Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.8 LAccepted-AOC AT SANTIA PO JALESWAR PS JALESWAR DIST BALESHWAR | JALESWAR | BALESHWAR | ODISHA | ₹23.8 L Quoted ₹20.2 L | L-1 | Accepted-AOC ACCEPTED |
| 2 | L-1₹20.2 LRejected-AOC AT JIRITAL PO JIRITAL PS KHANTAPADA DIST BALESHWAR | JIRITAL | BALESHWAR | ODISHA | ₹20.2 L | L-1 | Rejected-AOC REJECTED |
| 3 | L-1₹20.2 LRejected-AOC AT NILAPURA PO KAMARDA DIST BALASORE ODISHA | BALANGIR | ODISHA | 767016 | ₹20.2 L | L-1 | Rejected-AOC REJECTED |
Tender Value
₹23.7 L
EMD Value
₹23,746
Closing Date
29 Nov 2025, 5:00 pmClosed
EE LI DIVISION ,JALESWAR
EE LI DIVISION ,JALESWAR
ARUHABRUTI-VII-RL
2025_OLIC_121352_64
04/2025-26/OLIC(JLS)
Open Tender
Civil Works - Lift Irrigation Schemes
90 days
JALESWAR, BALASORE
AS PER MENTION IN DTCN
3 documents required · 3 mandatory
₹7,080
₹23,746
Yes
15 Apr 2026
18 Nov 2025
1 Dec 2025
18 Nov 2025
29 Nov 2025
18 Nov 2025
18 Nov 2025 - 26 Nov 2025
Earthwork in excavation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge.
Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge.
Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.
Earthwork in excavation of foundation in hard soil for laying of HDPE Pipe Such as stiff clay , stiff black cotton, hard red earth, shales, moorum ordinary gravels, including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge. (Mechanical 60% & Manual 40%)
Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.
Brick work with Fly ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in superstructure per cum etc. complete as per the Engineer-incharge.
12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
2.5 cm A.S. Flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
Rigid smooths centering and shuttering for RCC works including false work and dismentgalling then after casting including cot os materials complete.a) Chajja/Roof slab
B)Lintel
C)RCC Beams, culumns, grider & Bressers etc
Dry brick rammed Khoa (10 cm) thick well watered and rammed inluding all cost as per specification in complete.
Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500)
Filling the foundation and plinth with excavated material as directed by the Engineer-incharge.
Filling the foundation and plinth in trench of HDPE Pipe with the excavated material as directed by the Engineer-incharge. (Mechanical 60% & Manual 40%)
White washing 3 coat with approve good shell lime including cost conveyance charges of materials including supply of labour, gum, indigo etc. required for the work complete as directed by the Engineer-incharge.
Cement punning over plastering
Finishing wall with water proofing cement paint of approved shade two coats to NEW work to give an even shade including cost of cement paints. etc. complete as per the direction of Engineer – in Charge.
Labour for fitting and fixing for door and window etc. complete as per the direction of the Engineer-incharge.
Priming 1 coat with any appproved Primer
Painting two coats with approved paint on new work
Cost of grill for window
Cost of Iron shutter for door
Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
Labour charges for excavation of bore holed pile foundation of 250 mm dia 2.50 mtr depth.
Cost of Wiring of Pump Chamber
Cost of River Bank cutting & shaping for const. of P.F.
Labour charges for installation of 10 HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge.
foundation nut bolt
Cost, Supplying of ISI marked 200 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc. co
mplete as per the direction of the Engineer-incharge.
Cost, Supplying of ISI marked 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc. complete as per the direction of the Engineer-incharge.
Fitting and Fixing 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 Pipe including jointing the pipe including fitting and fixing of required no. of Riser Tee for outlet and Shaddle and nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark.
100 mm dia G.I. bend IS No.1239(Part-II/1992)
100 mm dia G.I. flange IS No.6392 / 1971
Cost of Transportation, Fitting and Fixing 200 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 Pipe including jointing the pipe including fitting and fixing of required no. of Riser Tee for outlet and Shaddle and nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
100mm dia GI Socket IS 1239 (Part-II/1992 )
100mm dia GI Nipple IS 1239 (Part-II/1992 )
Cost of 100 mm dia C.I Sluice Valve
50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.
Cost of 100 mm dia C.I NR Valve
200 x 200 x160 mm dia spigot moulded reducing HDPE Tee 10 kg
Cost of 160mm x 160mm x 160mm HDPE Equal Tee spigot design 6kg
Cost of 160 mm dia HDPE End cap
Cost of 200 mm dia HDPE End cap
Cost of 100x100x25mm G.I Tee with Plug for priming
Cost of 200 mm Dia Slipon flange
5/8 x3" M.S Nut bolt as per IS specification
160 mm dia HDPE Elbow spigot design 6kg
Cost of 160 mm Dia Slipon flange
Cost of 200 mm dia HDPE tail piece 160mm long
Cost of Rubber insertion (1/8'') 3mm thick
Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST
Cost of 150mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022)
Cost of 160 mm dia HDPE tail piece 160 mm long
100mm dia C.I. Screw boss Foot Valve of swing type friction less with single disc conforming to IS-4038/1979 of reputed brand with ISI mark of reputed company having wide dealership network including all cost, conveyance, cess etc complete but excluding cost of GST
Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp
63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.
3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.
Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduite pipe, No.6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation including fixing of TD cable inside the earth trench as per direction of Engineer-in-charge..
Electrical Earthing with digging earth pit of size (2 ft X 2 ft X 3 ft ) and using 1/2 '' G.I pipe ,No -6 G.I wire ,cable socket ,Flange , carcoal, salt etc. as per the direction of the Engineer-incharge.
Tool Box
10.0 HP/7.5 KW Energy efficiency mon oblock pumpset of total head 24 mtr having 1700 LPM discharge of reputed brand with BEE Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamp & 30 mtr of 4.00 sqmm flat cable and Impeller: Bronze grade LTB-2 of IS 318/1981 confirming to IS specification including all cost, conveyance, cess etc complete but excluding cost of GST etc. complete as per the direction of the Engineer-incharge.
Cost of M.S wall base frame with steel cover plate
6 KVAR Capacitor
Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red axide primer and two coats of powder coated paint of approved quality on both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board of approved brand including all cost, conveyance, cess etc complete as per the direction of the Engineer-In-Charge but excluding cost of GST
Construction and erection of 11 /0.4 KV,25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25 KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, barbed fencing ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.
Construction of boundry wall fancing ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc for substation as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.
stage.html
html • 0.04 MB
techsummary_565009.pdf
finsummary_565009.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.91 MB
Tendernotice_2.pdf
PDF • 1.54 MB
BOQ_565009.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid