| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | ₹48.3 L Quoted ₹48.9 L | L1 | Accepted-AOC Awarded as first lowest bidder (L1) |
| 2 | L2₹50.1 L+₹1.2 L (2.45%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹50.1 L+₹1.2 L (2.45%) | L2 | Rejected-AOC Being second lowest bidder |
| 3 | L3₹51.1 L+₹2.2 L (4.48%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | ₹51.1 L+₹2.2 L (4.48%) | L3 | Rejected-AOC Being third lowest bidder |
| 4 | L4₹51.3 L+₹2.4 L (5.01%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹51.3 L+₹2.4 L (5.01%) | L4 | Rejected-AOC Being forth lowest bidder |
| 5 | L5₹51.9 L+₹3.0 L (6.09%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹51.9 L+₹3.0 L (6.09%) | L5 | Rejected-AOC Being fifth lowest bidder |
Tender Value
Refer Docs
EMD Value
₹98,700
Closing Date
19 Nov 2022, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
SPECIAL REPAIR REPALCEMENT OF HT BREAKERS APFC PANEL AGAINST BER WITH VCBs 22 KV NEW APFC PANEL AND OTHER CONNECTED WORK AT NMRL
2022_MES_554174_2
GERD/PSN/TOKEN/29 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹98,700
Yes
22 Dec 2022
5 Nov 2022
22 Nov 2022
5 Nov 2022
19 Nov 2022
12 Nov 2022
5 Nov 2022 - 11 Nov 2022
Amount
Dismantling/ Taking down 05 Nos existing HT breakers from old 22 KV sub station technical area NMRL Ambernath including removal of all HT connection from breakers/ transformers with saftey and depositing to all HT breakers and other connected assessories to MES store by transport with required manpower complete all as specified and directed by Engr-in-Charge.
Dismantling/ Taking down 01 Nos existing APFC panel from old 22 KV sub station technical area NMRL Ambernath including removal of all electrical connection from breakers with saftey and depositing breaker and other connected assessories to MES store by transport with required manpower complete all as specified and directed by Engr-in-Charge.
Dismantling/ Taking down existing Battery bank with charger at old 22 KV sub station technical area NMRL Ambernath including removal of all electrically connection from breakers with saftey and depositing breaker and other connected assessories to MES store by transport with required manpower complete all as specified and directed by Engr-in-Charge.
Demolition of Concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for PCC in 1:2:4 type B 1 by using 40 mm graded crushed stone aggregate for making good road/foot path/hard standing/drain/ bldg plinth protection complete all as specified and directed by Engr-in-Charge.
Supply, install, testing and comprissioning of indoor APFC panel factory made 150 KVAR, 6 steps (3x50) auto charging switching, indoor, bottom cable entry floor mounted with hevy duty MPP capacitor non compartmentalised, suitable APFC relay. The panel shall be made up of CRCA steel sheet, 2 mm thickness, powder coated as per RAL 7032 with suitable size MCCB 4 pole 400 Amps, CTs, digital meters, phase indicating lamp, suitable aluminium bus bar with support, cooling fan, O/L and S/C protection, suitable rated relay, etc with following specifications:- (Make : Schneider/ L&T/ Siemens/ ABB/ Havells) (a) Type of capacitors= super heavy duty square type of 415Volt. (b) MCCB, 4 pole, 36KA adjustable type with O/L and S/C protection of 250 Amp = 01 Nos as incoming Make : (Make : Schneider/ L&T/ Siemens/ ABB/ Havells) (c) Phase indicating lamp =01 set (d) Digital VAF meter=01 set (e) APFC relay=01 set (f) CTs 300/5 Amp, CI 1.0, 10 VA=03 Nos (g) Sensing of suitable capacity with control cable shall be provided by the contractor.
Material and labour for special factory made earthing electrode comprising of Hot dipped galvanized MS flat inserted in to GI pipe of 82 mm bore (outer), 3metre length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of of 150mm dia in any type of strata connecting to test point including excavation /earth work in any starta PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even surfaces, RCC 1:2:4 type B0 precase chamber cover slab with GI strip 32mm x 6 mm upto 7.5m complete all as specified and directed by Engr-in-Charge. Connecting to test point complete all as specified and directed (the earth resistance shall be less than 3 Ohms). Contractor shall improve the earthing resistance within the permissible limit without any extra cost. Make : TRUE POWER, FAST ELECTRODE, ASHLOK
Material and labour for indoor type end termination touch proof joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 185 sqmm, 22 KV complete all as specified and directed by Engr-in-charge. Make : 3M, RAYCHEM or techno commerical equivalent
Supply, installing, testing and commissioning, factory made and tested, CPRI Approved LT panel board indoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 1.5 mm thick stainless steel grade 304 sheet size not more than (2700x2400x800)mm with suitable angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, compartmentalised independent chambers to accommodate ACBs, Bus couplers, MFM, MCCBs, MCBs with Contactors, Voltmeters, Ammeters and supply and fixing Relays, Indication lamps, Contactor, MCBs/fuses, Multifunction Meter - 01, LED RYB Indication lamps complete including bus bar chamber with electrolytic aluminium bus bar suitable for 2400 amps capacity for 3 phase and neutral (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrinked insulating sleeves and multifunction meter complete with wiring suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. Note 1: The LT panel shall be suitable for the fixing of the following ACBs, MCCBs, MCBs:- ACB 1600A - 02 (Transformer Incommer), MCCB 630A - 02 (DG Set-1, DG Set - 01 & 02 Incommer), MCCB 400 A (DG- 02 Incommer), MCCB 400A-06 (Out going), MCCB 630A - 06 (Out going), MCCB 250A - 06 (outgoing) Note2: The Rates are not included for ACBs, MCCBs, MCBs for which shall be paid separately under respective shedule of item. Note 3 : Rate for any addition and alteration required at the time of installation to connect bus duct with LT Panel shall deemed to be included in quoted rate. Approval for manufacturing of LT Panel should be taken from Engineer-in-Charge before ordering the Manufacture of LT Panel.
Taking down old unserviceable LT Panel with MCCBs, ACBs, MCBs, Contactors, Relays, Aluminium Busbars, Switch fuse units, Voltmeter, Ammeters, Multi Function Meters, Iron Scrap any type, size and make and kept aside for credit schedule complete all as specified and directed.
Supply and fixing ACB 4 Pole, 415 V, Manual Drawout type with Thermal magnetic release of capacity 1600 Amps with the specifications comprising of Current Metering (MTX1.5G/1.5Gi/3.5/ 3.5EC/3.5H/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Smart-racking shutter, Safety shutter assembly, Racking Handle, Door sealing frame, Pad-locking arrangement for ON/OFF button, Rating Error Preventer, Arc shield complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
Supply and fixing MCCB 3 Pole, 415 V, with Thermal magnetic release 160 Amps with breaking capacity 36 KA including spreader links and rotary handle complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
Supply and fixing MCCB 3 Pole, 415 V, with Thermal magnetic release 250 Amps with breaking capacity 36 KA including spreader links and rotary handle complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
Supply and fixing MCCB 3 Pole, 415 V, with Thermal magnetic release 400 Amps with breaking capacity 36 KA including spreader links and rotary handle complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
Supply and fixing MCCB 3 Pole, 415 V, with Thermal magnetic release 630 Amps with breaking capacity 50 KA including spreader links and rotary handle complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of Triple Pole and Neutral and current carrying capacity 40 to 100 Amps in the Panel complete with connection testing and commissioning complete all as specified and directed. Make: L&T/ C&S/ Siemens/ Legrand
cooltech engineering services
SKS Electricals
shakti engineering and electrical works
Shree Ayyappa Engineering
Borole Electricals
MAYUR ELECTRIC SERVICES
Star Electrical
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .