 complete all as specified and directed.
S&F switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete all as specified and directed.
Refixing of switch socket combination 2 IN 1, 3 PIN,5 and 15 flush type universal ,240 Volts, complete retrived from item no 1 complete all as specified and directed.
S&F switch socket combination 2 IN 1, 3 PIN,5 and 15 flush type universal ,240 Volts, complete all as specified and directed.
Refixing of Tube light fitting /cfl/LED light fitting wall mounted or recessed mounted any type any make any capacity retrieved from item no 3 complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completere wired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable complete all as specified and directed. Make CGCta No-CCS-100-20-65-HL2-DP-NWH/Havells/philips/Bajaj.
Supply and fix wall mounted LED study light fittings capacity 3 watt fixed on wall with all accessories complete, all as specified and as directed. Make - Bajaj/Philips/CG/Havells/Orient
Refixing of cable any size any capacity upto 70sqmm fixed on wall/trench with clamps & saddle properly as directed by E-in-charge retrieved from item no 5 complete all as specified and directed.
Refixing of fan step regulator,120 W,220/230 V AC. retrieved from item no 1 complete all as specified and directed.
S & F Fan regulator stepped type electronic fan regulator flush type on the phenolic laminated sheet complete all as specified and directed.
Material and labour for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing conduit fixed on walls/ floors/ ceilings etc. alongwith one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note : Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length.
Material and labour for submain wiring complete with two runs of 10.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing conduit fixed on walls/ floors/ ceilings etc. alongwith one run of 10.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note : Two runs of 10.0sqmm multistranded cable and one run of 10.0sqmm cable as earth continuity conductor shall be considered as one unit length.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 4 way, 415 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Refixing of DB's including all existing isolator/ MCCB,s/ MCB,s safely retrieved from Item No 2 complete all as specified and directed.
Supply testing and commissioning and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection all as specified and as directed.
Supply, fix, connecting and testing MCB SPN, 40 Amps, 240/415 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing MCB TPN, 32 Amps, 240/415 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing MCB TPN, 63 Amps, 240/415 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Refixing of Exhaust fan any type any make any capacity with cleaning & painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler complete all as directed by E- in- charge after minor repairs retrived from item no 7 complete all as specified and directed.
Refixing of Ceiling fan retrived from item no 6 any type any make any capacity with cleaning & painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler complete and minor repair all as directed by E- in- charge after minor repairs complete all as specified and directed.
S & F Ceiling fans, complete with three blade, down rod, accessories 230 V , 1200 mm sweep, with squirrel cage induction motor complete all as specified and directed.
Refixing of wall mounted fan any type any make any capacity retrived from item no 7 with cleaning & painting of fan complete with synthetic enamel paint by spraying including filling cavities with filler complete and minor repair all as directed by E- in- charge after minor repairs complete all as specified and directed.
S& F wall mounting fan of 400mm sweep single phase 230V AC oscillating type ,variable speed, connecting the fan to ceiling rose including provision of flexible copper cable complete all as specified and directed.Make-: /CG model-SS torm2/Almonard/Havells
Paragon Electrotechnics
Chinmaya Enteprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .