Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.6 L+₹47,175 (3.90%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹13.5 L+₹1.4 L (11.4%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹15.0 L+₹2.9 L (23.8%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹16.8 L+₹4.7 L (38.4%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair/ maintenance of pumpsets motors, starters, LT panel boards, bulk water meter etc at water supply installations under GE (CME) Kirkee
2022_MES_540414_1
8343/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class E a(ii)
9 documents required · 9 mandatory
₹500
Garrison Engineer (CME) Kirkee
₹50,000
20 Sept 2022
26 Jul 2022
22 Aug 2022
26 Jul 2022
20 Aug 2022
7 Aug 2022
27 Jul 2022 - 6 Aug 2022
Amount
M&L for disconnecting and removing the PUMP SET from its foundations/ base frame located at different locations, by disconnecting suction, delivery pipes, pump couplers and electrical connections, taking it to workshop for repair, Dismantling and opening up of PUMP assembly complete, removing worn out Gland, bush, shafts, pump Housing, bearing, Gland Packing, Pin locking set, nuts and bolts, washers etc., and replacing with new parts of same make/model/type including necessary machining works as required, assembling, Balancing and refixing the pump back to its postion after getting repair and making all connections, carry out alignment, and testing for satisfactory function all as specified and as directed for following Pumps:-
Split type centrifugal Pump set of Make Kirloskar, Model No UP 150/38B, 1450 RPM coupled with 50 HP motor at Main Pump at House Bhosari
Centrifugal pumpset of make Kirloskar model No DB 40/20 coupled with 10 HP motor in MAP Pump House
Monoblock Centrifugal Pump Set Type: KDS 844++ Capacity 450LPM@ 38m Head coupled with 7.5HP motor
Split type centrifugal Pump set of Make Kirloskar, Model No DSM 50/28. (SS No 1)
Monoblock Centrifugal Pump Set of any capacity but coupled with electric motor upto and including 5 HP
All as per Item No. 1 above, but for open well type submersible pump set of any capacity coupled with electric motor 5 HP to 10 HP all as specified and as directed.
All as per Item No.1 above, but non clog submerible sewage non clog pump of following capacities by taking up/down from sewage sump including taking up/down suction & delivery pipes & connections and refixing all as speciifed and as direted by Engineer In Charge
Model No KDV, 312V, 365 Capacity: 10Cum/Hr @ 15m Head coupled with 5HP three phase electric motor Make: Kirloskar (MAP Ph I sewage pump house)
Dismantling and taking out unserviceable Dry Motor submersible sewage pump set having flow : 800m3/hr, 15 mtr head self cooling jacket system and solid handling capacity 100mm installed at STP Kasarwadi of capacity 70HP, Make Kishor Pumps, Model ASTRA SA 250-315 with the following work services:- a) Disconnecting water and electric connections, shifting the pump from Pump house to workshop (to and fro) for carry out necessary repair. b) Opening the pump completely part by part without damaging any parts, descaling and cleaning of all parts for inspection and finding serviceability / unserviceability of the parts. c) Repair and assembling of pumps by using existing serviceable parts and replacement of unserviceable parts as directed including necessary machining works required for proper setting and smooth functioning to achieve desired discharge of the pump. d) Rewinding of built in dry submersible motor 3 phase , 415 volts, 50 Hz of 70 HP capacity by using PVC insulated supper enamelled copper winding wire as per existing gauge as per manufactures specifications and direction ,heating, varnishing complete. The repair work consisting of thoroughly cleaning of slots, removing all dirt , grease and other unwanted particle, reassembling the complete motor after repairs and reinstall in pump set including connecting. e) Reinstall the pump at its existing foundation, making electric and water connections, finally testing the pump set for its trouble free functioning complete. Note : (i) Spare parts required for replacement shall be measured and paid seperately under appropriate items as supply only. (ii) Any Machining works required for balancing of inpeller /for fixing of new parts with existing shafts is deem to be included with the unit rate. No extra amount on this account shall be entertained seperately. iii) Any minor parts (Total cost less than Rs. 200/-) which are not covered under this schedule but inescapable requirement for repair shall also be deem to be included with the unit rate quoted. No extra on this account shall be entertained by the Department. However any dispute GE's discussion in this regards shall be final & bindings.
Supply only following parts of Dry Motor submersible sewage pump set, Model ASTRA SA 250-315 Kishor pump of capacity 70 HP to incorporate under item No. 4 above (as per site requirement) for satisfactory repair of the pumps.
Impeller for Model ASTRA SA 250-315
Double mechanical seal (Internal & External) for Model ASTRA SA 250-315
Mechanical seal cover for Model ASTRA SA 250-315
upper bearing for Model ASTRA SA 250-315
lower bearing for Model ASTRA SA 250-315
cable gland for Model ASTRA SA 250-315
Cable seal for Model ASTRA SA 250-315
Stuffing box bush for Model ASTRA SA 250-315
Bearing grease for Model ASTRA SA 250-315
Hose clip for Model ASTRA SA 250-315
Oil seal for Model ASTRA SA 250-315
lower Bearing housing for Model ASTRA SA 250-315
Impeller screw for Model ASTRA SA 250-315
Material and Labour for disconnecting and removing the MOTOR of any make/model / type, from pump sets and foundations/ base frame located at different pump houses, by disconnecting electrical connections and pump couplers, taking it to workshop for repair, dismantling stator and rotor assembly, removing burnt out winding wires complete, rewinding the stator with same guage and type of insulation copper conductor winding wires and insulation sheets, applying insulating varnish over the complete winding, drying up by heating, assembling back the stator and rotor including replacement of nuts, bolts, studs, Gasket, packing, locking pin, terminal blocks, and terminal bolts and nuts and misc accessories & hardware required for making motor functional, both end bearings (labour only) with same size/make complete for following motors all as specified and as directed :- Note: 1. Bearing shall be measured and paid saperately.
Single Phase, 240V Motor of capacity upto 2 HP
Three Phase, 415V Motor of Capacity 5 HP
Three Phase, 415V Motor of capacity 7.5 HP
Three Phase, 415V Motor of capacity 10 HP
Three Phase, 415V Motor of capacity 12.5 HP
Three Phase, 415V Motor of capacity 50 HP
M& L for removing bore well column pipes upto 80mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY, shifting to workshop and removing unserviceable spares, replacing with new spares such as impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets, applying insulating varnish over the complete winding, drying up by heating, assembling back and testing for proper function including necessary machining works as required, bringing back and reinstalling into the bore well all as specified and as directed. Note: 1. Bearing shall be measured and paid saperately.
Open well submersible pump capacity 5 HP, AC 3 Phase, 50 HZ.
Open well submersible pump capacity 10 HP, AC 3 Phase, 50 HZ.
Open well submersible pump capacity 12.5 HP, AC 3 Phase, 50 HZ.
M& L for removing Non clog submersible pump set with submersible flat cable of any type and dismantling and taking up/down Non clog submersible pump set, shifting to workshop and removing unserviceable spares, replacing with new spares such as impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling into the bore well all as specified and as directed. Note: 1. Bearing shall be measured and paid saperately.
Non clog submersible sewage Pumpset capacity 5 HP, AC 3 Phase, 50 HZ
Supply and fix Pump shaft made of stainless steel for Kirloskar make pumpset of following models:-
Split type centrifugal Pump set of Make Kirloskar, Model No UP 150/38B, 1450 RPM coupled with 50 HP motor.
Centrifugal Pump set of Make Kirloskar, Model No DSM 50/28 coupled with 12.5 HP motor.
Monoblock centrifugal pumpset of make Kirloskar model No DB 40/20 coupled with 10 HP motor
Supply only tyre coupling suitable for centrifugal pumpset coupled with 50 HP motor along with flanges, nuts, bolts, washers, etc incluiding all cutting key and to suit shaft of pumpset and motors all as directed by Engr-in-charge.
All as per item No.10 above, but for 10HP
All as per item No.10 above, but for 12.5 HP
Supply only nylon rope of 20mm dia for bore well pump
Supply & fix Mild Steel bore well cap suitable for bore size upto 250mm
Supply only antifriction heavy duty ball bearings 6305 Make: SKF
Supply only antifriction heavy duty ball bearings 6306 Make: SKF
Supply only antifriction heavy duty ball bearings 6307 Make: SKF
Supply only antifriction heavy duty ball bearings 6308 Make: SKF
Supply only antifriction heavy duty ball bearings 6309 Make: SKF
Supply only antifriction heavy duty ball bearings 6312 Make: SKF
Supply only antifriction heavy duty ball bearings 6313 Make: SKF
Supply only antifriction heavy duty ball bearings 6203 Make: SKF
Supply only antifriction heavy duty ball bearings 6212 Make: SKF
Supply and install CI foot valve of size 250mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install CI foot valve of size 200mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install CI foot valve of size 150mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install CI foot valve of size 100mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install CI foot valve of size 80mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install CI foot valve of size 50mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
Supply and install fully automatic Starter Star Delta type with single phase protection feature suitable for operation on AC, Three phase four wire, 415 Volts, 50 Hz supply for Motor of capacity 15HP with relay range 9-15Amps complete Cat No SS94362 Make: L&T or equivalent in SIEMENS/HAVELLS with taking down old u/s starter of any type
Supply and install DOL starter type MN in sheet steel enclosure suitable for AC, Three phase, 415 Volts, 50 Hz supply and Motor capacity 10HP with relay range 9-15Amps complete Cat No SS94351 Make: L&T or equivalent in SIEMENS/HAVELLS with taking down old u/s starter of any type
Supply and install fully automatic Starter Star Delta type with single phase protection feature suitable for operation on AC, Three phase four wire, 415 Volts, 50 Hz supply for Motor of capacity 50 HP with relay range 30-50 Amps complete Cat No SS94021 Make: L&T or equivalent in SIEMENS/HAVELLS with taking down old u/s starter of any type
M & L for repair of u/s Electromagnetic water flow meter (EMF) ISO: 4064,Accuracy +0.5%, Make – Endress + Hauser, Model No - 10L4H-U-20A-1AN4B4AA installed at STP kasarwadi incl Transportation to & fro workshop and replacement of u/s spares for meter. Installation and testing of repaired meter on same location all as specified and as direted by Engineer In Charge.
Supply and install DOL starter type MK-1 in sheet steel enclosure suitable for AC, Three phase, 415 Volts, 50 Hz supply and Motor capacity up to 7.5HP with relay range 11-18Amps complete Cat No SS96211 Make: L&T or equivalent in SIEMENS/HAVELLS with taking down old u/s starter of any type
Supply and fixing of combination coil for MK-1 DOL starter for 400/440V, 50 Hz all as specified and directed.
Supply and install submersible pump controller in sheet enclosure type MU-G for 415V, 3Ph electric submersible motor of capacity 6Hp. Cat No SS97756 Make: L&T or equivalent in Siemens/Havells with taking down old u/s pump controller of any type
All as per item No.36 above, but for motor capacity 10 HP Cat No SS95983 Make: L&T or equivalent in Siemens/Havells
All as per item No.36 above, but for motor capacity 12.5 HP cat No CS94091 Make: L&T or equivalent in Siemens/Havells
All as per item No.36 above, but for motor capacity 70 HP cat No CS96451 Make: L&T or equivalent in Siemens/Havells
S & F in replacement Power Contactor 3-Pole with AC Coil 50 Amps along with Aux. Contacts 02NO & 02NC for 3 phase star delta starter AC 440 volts 50Hz MNX 32 Make : L&T Cat No.: CS94111 or equivalent make as approved in the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and as directed.
All as per item No.40 above, but MNX 25 with aux contacts 01NO & 01NC Cat No CS94110 Make : L&T or equivalent in Siemens/Havells
All as per item No.40 above, but MNX 22 with aux contacts 01NO & 01NC Cat No CS94980 and CS94981 Make : L&T or equivalent in Siemens/Havells
All as per item No.40 above, but MNX 12 with aux contacts 01NO & 01NC Cat No CS94108 and CS94109 Make : L&T or equivalent in Siemens/Havells
Supply and fixing Air circuit breaker manually operated drawout type of 800A, 500V, 3pole, 50kA, MDO version microprocessor based SR18G, C power S1 with standard accessories on provided iron frame Cat No: SL96042 Make: L&T or or equivalent in Siemens/Havells
S & F Thermal overload relay range 3 to 5 Amps including taking down the old relay including material for wiring if required complete all as specified and directed MN2 Cat No SS94141OOSO Make : L&T or equivalent in Siemens/Havells
S & F Thermal overload relay range 6 to 10 Amps including taking down the old relay including material for wiring if required complete all as specified and directed MN2 Cat NoSS94142OOVO Make : L&T or equivalent in Siemens/Havells
S & F Thermal overload relay range 9 to 15 Amps including taking down the old relay including material for wiring if required complete all as specified and directed MN2 Cat No SS94142OOBO Make : L&T or equivalent in Siemens/Havells
S & F Thermal overload relay range 20 to 33 Amps including taking down the old relay including material for wiring if required complete all as specified and directed. MN2 Cat No SS94145OOEO Make : L&T or equivalent in Siemens/Havells
S & F Thermal overload relay range 30 to 50 Amps including taking down the old relay including material for wiring if required complete all as specified and directed type MN5 Cat No SS94136OOGO Make : L&T or equivalent in Siemens/Havells
S & F electronic timer for 3 phase starters including wiring materials and taking down old unserviceable timer complete all as specified and directed. cat part no ST80329OOOO Make : L&T or equivalent in Siemens/Havells
S & F in replacement DIN Type Fuse 200 A suitable for HRC fuse kit Cat No. SF 94232 Make: L&T/Siemens/Havells
S&F in replacement HRC fuse base type HN size 2 & 3 for capacity 300 A as per existing make and specifications all as specified and directed.
S & F in replacement Single Phase preventor relay SPPR type Sz5 (6 Wire), 415V, cat No. CS94824DOOO. Make : L&T or equivalent in Siemens/Havells
S & F in replacement Single Phase preventor relay SPPR type SDz5, 415V, cat No. XM81807OOOO. Make : L&T or equivalent in Siemens/Havells
S&F in replacement HRC fuse base for capacity 80-250 A. Cat No SK90406. Make: L&T or equivalent.
S & F illuminated Push Button Projecting Head complete all as specified and directed in RED/GREEN in color, 240V AC, Cat No EG03PDL, Make: L&T/HPL with taking down old u/s push button of any type
S & F LED Indication lamp for LT Panel board RED/YELLOW/BLUE, Surface Mounted Device LED technology Low Power consumption < 0.6W Low Voltage Glow Protection (LVGP) Cat No: SIL 240A-240V AC. Make: L&T or HPL/Havells
Supply, laying, connecting and testing Submersible flat cable 3 core 2.5 Sqmm PVC insulated and PVC sheathed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply, laying, connecting and testing Submersible flat cable 3 core 6 Sqmm PVC insulated and PVC sheathed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply, laying, connecting and testing Submersible flat cable 3 core 10 Sqmm PVC insulated and PVC sheathed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply, laying, connecting and testing Submersible flat cable 4 core 16 Sqmm PVC insulated and PVC sheathed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply and Fix 415V, 50Hz, four pole MCCB 400A, 50KA, Cat No ISLLNFBF0400. Make: Standard/L&T/Havells with taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
Supply and fix 3 pole MCCB of 250A capacity with S.C. rating of 35kA,thermal and magnetic setting with provided leads on iron frame/lamination board as per existing make and specifications all as specified and directed.
Supply and fix cam operated rotary switches 32A with 90⁰ ON-OFF operation and complete rotation of type . Cat No.61197 of Make: L&T or equivalent of Siemens/Standard
S & F in replacement Power Contactor 3-Pole with AC Coil 160 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz MNX 140 Make : L&T Cat No.: CS94138 or equivalent make as approved in the existing panel, connecting up and testing including material for wiring if required as specified and as directed.
Supply and Fix 3 pole MCCB 100A capacity with S.C. rating of 50kA,415V, 50Hz, thermal and magnetic setting with provided leads on iron frame/lamination board, Type DN0-100M Cat No CM98944OOKO Make: L&T or equivalent of Standard/Havells/HPL/Indoasain with taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
S & F in replacement Power Contactor 3-Pole with AC Coil 300 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz, MNX 250 Make : L&T Cat No.: CS94141 or equivalent make as approved in the existing panel, connecting up and testing including material for wiring if required as specified and as directed.
S & F in replacement Power Contactor 3-Pole with AC Coil 160 Amps along with Aux. Contacts 02NO & 02NC,440 volts 50Hz MNX 110 Make : L&T Cat No.: CS94137 or equivalent make as approved in the existing panel, connecting up and testing including material for wiring if required as specified and as directed.
S& F Non retrun valve (NRV) without by pass arrangement including provision of jointing material such as insertion sheet 3mm thick, nut & bolts all as required at site 80mm dia bore ISI marked complete with rubber gasket all as specified and directed.
S& F Non retrun valve (NRV) without by pass arrangement including provision of jointing material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as specified and directed.
S& F Sluice Valve Class PN 1.6 without by pass arrangement including provision of jointing material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as specified and directed.
M&L for Painting of pump sets & motor assembly of capacity 5 HP to 15 HP located at various installations comprising electric Motor, pump, base frame, suction and delivery pipe lines inside & outside of pump house, valves any type and size up to 100 mm dia with two coats of synthetic enamel paint of approved colour including scrubbing / cleaning all metalic surfaces before painting and writing SM/MES No. etc, all as specified and directed :-
All as per Item No. 74 above, but for pump Motor of capacity 20 HP to 50 HP and pipe size upto 350 mm dia
Supply and fix suction and discharge flexible hoses with specially compounded PVC reinforcement, helically wounded and inseparably fused to the soft inner walls suitable for withstanding multi-axial stress and pressure 10Kgf/Sqcm of dia 40mm all as specified and directed.
M & L suction and discharge flexible hoses with specially compounded PVC reinforcement, helically wounded and inseparably fused to the soft inner walls suitable for withstanding multi-axial stress and pressure 10Kgf/Sqcm of dia 50mm all as specified and directed.
M & L suction and discharge flexible hoses with specially compounded PVC reinforcement, helically wounded and inseparably fused to the soft inner walls suitable for withstanding multi-axial stress and pressure 10Kgf/Sqcm of dia 80mm all as specified and directed.
Trimming of tree exc. 30 cm girth and n.exc 100cm girth including cutting of trunk, and branches and disposal of unserviceable material to a distance n. exc. 50 m and clearing site all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for foundation of pump set & Motor including plastering in CM 1:4 all as specified and directed.
M & L for carry out water quality anyalysis for bacterial, chemical and biological analysis including for collection of water samples from the pump house and one of the location as specified by Engineer In Charge and testing from govt approved testing laboratory/FHHL lab, submitting of reprort for minimum following parameters (a) Turbudity (NTU) (b) pH (c) Total Hardness as CaCO2 (mg/l) (d) Sulphate as SO2 (mg/l) (e) Iron as Fe (mg/l) (f) Magnesium as Mg (mg/l) (g) E-Coli or thermotolerant coliform bacteria (h) Remarks of Govt water testing lab
Material & labour for Earthing complete using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire of 4mm dia by means of bolts, nuts, check nuts and washers and protected by light grade 15 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No.3 of SSR Part-I for different capacities pumpsets.
The unit rate shall include GI protection pipe 15mm dia 7.5Mtr, GI water pipe 20mm dia, wire mesh, funnel, excavation, RCC pit cover, P.C.C chamber pit,. test point, Main earthing lead from earth electrode to test point upto 7.5 metre and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.
PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junction etc shall be deemed to be included in the unit rate.
CI pit cover or precast RCC 1:2:4, type B-1, 80mm thick reinforced with XPM (weighing not less than 4 Kg/sqm in lieu of cast iron cover).
Material & labour for Earthing complete using copper earth plate electrode of size 60cm X 60cm X 3.15mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20X3 mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.
M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc all as specified and directed.
S&F earth continuity conductor or main earthing lead of size 20x3 mm copper strip fixed to wall with S&F of porcelain /PVC insulator burried ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-Charge
Supply and replacement of chloroscope kit upto 2ppm housed with wooden box all as specified and directed by Engineer In Charge
M & L for Framed work such as grills, gratings, bar, flat plates etc. conforming to Fe.290.Gde-E-165 with two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer including preparation of new steel surface incl taking down old unserviceable one all as directed and specified by Engineer In Charge
M & L for cleaning of strainer 400mm dia including opening of strainer top cover by removing nut/bolts, removal of strainer screen and taking out dirt, mud, foreign particles accumulated inside strainer, assembling back and replacemnt of worn out nut bolts and gasket all as specified and directed by Engineer In Charge
M & L for repair of u/s water meter 400mm dia incl Transportation to & fro workshop and replacement of u/s spares for water meter like worn out gear assembly, impeller, spindle, nut bolts, washers, rubber gaskets, packing set including Calibration & testing at MIDC laboratory Mumbai as per MIDC norms. Installation of repaired water meter of 400mm dia including taking down existing water meter, replacement of rubber gasket, nut bolts, cleaning and removing accumulated mud, dirt and foreign material from strainer assembly. provision of strainer screen made up of perforated steel sheet all as specified and as direted by Engineer In Charge Note: Calibaration Certificate from MIDC Lab shall be produced by the contractor before payment
Supply and fix Shock treatment chart in different languages (English, Hindi, Marathi) coloured with size not less than 600x900mm duly framed in transparent glass complete all as specified and directed by GE with taking down old chart
Supply and fix fire fighting chart in different languages (English, Hindi, Marathi) coloured with size not less than 600x900mm duly framed in transparent glass complete all as specified and directed by GE with taking down old chart
M/S kirpan Enterprises
metro electrical services
SKS Electricals
Sachin Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .